LT8490EUKJ Présentation

The Analog Devices LT8490EUKJ is an 80 V input, 10 A buck-boost switching battery-charge controller with maximum power point tracking, packaged in a 64-pin HVQFN. It combines wide input-voltage tolerance, multi-chemistry CCCV charging, high-current capability, and solar MPPT control in one surface-mount device. The verified distributor ordering code is LT8490EUKJ#PBF, while LT8490EUKJ#TRPBF denotes the tape-and-reel ordering option.

A buck-boost battery charger is a power-management IC that regulates charging power whether the source voltage is above or below the battery voltage. The LT8490 belongs to the switching-regulator hierarchy and supports sealed lead-acid, flooded, gel, and lithium-ion batteries. Its constant-current constant-voltage, or CCCV, profile transitions from controlled charging current to controlled battery voltage as the pack approaches its final voltage.

Key verified characteristics include an 80 V maximum input, charging capability up to 10 A, and maximum power point tracking for photovoltaic systems. The buck-boost topology allows operation when the input-to-battery voltage relationship changes during the day. This is especially useful in solar installations where irradiance, temperature, and module operating point vary throughout the charge cycle.

The device integrates the control functions needed to coordinate harvested power and battery charging rather than operating as a simple linear regulator. MPPT helps the charger seek the available solar-array maximum-power point, while CCCV manages battery chemistry and final voltage. Detailed switching frequency, accuracy, quiescent current, protection thresholds, and thermal data require confirmation in the current Analog Devices datasheet.

Typical uses include solar-powered remote instrumentation, off-grid battery systems, portable industrial equipment, renewable-energy storage, and backup power installations. These systems benefit from charging when panel voltage may be lower or higher than the battery voltage. High-current capability also supports larger battery banks where wiring, fusing, thermal design, and connector selection require careful engineering.

For implementation, verify the exposed-pad land pattern, inductor and MOSFET selection, compensation, current sensing, and thermal paths against the manufacturer datasheet. The MPPT controls and charging settings must be configured for the selected chemistry. Input transients and battery transients need protection appropriate to the installation, especially for long cable runs and outdoor photovoltaic systems.

This page combines verified distributor information, manufacturer product facts, design guidance, and honest replacement analysis. It distinguishes confirmed electrical facts from unverified parameters rather than inferring missing values, helping engineers evaluate the LT8490EUKJ for high-voltage, multi-chemistry battery charging before requesting detailed pricing.

Alternatives de remplacement direct pour LT8490EUKJ — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

LT8490EUKJ#PBF

✅ Remplacement direct
📦 HVQCN-64 (7 mm x 11 mm)
Same electrical device and HVQCN-64 package; ordering code specifies the manufacturer's packaged lead-free configuration, with no verified electrical difference.

📋 Alternative de référence (hors catalogue)

LT8490EUKJ#TRPBF

✅ Remplacement direct
📦 HVQCN-64 (7 mm x 11 mm)
Same LT8490 electrical device and HVQCN-64 package; #TRPBF specifies tape-and-reel presentation, with no verified electrical difference.

📋 Alternative de référence (hors catalogue)

LT8490EUKJ Spécifications

Device Type Buck-Boost Switching Battery Charge Controller
Maximum Input Voltage 80 V
Maximum Charge Current 10 A
Input Operating Range 1.3 V to 80 V
Charge Profile Constant-Current Constant-Voltage (CCCV)
Solar Tracking Maximum Power Point Tracking (MPPT)
Supported Battery Chemistry Sealed Lead-Acid, Flooded, Gel, and Lithium-Ion Batteries
Topologie Buck-Boost
Boîtier HVQFN-64, 7 mm x 11 mm
Nombre de broches 64 pins
Type de montage Surface Mount
Temperature Grade Automotive
Package Code HVQCCN
Surface Mount Yes

Guide de configuration des broches du LT8490EUKJ hvqccn

Configuration des broches du LT8490EUKJ (boîtier hvqccn). La numérotation des broches, les fonctions et les schémas de connexion sont définis dans la fiche technique du fabricant. Consultez-la pour l'empreinte exacte et les directives de soudage.

Schéma de brochage du boîtier hvqccn pour le LT8490EUKJ

Aucune donnée de brochage détaillée disponible pour LT8490EUKJ.

Consultez la fiche technique pour la configuration complète des broches.

Applications typiques

LT8490EUKJ convient pour 6 applications: Solar-Powered Remote Instrumentation, Off-Grid Renewable Energy Storage, Industrial Backup Power Systems, Portable Equipment Battery Charging, Renewable-Powered Data Acquisition, Backup Systems for Critical Controls.

🧩

Solar-Powered Remote Instrumentation

The LT8490EUKJ fits remote telemetry, environmental monitoring, and industrial sensor installations where a photovoltaic source may operate above or below the battery voltage during changing irradiance. Its verified 1.3 V to 80 V input range, buck-boost architecture, and MPPT support help extract available solar power while the 10 A capability supports higher-current battery platforms. Design the array against the lowest expected irradiance and highest panel temperature, then validate charge time with realistic cable and temperature losses.

⚡

Off-Grid Renewable Energy Storage

The LT8490EUKJ is suited to off-grid storage systems where renewable generation and backup sources can operate on either side of the battery voltage. Buck-boost regulation avoids restricting operation to one fixed source-to-battery polarity, while MPPT improves harvested solar energy. The 80 V input and up-to-10 A charging capability suit larger systems, but the final battery voltage, absorption behavior, and allowable charge rate must be confirmed with the battery manufacturer before enabling charging.

🏭

Industrial Backup Power Systems

An industrial backup installation can use the LT8490EUKJ to manage energy from a wide-range source while maintaining a regulated battery charge profile. CCCV operation supports the staged charging process used by multiple battery families, and the automotive-grade package marking makes the device relevant to harsh-duty designs. Qualification still requires reviewing the exact electrical grade, operating-temperature limits, isolation, fusing, fault response, and enclosure thermal performance rather than relying on package labeling alone.

📱

Portable Equipment Battery Charging

The LT8490EUKJ can support portable industrial or service equipment that must recharge from a source whose voltage varies substantially. Buck-boost operation preserves charging flexibility when the available input is below the pack voltage during one operating phase and above it during another. Up-to-10 A capability enables higher-rate packs, although portability also demands careful battery protection, connector current handling, enclosure ventilation, and chemistry-specific charge-profile validation.

📡

Renewable-Powered Data Acquisition

Data-acquisition installations in the field often combine batteries with intermittent solar power and require autonomous recharge control. The LT8490EUKJ's MPPT function, wide input range, and CCCV profile align with those needs, allowing harvested power to regulate the battery even when panel voltage changes throughout the day. Designers should calculate worst-case seasonal solar contribution, include standby-load budgeting, and protect the charger from reverse battery current and wiring-borne transients for reliable remote operation.

🖥️

Backup Systems for Critical Controls

The LT8490EUKJ is applicable to backup-energy systems serving controls, communications, or instrumentation where predictable recharge behavior is important. Constant-current charging limits the initial charging demand, while constant-voltage operation completes the charge without continuously increasing battery voltage. Mission-critical designs should add independent battery and input protection, verify fault behavior, define safe recovery procedures, and conduct thermal testing at the maximum ambient temperature and repeated full-charge load.

Récapitulatif des produits recommandés

LT3790EFE Analog Devices Utilisé dans : Solar-Powered Remote Instrumentation, Off-Grid Renewable Energy Storage LT8390EFE#PBF Analog Devices Utilisé dans : Solar-Powered Remote Instrumentation, Off-Grid Renewable Energy Storage LT4276AIUFD Analog Devices Utilisé dans : Industrial Backup Power Systems LM5069QMYKFR Related hot-swap and protection function for industrial power designs Utilisé dans : Industrial Backup Power Systems LM78210 Related low-dropout regulation for downstream low-voltage loads Utilisé dans : Portable Equipment Battery Charging LM66100 Related protection device for reverse-current and power-path control Utilisé dans : Portable Equipment Battery Charging LTC2400 Related Analog Devices low-power measurement front end Utilisé dans : Renewable-Powered Data Acquisition LTC6105 Related Analog Devices current measurement for supply diagnostics Utilisé dans : Renewable-Powered Data Acquisition ADM7150 Related low-noise regulator for sensitive downstream loads Utilisé dans : Backup Systems for Critical Controls LT3045 Related low-noise regulator for precision backup rails Utilisé dans : Backup Systems for Critical Controls
What is the LT8490EUKJ battery charger used for?
The LT8490EUKJ is an 80 V, 10 A buck-boost switching battery-charge controller for multi-chemistry battery systems. Analog Devices describes it as supporting sealed lead-acid, flooded, gel, and lithium-ion batteries with a constant-current constant-voltage charging profile. Its buck-boost architecture also allows charging when the source voltage is either above or below the battery voltage.
What are the key specifications of LT8490EUKJ that engineers should know?
The verified headline specifications of the LT8490EUKJ are an 80 V maximum input, a 1.3 V to 80 V operating input range, charging capability up to 10 A, MPPT support, and a 64-pin HVQCN package measuring 7 mm by 11 mm. The manufacturer product page and distributor records identify CCCV operation for sealed lead-acid, flooded, gel, and lithium-ion batteries.
Where can I download the LT8490EUKJ datasheet PDF?
The official LT8490 datasheet and product resources are available from the Analog Devices product page at https://www.analog.com/en/products/lt8490.html. Use that manufacturer source for the current electrical tables, pin descriptions, application circuit, recommended external components, and package drawings. The ordering suffix #PBF identifies lead-free packaged ordering information, while #TRPBF identifies tape-and-reel packaging.
Where can I find the LT8490EUKJ pinout and QFN-64 footprint?
The LT8490EUKJ pinout and land pattern should be taken from the current Analog Devices LT8490 datasheet and its 64-pin HVQCN package drawing. The distributor record identifies the package code as HVQCCN and describes a 64-terminal surface-mount package. Do not infer exposed-pad connections from generic QFN-64 examples; verify every power, signal, ground, and exposed-pad connection before layout.
Is the LT8490EUKJ suitable for solar battery charging?
Yes, the LT8490EUKJ is suitable for photovoltaic charging because it includes maximum power point tracking and operates as an 80 V buck-boost charger. MPPT is valuable when changing irradiance or module operating point causes the solar source to move above or below the battery voltage. Actual array sizing still depends on validated panel characteristics, battery voltage, charge current, temperature, and system losses.
What batteries can the LT8490EUKJ charge?
The LT8490EUKJ supports sealed lead-acid, flooded, gel, and lithium-ion batteries according to the Analog Devices product page. It uses a constant-current constant-voltage profile, but acceptable charge voltage, current, temperature limits, and termination behavior must be configured for the exact battery manufacturer. Do not apply one chemistry's settings automatically to another battery type.
Where to buy LT8490EUKJ online?
The LT8490EUKJ#PBF can be purchased through authorized distributors including DigiKey, Mouser, and LCSC. DigiKey lists LT8490EUKJ#PBF and LT8490EUKJ#TRPBF as 64-QFN multi-chemistry battery-charger options, while LCSC displayed a unit price of $32.0673 and four units in stock when the verified search was captured on 2026-10-08. Stock and price can change without notice.
What is the price of LT8490EUKJ as of 2026-10-08?
The verified LCSC listing showed LT8490EUKJ#PBF at $32.0673 per unit as of 2026-10-08. DigiKey and Mouser also provide product pages for the part, but the supplied search data did not include their numerical prices. Because distributor pricing and inventory are time-sensitive, request a current quotation before procurement and confirm the exact #PBF or #TRPBF ordering suffix.
What is the lead time and stock status of LT8490EUKJ?
LCSC showed four LT8490EUKJ#PBF units in stock when the source was retrieved on 2026-10-08, while DigiKey descriptions indicate the part can ship. The supplied data does not provide a fixed factory lead time or a current global stock count. Treat the four-unit result as historical source data and obtain a live distributor confirmation before committing a production schedule.
What is the best drop-in replacement for LT8490EUKJ?
The verified cross-reference search did not identify any manufacturer-confirmed drop-in replacement with the same HVQCN pinout and electrical behavior. Parts such as the MCP73831, BQ24650, and LTC4001 are functionally related battery-management devices but are not established pin-to-pin replacements. A PCB redesign and full charging-system revalidation are required unless the manufacturer or an authorized distributor confirms an exact substitute.
Is LT8490EUKJ the same as LTC4001?
No. The LT8490EUKJ is a 64-pin, 80 V, 10 A buck-boost charger with MPPT, while the LTC4001 is a different Analog Devices battery-controller offering. The supplied source names the LTC4001 as a functional equivalent candidate, not a verified pin-to-pin replacement. Its package, functions, voltage range, current capability, and charging algorithm must be compared before reuse.
When should I choose LT8490EUKJ over a simpler battery charger?
Choose the LT8490EUKJ when the design needs an 80 V source range, charging up to 10 A, buck-boost operation, and MPPT in a multi-chemistry controller. A simpler charger may be preferable when the source remains reliably above the battery voltage, MPPT is unnecessary, or a lower current is sufficient. The tradeoff is a complex 64-pin design with more validation and layout complexity.
LT8490EUKJ vs BQ24650: which is better for solar charging?
The LT8490EUKJ has verified MPPT support, an 80 V maximum input, and charging capability up to 10 A, while the BQ24650 is identified only as a functional equivalent candidate in the supplied source. The correct choice depends on battery chemistry, input topology, required charge current, solar control method, package, and safety requirements. The available evidence does not establish a drop-in substitution.
What are the most important design considerations for LT8490EUKJ?
The main considerations are input and battery transient protection, correct HVQCN land-pattern design, inductor and power-MOSFET selection, current-sense implementation, exposed-pad thermal management, and chemistry-specific charge settings. Because the device can reach 10 A, trace width, connectors, fusing, switching loss, copper heat spreading, and enclosure temperature require validation. Follow the current Analog Devices application guidance rather than copying low-voltage generic charger layouts.
Is LT8490EUKJ RoHS compliant or AEC-Q100 qualified?
The supplied product records identify the LT8490EUKJ#PBF package as automotive grade, but they do not provide an explicit RoHS declaration or AEC-Q100 qualification statement. The #PBF suffix commonly denotes a lead-free ordering option, but that alone is not enough to document every compliance requirement. Request the current manufacturer product declaration or material compliance report before treating the part as qualified.

Données de référence d'ingénierie pour LT8490EUKJ — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the LT8490EUKJ when a battery system needs charging from a source that may be above or below the battery voltage, solar MPPT, multi-chemistry support, and charge current up to 10 A. It is especially relevant to off-grid renewable systems and remote industrial equipment. The complexity tradeoff is substantial: the 64-pin HVQCN design requires careful external-component selection, current sensing, compensation, protection, thermal management, and chemistry-specific validation. The supplied cross-reference results do not establish any different manufacturer or controller as a pin-to-pin drop-in replacement. MCP73831, BQ24650, and LTC4001 were mentioned as functional candidates, but each requires a separate engineering comparison. For an existing LT8490 board, verify whether LT8490EUKJ#PBF or LT8490EUKJ#TRPBF is the correct packaged ordering suffix. For a new design with simpler source polarity, lower current, or no MPPT requirement, a simpler charger may reduce cost and design effort.

Comparaison avec les alternatives

Paramètre Ce produit LT8490EUKJ#PBF LT8490EUKJ#TRPBF
Brand Analog Devices Analog Devices Analog Devices
Package HVQCN-64 (7 mm x 11 mm) HVQCN-64 (7 mm x 11 mm) HVQCN-64 (7 mm x 11 mm)
Maximum Input Voltage 80 V 80 V 80 V
Input Operating Range 1.3 V to 80 V 1.3 V to 80 V 1.3 V to 80 V
Maximum Charge Current 10 A 10 A 10 A
Topology Buck-Boost Buck-Boost Buck-Boost
Charging Profile CCCV CCCV CCCV
Solar MPPT Supported Supported Supported
Supported Battery Chemistries Sealed Lead-Acid, Flooded, Gel, and Lithium-Ion Sealed Lead-Acid, Flooded, Gel, and Lithium-Ion Sealed Lead-Acid, Flooded, Gel, and Lithium-Ion
Ordering Presentation Base MPN; #PBF and #TRPBF identified as distributor order codes #PBF ordering code #TRPBF tape-and-reel ordering code

Principaux différenciateurs

  • Wide buck-boost charging input range (vs Typical fixed-polarity buck chargers)
  • Photovoltaic optimization is integrated (vs Basic CCCV chargers without MPPT)
  • Multi-chemistry integration (vs Single-chemistry charge controllers)
  • High-current charging in a compact surface-mount package (vs Lower-current charger ICs)

Notes de conception

Treat the HVQCN exposed pad as the primary thermal and electrical land. Use the manufacturer land pattern and thermal data rather than assuming that the exposed pad is only mechanical. Estimated: converter loss depends on input voltage, output voltage, charge current, switching frequency, and component efficiency, none of which were supplied, so a defensible junction-temperature calculation cannot be completed from the verified data. Validate worst-case ambient, repeated full-current charging, copper area, and enclosure temperature.

Route the high-current input, switch-node, inductor, sense, and battery paths with short, wide copper paths while keeping sensitive control and MPPT signals away from switching nodes. Place input, switching, and capacitor connections according to the current Analog Devices application circuit. Validate creepage, clearance, input surge protection, fusing, and connector current ratings for an 80 V system; low-voltage board-design assumptions are not appropriate.

Set charge current and voltage only from the battery manufacturer's specified limits, then verify fault and restart behavior for disconnected batteries, cold conditions, and open-current-sense conditions. The verified 10 A maximum does not mean every battery or enclosure can accept 10 A. Check MOSFET voltage and current ratings, inductor saturation current, shunt dissipation, trace heating, fuse coordination, and reverse-current behavior during system shutdown.

Do not treat MPPT as an automatic guarantee of maximum harvested energy. Panel sizing, orientation, partial shading, calibration limits, and ambient temperature can reduce available power. A multi-string array may also require per-string blocking or bypass decisions outside this single-controller solution. Validate MPPT behavior across the expected solar-module curve and confirm that a three-stage lead-acid profile or lithium charge method is configured correctly.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

The verified distributor record identifies LT8490EUKJ#PBF and an automotive temperature grade, but no explicit RoHS, REACH, AEC-Q100, halogen-free, or conflict-minerals declarations were supplied. Confirm these claims using current Analog Devices documentation before procurement.

Recherches associées

LT8490EUKJ LT8490EUKJ datasheet PDF Analog Devices LT8490EUKJ LT8490EUKJ 80V 10A charger LT8490EUKJ HVQCN-64 pinout LT8490EUKJ MPPT solar charger LT8490EUKJ vs LTC4001 LT8490EUKJ vs BQ24650 LT8490EUKJ drop-in replacement LT8490EUKJ buy online LT8490EUKJ price LT8490EUKJ lead time and stock

Composants & termes associés

Analog Devices LT8490EUKJ LT8490EUKJ#PBF LT8490EUKJ#TRPBF LT8490 Battery Charger Buck-Boost Switching Regulator Power Management IC Battery Management Constant-Current Constant-Voltage CCCV Maximum Power Point Tracking MPPT Sealed Lead-Acid Battery Flooded Lead-Acid Battery Gel Battery Lithium-Ion Battery HVQCN-64 QFN Package Family Surface-Mount Device Solar Charging Off-Grid Power System Inductor Power MOSFET Automotive-Grade Packaging
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ