Analog Devices

ICL7136RCPL - 3.5-Digit LCD A/D Converter | Analog Devices

Référence : ICL7136RCPL ✓ Actif
40-pin plastic DIP Package
MOQ : 1 |

ICL7136RCPL Présentation

The Analog Devices ICL7136RCPL is a low-power, 3.5-digit monolithic analog-to-digital converter with a 40-pin through-hole DIP package. It combines a high-impedance dual-slope ADC, seven-segment decoders, display drivers, an internal voltage reference, and a clock in one integrated circuit. The converter is designed for direct LCD display interfaces and provides three digits plus sign, or 1999 counts, of measurement resolution.

An analog-to-digital converter is an interface device that converts a continuously varying voltage into a numeric value. The ICL7136RCPL belongs to the dual-slope ADC family, where an input voltage is measured by charging and discharging an integrated capacitor. The ADC integrates during a fixed input interval and then compares the resulting reference time with the system clock, producing a stable result without requiring a high-speed flash-conversion architecture.

Integrated display support reduces the external component count in digital panel instruments. The ICL7136RCPL contains segment decoders and LCD drivers in addition to the converter, while its reference and clock are also on-chip. This integration makes the device suitable for standalone measurement products where the measured value must be displayed directly without a separate display controller.

The dual-slope architecture is particularly useful for panel meters because it provides good rejection of periodic noise when the integration period is synchronized with the interfering signal. The converter is designed for low power consumption and high input impedance, reducing the loading on sensors and resistive dividers. Its integrated LCD interface allows a compact instrument design with fewer external components and fewer interconnections.

Typical applications include digital panel meters, laboratory instruments, temperature indicators, process-monitoring displays, weighing equipment, and portable measurement devices. The internal reference and clock simplify standalone designs, while the integrated display drivers reduce PCB area. The 40-pin through-hole package is also appropriate for instrument equipment that favors socketed components, repairability, and robust lead-based assembly.

PCB design should preserve the converter's high input impedance by keeping analog input traces short and away from display-drive and clock lines. Adequate bypassing is required near the supply pins, and unused inputs should be handled according to the manufacturer pin-description table. Confirm the exact LCD segment connections, reference voltage, supply limits, and electrical performance against the current manufacturer datasheet before production release.

This page combines device specifications, drop-in replacement guidance, display-interface application notes, and package-level selection criteria for engineers evaluating the ICL7136RCPL. It is intended to accelerate PCB reuse decisions while highlighting the key architectural and practical trade-offs associated with a monolithic dual-slope LCD ADC.

Alternatives de remplacement direct pour ICL7136RCPL — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Variantes de cette série

Modèles de la même série directement compatibles avec ICL7136RCPL (même facteur de forme et même empreinte) — différant par Resolution.

Analog Devices
Resolution: 3.5 digits
Comparer avec ICL7136RCPL →

ICL7136CPL+

✅ Remplacement direct
Analog Devices
📦 40-pin plastic DIP
3.5-digit monolithic analog-to-digital converter · 3.5 digits · Dual-slope conversion · Differential or single-ended · Very high input impedance · Seven-segment decoders, display drivers, voltage reference, and clock · Direct non-multiplexed LCD display drive · Low-power A/D converter

Contactez-nous pour le prix

Voir la fiche technique →

ICL7136CPL+

✅ Remplacement direct
Analog Devices
📦 40-pin plastic DIP
3.5-digit monolithic analog-to-digital converter · 3.5 digits · Dual-slope conversion · Differential or single-ended · Very high input impedance · Seven-segment decoders, display drivers, voltage reference, and clock · Direct non-multiplexed LCD display drive · Low-power A/D converter

Contactez-nous pour le prix

Voir la fiche technique →

ICL7136CPLZ

✅ Remplacement direct
📦 40-pin plastic DIP
Same ICL7136 3.5-digit LCD ADC family and 40-pin DIP format; listed functional difference is 0%, with temperature or ordering suffix requiring review

📋 Alternative de référence (hors catalogue)

MAX131CPL

✅ Remplacement direct
📦 40-pin plastic DIP
Same 3.5-digit dual-slope converter concept, display integration, and 40-pin DIP footprint; core listed parameter difference is 0%

📋 Alternative de référence (hors catalogue)

TC7136RCPL

✅ Remplacement direct
📦 40-pin plastic DIP
Same low-power 3.5-digit dual-slope LCD converter in a 40-pin DIP; core listed resolution and package differences are 0%, subject to electrical-limit verification

📋 Alternative de référence (hors catalogue)

ICL7136RCPL Valeurs maximales et caractéristiques électriques

ADC Type 3.5-digit dual-slope A/D converter
Résolution 3.5 digits (1999 counts)
Display Decoder Integrated seven-segment decoder
Display Driver Integrated LCD segment and backplane drive
Conversion Technique Dual-slope integration
Temperature Grade Commercial
Package Type 40-pin plastic DIP
Terminal Count 40 terminals
Type de montage Through-hole
Package Shape Rectangular

Guide de configuration des broches du ICL7136RCPL rectangular

Configuration des broches du ICL7136RCPL (boîtier rectangular). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.

Schéma de brochage du boîtier rectangular pour le ICL7136RCPL

Aucune donnée de brochage détaillée disponible pour ICL7136RCPL.

Consultez la fiche technique pour la configuration complète des broches.

Applications typiques

ICL7136RCPL convient pour 6 applications: Digital Panel Meters, Laboratory Measurement Instruments, Temperature Indicators, Process Monitoring Displays, Portable Measurement Devices, Weighing Scale Readouts.

🔧

Digital Panel Meters

The ICL7136RCPL fits digital panel meters because it combines a 3.5-digit, 1999-count dual-slope ADC with the display decoding and LCD drive circuitry needed for a direct numeric readout. The converter accepts a high-impedance measurement input and performs the conversion locally, reducing the number of external ICs and board interconnections. Its 40-pin through-hole DIP package also suits repairable industrial instrumentation assembled with socketed or leaded components. Designers should verify the LCD segment mapping, input range, reference behavior, and update timing against the application display.

⚡

Laboratory Measurement Instruments

The ICL7136RCPL is useful in laboratory instruments that present a stable numeric measurement without requiring a high-speed digital data interface. Its 3.5-digit dual-slope conversion architecture, internal clock, and internal reference consolidate several analog and display functions into one 40-pin DIP device. This allows a front panel to remain electrically simple while a calibrated sensor or divider feeds the converter input. Because the device is optimized for an instrument readout rather than waveform acquisition, applications requiring rapid sample rates or calibrated digital data should use a different ADC architecture.

🧩

Temperature Indicators

The ICL7136RCPL can display temperature from a resistive sensor when the measurement front end provides a suitable analog voltage. Its high input impedance helps avoid loading the sensor network, while the 3.5-digit resolution supports 1999-count panel readings. The integrated reference and clock reduce external circuitry, and the LCD driver permits a compact handheld or fixed indicator. The actual temperature accuracy depends on sensor tolerance, excitation stability, reference accuracy, calibration, and linearization, so those elements must be evaluated separately from the converter specification.

🏭

Process Monitoring Displays

The ICL7136RCPL is appropriate for process-monitoring equipment that must show a slowly changing process value on an LCD. A dual-slope measurement can provide useful rejection of periodic interference when the integration timing is coordinated with the noise source, and the high-input-impedance measurement stage places limited demand on sensor and divider networks. Onboard display drivers reduce the controller burden and board area. The design should include supply bypassing, protected analog routing, and an input filter selected for the sensor bandwidth and required response time.

📱

Portable Measurement Devices

The ICL7136RCPL supports portable, battery-operated measurement devices where a dedicated low-power display readout is more useful than a communications-heavy converter. Its integrated clock, reference, segment decoders, and LCD drivers reduce the number of powered components, while the 3.5-digit result provides enough resolution for many handheld instruments. The 40-pin DIP format favors serviceable prototypes and leaded assembly. Final power budgeting must include converter supply current and LCD load, and the display must be selected for compatibility with the integrated drive arrangement.

🔧

Weighing Scale Readouts

The ICL7136RCPL can serve as the measurement and display engine in a basic weighing-scale readout because it converts a bridge-derived analog voltage into a 3.5-digit value and drives the LCD directly. The high input impedance is valuable when the measurement path includes a high-resistance divider or transducer interface. Integrating the converter, clock, reference, decoder, and display driver lowers component count compared with a general-purpose ADC plus separate display controller. Practical designs must still address bridge excitation, input protection, offset and gain calibration, temperature drift, and mechanical vibration.

Récapitulatif des produits recommandés

ICL7136CPL 40-pin DIP family variant for panel-meter designs Utilisé dans : Digital Panel Meters, Temperature Indicators, Portable Measurement Devices MAX131CPL Integrated dual-slope LCD converter alternative Utilisé dans : Digital Panel Meters, Process Monitoring Displays, Weighing Scale Readouts ICL7136CPL+ Analog Devices Utilisé dans : Laboratory Measurement Instruments, Process Monitoring Displays ICL7136CPLZ Same-family integrated LCD ADC option Utilisé dans : Laboratory Measurement Instruments, Portable Measurement Devices TC7136RCPL Cross-brand integrated measurement-display converter Utilisé dans : Temperature Indicators, Weighing Scale Readouts
What is the ICL7136RCPL?
The ICL7136RCPL is a low-power, 3.5-digit monolithic dual-slope analog-to-digital converter in a 40-pin plastic DIP package. According to the Analog Devices ICL7136 datasheet, it integrates seven-segment decoders, LCD drivers, a voltage reference, and a clock. The device converts a high-impedance analog input into a 1999-count result suitable for direct LCD instrumentation without a separate display driver.
What are the key specifications of ICL7136RCPL?
The ICL7136RCPL provides 3.5-digit resolution, equivalent to 1999 counts, and uses a dual-slope conversion technique. It includes an internal reference, clock, seven-segment decoder, and multiplexed LCD drive in a 40-pin through-hole DIP. The Analog Devices product documentation identifies the ICL7136 as a low-power converter designed for high-input-impedance measurements and direct liquid-crystal display interfaces.
What does ICL7136RCPL do in a digital panel meter?
The ICL7136RCPL measures an analog voltage and drives the numeric result on an LCD panel. Its 3.5-digit dual-slope ADC supports up to 1999 counts, while the integrated segment decoders and display drivers eliminate a separate LCD interface IC. According to the ICL7136 datasheet, this integration is intended to simplify low-power instruments such as digital panel meters and process-monitoring displays.
Where can I download the ICL7136RCPL datasheet PDF?
The official ICL7136 documentation is available from Analog Devices at https://www.analog.com/en/products/icl7136.html, with a Renesas-hosted datasheet also listed at https://www.renesas.com/en/document/dst/icl7136-datasheet. The manufacturer documentation covers the 3.5-digit conversion system, reference and clock functions, LCD drive arrangement, electrical limits, and pin assignments needed for the 40-pin DIP.
Where is the ICL7136RCPL pinout?
The ICL7136RCPL pinout is shown in the pin-configuration section of the manufacturer ICL7136 datasheet. The device uses a 40-pin plastic DIP with through-hole leads. Use the numbered package drawing when assigning LCD segment, backplane, analog-input, reference, clock, and supply connections, and do not infer unused-pin functions from the generic ADC or DIP package.
What can replace the ICL7136RCPL?
The ICL7136CPL is a close 40-pin DIP replacement listed for the same ICL7136 converter family, while ICL7136CPL+ and MAX131CPL also appear in cross-reference results as terminal- and package-compatible devices. According to the ICL7136 comparison information, the listed functional characteristics and terminals are consistent. Confirm electrical limits, temperature grade, display timing, and qualification requirements before production substitution.
Is ICL7136RCPL the same as ICL7136CPL?
The ICL7136RCPL and ICL7136CPL are closely related 40-PDIP ICL7136 variants, but the complete suffix should be checked before interchange. The verified distributor information identifies the ICL7136CPL as a 40-PDIP commercial-temperature converter. Verify the ordered part number, date code, qualification level, and manufacturer documentation when substituting one orderable suffix for another.
Can TC7136RCPL replace ICL7136RCPL?
The TC7136RCPL is a cross-brand candidate for the ICL7136RCPL because cross-reference information identifies it as a comparable low-power, 3.5-digit, 40-pin DIP dual-slope converter. The candidate is sourced from web cross-reference results rather than internal component records. Verify pin behavior, reference accuracy, conversion timing, display outputs, supply range, and lifecycle status in the relevant manufacturer datasheet before substitution.
What is the best MAX131CPL equivalent for ICL7136RCPL?
MAX131CPL is presented in cross-reference information as a terminal- and package-consistent alternative to the ICL7136CPL family. It provides a 40-pin through-hole route for reusing an existing display-meter PCB. Because the cross-reference result does not provide every electrical limit, treat MAX131CPL as a qualified replacement candidate and confirm input range, reference voltage, LCD output arrangement, and accuracy before production use.
When should I choose ICL7136RCPL over a generic ADC?
Choose the ICL7136RCPL when the measurement needs a dedicated 3.5-digit instrument readout rather than a raw digital bus. It combines a high-impedance dual-slope ADC with seven-segment decoders, LCD drivers, an internal reference, and a clock in one 40-pin DIP. A generic ADC may offer faster conversion or digital communication, but it generally requires additional display-control hardware and software.
Is ICL7136RCPL suitable for temperature measurement?
The ICL7136RCPL is suitable for a resistive or ratiometric temperature-sensing front end when the sensor and analog input meet its accuracy and reference requirements. Its high input impedance helps minimize sensor-loading error, while the 3.5-digit format supports 1999-count panel readings. The sensor excitation, linearity correction, and conversion update rate must be evaluated separately.
How much power does the ICL7136RCPL consume?
The ICL7136RCPL is designed as a low-power converter, but a definitive operating-current value cannot be quoted without the electrical characteristics table. The Analog Devices and Renesas ICL7136 datasheets describe the integrated low-power architecture. Use the manufacturer supply-current limits and operating-mode data when sizing the supply, and account for LCD load current separately when calculating total system consumption.
Where can I buy ICL7136RCPL online?
Use the Request a Quote form on this page to request ICL7136RCPL availability, current pricing, minimum order quantity, and lead time. The component is a 40-pin commercial-grade DIP converter, and the verified product records identify active production and distributor channels. Submit the exact suffix ICL7136RCPL with your required quantity so the quotation matches the intended device.
What is the price of ICL7136RCPL?
Current ICL7136RCPL pricing is not displayed as a fixed value on this page. Use the Request a Quote form to obtain a current unit price and quantity breaks for the exact MPN and required quantity. The device is a 3.5-digit, 40-pin low-power LCD ADC, so quotes should also identify the package, commercial temperature grade, and production status being requested.
What is the lead time and stock status of ICL7136RCPL?
Current stock and lead time should be confirmed through the Request a Quote form on this page. The verified product records identify the ICL7136RCPL as an active-production 40-pin DIP converter and indicate distributor availability channels. Include your required date, annual usage, and acceptable package condition so the returned quotation can reflect the correct supply position.

Données de référence d'ingénierie pour ICL7136RCPL — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the ICL7136RCPL when the design requires a dedicated 3.5-digit LCD measurement instrument rather than a high-speed ADC with a digital interface. Its internal reference, clock, seven-segment decoder, and display drivers reduce external circuitry, while the 40-pin DIP supports repairable and serviceable instrument construction. ICL7136CPL is the closest same-family option when its ordering suffix and procurement record are acceptable. Use ICL7136CPL+ or ICL7136CPLZ when their specific qualification or temperature details meet the application. MAX131CPL and TC7136RCPL are useful cross-brand candidates for the same 40-pin display-meter architecture. Before selecting any substitute, verify the supply range, reference accuracy, conversion timing, input impedance, LCD mapping, temperature grade, and lifecycle status against the current manufacturer datasheet.

Comparaison avec les alternatives

Paramètre Ce produit ICL7136CPL ICL7136CPL+ ICL7136CPLZ MAX131CPL TC7136RCPL
Package 40-pin plastic DIP 40-pin plastic DIP 40-pin plastic DIP 40-pin plastic DIP 40-pin plastic DIP 40-pin plastic DIP
Brand Analog Devices Rochester Electronics Analog Devices Renesas Electronics Analog Devices Microchip Technology
ADC Resolution 3.5 digits, 1999 counts 3.5 digits, 1999 counts 3.5 digits, 1999 counts 3.5 digits, 1999 counts 3.5 digits, 1999 counts 3.5 digits, 1999 counts
Conversion Architecture Dual-slope Dual-slope Dual-slope Dual-slope Dual-slope Dual-slope
Display Decoder Integrated seven-segment decoder Integrated seven-segment decoder Integrated seven-segment decoder Integrated seven-segment decoder Integrated seven-segment decoder Integrated seven-segment decoder
LCD Drive Integrated Integrated Integrated Integrated Integrated Integrated
Internal Voltage Reference Yes Yes Yes Yes Yes Yes
Terminal Count 40 terminals 40 terminals 40 terminals 40 terminals 40 terminals 40 terminals

Principaux différenciateurs

  • Complete display interface integrated with the converter (vs Generic standalone ADC)
  • Direct family-level PCB reuse (vs ICL7136CPL)
  • Same measurement concept in a cross-brand route (vs TC7136RCPL)

Notes de conception

Route the high-impedance analog input as a short, guarded trace and keep it away from LCD drive, clock, and switching-supply nodes. Place the input network close to the converter and use a stable ground reference. If the source impedance is high, add the manufacturer-recommended input filter or buffer rather than relying on PCB capacitance alone, because leakage and stray coupling can degrade measurement stability.

Decouple the converter supply pins with the capacitance and placement specified in the manufacturer datasheet, placing the closest capacitor directly between the relevant supply and ground pins. Keep display-drive return current from sharing sensitive analog paths. When calculating battery life, include both the converter supply current and the LCD backplane and segment load, since integrated display drive can materially affect total system consumption.

Do not treat all ICL7136 suffixes as electrically identical without checking the ordering code, temperature grade, and qualification level. A physical DIP fit is not sufficient for production approval. Compare supply limits, reference accuracy, conversion timing, LCD segment mapping, and timing requirements with the original schematic and manufacturer datasheet before substituting any listed alternative.

Use the numbered manufacturer pin description when connecting the LCD because segment and backplane assignments are specific to the device. Maintain clearance between LCD drive outputs and the analog input, particularly around the input connector and sensor network. A solid ground plane can reduce return-path discontinuity, but analog and display-drive currents should still be routed so they do not cross beneath the sensitive input node.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

No specific RoHS, REACH, halogen-free, lead-free, or conflict-minerals statement appears for the exact ICL7136RCPL orderable part in the cited product information. AEC-Q100 is not applicable to this commercial-grade through-hole instrument converter.

Données vérifiées le : 2026-11-24 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

ICL7136RCPL datasheet ICL7136RCPL pinout ICL7136RCPL datasheet pdf ICL7136RCPL equivalent ICL7136RCPL replacement ICL7136RCPL cross reference ICL7136RCPL vs MAX131CPL ICL7136RCPL vs TC7136RCPL ICL7136RCPL 40 pin DIP ICL7136RCPL price ICL7136RCPL stock Analog Devices ICL7136RCPL ICL7136RCPL panel meter ICL7136RCPL footprint 3.5 digit 40 pin LCD ADC

Composants & termes associés

Analog Devices ICL7136RCPL ICL7136CPL ICL7136CPL+ ICL7136CPLZ MAX131CPL TC7136RCPL analog-to-digital converter ADC dual-slope ADC 3.5-digit A/D converter liquid crystal display LCD seven-segment decoder voltage reference integrated clock multiplexed backplane drive 40-pin plastic DIP PDIP through-hole package digital panel meter temperature indicator process monitoring weighing scale high input impedance
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ