MAX115CAX Présentation

The Maxim Integrated MAX115CAX (now under Analog Devices) is a high-speed, multi-channel, 12-bit data-acquisition system (DAS) with simultaneous track/hold (T/H) amplifiers, packaged in a 36-pin SSOP. It integrates four simultaneous-sampling T/Hs with two multiplexed inputs each (eight single-ended inputs total), a 2us successive-approximation ADC, a +2.5V internal reference, and a buffered reference input that preserves the relative phase information of the sampled signals for powerline monitoring and three-phase motor control.

A Data Acquisition System (DAS) is an integrated analog front-end that combines signal conditioning, multiplexing, sample-and-hold, and analog-to-digital conversion on a single IC, sitting hierarchically as: ADC -> data converter -> data acquisition IC -> signal chain -> mixed-signal subsystem. The simultaneous-sampling T/H topology distinguishes DAS from generic ADCs by capturing phase-coherent snapshots across channels at the exact same instant, critical for vector calculations on multi-axis systems where timing skew would corrupt computed magnitudes.

Key features include 2us conversion time per channel, throughput up to 390 ksps for one channel, 218 ksps for two, 152 ksps for three, and 116 ksps for all four channels, plus a parallel interface whose access and bus-release timing is compatible with most 16-bit and 32-bit DSPs and microprocessors. Per-channel programmable gain and bipolar input ranges (driven by the +2.5V reference) allow direct interface with ±5V or 0-5V transducers without external signal conditioning.

The architecture pairs a successive-approximation register (SAR) ADC core with four dedicated T/H capacitors and dual 4-to-1 input MUXes, sequenced by the on-chip state machine. The internal +2.5V reference (with buffered output for external use) provides ratiometric measurement capability, and the parallel data bus minimizes read latency for closed-loop control loops running on a host processor.

Typical applications include three-phase power metering and power-quality monitoring, multi-axis motor control and robotics, vibration analysis and modal testing, and multi-channel data loggers for industrial process instrumentation. The 36-SSOP footprint suits medium-density analog boards where 4-8 simultaneous channels must be acquired without time-skew artifacts.

When designing with this device, budget the ORDE active-high enable and power-down mode for sleep current in battery-aware deployments, and decouple AVDD/DVDD with separate 10uF + 0.1uF pairs as close to the pins as possible.

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet.

Alternatives de remplacement direct pour MAX115CAX — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

MAX115CAX+T

✅ Remplacement direct
📦 36-SSOP
same die/package, lead-free tape and reel RoHS variant

📋 Alternative de référence (hors catalogue)

MAX115EAX

✅ Remplacement direct
📦 36-SSOP
extended temp grade -40C to +85C vs commercial 0C to +70C

📋 Alternative de référence (hors catalogue)

MAX115CAX-T

✅ Remplacement direct
📦 36-SSOP
same die, tape & reel of -20012 industrial temp grade variant

📋 Alternative de référence (hors catalogue)

MAX115CEAX

✅ Remplacement direct ⚠️ Spécifications non vérifiées
📦 36-SSOP
same die, alternate ordering code for commercial temp grade

📋 Alternative de référence (hors catalogue)

MAX115CAX+

✅ Remplacement direct
📦 36-SSOP
same die, lead-free RoHS commercial temp grade ordering code

📋 Alternative de référence (hors catalogue)

MAX115CAX Valeurs maximales et caractéristiques électriques

Résolution 12 bits
Number of Channels 8 (2x4 simultaneous-sampling T/H + 2x MUX)
Conversion Time 2 us per channel
Throughput (1 ch) 390 ksps
Throughput (2 ch) 218 ksps
Throughput (3 ch) 152 ksps
Throughput (4 ch) 116 ksps
Architecture SAR ADC with simultaneous track/hold
Input Type Single-ended, bipolar (programmable gain)
Internal Reference +2.5 V
Reference Output Buffered, available externally
Data Interface Parallel
Boîtier 36-SSOP
Type de montage Surface Mount

Configuration des broches de MAX115CAX

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Broche 1 CH1+ — Channel 1 positive analog input
Broche 2 CH1- — Channel 1 negative analog input
Broche 3 CH2+ — Channel 2 positive analog input
Broche 4 CH2- — Channel 2 negative analog input
Broche 5 AGND — Analog ground
Broche 6 CH3+ — Channel 3 positive analog input
Broche 7 CH3- — Channel 3 negative analog input
Broche 8 CH4+ — Channel 4 positive analog input
Broche 9 CH4- — Channel 4 negative analog input
Broche 10 AGND — Analog ground
Broche 11 MUX0 — Multiplexer select 0 (auxiliary input A/B selection)
Broche 12 MUX1 — Multiplexer select 1
Broche 13 AVDD — Analog supply voltage
Broche 14 AVDD — Analog supply voltage
Broche 15 AVSS — Analog negative supply
Broche 16 REF — +2.5V reference input/output
Broche 17 REFGND — Reference ground
Broche 18 DVDD — Digital supply voltage
Broche 19 DGND — Digital ground
Broche 20 CONVST — Conversion start (active low)
Broche 21 RD — Read strobe (active low)
Broche 22 CS — Chip select (active low)
Broche 23 INT — Interrupt output (active low)
Broche 24 PD — Power-down mode (active high)
Broche 25 D0 — Data bit 0 (LSB)
Broche 26 D1 — Data bit 1
Broche 27 D2 — Data bit 2
Broche 28 D3 — Data bit 3
Broche 29 D4 — Data bit 4
Broche 30 D5 — Data bit 5
Broche 31 D6 — Data bit 6
Broche 32 D7 — Data bit 7
Broche 33 D8 — Data bit 8
Broche 34 D9 — Data bit 9
Broche 35 D10 — Data bit 10
Broche 36 D11 — Data bit 11 (MSB)

Applications typiques

MAX115CAX convient pour 6 applications: Three-Phase Power Metering and Power Quality Monitoring, Multi-Axis Motor Control and Robotics, Vibration Analysis and Modal Testing, Multi-channel Industrial Data Loggers, Battery Management System (BMS) Cell Monitoring, Medical Patient Monitoring and Diagnostic Equipment.

⚡

Three-Phase Power Metering and Power Quality Monitoring

The MAX115CAX's four simultaneous-sampling track/hold amplifiers capture phase-A, phase-B, and phase-C voltage and current waveforms at the exact same instant, eliminating the inter-channel time-skew that would otherwise corrupt real-power (P = V I X cos(theta)) and reactive-power (Q = V I X sin(theta)) calculations in three-phase energy meters and class-0.5 power-quality analyzers. With 12-bit resolution, 116 ksps aggregate throughput, and a +2.5V internal reference that scales the ADC transfer function ratiometrically, the device delivers adequate dynamic range for fundamental and harmonic content up to the 50th harmonic when the per-channel throughput is reduced through oversampling. The parallel digital bus minimizes read latency for the host DSP or microprocessor performing FFT-based harmonic analysis and RMS calculations in real time, and the bipolar input range allows direct interface to current-transformer (CT) and potential-transformer (PT) secondary outputs without external signal conditioning.

🏭

Multi-Axis Motor Control and Robotics

Vector-controlled (FOC) AC motor controllers and multi-DOF robotic arms require phase-coherent sampling of stator current feedback from multiple shunt resistors or Hall-effect sensors to compute the Park/Clarke transform d-q axis currents at a single instant in time. The MAX115CAX's simultaneous T/H topology provides exactly that capability with 2us per-channel conversion and 116 ksps aggregate when all four axes are active, suitable for sub-10 kHz FOC update loops on industrial servo drives and CNC spindle controllers. The programmable bipolar input range accepts +/-5V or 0-5V Hall-sensor outputs directly, while the parallel interface ties cleanly into a TI C2000 or ARM Cortex-M4 host processor's external memory bus with minimum glue, accelerating control-loop latency.

✈️

Vibration Analysis and Modal Testing

Modal-testing impact hammers and shakers simultaneously excite and measure structural responses at multiple accelerometer locations, requiring phase-coherent acquisition to compute transfer functions (H1, H2, H3 estimators) and modal shapes (mode shapes, damping ratios, natural frequencies) without bias from inter-channel time delay. The MAX115CAX samples four accelerometer channels with sub-microsecond inter-channel skew, and its 12-bit resolution provides ~72 dB dynamic range - adequate for FRF measurement on automotive body-in-white, aerospace panel, and civil-engineering bridge structures when paired with ICP-type IEPE accelerometers. The buffered +2.5V reference drives the accelerometer excitation current source directly, and the parallel data output streams four channels into a host FFT analyzer without bus-arbitration overhead.

🏭

Multi-channel Industrial Data Loggers

Process-control data loggers that record temperature, pressure, flow, and level signals from 4-20mA loops or 0-10V transducer outputs require simultaneous sampling across channels to capture transient process upsets (pump startups, valve closures, controller-mode changes) without time-skew artifact. The MAX115CAX integrates eight single-ended inputs via two 4-to-1 MUXes feeding four simultaneous T/Hs, allowing flexible channel-count scaling without an external MUX. The 12-bit resolution is sufficient for 0.1% FS process transmitters, and the parallel bus supports onboard data buffering into SRAM or direct streaming to non-volatile memory for remote telemetry.

🔋

Battery Management System (BMS) Cell Monitoring

Multi-cell battery stacks in EVs, grid storage, and UPS systems require simultaneous sampling of all series cell voltages during load transients (regenerative braking, load steps) to compute state-of-charge (SOC) and state-of-health (SOH) without aliasing the dynamic load profile. The MAX115CAX samples four cells per IC, scaling to 12S, 16S, or larger packs by stacking additional MAX115CAX devices with synchronized CONVST pulses. The +2.5V internal reference provides adequate accuracy for cell balancing decisions, and the parallel bus allows rapid host readback during the brief sampling window at the beginning of each PWM cycle.

💊

Medical Patient Monitoring and Diagnostic Equipment

Multi-lead ECG, EEG, EMG, and patient-monitoring equipment require phase-locked sampling across 4-8 leads to compute vectorcardiogram (VCG) loops, derive heart-rate variability (HRV) from R-R interval statistics, and reject common-mode 50/60 Hz interference through synchronous digital filtering. The MAX115CAX's simultaneous T/H topology preserves phase coherence across leads, which is essential for accurate VCG reconstruction from orthogonal lead sets (X, Y, Z). The +2.5V reference and bipolar inputs allow direct connection to instrumentation-amplifier outputs from ECG/EEG front-ends, and the parallel bus minimizes host-processor overhead for real-time arrhythmia detection.

Récapitulatif des produits recommandés

MAX115CAX+T Lead-free RoHS same-die variant for new designs Utilisé dans : Three-Phase Power Metering and Power Quality Monitoring, Multi-Axis Motor Control and Robotics, Vibration Analysis and Modal Testing, Battery Management System (BMS) Cell Monitoring MAX115EAX Extended-temperature grade for industrial meters Utilisé dans : Three-Phase Power Metering and Power Quality Monitoring, Multi-Axis Motor Control and Robotics, Multi-channel Industrial Data Loggers, Medical Patient Monitoring and Diagnostic Equipment
What is the MAX115CAX?
The MAX115CAX is a 12-bit, 2us successive-approximation data-acquisition system (DAS) with four simultaneous-sampling track/hold amplifiers and dual 4-input multiplexers, housed in a 36-pin SSOP package. According to the Maxim datasheet, it integrates a +2.5V reference, a buffered reference output, and a parallel digital interface compatible with 16-bit and 32-bit DSPs and microprocessors.
What is the throughput of MAX115CAX when sampling all four channels?
When all four simultaneous-sampling channels are active, the MAX115CAX delivers 116 ksps aggregate throughput (29 ksps per channel with phase-coherent acquisition). Per the Maxim datasheet, throughput scales as: 1 channel = 390 ksps, 2 channels = 218 ksps, 3 channels = 152 ksps, 4 channels = 116 ksps, because each conversion takes 2us plus switching overhead.
Where to buy MAX115CAX online?
As of 2026-10-14, MAX115CAX is listed at DigiKey (part 466266-1-ND) and at Mouser, with stock flagged NRND (Not Recommended for New Designs). Authorized distributors like LCSC, Jotrin, and Avaq carry the MAX115CAX+ (RoHS-compliant) variant. Lead time is generally 4-8 weeks for production orders given the NRND lifecycle status.
What is the price of MAX115CAX?
As of 2026-10-14, the MAX115CAX list price on DigiKey is approximately $28.50 at qty 1, dropping to $18.50 at qty 1000. The MAX115CAX+ (lead-free RoHS) variant on Mouser is comparable. Volume pricing should always be confirmed directly, since NRND parts often show wide distributor-to-distributor variance.
What is the lead time for MAX115CAX?
Lead time for MAX115CAX is typically 4-8 weeks from authorized stock as of 2026-10-14. Because the part is flagged NRND (Not Recommended for New Designs) with an estimated EOL around 2026, engineers should qualify a second-source drop-in such as MAX115EAX or MAX115CAX+T and place a lifetime buy if the design must remain in production beyond 2026.
MAX115CAX vs MAX115EAX - which is better for industrial applications?
The MAX115EAX is the extended-temperature (-40C to +85C) variant of the same die, whereas the MAX115CAX is the commercial-temperature grade (0C to +70C). Both share the same 36-SSOP footprint and identical electrical specifications. For industrial applications operating outside a temperature-controlled enclosure, the MAX115EAX is the correct choice.
When should I choose MAX115CAX over MAX115CAX+T?
Choose MAX115CAX+T (lead-free, tape and reel, RoHS-compliant) for any new design or any product shipped into the EU, California, or other RoHS-regulated markets. The original MAX115CAX (lead-bearing) is appropriate for replacement of legacy boards or for non-RoHS export markets. Both share the same 36-SSOP footprint and are electrically identical.
What is the best drop-in replacement for MAX115CAX?
The best drop-in replacement is MAX115EAX (extended-temperature grade, same 36-SSOP package, same Maxim datasheet family) for industrial applications, or MAX115CAX+T (lead-free RoHS) for new designs. According to the Maxim datasheet, all MAX115/MAX116 variants share the same pinout, so they are interchangeable at the PCB level.
Can MAX115EAX replace MAX115CAX?
Yes, the MAX115EAX is a pin-for-pin drop-in replacement for MAX115CAX with identical electrical specifications and the same 36-SSOP package footprint. The only difference is operating temperature range: MAX115EAX is -40C to +85C (extended), MAX115CAX is 0C to +70C (commercial). The MAX115EAX is fully backward-compatible.
Where to download MAX115CAX datasheet PDF?
The MAX115CAX datasheet PDF is available from the official Analog Devices product page at https://www.analog.com/en/products/MAX115.html. Mirror copies are available at https://www.alldatasheet.com/datasheet-pdf/pdf/89108/MAXIM/MAX115CAX.html and digchip.com datasheet index 280. The document includes pinout, electrical characteristics, and timing diagrams.
Where to find MAX115CAX pinout?
The MAX115CAX pinout is documented on page 1 of the Maxim datasheet at https://www.analog.com/en/products/MAX115.html and on the DigiKey product page (https://www.digikey.com/en/products/detail/analog-devices-inc/MAX115CAX/466266). The 36-SSOP package uses standard SSOP pin numbering with pin 1 indicated by the molded dot on the top of the package.
Is MAX115CAX suitable for three-phase power metering?
Yes, the MAX115CAX is well-suited for three-phase power metering because its four simultaneous-sampling track/hold amplifiers capture phase voltage and current at the exact same instant, eliminating the time-skew error that would otherwise corrupt real-power (P) and reactive-power (Q) calculations. The 12-bit resolution is sufficient for class 0.5 energy meters and most power-quality analyzers.
What is the internal reference voltage of MAX115CAX?
The MAX115CAX integrates a +2.5V internal reference with a buffered output pin that can drive external circuitry. According to the Maxim datasheet, the reference is ratiometric, meaning the ADC transfer function scales directly with VREF, so a stable reference is essential for accurate measurements. The buffered output can typically source a few mA.
What is the difference between MAX115 and MAX116?
The MAX115 and MAX116 are pin-compatible variants in the same datasheet family, differing primarily in analog input range and software-programmable gain configurations. Both share the same 36-SSOP footprint, same 12-bit 2us SAR core, and same four-channel simultaneous-sampling architecture. For most power-monitoring and motor-control applications they are interchangeable.
Is MAX115CAX still in production?
No, the MAX115CAX is flagged NRND (Not Recommended for New Designs) by Maxim/Analog Devices as of 2026-10-14, with an estimated EOL around 2026 per GlobalSpec distributor data. New designs should target the MAX115CAX+T (lead-free RoHS variant) or migrate to the MAX11270, MAX11131, or other modern 12-/14-/16-bit simultaneous-sampling ADCs from the same vendor.

Données de référence d'ingénierie pour MAX115CAX — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose MAX115CAX (original commercial grade, lead-bearing) only for repair of legacy boards or non-RoHS export markets where lead-bearing parts are still accepted. Choose MAX115CAX+T (RoHS lead-free, tape & reel) for any new design or any product shipped into the EU, California, Japan, China, or Korea - it is functionally identical and is the recommended ordering code from the manufacturer. Choose MAX115EAX (extended temperature -40C to +85C) for industrial, automotive, or outdoor applications where the commercial 0C to +70C range is insufficient. All three share the same 36-SSOP footprint, same datasheet, and same electrical specifications, so PCB layout is reusable across variants. New designs targeting long-term supply should additionally qualify a modern alternative such as MAX11270 or MAX11131 given the 2026 estimated EOL.

Comparaison avec les alternatives

Paramètre Ce produit MAX115CAX+T MAX115EAX MAX115CAX-T MAX115CEAX MAX115CAX+
Brand Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices
Package 36-SSOP 36-SSOP - same 36-SSOP - same 36-SSOP - same 36-SSOP - same 36-SSOP - same
Resolution 12 bits 12 bits 12 bits 12 bits 12 bits 12 bits
Throughput (4 ch) 116 ksps 116 ksps 116 ksps 116 ksps 116 ksps 116 ksps
Conversion Time 2 us 2 us 2 us 2 us 2 us 2 us
Lifecycle Status NRND NRND NRND NRND NRND NRND

Principaux différenciateurs

  • Simultaneous-sampling T/H topology for phase-coherent acquisition (vs MAX115CAX+T)
  • Extended-temperature grade option for industrial deployments (vs MAX115EAX)
  • RoHS lead-free ordering code for regulated-market compliance (vs MAX115CAX+)

Notes de conception

Decouple AVDD and DVDD with separate 10uF tantalum + 0.1uF ceramic capacitor pairs placed within 5mm of the respective supply pins; share analog ground and digital ground at a single star-point near the IC to avoid ground-loop noise coupling. The MAX115CAX's internal +2.5V reference requires a stable AVDD for accurate conversions - do not source AVDD from a digital switching regulator without a ferrite bead and additional LC filtering.

Route analog input traces differentially with 50/100 ohm controlled impedance and place the IC on the same side of the board as the input MUXes/CT secondaries. Avoid routing digital data bus lines (D0-D11) parallel to analog input traces; cross them at 90 degrees if needed. The simultaneous-sampling T/H topology is sensitive to inter-channel aperture-delay mismatch, so identical trace lengths on all four CHx+/CHx- pairs are essential to preserve phase coherence at high frequencies.

Estimated: at 2us per-channel conversion and 116 ksps 4-channel throughput, the host CPU must service the parallel data bus within ~8.6us to avoid data-loss - many 8-bit microcontrollers cannot sustain this and require DMA or a hardware FIFO. Also note that the MAX115CAX is NRND with estimated EOL around 2026 per GlobalSpec distributor data; new designs should target MAX115CAX+T (RoHS) or migrate to MAX11270 / MAX11131 for long-term supply.

Informations de conformité

RoHS
Non Compliant
REACH
Unknown
AEC-Q100
Not Applicable
Sans plomb
No
Sans halogène
Unknown
Minerais de conflit
Unknown

Original MAX115CAX is lead-bearing and not RoHS compliant; choose MAX115CAX+T or MAX115CAX+ for RoHS-compliant lead-free designs. All MAX115 variants are not AEC-Q100 qualified. Halogen-free and REACH status not explicitly documented in the verified web data.

Données vérifiées le : 2026-10-14 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

MAX115CAX MAX115CAX datasheet MAX115CAX pinout Analog Devices MAX115CAX MAX115CAX 12-bit simultaneous sampling ADC MAX115CAX 36-SSOP MAX115CAX three-phase power metering MAX115CAX vs MAX115EAX MAX115CAX drop-in replacement buy MAX115CAX online MAX115CAX price lead time MAX115CAX motor control vibration analysis MAX115CAX NRND EOL replacement

Composants & termes associés

Analog Devices Maxim Integrated MAX115CAX MAX115CAX+T MAX115CAX+ MAX115EAX MAX115CAX-T MAX115CEAX MAX116 Data Acquisition System DAS SAR ADC successive approximation track and hold T/H amplifier simultaneous sampling parallel interface +2.5V reference SSOP-36 36-SSOP AEC-Q100 RoHS REACH three-phase power metering vector control motor control vibration analysis modal testing battery management data logger FFT analyzer
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ