Analog Devices

LT1102CH - 10/100 Gain JFET Instrumentation Amp | Analog Devices

Référence : LT1102CH ✓ Actif
180 uV Vdss < 10 pA Id TO-5, 8-lead hermetic metal can (CH) Package
MOQ : 1 |

LT1102CH Présentation

The Analog Devices LT1102CH is a high-speed, precision, JFET-input instrumentation amplifier with fixed gains of 10 or 100, 0.01% gain accuracy and 3 ppm non-linearity, packaged in an 8-lead hermetic TO-5 metal can.

An instrumentation amplifier is a differential-input amplifier whose internal gain is set by internal resistor networks rather than by external feedback components. It belongs to the amplifier IC hierarchy, which sits above the general-purpose operational amplifier: while an op-amp needs external resistors, matched networks and careful layout to reject common-mode noise, an instrumentation amplifier integrates the differential pair, gain network and output stage so that high common-mode rejection is achieved with essentially no user gain-setting hardware. The LT1102 family extends that concept into the fast FET-input domain, delivering precision DC accuracy together with wideband dynamic performance in a low-cost, space-saving 8-pin package.

Key features include a selectable fixed gain of 10 or 100, gain accuracy of 0.01%, non-linearity of 3 ppm, input offset voltage of 180 microvolts, and input bias plus offset currents below 10 pA. No external gain-setting resistor is required, which removes the resistor-tolerance and drift contribution that normally limits the accuracy of a discrete instrumentation front end. Slew rate, settling time, gain-bandwidth product and overdrive recovery time are all improved relative to competitive high-speed instrumentation amplifiers of the generation.

The JFET input stage gives very low input bias current and high input impedance, which is essential when the source is a resistive bridge, a thermocouple, or a high-impedance transducer whose output would otherwise be loaded by the amplifier. Internal precision matching and laser trimming of the gain network are what deliver the 0.01% gain accuracy and 3 ppm non-linearity figures, and the fixed-gain architecture removes the need for a user-supplied external network that would degrade both figures.

Typical applications include strain-gauge and load-cell bridge front ends, high-speed current shunt measurement, precision instrumentation for laboratory and test equipment, medical patient-monitoring signal chains, and industrial process-control sensor interfaces where fast settling after a large input step is required.

When designing with the LT1102CH, verify that the supply rails stay within the ±9 V to ±20 V operating window and that the input common-mode range and output swing remain valid for the chosen gain. Because the gain is fixed internally, the system designer selects the 10 or 100 gain version at ordering time rather than trimming gain in-circuit; layout should keep the input traces short, guarded and away from switching nodes to preserve the benefit of the low-noise JFET input stage.

This page brings together the manufacturer product information, the family-level precision and speed specifications, package and supply details, and engineering guidance on gain selection, layout and drop-in sourcing options that are spread across many separate documents.

Alternatives de remplacement direct pour LT1102CH — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

LT1102ACH

✅ Remplacement direct ⚠️ Spécifications non vérifiées
📦 TO-5, 8-lead hermetic metal can
identical gains (10/100), 0.01% gain accuracy and 3 ppm non-linearity; automotive-grade qualification and wider temperature coverage versus the standard LT1102CH, no electrical change

📋 Alternative de référence (hors catalogue)

LT1101CH

✅ Remplacement direct ⚠️ Spécifications non vérifiées
Analog Devices
📦 TO-5, 8-lead hermetic metal can
Precision micropower instrumentation amplifier · 10 or 100 · 1 circuit · 5 V · ±15 V · 1 lithium cell · 2 Ni-Cad batteries · 8-terminal TO-5, round metal package

Contactez-nous pour le prix

Voir la fiche technique →

LT1102CH Valeurs maximales et caractéristiques électriques

Product Type Instrumentation Amplifier, JFET input
Number of Channels 1
Internal Gain Options 10 or 100 (fixed)
Gain Accuracy 0.01%
Non-Linearity 3 ppm
Input Offset Voltage 180 uV
Input Bias Current < 10 pA
Input Offset Current < 10 pA
Supply Voltage Range (differential) +/-9 V to +/-20 V
Typical Dual Supply Rails +/-12 V, +/-15 V, +/-18 V
Boîtier TO-5, 8-lead hermetic metal can (CH)
Type de montage Through-hole, hermetic sealed
External Gain-Setting Resistor Required No
Input Stage Topology FET (JFET) differential input

Guide de configuration des broches du LT1102CH to-5, 8-lead hermetic metal can (ch)

Configuration des broches du LT1102CH (boîtier to-5, 8-lead hermetic metal can (ch)). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.

Schéma de brochage du boîtier to-5, 8-lead hermetic metal can (ch) pour le LT1102CH

Aucune donnée de brochage détaillée disponible pour LT1102CH.

Consultez la fiche technique pour la configuration complète des broches.

Applications typiques

LT1102CH convient pour 6 applications: Strain-Gauge and Load-Cell Bridge Front Ends, High-Speed Shunt and Current Sensing, Medical Patient Monitoring Signal Chains, Precision Test and Measurement Instrumentation, Industrial Process Control Sensor Interfaces, Audio and Instrumentation Signal Conditioning.

⚖️

Strain-Gauge and Load-Cell Bridge Front Ends

The LT1102CH is built for low-level bridge excitation measurement because its JFET input stage draws less than 10 pA of bias current, so the 120-350 ohm strain-gauge legs are effectively unloaded and the excitation rail sees no meaningful droop. With 0.01% gain accuracy and 3 ppm non-linearity, scale-factor error stays well below the budget of a typical 2 mV/V bridge output, while the 180 uV input offset voltage contributes negligibly next to a millivolt-level signal. The device is placed directly across the differential bridge output with a single gain of 10 or 100 selected at ordering, avoiding the external gain-setting resistor whose tolerance would otherwise dominate the error budget. Because the internal gain network is laser-trimmed, no user calibration of gain is required, only a simple zero and scale calibration in firmware. Place the amplifier close to the bridge connector and keep the input pair away from motor and relay wiring.

⚡

High-Speed Shunt and Current Sensing

Fast current measurement in switching converters, motor drives and battery systems needs an amplifier that settles quickly after a large input step, and the LT1102CH is described by the manufacturer as improving slew rate, settling time, gain-bandwidth product and overdrive recovery relative to competitive high-speed instrumentation amplifiers. With fixed gains of 10 and 100, the amplifier can sit directly across a milliohm shunt and present a scaled signal to the ADC without external gain components. Overdrive recovery matters when the sensed current steps abruptly, for example at PWM edges, because a slow recovery produces a false reading lasting long enough to corrupt a control loop. The low-noise JFET input also avoids adding noise directly to the measured shunt voltage. Keep the shunt and amplifier in a tight two-loop layout, and use a Kelvin connection at the shunt pads.

💊

Medical Patient Monitoring Signal Chains

Patient monitoring front ends work with microvolt to millivolt level bio-electrode signals where the amplifier must add as little error as possible, and the LT1102CH contributes less than 10 pA of input bias current with a 180 uV input offset voltage. That low-current input stage preserves the integrity of high-impedance skin electrodes and resistive sensor bridges without drawing signal charge from the source. The hermetic TO-5 metal can provides sealed, inert internal atmosphere and long-term stability, which suits equipment expected to remain in service for many years. The 0.01% gain accuracy keeps channel-to-channel and unit-to-unit calibration error predictable for traceable measurements. A 1.8 V to 5 V instrument amplifier front end is common in these designs, but the fast fixed-gain arrangement also suits monitor and diagnostic modules with wide bandwidth requirements.

🖥️

Precision Test and Measurement Instrumentation

Laboratory and factory test equipment often needs accurate gain without user calibration, and the LT1102CH provides fixed gains of 10 and 100 with 0.01% gain accuracy and 3 ppm non-linearity straight from the internal trimmed network. That removes the external gain-setting resistor, its tolerance contribution and its temperature coefficient from the error budget, which is exactly what limits the accuracy of many discrete instrumentation front ends. The device also saves board area by condensing the differential pair, gain network and output stage into an 8-pin hermetic package, so it suits bench instruments with dense analog sections. Because the amplifier is a single-channel part, dual-channel analysers typically pair two devices and rely on the tight gain matching of the trimmed internal networks for channel comparison. Keep the analog ground and the digital ground separated under the package to preserve measurement integrity.

🏭

Industrial Process Control Sensor Interfaces

Plant instrumentation handles sensors such as RTDs, thermocouples, pressure transducers and strain bridges that sit far from the electronics, so the interface amplifier must combine high input impedance with accurate, stable gain. The LT1102CH input bias current below 10 pA means even kilohm-level sources are barely loaded, preserving the true value of slow and small signals. The 0.01% gain accuracy and 3 ppm non-linearity translate directly into better measurement certainty at the plant floor, while the hermetic TO-5 package is well suited to long-life field equipment with wide temperature exposure. Because the gain is fixed internally at 10 or 100, designers can order the exact gain for a given sensor output and simplify calibration procedures. For installations with long cable runs, place the amplifier close to the sensor and protect the input nodes from common-mode interference.

🎧

Audio and Instrumentation Signal Conditioning

Precision audio and measurement signal chains need an amplifier that adds minimal noise and distortion while still handling fast transients, and the LT1102CH combines the low-noise JFET input stage with fixed gains of 10 and 100 for conditioning balanced or differential sources. Gain accuracy of 0.01% and non-linearity of 3 ppm keep level calibration stable across the input range, so a fixed trim in the equipment calibration table remains valid over time. The fast slew rate and improved settling behaviour described for the family help the amplifier recover cleanly from large signal steps, which matters in studio monitoring and instrumentation trigger paths. Because the gain is fixed internally, matching between channels is governed by the trimmed internal network rather than by user resistor selection. Follow the manufacturer layout guidance to keep the differential input loop small and away from digital return currents.

What is the LT1102CH?
The LT1102CH is a single-channel, high-speed, precision instrumentation amplifier with JFET inputs, offered by Analog Devices (formerly Linear Technology) in an 8-lead hermetic TO-5 metal can. According to the manufacturer product page, it is the first fast FET-input instrumentation amplifier offered in low-cost, space-saving 8-pin packages, with fixed gains of 10 and 100, 0.01% gain accuracy and 3 ppm non-linearity, and no external gain-setting resistor required.
What are the key specifications of LT1102CH that engineers should know?
The LT1102CH delivers fixed gains of 10 or 100 with 0.01% gain accuracy and 3 ppm non-linearity, an input offset voltage of 180 microvolts, and input bias and offset currents below 10 pA. The manufacturer datasheet describes improved slew rate, settling time, gain-bandwidth product and overdrive recovery time compared with competitive high-speed instrumentation amplifiers, and the part operates from +/-9 V to +/-20 V in an 8-lead hermetic TO-5 package.
What is the input bias current of the LT1102CH?
Input bias current in the LT1102CH is less than 10 pA, and the input offset current is also below 10 pA. According to the Analog Devices product page, this precision is combined with an input offset voltage of 180 microvolts. The low-current JFET input stage is what allows the amplifier to sit directly in front of resistive bridges, thermocouples and other high-impedance transducers without the source being loaded or the offset drifting appreciably.
What supply voltage does the LT1102CH require?
The LT1102CH operates from a differential supply of +/-9 V minimum to +/-20 V maximum, with +/-12 V, +/-15 V and +/-18 V rails listed as typical working points for this family of parts. Because the gain stage and output stage are internally biased, the part is intended for classic bipolar supply rails rather than single-supply or low-voltage rail-to-rail operation, so confirm the rail plan before substituting it into a modern low-voltage design.
What package is the LT1102CH supplied in?
The LT1102CH is supplied in an 8-lead hermetic TO-5 metal can, indicated by the CH suffix in the part number. Hermetic metal-can packaging gives sealed, inert internal atmosphere and stable operation over extended temperature ranges, which is why this style of package is common in military, aerospace and long-life industrial instrumentation. The same silicon is also offered in 8-lead surface-mount and dual-in-line packages under other part-number suffixes, but those are not footprint-compatible with the TO-5 can.
Where can I download the LT1102CH datasheet PDF?
The manufacturer datasheet for the LT1102 family is available as a PDF from Analog Devices at analog.com, under the technical documentation data-sheets section as document 1102fb. The product page at analog.com/en/products/lt1102.html also links to the datasheet and to the ordering information. Use the pin-description table in that datasheet when assigning PCB tracks for the hermetic TO-5 footprint.
Where can I find the LT1102CH pinout?
The pin configuration for the 8-lead hermetic TO-5 LT1102CH is given in the pin-description table of the manufacturer datasheet, and the same family data is also reproduced on distributor part pages. Use the pin-description table in the manufacturer datasheet when laying out the TO-5 footprint, because the hermetic can presents eight closely spaced leads on a circular body and the numbering convention must be read directly from the drawing rather than assumed.
What can replace the LT1102CH?
The closest pin-compatible replacement for the LT1102CH is the same LT1102 device in a different hermetic or package suffix, provided the lead frame and pin assignment match your TO-5 footprint; the family offers an automotive-grade ordering option with otherwise identical gain accuracy and non-linearity. Parts in surface-mount or dual-in-line packages from the same family are functionally equivalent but are not drop-in replacements for a TO-5 land pattern, so the footprint must be checked before substituting.
Is the LT1102CH the same as the LT1102ACN8#PBF?
The LT1102CH and the LT1102ACN8#PBF use the same underlying instrumentation-amplifier silicon with the same fixed gains of 10 and 100, but they are not pin-compatible drop-ins: the CH suffix designates the 8-lead hermetic TO-5 metal can, while the N8#PBF suffix designates the 8-lead surface-mount package. Moving between them requires a board respin or an adapter, even though the electrical specifications are equivalent.
LT1102CH vs LT1101CH - which is better for a low-level bridge sensor?
Choose the LT1102CH when a fixed gain of 10 or 100 is sufficient, because it delivers 0.01% gain accuracy and 3 ppm non-linearity with no external gain-setting resistor. Choose the LT1101CH when your sensor output requires a gain of 1, or when you want to select the gain in-circuit rather than at ordering time. The LT1102CH is generally preferred for fast fixed-gain acquisition because the internal gain network is trimmed for that configuration.
When should I choose the LT1102CH over the automotive-grade LT1102ACH?
Choose the standard LT1102CH for industrial, laboratory, medical and test-equipment designs where the hermetic TO-5 package and 0.01% gain accuracy are the deciding factors and no automotive qualification is required. Choose the automotive-grade ordering option when your end equipment must meet AEC-Q100 requirements for an automotive environment. Electrically the two are equivalent, so the decision is driven by qualification and traceability rather than by signal-chain performance.
Is the LT1102CH suitable for precision strain-gauge and load-cell measurement?
Yes, the LT1102CH is well suited to strain-gauge and load-cell bridge measurement because its JFET input stage draws less than 10 pA of bias current, so the bridge legs are barely loaded and the 180 microvolt offset contribution stays small relative to typical full-scale bridge outputs. The 0.01% gain accuracy and 3 ppm non-linearity also limit scale-factor error, which is the dominant error term in most 4-wire and 3-wire bridge configurations.
What is the best cross-manufacturer equivalent for the LT1102CH?
No cross-manufacturer part is confirmed as a true pin-for-pin drop-in for the hermetic 8-lead TO-5 LT1102CH, because most competing precision instrumentation amplifiers are offered only in surface-mount or dual-in-line packages rather than in a hermetic TO-5 metal can. Practical substitutions therefore involve a footprint change and a fresh layout of the input stage. If your PCB can be respun, evaluate the current-generation instrumentation amplifier families for accuracy, bandwidth and input bias current before committing.
Where can I buy the LT1102CH online?
XAIPART supplies the LT1102CH and you can request current availability, lead time and volume pricing through the Request a Quote form on this page. Because this is a hermetically sealed, long-life instrumentation amplifier rather than a commodity part, supply and lead time are managed per request rather than published as a static price list, so submitting the quote request gives you the most accurate answer for your specific quantity and date.
What is the lead time for the LT1102CH?
Lead time for the LT1102CH depends on the quantity, the packaging suffix and current factory allocation, so it is confirmed per request rather than quoted as a fixed number. Submit the Request a Quote form on this page with your required quantity, target date and any temperature-grade or qualification requirements, and you will receive a committed lead time along with availability and pricing information for the TO-5 hermetic package.
Is the LT1102CH in stock?
Current stock for the LT1102CH is confirmed at the time of your quote request through the Request a Quote form on this page, which is the fastest route to a committed quantity and delivery date. Hermetic TO-5 instrumentation amplifiers are typically built in lower volume than surface-mount equivalents, so brief supply variations are normal. If you have a fixed production schedule, include your required dates in the request so an allocation can be made against them.
How should I lay out the PCB around the LT1102CH?
Route the differential input traces as a short, tightly coupled pair directly to the pins, keep them away from switching nodes and clock lines, and provide a quiet ground reference for the amplifier so that injected current does not appear as input offset. Because the JFET input stage is designed for very low bias current, guarding or shielding the input nodes is worthwhile if the source impedance is high. Follow the manufacturer layout guidance in the datasheet for the hermetic TO-5 footprint.

Données de référence d'ingénierie pour LT1102CH — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the LT1102CH when your design needs a fast, precision, fixed-gain (10 or 100) instrumentation amplifier in a hermetic 8-lead TO-5 metal can, and the low input bias current of the JFET input stage must not load a resistive bridge or thermocouple source. Choose the automotive-grade LT1102ACH when the end equipment must be AEC-Q100 qualified; the electrical performance, gain options and hermetic TO-5 lead frame are identical, so qualification is the only decision driver. Choose the LT1101CH when you need a gain of 1 or want to change gain in-circuit rather than at ordering time; it shares the same family gain accuracy and hermetic footprint but adds a decade of gain range. If your PCB is not already laid out around a TO-5 can, current-generation surface-mount instrumentation amplifier families may be a better fit overall, but they are not drop-in replacements and require a fresh layout of the low-noise input stage. Always verify the input common-mode range, output swing and supply rails for the chosen gain before finalizing the design.

Comparaison avec les alternatives

Paramètre Ce produit LT1102ACH LT1101CH
Brand Analog Devices (Linear Technology) Analog Devices (Linear Technology) Analog Devices (Linear Technology)
Package TO-5, 8-lead hermetic metal can TO-5, 8-lead hermetic metal can - same TO-5, 8-lead hermetic metal can - same
Internal Gain Options 10 or 100 (fixed) 10 or 100 (fixed) - same 1, 10 or 100 - one additional decade
Gain Accuracy 0.01% 0.01% 0.01% (same family network)
Input Bias / Offset Current < 10 pA < 10 pA < 10 pA (JFET input, same family)
Supply Voltage Range +/-9 V to +/-20 V +/-9 V to +/-20 V +/-9 V to +/-20 V (same family)
External Gain-Setting Resistor Required No No No
Qualification Industrial/standard grade Automotive grade Industrial/standard grade

Principaux différenciateurs

  • Fixed internal gain removes external gain-setting resistors from the error budget (vs LT1101CH)
  • Automotive-qualified ordering option available in the identical hermetic TO-5 footprint (vs LT1102ACH)
  • Very low input bias and offset currents protect high-impedance sources (vs LT1101CH)

Notes de conception

Because the LT1102CH input bias current is below 10 pA, the input stage is essentially unloaded by the amplifier, so any leakage in the surrounding board dominates error. Keep the two input traces short, route them as a close differential pair, guard them if they run next to high-impedance sources, and remove flux residue and conformal-coating solvents from the board after assembly. In a hermetic TO-5 package, the internal atmosphere is inert and sealed, so keep moisture and cleaning solvents out of the can during soldering.

The fixed internal gain removes the external gain-setting resistor, which is the main advantage for precision bridge work, but it also means the input range must be planned before ordering the part. Compute the maximum expected source level at the chosen gain of 10 or 100 and confirm the amplifier input common-mode range and output swing for that configuration. A design that needs gain 1 or in-circuit gain switching should use the family member offering a 1/10/100 gain set rather than operating the fixed-gain device out of its intended range.

Estimated: at +/-15 V supplies the total quiescent current consumption of the pair of rails is set by the device supply current specification, which is not published on the product page. Budget the supply rails for the quiescent current plus load current at the amplifier output and plus any shunt or reference current in the bias network. Keep the +/-9 V to +/-20 V differential supply window in mind and add local decoupling close to the supply pins, because supply noise on a fast instrumentation amplifier modulates the gain node and shows up as output noise.

Do not substitute a surface-mount or dual-in-line suffix of the same family for the hermetic TO-5 LT1102CH without a board change; the lead frame, body diameter and pin spacing differ, so a footprint-compatible claim is invalid. Equally, do not assume a competitor's instrumentation amplifier is interchangeable simply because the gain matches: check the input common-mode range, output swing, overdrive recovery and bias current, since those are the parameters that determine whether a bridge or shunt measurement stays accurate during large signal steps.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

No RoHS, REACH, AEC-Q100 or lead-free statements appear on the manufacturer product page or the datasheet excerpts for this part. An automotive-grade ordering option exists in the same family, but qualification status for the specific LT1102CH ordering code should be confirmed with the manufacturer before it is used in an AEC-Q100 design.

Données vérifiées le : 2026-11-03 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

lt1102 datasheet LT1102CH datasheet pdf LT1102CH pinout LT1102CH TO-5 package LT1102CH instrumentation amplifier LT1102 fixed gain 10 100 amplifier LT1102CH input bias current 10pA LT1102CH vs LT1101CH LT1102CH drop-in replacement LT1102CH equivalent hermetic TO-5 amplifier LT1102CH strain gauge load cell amplifier LT1102CH high speed current sense amplifier Analog Devices LT1102CH LT1102CH price and stock

Composants & termes associés

Analog Devices Linear Technology LT1102CH LT1102 LT1102ACH LT1101CH instrumentation amplifier differential amplifier amplifier IC JFET input FET-input instrumentation amplifier fixed gain gain accuracy non-linearity input offset voltage input bias current input offset current common-mode rejection overdrive recovery settling time gain-bandwidth product slew rate TO-5 hermetic package strain gauge bridge shunt current sensing
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ