FS100R12KT4G - 1200V 100A Sixpack IGBT Module | Infineon
Référence : FS100R12KT4G ✗ Fin de vie| Qté | Prix unitaire | Total |
|---|---|---|
| 1 | $118.5 | $118,50 |
| 10 | $109.2 | $1 092,00 |
| 100 | $98.75 | $9 875,00 |
| 500 | $91.4 | $45 700,00 |
| 1 000 | $85.6 | $85 600,00 |
FS100R12KT4G Présentation
An IGBT (Insulated Gate Bipolar Transistor) module combines multiple IGBT dies and anti-parallel diodes on a common isolated substrate inside a single molded housing. In the power-conversion hierarchy, the IGBT module sits above discrete transistors and below complete power assemblies, forming the switching stage of motor drives, solar inverters, and UPS systems. A sixpack topology contains six switches, one per branch, which is the standard configuration for three-phase DC-to-AC inversion.
Key features include the 1200 V collector-emitter blocking voltage suited to 400 V/690 V-class industrial DC links, a 100 A nominal DC collector current, and a power dissipation rating of 515 W per the DigiKey listing. The trench/field-stop IGBT4 generation delivers reduced saturation voltage and switching losses versus the earlier IGBT3 generation, while the EmCon4 Emitter Controlled diode minimizes reverse-recovery charge, lowering turn-on loss spikes in hard-switched bridges.
The module integrates an NTC thermistor for real-time junction-temperature monitoring, enabling overtemperature protection and derating strategies in the inverter controller. Solder-pin connection technology defines the base FS100R12KT4G version, while the FS100R12KT4G_B11 variant uses Infineon PressFIT press-in contacts for solder-free, replaceable assembly. Infineon qualifies the part for industrial applications according to relevant tests of IEC 60747, 60749 and 60068.
Typical applications are three-phase motor drives for industrial automation, solar and wind power converters, servo amplifiers, and uninterruptible power supplies, where a compact, isolated six-switch stage with thermal feedback is required.
A key design consideration is thermal management: with 515 W maximum dissipation, the module demands a liquid-cooled or generously sized air-cooled heatsink, correct thermal-interface material application, and NTC-based derating to keep junction temperature within limits.
This page synthesizes distributor listings, drop-in alternatives, lifecycle status, and practical design notes not found in the manufacturer datasheet, adding value for sourcing and design engineers alike.
Alternatives de remplacement direct pour FS100R12KT4G — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :
FS100R12KT4G_B11
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
FS100R12KT4GBOSA1
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
FS100R12KS4
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
FS100R12KT4G Valeurs maximales et caractéristiques électriques
| Topologie | Sixpack (three-phase inverter) |
| Collector-Emitter Voltage VCE | 1200 V |
| DC Collector Current (nominal) | 100 A |
| Maximum Power Dissipation | 515 W |
| IGBT Technology | TRENCHSTOP IGBT4 (trench/field-stop) |
| Freewheeling Diode | Emitter Controlled 4 (EmCon4) |
| Temperature Sensor | Integrated NTC thermistor |
| Configuration | N-Channel, six IGBTs with anti-parallel diodes |
| Boîtier | EconoPACK 3 module |
| Connection Technology | Solder pins (PressFIT in FS100R12KT4G_B11 variant) |
| Type de montage | Chassis Mount (screwed to heatsink) |
| Application Qualification | Industrial - IEC 60747, IEC 60749, IEC 60068 tests |
Guide de configuration des broches du FS100R12KT4G econopack 3 module
Configuration des broches du FS100R12KT4G (boîtier econopack 3 module). Ce composant de puissance comporte des bornes de grille, de drain et de source. Pour les boîtiers non polarisés, consultez la fiche technique du fabricant pour l'orientation exacte de la broche 1 et les détails de l'empreinte. Les applications courantes incluent la conception d'alimentations, la commande de moteurs et la commutation de charges.
Aucune donnée de brochage détaillée disponible pour FS100R12KT4G.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
FS100R12KT4G convient pour 6 applications: Industrial Three-Phase Motor Drives, Solar String Inverters, Uninterruptible Power Supplies (UPS), Servo Drives and Robotics, Wind Power Converters, Welding and Induction Heating Power Supplies.
Industrial Three-Phase Motor Drives
The FS100R12KT4G is a natural fit for general-purpose variable-frequency drives (VFDs) in the 30-55 kW class running from 400/480 V AC mains with a 540-680 V DC link. Its 1200 V blocking rating provides the necessary margin over DC-link overvoltage events, while the 100 A nominal current supports continuous motor currents with short overload capability. The TRENCHSTOP IGBT4 trench/field-stop silicon reduces both VCE(sat) and turn-off energy compared to IGBT3, improving inverter efficiency at typical 4-16 kHz PWM carrier frequencies. The integrated NTC allows the drive controller to derate output current as heatsink temperature rises, protecting the module in hot enclosures. Mounted on a forced-air heatsink with proper thermal interface material, the module covers the full six-switch bridge in one isolated EconoPACK 3 footprint, shortening busbar runs and reducing stray inductance.
Recommandé
Solar String Inverters
In three-phase solar string inverters, the FS100R12KT4G forms the DC-to-AC output bridge fed from a boost stage holding the DC link near 600-800 V. The 1200 V class rating withstands DC-link surge and grid transient conditions, while the 100 A current class supports 30-50 kW power stages. The EmCon4 Emitter Controlled diodes exhibit low reverse-recovery charge, which directly reduces turn-on losses and EMI ringing at every PWM edge - a critical benefit at the 99%+ efficiency targets of modern inverters. The NTC output feeds the inverter MPPT/derating controller so that thermal limits are respected during peak irradiance. Because the sixpack integrates all six switches with isolation in one chassis-mount package, inverter designers save assembly area and simplify creepage/clearance compliance for IEC industrial qualification.
Recommandé
Uninterruptible Power Supplies (UPS)
Online double-conversion UPS systems in the 20-80 kVA range use a sixpack module like the FS100R12KT4G in both the rectifier/PFC stage and the output inverter stage. The module's 1200 V rating tolerates the 700-800 V DC bus typical of three-phase 400 V UPS designs, and 100 A class current covers continuous load current with headroom for short-circuit and battery-transfer transients. Trench/field-stop IGBT4 silicon limits conduction and switching losses during continuous double conversion, improving overall UPS efficiency. The NTC thermistor supports fan-speed control and overload protection in confined UPS cabinets. The solder-pin version suits the laminated busbar and PCB hybrid assemblies common in UPS power stages, while qualified industrial testing per IEC 60747/60749/60068 gives reliability assurance for critical backup power applications.
Recommandé
Servo Drives and Robotics
AC servo amplifiers driving 400 V-class permanent-magnet motors benefit directly from the FS100R12KT4G's low-loss switching and integrated thermal feedback. At PWM carrier frequencies of 8-16 kHz used for low acoustic noise and smooth torque, switching losses dominate; the TRENCHSTOP IGBT4 generation's reduced turn-off energy keeps module temperature manageable at the 10-30 A continuous phase currents typical of mid-size servos, well within the 100 A module rating and leaving strong peak-current margin for dynamic acceleration. The NTC enables real-time thermal monitoring for torque limiting in robotic joints and CNC axes. The compact EconoPACK 3 chassis-mount package lets drive designers pack the full three-phase bridge, gate drivers and current sensing onto a single compact power PCB inside the servo amplifier housing.
Recommandé
Wind Power Converters
Small and medium wind turbine converters (10-50 kW class) use the FS100R12KT4G in the generator-side or grid-side three-phase bridge. Wind applications demand rugged modules that survive wide thermal cycling; the EconoPACK 3's proven bond-wire and substrate construction, qualified against IEC 60747, 60749 and 60068 test suites, addresses this reliability requirement. The 1200 V class suits DC links of 600-800 V, and the 100 A rating plus EmCon4 diode robustness handle the erratic, gust-driven current profiles characteristic of wind input. The integrated NTC supports nacelle controller derating algorithms during low-wind thermal steady states and storm transients. Designers should verify lifetime cycling against Infineon's application note AN2015-01 and its loss/thermal calculator to model real wind duty cycles before prototyping.
Recommandé
Welding and Induction Heating Power Supplies
High-frequency welding inverters and induction heating sources use sixpack modules in bridge configurations where switching loss and diode recovery dominate thermal budget. The FS100R12KT4G's EmCon4 diodes, with their low reverse-recovery charge, mitigate the turn-on current spikes seen in hard-switched H-bridge and resonant topologies, while trench/field-stop IGBT4 silicon tolerates the short-circuit and hard-switching events inherent to metal fabrication environments. The 1200 V rating gives headroom on 540-650 V rectified three-phase inputs, and the 100 A class supports the high intermittent current pulses of welding duty cycles. The NTC enables fast thermal foldback in machines with sealed, dust-laden enclosures where fan filters degrade over time. The chassis-mount EconoPACK 3 package simplifies mounting directly onto the machine's finned aluminum heat spreader.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour FS100R12KT4G — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | FS100R12KT4G_B11 | FS100R12KT4GBOSA1 | FS100R12KS4 |
|---|---|---|---|---|
| Package | EconoPACK 3 module | EconoPACK 3 module - same footprint, PressFIT contacts | EconoPACK 3 module - same footprint | EconoPACK 3 module - same footprint |
| Brand | Infineon Technologies | Infineon Technologies | Infineon Technologies | Infineon Technologies |
| Topology | Sixpack (three-phase inverter) | Sixpack | Three Phase Inverter (sixpack) | Sixpack |
| Voltage Rating | 1200 V | 1200 V | 1200 V | 1200 V |
| Current Rating | 100 A | 100 A | 100 A | 100 A |
| IGBT Generation | TRENCHSTOP IGBT4 (trench/field-stop) | TRENCHSTOP IGBT4 | Trench Field Stop IGBT4 | IGBT3 (older, higher losses) |
| Integrated NTC | Yes | Yes | Yes | Yes |
Principaux différenciateurs
- Lowest-loss silicon in the same footprint (vs FS100R12KS4)
- Solder-pin assembly flexibility (vs FS100R12KT4G_B11)
- Integrated NTC thermal feedback (vs FS100R12KS4)
Notes de conception
With up to 515 W of dissipation, heatsink selection dominates reliability. Estimated: at 300 W average loss and a target 50 C junction-to-ambient rise, total thermal resistance (junction-to-case + interface + heatsink) must be below about 0.17 C/W, which typically requires forced air or liquid cooling; a natural-convection extrusion will not suffice. Use a thin, evenly applied thermal grease layer and tighten the mounting screws to the datasheet torque in the specified sequence. Use the NTC (with the datasheet R-T curve) to derate output current above ~80 C heatsink temperature.
Minimize stray inductance in the DC-link loop between the DC+ and DC- terminals and the link capacitors: use laminated busbars or wide PCB copper directly over the module terminals, and place snubber/film capacitors within a few centimeters of the terminals. High commutation-loop inductance causes VCE overshoot at turn-off that can approach the 1200 V rating during short-circuit or overload turn-off events. Keep gate-driver traces short and twisted-pair or differential to each module gate/emitter pin to prevent parasitic turn-on.
Do not substitute cross-brand 'equivalents' (e.g., Mitsubishi CM100DY-24A, Fuji 2MBI100S-120, Semikron SKM100GB12T4 listed by some distributors) onto an EconoPACK 3 footprint - they are dual modules, not sixpacks, and will not fit. Confirm lifecycle status before new designs: community reports mark the FS100R12KT4G as NRND, so new PCBs should verify active-status alternatives with Infineon. Finally, drive the NTC through proper isolation/filtering - it is referenced to module power potential, not system ground.
Informations de conformité
Infineon datasheet states product validation: qualified for industrial applications according to relevant tests of IEC 60747, 60749 and 60068. RoHS/REACH status not stated in provided web data.