Analog Devices

LTC2947IUHF-65#PBF - 65A Power/Energy Monitor | Analog Devices

Référence : LTC2947IUHF-65#PBF ✓ Actif
En stock Expédié sous 1 à 3 jours ouvrés
0 V to 15 V Vdss -65 A to +65 A Id 38-QFN, 5 mm × 7 mm Package Internal or external clock options Speed
À partir de $7.94 USD / unité
MOQ : 1 |
Prix mis à jour : 2026-10-20
Tarifs dégressifs
Qté Prix unitaire Total
1 $12.85 $12,85
10 $11.74 $117,40
100 $9.98 $998,00
500 $8.86 $4 430,00
1 000 $7.94 $7 940,00
ℹ️ Tous les prix sont en USD

LTC2947IUHF-65#PBF Présentation

Analog Devices LTC2947IUHF-65#PBF is a ±65 A single-phase power and energy monitor with an integrated sense resistor, three internal delta-sigma ADCs, and a 38-QFN 5 mm × 7 mm surface-mount package. It measures voltage from 0 V to 15 V, current from -65 A to +65 A, and power from -975 W to +975 W, while supporting energy accumulation and I2C or SPI digital access. Its integrated high-current sense element simplifies metered power paths by eliminating a separate current-sense resistor.

A power and energy monitor measures electrical quantities inside a load path and exposes them digitally for telemetry, diagnostics, energy billing, or control. This device sits in the power-management hierarchy as an energy-metering IC, current monitor, and power monitor. Unlike a general-purpose analog-to-digital converter, the LTC2947-65 combines voltage acquisition, bidirectional current acquisition, real-time power multiplication, and accumulated energy in one dedicated instrument.

Verified product information highlights the device's ±65 A current capability, three no-latency delta-sigma ADCs, and analog voltage-current multiplication. Its broad measurement range allows one monitor to cover positive consumption, reverse current, and high-current system buses. The manufacturer describes the LTC2947-65 family as a high-precision power and energy meter, while distributor records identify LTC2947IUHF-65#PBF as a single-phase meter IC in a 38-QFN package.

The monitor supports internal or external clocking for precise, selectable integration intervals. Digital configuration permits a host processor or energy-metering controller to retrieve measurements over I2C or SPI. This makes the device useful where an embedded controller must observe demand, detect overload conditions, record consumption, or expose operating data through a communications bus without building a discrete shunt and analog front end.

Typical installations place the integrated current path in series with a high-current DC supply while the voltage measurement network senses the monitored bus. The 0 V to 15 V voltage range is suited to common low-voltage power rails, and the -65 A to +65 A current range supports chargers, battery systems, industrial supplies, test equipment, and power-distribution modules. Because measured power can reach -975 W to +975 W, designers should select connectors, PCB copper, and thermal construction for the full operating current rather than only the nominal metering range.

The main design consideration is Kelvin routing: voltage and current sense connections should follow the manufacturer's layout guidance so high-current copper drops do not become part of the measurement error. Decoupling must be implemented according to the manufacturer datasheet, and the exposed thermal feature should be connected to suitable PCB copper. Verify the complete pinout and exposed-pad requirements on the official LTC2947-65 documentation before layout release.

This page combines manufacturer product information with distributor availability and packages verified drop-in alternatives only where exact pin compatibility can be established. It also adds engineering-oriented comparisons, PCB cautions, and selection guidance that are not visible in a basic distributor catalog listing.

Alternatives de remplacement direct pour LTC2947IUHF-65#PBF — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Variantes de cette série

Modèles de la même série directement compatibles avec LTC2947IUHF-65#PBF (même facteur de forme et même empreinte) — différant par Operating Temperature Range, Package.

Analog Devices
Operating Temperature Range: -40 C to +85 C (Industrial)
Package: 38-QFN (5 mm x 7 mm) with exposed pad
Comparer avec LTC2947IUHF-65#PBF →

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

Aucune alternative de remplacement direct disponible pour ce produit.

Demander des alternatives

LTC2947IUHF-65#PBF Valeurs maximales et caractéristiques électriques

Product Type Single-phase power and energy monitor IC
Current Measurement Range -65 A to +65 A
Voltage Measurement Range 0 V to 15 V
Power Measurement Range -975 W to +975 W
Integrated Sense Resistor 65 A internal sense resistor
ADC Architecture 3 internal No Latency delta-sigma ADCs
Power Calculation Method High-bandwidth analog multiplication of voltage and current
Digital Interface I2C or SPI
Clocking Internal or external clock options
Boîtier 38-QFN, 5 mm × 7 mm
Package Code HVQCCN
Type de montage Surface mount
Terminal Count 38 terminals
Package Shape Rectangular
Plage de température de fonctionnement -40°C to +125°C
Recommended Operating Temperature Range 0°C to 85°C for optimal performance and accuracy
Temperature Grade Industrial
PBF Packaging Indicator Lead-free part designation

Guide de configuration des broches du LTC2947IUHF-65#PBF rectangular

Configuration des broches du LTC2947IUHF-65#PBF (boîtier rectangular). Ce composant de puissance comporte des bornes de grille, de drain et de source. Pour les boîtiers non polarisés, consultez la fiche technique du fabricant pour l'orientation exacte de la broche 1 et les détails de l'empreinte. Les applications courantes incluent la conception d'alimentations, la commande de moteurs et la commutation de charges.

Schéma de brochage du boîtier rectangular pour le LTC2947IUHF-65#PBF

Aucune donnée de brochage détaillée disponible pour LTC2947IUHF-65#PBF.

Consultez la fiche technique pour la configuration complète des broches.

Applications typiques

LTC2947IUHF-65#PBF convient pour 6 applications: Battery Charging and Energy Storage, Industrial DC Power Supply Monitoring, Server and Data-Center Power Distribution, Power-Distribution Modules and Load Switches, Test and Measurement Systems, EV Charging and Mobile Power Systems.

⚡

Battery Charging and Energy Storage

LTC2947IUHF-65#PBF fits battery systems that need both charge and reverse-current visibility. Its -65 A to +65 A range captures opposite current directions, while the 0 V to 15 V measurement range covers many low-voltage packs. The integrated 65 A sense resistor simplifies the high-current path, and the ±975 W power range provides telemetry for host-side charge control and logging. Engineers must still add charger, cell protection, fusing, and fault-current handling, and must follow the manufacturer Kelvin layout to keep copper resistance from degrading accuracy.

🏭

Industrial DC Power Supply Monitoring

The LTC2947IUHF-65#PBF can monitor a low-voltage industrial DC bus when nominal voltage is no greater than the specified 15 V measurement ceiling and operating current is no greater than 65 A in magnitude. Three internal delta-sigma ADCs and analog power multiplication provide the measurements needed for load diagnostics, energy accounting, and host alarms. The industrial temperature grade is useful, although the supplied source recommends 0°C to 85°C for best performance. PCB busbars, copper width, connectors, and ambient-temperature derating remain critical at sustained high current.

🖥️

Server and Data-Center Power Distribution

LTC2947IUHF-65#PBF is suitable for a power-distribution module that must measure high-current DC input and expose energy data to a supervisory controller. Its integrated sense resistor avoids a discrete shunt, and I2C or SPI provides a digital path to a power-management microcontroller. The measurement envelope of -65 A to +65 A covers substantially more than many board shunts, although the 0 V to 15 V monitored range may require an appropriate interface for higher-voltage systems. Redundancy, isolation, hot-swap behavior, and fault response must be designed at the system level.

🔧

Power-Distribution Modules and Load Switches

The LTC2947IUHF-65#PBF can be integrated into a monitored power-distribution module where downstream load, fault status, and accumulated energy must be visible to a controller. Its three internal ADCs support voltage and bidirectional current measurement, while analog multiplication avoids relying only on sampled software multiplication. With a current measurement range of ±65 A and a power range of ±975 W, it targets substantial low-voltage loads. Placement next to the high-current path is important because long, narrow copper runs increase voltage loss and heat, and Kelvin connections must reference the intended sense points.

📺

Test and Measurement Systems

LTC2947IUHF-65#PBF fits laboratory power-test fixtures that need digital voltage, current, power, and energy readings. The bidirectional ranges allow the same instrument channel to observe forward load, reverse discharge, or regeneration, while internal or external clocking supports repeatable energy integration. A host computer can read results through I2C or SPI and log them over time. Calibration strategy, sense-path layout, fixture parasitics, and the 15 V measurement ceiling should be established before test limits are defined.

📱

EV Charging and Mobile Power Systems

LTC2947IUHF-65#PBF is relevant to portable and vehicle-like power systems that combine high-current charging with energy accounting. Its ±65 A range supports substantial DC paths, and the integrated 65 A sense resistor helps reduce the number of high-current sensing components. The device can report load behavior to a charging controller through I2C or SPI, enabling logging, thermal management, and fault detection. It does not enforce current limits or provide vehicle isolation by itself, so automotive qualification, contactors, precharge, insulation, and safety controls must be supplied elsewhere.

What are the key specifications of LTC2947IUHF-65#PBF that engineers should know?
The LTC2947IUHF-65#PBF measures -65 A to +65 A, 0 V to 15 V, and -975 W to +975 W in a 38-QFN 5 mm × 7 mm package. Analog Devices identifies the device as a high-precision power and energy monitor with an integrated 65 A sense resistor. Three internal No Latency delta-sigma ADCs acquire the quantities used for measurement, while high-bandwidth analog multiplication produces the power result. I2C and SPI access support embedded metering systems.
What is the operating voltage range of LTC2947IUHF-65#PBF?
The monitored voltage range of LTC2947IUHF-65#PBF is 0 V to 15 V. This is the voltage measurement range described on the Analog Devices LTC2947-65 product page, not a claim that the device can safely connect its supply pins to every voltage in that range. The complete power-path and supply-pin limits must be taken from the manufacturer datasheet. Use the product's recommended 0°C to 85°C operating interval when its best stated accuracy is required.
What is the current measurement range of LTC2947IUHF-65#PBF?
The LTC2947IUHF-65#PBF measures bidirectional current from -65 A to +65 A. The negative portion captures reverse flow, while the positive portion covers forward load current. Analog Devices states that the integrated 65 A sense resistor and internal current ADC support this range. PCB traces, terminations, connectors, and thermal design must still handle the maximum sustained current and fault energy expected in the completed system.
Where can I download the LTC2947IUHF-65#PBF datasheet PDF?
The authoritative starting point is the Analog Devices LTC2947-65 product page at https://www.analog.com/en/products/ltc2947-65.html, which links to the device documentation and product resources. The same family datasheet is also indexed through third-party datasheet services. Use the Analog Devices resource for the final pinout, electrical limits, layout requirements, and accuracy details, because distributor summaries do not contain every value needed for a production design.
Where can I find the LTC2947IUHF-65#PBF pinout?
The LTC2947IUHF-65#PBF pinout is published in the Analog Devices manufacturer documentation for the LTC2947-65 family. The verified distributor data identifies a 38-terminal HVQCCN QFN package measuring 5 mm × 7 mm. A complete, pin-by-pin map cannot be reproduced safely from the search excerpts provided, so consult the manufacturer datasheet and land pattern before assigning nets or designing exposed-pad connections.
Can LTC2947IUHF-65#PBF measure reverse current and negative power?
Yes, LTC2947IUHF-65#PBF is specified for -65 A to +65 A current measurement and -975 W to +975 W power measurement. Bidirectional capability distinguishes it from basic positive-current monitors and makes it useful for battery charging, regeneration, energy-control, and bidirectional test systems. Confirm that the mechanical current path, host software, sign convention, and protection hardware are designed for reverse-current operation as well as forward load.
Is LTC2947IUHF-65#PBF suitable for battery charging and energy metering?
LTC2947IUHF-65#PBF is suitable when the design requires high-current bidirectional monitoring. Its 0 V to 15 V measurement range, ±65 A current range, and ±975 W power range cover common low-voltage battery buses, while digital I2C or SPI access supports host-side logging and control. The IC is a measurement element rather than a complete charger, so cell chemistry, protection, switching, calibration, and safety controls remain separate system responsibilities.
Where to buy LTC2947IUHF-65#PBF online?
LTC2947IUHF-65#PBF is listed by authorized distributors including DigiKey, Mouser, and Analog Devices. DigiKey describes it as available to ship and Mouser lists the 65 A+ power and energy monitor with datasheet, inventory, and pricing information. XAIPART pricing is shown as of 2026-10-21, but live stock and delivered pricing can change. Confirm the exact suffix, package, quantity, authorized-channel status, and lead time before placing an order.
What is the price of LTC2947IUHF-65#PBF?
The listed XAIPART unit price for one LTC2947IUHF-65#PBF is 12.85 USD as of 2026-10-21, with lower prices shown at 10, 100, 500, and 1000 units. These are commercial reference tiers, not a guarantee of distributor stock or identical authorized-channel terms. High-current integrated-sense-resistor meters can have meaningful price sensitivity, so request a formal quote for production quantities and compare delivery, traceability, and warranty terms.
What is the lead time and stock status for LTC2947IUHF-65#PBF?
The verified distributor result says LTC2947IUHF-65#PBF can ship today, but it does not provide a quantified manufacturer lead time or a quantity-specific stock count. Treat availability as changing rather than permanent and confirm the requested quantity directly with the seller. XAIPART's Product JSON-LD uses BackOrder because the supplied evidence does not establish XAIPART inventory. Contact the distributor for allocation, customs, and production scheduling information.
What can replace LTC2947IUHF-65#PBF?
A valid replacement must match the 38-QFN 5 mm × 7 mm footprint, preserve pin connectivity, and provide compatible I2C or SPI metering functions and measurement ranges. The supplied cross-reference search did not identify five verified drop-in alternatives, and reel or packaging-code variants were not counted. A base-model family change or similarly named meter is not automatically drop-in because current range, pins, address behavior, calibration, and exposed-pad requirements may differ.
Is LTC2947-65 the same as LTC2947IUHF-65#PBF?
LTC2947-65 names the 65 A monitor family, while LTC2947IUHF-65#PBF identifies a specific ordering code that includes package and lead-free information. They are related, but the complete ordering-code datasheet must be checked before treating one as interchangeable with another suffix. Pin compatibility, temperature grade, package dimensions, and exposed-pad requirements must all match; the family relationship alone does not prove drop-in replacement.
When should I choose LTC2947IUHF-65#PBF over a lower-current energy monitor?
Choose LTC2947IUHF-65#PBF when bidirectional current up to ±65 A and power up to ±975 W are genuine system requirements. Its integrated 65 A sense resistor removes the need for a discrete shunt and associated Kelvin measurement network, which can simplify metered high-current designs. A lower-current monitor may be preferable when cost, PCB area, or supply requirements dominate, but only after confirming peak load, fault behavior, accuracy, and thermal requirements.
Is LTC2947IUHF-65#PBF suitable for industrial power supplies?
LTC2947IUHF-65#PBF can fit industrial power-supply monitoring where the bus is within its 0 V to 15 V measurement range and load current remains within ±65 A. Its -40°C to +125°C operating range supports temperature headroom, although the retrieved source recommends 0°C to 85°C for optimal performance and accuracy. Industrial qualification also requires checking EMC, surge, functional-safety, environmental, and compliance requirements not stated in the supplied data.
What is the best Analog Devices equivalent for LTC2947IUHF-65#PBF?
No distinct Analog Devices drop-in equivalent is verified in the supplied cross-reference results. LTC2947-65 is the manufacturer family associated with the target, but it is not counted as an alternative without proof that a particular ordering code is pin-to-pin compatible. Analog Devices LTC2947 and LTC2947-65 pages provide the appropriate starting points for approved variants. Do not assume a lower-current sense-resistor option is interchangeable.
What thermal and PCB considerations apply to LTC2947IUHF-65#PBF?
A 65 A integrated current path makes PCB copper, interconnects, and thermal design as important as measurement accuracy. Route the high-current path for low voltage drop and use the manufacturer's Kelvin-sensing pattern to exclude copper drops from the measurement path. Provide the specified bypass capacitors, observe current-density and temperature-rise limits, and thermally couple the exposed pad as directed. Because junction resistance and maximum dissipation were not supplied, no unsupported thermal calculation is presented.
Does LTC2947IUHF-65#PBF support RoHS, REACH, or automotive qualification?
The provided evidence establishes an industrial temperature grade and a #PBF ordering designation, but it does not explicitly state RoHS, REACH, or AEC-Q100 status. Those fields therefore remain unknown rather than being inferred from the suffix. The Analog Devices product page and current manufacturer compliance documentation should be consulted before procurement. Automotive use requires documented AEC-Q100 qualification rather than merely an industrial temperature rating.

Données de référence d'ingénierie pour LTC2947IUHF-65#PBF — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose LTC2947IUHF-65#PBF when a low-voltage, high-current path requires bidirectional voltage, current, power, and energy monitoring without a discrete shunt. Its integrated 65 A sense resistor, ±65 A current range, ±975 W power range, and I2C/SPI access are compelling for battery, charger, industrial-supply, and test-system telemetry. A lower-current or external-shunt meter may be preferable when the load is small, cost dominates, or a wider monitored-voltage range is required. Do not select a nominal cross without confirming the exact 38-QFN footprint, pinout, package code, exposed pad, temperature grade, digital interface, and calibration behavior. The supplied cross-reference search produced no verified drop-in alternatives, so maintaining an existing LTC2947 design is safer than assuming an unlisted competitor is interchangeable.

Comparaison avec les alternatives

Paramètre Ce produit
Package 38-QFN, 5 mm × 7 mm
Brand Analog Devices
Current Measurement Range -65 A to +65 A
Voltage Measurement Range 0 V to 15 V
Power Measurement Range -975 W to +975 W
Current Sensing Integrated 65 A sense resistor
ADC Architecture 3 internal No Latency delta-sigma ADCs
Digital Interface I2C or SPI
Operating Temperature Range -40°C to +125°C; 0°C to 85°C recommended for optimal performance and accuracy
Temperature Grade Industrial

Principaux différenciateurs

  • High-current sensing is integrated into the meter (vs Discrete shunt-and-ADC designs)
  • Bidirectional power measurement covers regeneration (vs Unidirectional current monitors)
  • Power is calculated with dedicated analog multiplication (vs Host-computed power measurements)
  • Three measurement ADCs support an integrated energy-metering channel (vs Single-channel analog monitors)

Notes de conception

Use the manufacturer reference layout and Kelvin-routing pattern so the voltage measurement references the intended copper nodes rather than the voltage drop across the package or PCB current path. At ±65 A, even a small trace resistance can create a meaningful measurement error and heat. Keep sense traces away from high-current switching nodes, minimize loop area, and verify the exposed-pad connection against the official land pattern before fabrication.

Treat copper loss, connector loss, and IC dissipation as a coupled thermal design problem. The integrated 65 A sense path removes an external shunt but does not eliminate heat in the PCB and package. Use the manufacturer limits for continuous current, pulse current, junction temperature, and exposed-pad construction; those detailed values were not present in the supplied excerpts. Avoid estimating allowable rise from package size alone, and derate current when ambient temperature or airflow is unfavorable.

Place input and output bypass capacitors where the manufacturer datasheet directs, maintain short high-current paths, and provide adequate copper around all connected terminals. Inspect whether terminals, exposed pads, and lead-free package dimensions match the exact IUHF ordering code. Because no verified public pin list was included in the prompt, do not assign nets from package-count assumptions; cross-check every terminal against the official datasheet and footprint.

Do not confuse the 0 V to 15 V monitored bus range with the complete list of allowable supply-pin voltages, or assume all ±65 A operating conditions are safe for arbitrary PCB layouts. Also do not infer RoHS, REACH, or AEC-Q100 compliance from the #PBF suffix. Check absolute maximum ratings, recommended operating conditions, current derating, exposed-pad handling, and lifecycle status using the current Analog Devices documentation.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sans plomb
Yes
Sans halogène
Unknown
Minerais de conflit
Unknown

The #PBF ordering designation supports lead-free status, but the supplied evidence does not explicitly document RoHS, REACH, halogen-free, conflict-minerals, or AEC-Q100 status. The industrial temperature grade does not establish automotive qualification.

Recherches associées

LTC2947IUHF-65#PBF LTC2947IUHF-65#PBF datasheet Analog Devices LTC2947-65 65A bidirectional power monitor 38-QFN 5x7 energy monitor integrated sense resistor 65A IC LTC2947-65 battery energy metering LTC2947-65 industrial power supply monitor LTC2947-65 pinout and footprint LTC2947IUHF-65#PBF price LTC2947IUHF-65#PBF buy online LTC2947IUHF-65#PBF drop-in replacement 65A I2C SPI power energy monitor LTC2947-65 Kelvin current sensing layout

Composants & termes associés

Analog Devices Linear Technology LTC2947IUHF-65#PBF LTC2947-65 power and energy monitor energy-metering IC current monitor power monitor integrated sense resistor delta-sigma ADC No Latency ADC analog multiplication I2C SPI bidirectional current measurement power measurement energy accumulation 38-QFN HVQCCN QFN package family surface-mount package Kelvin sensing lead-free packaging battery charging industrial power supply
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ