ADM3072EYRZ - 250 kbps RS-485/RS-422 Transceiver | Analog Devices
Référence : ADM3072EYRZ ✓ ActifADM3072EYRZ Présentation
An RS-485/RS-422 transceiver is an interface IC that converts between logic-level signals and balanced differential bus signals. RS-422 supports point-to-multipoint balanced data links, while RS-485 supports multipoint communication and bus arbitration characteristics. The ADM3072EYRZ combines these bus functions with low-power operation, fail-safe receiver behavior, and electrostatic-discharge protection for industrial environments.
The ADM3072EYRZ operates from a 3.3 V supply and supports data rates up to 250 kbps. It is designed for half-duplex communication, allowing the driver and receiver to share the same differential pair. The device provides driver-enable and receiver-enable control inputs so a host or microcontroller can determine the direction of bus traffic. Its ±15 kV ESD rating protects the interface when cables are connected or disconnected in electrically noisy installations.
The ADM3072EYRZ provides a 1/8-unit-load receiver characteristic, as identified in the product overview. This permits multiple nodes on the same bus while controlling the loading presented by each receiver. The low-power architecture is useful for industrial controllers, measurement equipment, and embedded systems where the interface must maintain reliable communication without imposing excessive supply demand.
Typical uses include motor-control equipment, industrial sensors, remote I/O modules, PLC peripherals, data-acquisition systems, and communications between control boards and field devices. The 8-pin SOIC package permits a compact board footprint and supports conventional surface-mount assembly.
When laying out a circuit, route the differential bus pair as a controlled-impedance pair, keep the driver and receiver connections close to the transceiver, and provide the bus termination and protection required by the installation. Use the manufacturer datasheet pin configuration and recommended external network when assigning PCB tracks and connectors.
This page combines the ADM3072EYRZ interface role, package information, sourcing guidance, practical applications, and drop-in comparison options to support faster component selection and board-level implementation.
Alternatives de remplacement direct pour ADM3072EYRZ — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec ADM3072EYRZ (même facteur de forme et même empreinte) — différant par Package, Supply Voltage.
ADM3072EARZ
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →MAX3072EASA+
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
SP3072EEN-L/TR
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
SP3072EMN-L/TR
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
XR3072XID-F
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
XR3072XID
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
ADM3072EYRZ Spécifications
| Product Type | RS-485/RS-422 transceiver |
| Tension d'alimentation | 3.3 V |
| Maximum Data Rate | 250 kbps |
| Communication Mode | Half-duplex |
| Driver and Receiver Count | 1 transmitter and 1 receiver |
| ESD Protection | ±15 kV |
| Receiver Loading | 1/8 unit load |
| Supported Standards | RS-485 and RS-422 |
| Boîtier | 8-pin SOIC |
| Type de montage | Surface Mount |
| Transceiver Configuration | 1/1 transceiver |
| Fail-Safe Receiver | Yes |
| Driver Enable Control | DE/RE control |
| REACH Status | Compliant |
| Conflict Minerals Status | DRC Conflict Free |
| Manufacturer Document Revision | Rev. F |
Guide de configuration des broches du ADM3072EYRZ 8-pin soic
Configuration des broches du ADM3072EYRZ (boîtier 8-pin soic). La numérotation des broches, les fonctions et les schémas de connexion sont définis dans la fiche technique du fabricant. Consultez-la pour l'empreinte exacte et les directives de soudage.
Aucune donnée de brochage détaillée disponible pour ADM3072EYRZ.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
ADM3072EYRZ convient pour 6 applications: Industrial Sensor Networking, Factory Automation Equipment, Building Control Networks, Motor and Power Monitoring, Data Acquisition Systems, Communication Port Protection.
Industrial Sensor Networking
The ADM3072EYRZ suits RS-485 sensor and instrumentation networks that require reliable differential signaling over industrial cables. Its 3.3 V supply, 250 kbps maximum data rate, 1/8-unit-load receiver, and ±15 kV ESD protection allow several field nodes to share a bus while limiting receiver loading. Place the transceiver at the cable entry point, use controlled-impedance differential routing, and provide termination only where required by the bus topology. The 8-pin SOIC package supports compact controller boards, while the half-duplex DE/RE arrangement permits a host to control bus direction without adding a separate bus-switch device.
Recommandé
Factory Automation Equipment
The ADM3072EYRZ is appropriate for factory automation links where controller cards communicate with actuators, remote I/O, and programmable logic equipment over RS-485. Its 250 kbps rate is adequate for supervisory command traffic and periodic sensor data, while the 1/8-unit-load characteristic supports multiple receivers on a segment. The differential bus reduces susceptibility to industrial noise compared with single-ended signaling, and the ±15 kV ESD protection provides valuable interface ruggedness at external connectors. Confirm grounding, surge protection, and termination strategy for the installation so the transceiver operates within the system’s common-mode and fault-recovery requirements.
Recommandé
Building Control Networks
The ADM3072EYRZ can connect thermostats, controllers, access-control units, and environmental sensors in a low-cost building automation network. Its half-duplex RS-485/RS-422 operation supports a shared bus architecture, while the 250 kbps limit comfortably accommodates command and telemetry traffic below that speed. The 1/8-unit-load receiver helps preserve bus margin when several building controllers are installed, and the low-power 3.3 V operation suits embedded control boards. Use consistent termination at physical bus ends and route the differential pair away from switching nodes and high-current relays to preserve signal integrity throughout the building wiring.
Recommandé
Motor and Power Monitoring
The ADM3072EYRZ is useful for motor-drive diagnostics, power-monitoring equipment, and other systems that exchange measurements over a wired differential bus. The device’s ±15 kV ESD protection helps protect the interface when service personnel connect or disconnect field cables, while 1/8-unit-load operation supports shared instrumentation buses. At the 250 kbps maximum rate, it can carry commands, operating status, and sampled measurement data without becoming the communication bottleneck. Keep the transceiver close to the cable connector, add appropriate surge and common-mode protection, and avoid allowing cable transients to exceed the absolute maximum ratings specified by the manufacturer.
Recommandé
Data Acquisition Systems
The ADM3072EYRZ supports distributed data-acquisition systems in which measurement modules return readings to a host computer over an RS-485 network. Its 1/8-unit-load receiver permits multiple instrument nodes, and the differential bus improves noise immunity in laboratories and production environments. The 250 kbps rate is suitable for periodic sensor readings and configuration commands rather than continuous high-volume transfer. Place the transceiver at the edge of the acquisition board, maintain symmetry between the A and B routes, and apply termination according to the number and placement of connected modules. Test bus behavior with idle bias and fault conditions to preserve receiver validity.
Recommandé
Communication Port Protection
The ADM3072EYRZ is appropriate for protected communication ports in embedded equipment where an RS-485 or RS-422 connector reaches outside the enclosure. Its ±15 kV ESD protection improves resilience to electrostatic discharge encountered during connection or maintenance, and the balanced interface supports communication over longer cable runs. The 8-pin SOIC package leaves board area for external protection components and connectors. In the completed design, route the transceiver pins toward the protection network, connect the bus ground appropriately, and maintain short return paths. The onboard ESD rating should complement rather than replace correctly selected surge, overvoltage, and common-mode protection.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour ADM3072EYRZ — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | ADM3072EARZ | MAX3072EASA+ | SP3072EEN-L/TR | SP3072EMN-L/TR |
|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Maxim Integrated | Exar | Exar |
| Package | 8-pin SOIC | 8-pin SOIC | 8-pin NSOIC | 8-pin SOIC | 8-pin SOIC |
| Product Type | RS-485/RS-422 transceiver | RS-485/RS-422 transceiver | RS-485/RS-422 transceiver | RS-485/RS-422 transceiver | RS-485/RS-422 transceiver |
Principaux différenciateurs
- Supports both RS-485 and RS-422 on one compact interface (vs MAX3072EASA+)
- Supports multiple nodes with reduced receiver loading (vs SP3072EEN-L/TR)
- Direct manufacturer-suggested alternate available (vs SP3072EEN-L/TR)
- Provides defined ESD ruggedness for field connections (vs ADM3072EARZ)
Notes de conception
Place the ADM3072EYRZ close to the external RS-485 or RS-422 connector and route the differential pair as a matched, controlled-impedance pair. Keep the A and B traces adjacent, avoid crossing split power planes, and minimize stub branches to unused transceiver or protection inputs. Position the bus termination and protection components near the connector so surge current is diverted before reaching the transceiver pins.
Do not treat ±15 kV ESD protection as a complete industrial surge-protection solution. Select external TVS, common-mode chokes, resistors, and fuses for the installation’s cable length, grounding method, and required surge level. Also verify that enable polarity, receiver fail-safe behavior, and idle-bus voltage match the host controller; a common 8-pin package does not guarantee identical pin functions across every alternate.
Separate the digital transceiver area from switching supplies, high-current relays, and motor-drive stages. Use a continuous ground reference beneath the interface area where the board design permits, and connect the bus cable shield according to the installation’s grounding strategy. Validate eye quality and common-mode limits at the connector with the actual cable, termination, and protection network rather than relying on logic-level simulations alone.
Informations de conformité
The catalog information identifies the exact ADM3072EYRZ as REACH compliant and DRC Conflict Free. RoHS, lead-free, and halogen-free status were not confirmed for the exact ordering code.