ADM3071EYRZ - 3.3V 250kbps ESD RS-485 Transceiver
Référence : ADM3071EYRZ ✓ ActifADM3071EYRZ Présentation
An RS-485/RS-422 transceiver is an interface IC that converts logic-level signals into balanced differential signals for reliable communication over cables and printed-circuit-board interconnects. Differential signaling provides common-mode rejection and improves noise immunity. In the RS-485 hierarchy, the ADM3071EYRZ supports half-duplex or full-duplex bus arrangements, while its balanced receiver is compatible with RS-422 point-to-point links. The ADM307xE family is therefore positioned within interface ICs and data communications systems.
Key features include ±15 kV ESD protection, a maximum data rate of 250 kbps, operation from a 3.3 V supply, and an extended temperature option covering −40°C to +125°C. Hot-swap input structures on the DE and RE pins support robust control behavior, while reduced slew rates help limit electromagnetic interference. Driver and receiver outputs remain high impedance when disabled or powered off, allowing multiple devices to share a bus without unwanted active drive.
The device also provides common-mode input range support from −7 V to +12 V, thermal shutdown, and short-circuit protection. These protections address common field-bus failure conditions involving electrostatic discharge, wiring faults, and excessive bus loading. The low-power design reduces supply demand in distributed nodes, although total node power depends on operating state, termination, bus loading, and the number of connected transceivers.
Typical uses include industrial supervisory networks, building-control equipment, security and access systems, factory automation links, and instrumentation connected over long cable runs. A 250 kbps rate is appropriate for control data, configuration traffic, and moderate polling workloads rather than high-speed storage or continuous industrial vision pipelines. Full-duplex operation can provide independent transmit and receive paths when the system wiring permits it.
Place the device and its bus-interface components so that the RS-485 and RS-422 routing follows the layout guidance in the manufacturer datasheet. Keep differential traces tightly paired, provide the required termination and biasing at designated bus locations, and connect transceiver grounds according to the interface topology. Adequate bypass capacitance and controlled driver enable timing help avoid startup contention.
This product overview combines the manufacturer’s electrical and environmental specifications, package details, interface characteristics, application guidance, and verified replacement analysis. It also highlights the design constraints that matter when selecting a compact 3.3 V transceiver for industrial and embedded multipoint communication systems.
Alternatives de remplacement direct pour ADM3071EYRZ — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec ADM3071EYRZ (même facteur de forme et même empreinte) — différant par Maximum Data Rate, Package.
ADM3071EARZ
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →SN65HVD74D
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →ADM3071EYRZ Spécifications
| Tension d'alimentation | 3.3 V |
| Maximum Data Rate | 250 kbps |
| ESD Protection | ±15 kV |
| Supported Standards | TIA/EIA RS-485 and RS-422 |
| Communication Mode | Half-duplex or full-duplex |
| Driver and Receiver Count | 1 transmitter and 1 receiver |
| Température de fonctionnement | −40°C to +125°C |
| Common-Mode Input Range | −7 V to +12 V |
| Boîtier | 8-lead SOIC, 3.9 mm body width |
| Type de montage | Surface mount |
| DE and RE Input Structure | Hot-swap input |
| Slew Rate | Reduced EMI slew rate |
| Disabled Output State | High impedance |
| Power-Off Output State | High impedance |
| Protection | Thermal shutdown and short-circuit protection |
| Isolation | Non-isolated |
Configuration des broches de ADM3071EYRZ
| Broche 1 | RO — Receiver output |
| Broche 2 | RE — Receiver enable active-low input |
| Broche 3 | DE — Driver enable input |
| Broche 4 | DI — Driver data input |
| Broche 5 | GND — Ground |
| Broche 6 | Y — Noninverting receiver output |
| Broche 7 | A — Inverting receiver output |
| Broche 8 | VCC — Power supply |
Applications typiques
ADM3071EYRZ convient pour 6 applications: Industrial Supervisory Control Networks, Building Automation and HVAC Equipment, Security and Access Systems, Factory Automation and Sensor Networks, Test and Measurement Instrumentation, Embedded Communications Equipment.
Industrial Supervisory Control Networks
The ADM3071EYRZ suits industrial supervisory links that carry commands, status, and configuration data over balanced RS-485 wiring. Its 3.3 V supply reduces power demand at distributed nodes, while the 250 kbps rate supports moderate polling traffic without requiring a high-speed transceiver. The −40°C to +125°C grade is useful in equipment exposed to temperature variation, and ±15 kV ESD protection improves robustness at connector-accessible interfaces. The circuit uses the differential driver and receiver to carry data over a multipoint bus, with termination and bias placed only where required by the topology. Designers should still evaluate common-mode voltage, cable length, grounding, and fault conditions before approving the network for a specific plant environment.
Recommandé
Building Automation and HVAC Equipment
The ADM3071EYRZ is appropriate for building-control units, HVAC controllers, room sensors, and supervisory panels using low-power RS-485 communication. A 3.3 V operating supply simplifies integration with modern embedded controllers, and the 250 kbps rate is more than sufficient for routine command and telemetry traffic. Reduced slew rates help reduce electromagnetic emissions in equipment containing switching supplies and display circuitry. The transceiver can participate in half-duplex multidrop wiring or full-duplex point-to-point arrangements, depending on the bus design. At the board level, route the differential pair continuously, use suitable cable termination, and isolate long external wiring from sensitive logic to prevent transient energy from reaching the controller.
Recommandé
Security and Access Systems
The ADM3071EYRZ can connect access-control readers, door controllers, intercoms, and alarm panels in a distributed security network. Its ±15 kV ESD protection is particularly relevant when transceiver circuits connect to external cables that may be touched during installation or service. The 250 kbps data rate supports card events, status reporting, configuration traffic, and firmware-update messages without demanding high-speed differential signaling. A 3.3 V interface also simplifies coexistence with embedded processors and security peripherals. Use a consistent bus ground reference, place protection at the connector boundary when required, and validate the complete interface against the system’s surge and grounding strategy rather than relying on component ESD ratings alone.
Recommandé
Factory Automation and Sensor Networks
The ADM3071EYRZ is well suited to remote sensor, actuator, and motor-control modules connected through an RS-485 field bus. Its 250 kbps bandwidth accommodates periodic measurements and supervisory commands, while the extended-temperature option supports equipment installed near heat sources or in outdoor control cabinets. The receiver’s −7 V to +12 V common-mode input range provides additional operating margin for bipolar noise on grounded industrial wiring. Hot-swap inputs on DE and RE help manage bus direction changes, and reduced slew rates limit high-frequency emissions. For reliable deployment, use twisted-pair cabling, avoid star branches, place termination at the physical ends, and verify that selected sensors remain compatible with the bus bias voltage.
Recommandé
Test and Measurement Instrumentation
The ADM3071EYRZ can connect laboratory and field-test equipment to remote instrument heads or measurement fixtures through RS-485 or RS-422. Balanced differential signaling helps preserve data integrity when the cable runs near motors, relays, or switching power stages. The device’s 250 kbps rate is appropriate for commands, status, and moderately sampled measurement data rather than continuous high-bandwidth acquisition. Full-duplex wiring can separate transmit and receive paths where a point-to-point RS-422 architecture is preferred. Place the transceiver near the external connector, maintain a controlled ground connection, and use the manufacturer’s interface guidance for cable protection and termination. Confirm that the measurement system’s grounding method does not create excessive ground-loop current.
Recommandé
Embedded Communications Equipment
The ADM3071EYRZ provides a compact physical-layer interface for embedded controllers, gateways, and data concentrators that must communicate over RS-485 or RS-422. The 8-lead SOIC footprint conserves board area, and operation from 3.3 V allows direct interfacing with modern low-voltage digital controllers. Its high-impedance output behavior when disabled or powered off is valuable for multidrop buses where several nodes can connect to the same pair. The receiver can also accept signals outside the supply range within the specified −7 V to +12 V common-mode window, supporting partially powered or floating-node situations when the rest of the interface design permits it. Firmware should coordinate DE timing, prevent simultaneous active drivers, and avoid excessive polling that reduces network availability.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour ADM3071EYRZ — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | ADM3071EARZ | SN65HVD74D |
|---|---|---|---|
| Package | 8-lead SOIC | 8-lead SOIC | 8-lead SOIC |
| Brand | Analog Devices | Analog Devices | Texas Instruments |
| Maximum Data Rate | 250 kbps | 250 kbps | Higher-rate RS-485 interface; exact comparison value requires datasheet review |
| Supported Standards | RS-485 and RS-422 | RS-485 and RS-422 | RS-485 |
Principaux différenciateurs
- Extended-temperature ordering grade (vs ADM3071EARZ)
- ESD protection for connector-accessible industrial links (vs SN65HVD74D)
- Broad common-mode input operating window (vs SN65HVD74D)
- Hot-swap control inputs (vs SN65HVD74D)
Notes de conception
Route the A and Y differential conductors as a tightly coupled pair with continuous reference to a ground plane. Keep the transceiver close to the connector and place any line-side protection near the entry point. Avoid routing the pair through switching-power regions or digital clocks. When the transceiver is part of a full-duplex system, keep transmit and receive pairs physically separate to reduce crosstalk and maintain a predictable differential impedance.
Confirm DE and RE control polarity and timing against the manufacturer datasheet before programming the interface. Only one node should actively drive the bus at a time. Apply termination only at the physical endpoints of a multidrop bus, and install biasing at one designated location unless the system specification calls for a different arrangement. Incorrect termination or multiple bias networks can reduce common-mode margin and make communication unreliable.
The reduced slew rate helps limit radiated emissions, but EMI performance still depends on the complete interface. Use the shortest practical cable, maintain a consistent differential impedance, and provide a low-impedance return path. Locate protection and termination components near the connector or transceiver as appropriate. If switching regulators and the RS-485 interface share a board, separate their high-current paths and verify conducted and radiated emissions on the finished assembly.
Place the required supply bypass capacitor close to the VCC and GND pins and follow the manufacturer’s recommended layout. Keep transient current from external connectors and relay loads out of the transceiver supply path. The high-impedance output state assists multipoint operation, but a disabled or unpowered node still needs to remain compatible with the bus voltage and common-mode limits used elsewhere in the system.
Informations de conformité
The manufacturer documentation identifies the device as a non-isolated RS-485/RS-422 interface transceiver. No explicit RoHS, REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification statement was identified in the verified manufacturer and distributor records.