The Maxim Integrated MAX1480BEPI+ is a complete electrically isolated RS-485/RS-422 transceiver with one driver and one receiver, a 250 kb/s data rate, and a 28-pin PDIP package. It is designed for half-duplex industrial data links where galvanic isolation and controlled-edge driver performance are required. The MAX1480B reduced-slew-rate driver is intended to minimize EMI and reduce reflections on longer or noisier bus interconnects.

An isolated RS-485/RS-422 transceiver is an interface IC that combines differential bus-driver and receiver functions with an isolation barrier between the logic side and cable side. This class of transceiver belongs to the broader hierarchy of RS-485 transceivers, wired interface ICs, communication interfaces, and semiconductors. The MAX1480 family provides a practical way to connect a digital controller to a long, potentially noisy industrial bus without allowing ground currents or fault energy to cross the isolation boundary.

Verified product information identifies the MAX1480BEPI+ as a 1/1 half-duplex RS-422/RS-485 transceiver in a 28-pin PDIP package. The manufacturer describes the isolated outputs as meeting RS-485 and RS-422 specifications. Search results also identify the MAX1480B reduced-slew-rate driver, a 250 kb/s data rate, and a 70 mV receiver hysteresis. The hybrid-microcircuit implementation provides integrated isolation rather than requiring separate optocouplers and isolated transceiver packages on the PCB.

Typical uses include automated test equipment, HVAC and building-control networks, industrial-control links, local-area networks, and isolated RS-485/RS-422 data interfaces. The 250 kb/s rate makes the device suitable for low- and moderate-speed supervisory or control communications rather than high-rate storage networking. Half-duplex operation means that transmit and receive directions share the same differential pair, so the bus driver must be disabled while receiving.

The principal design consideration is bus implementation. Differential pair routing should use a controlled-impedance, symmetrical layout where practical, with grounding and shielding selected according to the cable environment and installation requirements. Isolation is valuable, but it does not replace correct termination, common-mode protection, or surge suppression. The MAX1480BEPI+ should be selected only when its exact electrical ratings, isolation behavior, and pinout are verified against the manufacturer datasheet for the final design.

This product page combines the verified manufacturer description, distributor listings, package identity, application context, and available comparison data for MAX1480 family variants. It also distinguishes exact family options from options whose electrical differences require engineering review before substitution.

Alternatives de remplacement direct pour MAX1480BEPI+ — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Variantes de cette série

Modèles de la même série directement compatibles avec MAX1480BEPI+ (même facteur de forme et même empreinte) — différant par Data Rate, Operating Temperature, Package.

Analog Devices
Data Rate: 250 kbps
Operating Temperature: -40C to +85C
Package: 28-PDIP (0.600", 15.24 mm wide)
Comparer avec MAX1480BEPI+ →

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

MAX1480BCPI+

✅ Remplacement direct
Analog Devices
📦 28-DIP (0.600", 15.24 mm)
RS-422, RS-485 · 1/1 · Half · 250 kbps · 70 mV · 5 V (single supply) · 28-PDIP (0.600", 15.24 mm wide) · 1000 Vrms (galvanic, transformer-based)

✓ En stock

$24.1 / unité

Voir la fiche technique →

MAX1480CEPI+

✅ Remplacement direct
📦 28-DIP (0.600", 15.24 mm)
Same 28-pin electrically isolated RS-485/RS-422 interface package; exact driver, receiver, and supply differences are not quantified in the supplied web data and require datasheet verification.

📋 Alternative de référence (hors catalogue)

MAX1480CCPI+

✅ Remplacement direct
📦 28-DIP (0.600", 15.24 mm)
Same MAX1480 family and 28-pin electrically isolated RS-485/RS-422 package; exact C-variant electrical differences are not provided in the verified data.

📋 Alternative de référence (hors catalogue)

MAX1480AEPI+

✅ Remplacement direct
📦 28-DIP (0.600", 15.24 mm)
Same MAX1480 family and 28-pin DIP package, but the A/B/C variant differences are not quantified in the supplied data and must be checked against the datasheet.

📋 Alternative de référence (hors catalogue)

MAX1480BEPI

✅ Remplacement direct
📦 28-DIP (0.600", 15.24 mm)
Same MAX1480BEPI base ordering designation and 28-PDIP package; the plus-sign commercial/ordering distinction is not electrically quantified in the supplied data.

📋 Alternative de référence (hors catalogue)

MAX1480BEPI+ Spécifications

Product Type Complete electrically isolated RS-485/RS-422 data interface
Transceiver Configuration 1 driver / 1 receiver
Duplex Mode Half-duplex
Supported Protocols RS-422 and RS-485
Débit de données 250 kb/s
Isolation Electrically isolated
Driver Slew Rate Reduced-slew-rate driver
Receiver Hysteresis 70 mV
Supply Architecture Single +5 V supply on logic side powers both sides
Boîtier 28-pin PDIP
Boîtier / Format 28-DIP (0.600 inch, 15.24 mm)
Type de montage Through-hole
Température de fonctionnement 0 °C to +70 °C
Application Category Automated test equipment
Application Category HVAC and building-control networks
Application Category Industrial-control local-area networks
Application Category EMI-sensitive isolated data interfaces

Guide de configuration des broches du MAX1480BEPI+ 28-dip (0.600 inch, 15.24 mm)

Configuration des broches du MAX1480BEPI+ (boîtier 28-dip (0.600 inch, 15.24 mm)). La numérotation des broches, les fonctions et les schémas de connexion sont définis dans la fiche technique du fabricant. Consultez-la pour l'empreinte exacte et les directives de soudage.

Schéma de brochage du boîtier 28-dip (0.600 inch, 15.24 mm) pour le MAX1480BEPI+

Aucune donnée de brochage détaillée disponible pour MAX1480BEPI+.

Consultez la fiche technique pour la configuration complète des broches.

Applications typiques

MAX1480BEPI+ convient pour 7 applications: Automated Test Equipment, HVAC and Building-Control Networks, Industrial-Control Local Area Networks, HVAC and Building-Control Remote Sensors, EMI-Sensitive Isolated Data Links, Local Area Network Gateways, Isolated RS-485/RS-422 Test and Measurement.

🏭

Automated Test Equipment

MAX1480BEPI+ fits isolated RS-485 or RS-422 links between test-system controllers and remote fixtures where ground-potential differences and cable noise are concerns. Its electrically isolated 1-driver/1-receiver interface supports half-duplex communication at up to 250 kb/s, while the MAX1480B reduced-slew-rate driver is intended to minimize EMI and reflections. Keep the cable-side network compact near the connector and verify the complete PDIP pinout, isolation limits, and bus termination in the manufacturer datasheet.

🏠

HVAC and Building-Control Networks

MAX1480BEPI+ is suitable for isolated building-control networks carrying supervisory data between controllers, sensors, actuators, and supervisory systems. The 250 kb/s rate is appropriate for many HVAC and facility-control message rates, while electrical isolation helps prevent ground-current problems between separately powered equipment. The half-duplex RS-485 arrangement requires bus-direction control, symmetrical differential routing, and protection appropriate to the building cable environment.

🏭

Industrial-Control Local Area Networks

Use MAX1480BEPI+ when an industrial controller must communicate over an isolated RS-485 or RS-422 segment and the bus can operate at 250 kb/s or less. Its integrated 1/1 transceiver reduces the number of separate bus-driver and receiver blocks, and the reduced-slew-rate MAX1480B driver helps control edge-rate-related EMI. Design the network around the actual cable length, node count, grounding method, termination, and fault-recovery requirements rather than treating isolation as a substitute for surge protection.

🌐

HVAC and Building-Control Remote Sensors

MAX1480BEPI+ can connect a controller to remote temperature, pressure, airflow, or equipment-status nodes through an isolated differential bus. The 250 kb/s maximum data rate is more than adequate for typical supervisory sensor traffic, while the receiver's identified 70 mV hysteresis helps reject small noise excursions around logic thresholds. Because the sensor network may span long cables and multiple buildings, verify common-mode limits, isolation voltage, and cable-side grounding against the installation specification.

📡

EMI-Sensitive Isolated Data Links

MAX1480BEPI+ is appropriate when an RS-485 or RS-422 connection must cross an isolation boundary in an electrically noisy installation. The MAX1480B reduced-slew-rate driver is specifically described as minimizing EMI and reducing reflections, which can improve system behavior when combined with careful board and cable design. Keep the isolated bus section away from switching power nodes and high-current return paths, and use the manufacturer's recommended isolation and termination arrangement.

🖥️

Local Area Network Gateways

MAX1480BEPI+ can serve as the isolated field-side interface in a gateway that translates between a local controller and a longer RS-485 or RS-422 backbone. Its half-duplex operation is suitable for request/response fieldbus traffic at up to 250 kb/s, and the integrated receiver/driver simplifies the physical-layer implementation. The gateway must manage transmit-enable timing, avoid simultaneous drive conflicts, and validate each node's isolation and grounding arrangement.

🧰

Isolated RS-485/RS-422 Test and Measurement

MAX1480BEPI+ is useful in test and measurement equipment that needs a robust differential interface to an external instrument or remote fixture. Electrical isolation helps separate the instrument's logic ground from the external bus, while the 250 kb/s data rate supports common control and status traffic. The reduced-slew-rate driver should be paired with a controlled differential layout, verified terminations, and appropriately rated external protection for the laboratory or industrial environment.

Récapitulatif des produits recommandés

MAX1480BEPI+ Maxim Integrated Utilisé dans : Automated Test Equipment, HVAC and Building-Control Networks, Industrial-Control Local Area Networks, HVAC and Building-Control Remote Sensors, EMI-Sensitive Isolated Data Links, Local Area Network Gateways, Isolated RS-485/RS-422 Test and Measurement MAX1480BCPI+ Analog Devices Utilisé dans : Automated Test Equipment, HVAC and Building-Control Remote Sensors, Isolated RS-485/RS-422 Test and Measurement MAX1480CEPI+ Same-family MAX1480 comparison option Utilisé dans : HVAC and Building-Control Networks, EMI-Sensitive Isolated Data Links MAX1480CCPI+ Same-family MAX1480 comparison option Utilisé dans : Industrial-Control Local Area Networks MAX1480BEPI Base ordering comparison option Utilisé dans : Local Area Network Gateways
What is MAX1480BEPI+?
MAX1480BEPI+ is a complete electrically isolated RS-485/RS-422 transceiver from Maxim Integrated with one driver, one receiver, and a half-duplex configuration. The manufacturer product page identifies the MAX1480A, MAX1480B, and MAX1480C variants in 28-pin DIP packages, while distributor listings identify MAX1480BEPI+ as a 28-PDIP 1/1 transceiver. It is used where a controller must connect to an industrial differential bus across an isolation barrier.
What is the operating data rate of MAX1480BEPI+?
MAX1480BEPI+ supports a maximum data rate of 250 kb/s according to the distributor comparison information and the MAX1480B family description. This rate suits moderate-speed industrial-control, building-control, and isolated communications links rather than high-speed storage or Ethernet applications. The reduced-slew-rate driver is also identified as helping minimize EMI and reflections in suitable bus implementations.
Where can I download the MAX1480BEPI+ datasheet?
The official MAX1480B product page is available at Analog Devices: https://www.analog.com/en/products/max1480b.html. That page provides the manufacturer product information and links to the relevant technical documentation. Search results also identify the MAX1480BEPI datasheet as a document for the isolated RS-485/RS-422 interface. Verify the exact package, temperature grade, and ordering suffix against the manufacturer documentation before releasing a production design.
Where can I buy MAX1480BEPI+ online?
MAX1480BEPI+ can be purchased through authorized distributors such as DigiKey, Mouser, and other suppliers listed in the verified search results. The verified DigiKey listing identifies the part as a 28-PDIP, 1/1 half-duplex RS-422/RS-485 transceiver, and the Mouser listing provides a separate commercial source. Current price and stock should be checked directly because distributor inventory and pricing change. The listed LCSC result showed 22 units in stock and a starting price of $25.5783 as of 2026-10-21.
What is the price of MAX1480BEPI+?
The verified LCSC result lists MAX1480BEPI+ from $25.5783, while the Analog Devices product page lists MAX1480B starting from $25.39. These are commercial listings rather than a universal quotation, and prices can vary by distributor, quantity, and availability. The available price reference is current as of 2026-10-21. Use the distributor checkout or an RFQ for the final delivered price.
Is MAX1480BEPI+ in stock?
Stock status is not consistent across the verified listings, so current availability should be confirmed with the distributor before purchase. The LCSC result reported 22 units in stock, while DigiKey and Mouser product pages indicate purchasing availability but do not establish a fixed quantity in the supplied data. Treat the part as BackOrder for structured commerce metadata unless the seller confirms current inventory. XAIPART lead time and stock require a direct quotation.
What is the MAX1480BEPI+ pinout?
MAX1480BEPI+ is identified as a 28-pin PDIP device. The supplied search results do not include a complete pin-number-to-function table, so an exact pinout cannot be reproduced safely without the manufacturer datasheet. Use the official MAX1480B page and the device datasheet for the complete PDIP pin assignment, including logic-side supply, isolated-side supply, driver, receiver, enable, and ground connections. Do not infer pin functions from the package drawing alone.
Is MAX1480BEPI+ suitable for industrial-control networks?
Yes, MAX1480BEPI+ is explicitly listed for industrial-control networks, HVAC or building-control networks, automated test equipment, and isolated RS-485/RS-422 data interfaces. Its electrically isolated architecture is useful when the bus ground may differ from the controller ground or when the application needs a defined isolation barrier. The 250 kb/s rating should be matched to the actual cable length, topology, termination, noise environment, and system timing.
How does MAX1480BEPI+ compare with MAX1480CEPI+?
MAX1480CEPI+ is another 28-pin DIP electrically isolated RS-485/RS-422 interface in the same MAX1480 family, but the supplied comparison search does not establish that it is an exact drop-in replacement. The MAX1480B is identified with reduced-slew-rate drivers and a 250 kb/s half-duplex configuration. Before substituting MAX1480CEPI+, compare supply voltage, isolation rating, driver timing, receiver thresholds, temperature grade, and every PDIP pin function in the manufacturer datasheets.
What is the difference between MAX1480BEPI+ and MAX1480BCPI+?
The verified comparison data identifies MAX1480BCPI+ as the same MAX1480B family, half-duplex RS-422/RS-485 transceiver in a 28-pin PDIP package with a 250 kb/s data rate and 70 mV receiver hysteresis. The provided evidence does not confirm the exact suffix-level electrical differences, so they should not be treated as automatically interchangeable. Confirm the manufacturer pinout, ordering information, isolation rating, and lifecycle status before using one as a replacement for the other.
Can MAX1480BEPI+ replace MAX1480CEPI+?
A direct drop-in replacement cannot be confirmed from the supplied data alone. Both parts are described as complete electrically isolated RS-485/RS-422 interfaces in 28-pin DIP packages, which makes them useful comparison candidates. However, package identity is not enough to establish pin-to-pin compatibility; verify driver enable polarity, supply pins, isolation ratings, receiver thresholds, data rate, temperature range, and package tolerances. Treat the relationship as a review-required substitution until the datasheets confirm every relevant parameter.
What can replace MAX1480BEPI+?
The strongest same-family candidates identified by the verified search are MAX1480BCPI+, MAX1480CEPI+, and MAX1480CCPI+, but the data does not prove exact drop-in compatibility for every suffix. Engineers should compare the complete 28-pinAssignments against the official MAX1480 datasheets and verify isolation, supply, timing, logic levels, and temperature specifications. No qualified cross-brand 28-pin GALVANIC-isolated substitute was identified in the supplied evidence, so a redesign may be necessary.
Is MAX1480BEPI+ a drop-in replacement for MAX147BEPP+?
MAX147BEPP+ should not be assumed to be a drop-in replacement for MAX1480BEPI+. The verified cross-reference search includes a comparison page, but it does not provide evidence that MAX147BEPP+ has the same 28-pin pinout, isolation architecture, supply arrangement, or RS-485/RS-422 electrical ratings. Treat it as a functional comparison candidate only until the manufacturer datasheets confirm pin compatibility and all operating limits.
Does MAX1480BEPI+ reduce EMI?
The MAX1480B driver is identified as a reduced-slew-rate driver, which is intended to minimize EMI and reduce reflections. This feature can be valuable in industrial and building-control systems where cable routing and neighboring equipment make uncontrolled fast edges problematic. The actual EMI result still depends on PCB layout, cable type, termination, common-mode behavior, grounding, and shielding; the device feature does not guarantee compliance by itself.
What are the key specifications of MAX1480BEPI+ that engineers should know?
The key verified specifications are one driver and one receiver, half-duplex operation, RS-422 and RS-485 support, electrical isolation, a 250 kb/s data rate, a reduced-slew-rate driver, 70 mV receiver hysteresis, a single +5 V logic-side supply architecture, and a 28-pin PDIP package. The manufacturer also identifies automated test equipment, HVAC and building-control networks, industrial-control networks, and EMI-sensitive isolated interfaces as application areas. Exact supply current, isolation voltage, common-mode limits, and pin functions require the datasheet.
Is MAX1480BEPI+ RoHS compliant?
The supplied verified data does not state the RoHS status of MAX1480BEPI+, so the compliance value remains unknown rather than being assumed. The ETEI comparison result lists RoHS as a comparison field, but the supplied snippet does not provide the target part's actual declaration. Before procurement, request the current manufacturer RoHS declaration or material compliance statement and confirm the exact ordering suffix.
What electrical protection should be used with MAX1480BEPI+?
MAX1480BEPI+ is an isolated RS-485/RS-422 interface, but the supplied data does not specify its transient, surge, or ESD ratings. External protection should therefore be selected from the actual cable length, installation environment, grounding arrangement, and applicable system requirements. Do not assume that galvanic isolation alone provides surge protection. Confirm the transceiver's absolute maximum ratings and bus-node fault tolerance in the manufacturer datasheet before selecting TVS devices, fuses, resistors, or other network components.
How should MAX1480BEPI+ be laid out for an RS-485 bus?
Place the transceiver close to the cable connector and route the differential pair as a symmetrical pair, minimizing stubs and avoiding sharp turns where practical. The verified family information specifically highlights reduced-slew-rate drivers for EMI control, so layout should preserve that benefit by keeping the protected network compact and away from switching nodes. Use the datasheet's recommended termination and isolation-ground connections; do not connect the isolated cable-side ground to the logic ground merely for convenience.
Is MAX1480BEPI+ still active?
The verified distributor and Xecor results identify MAX1480BEPI+ as active, and the manufacturer maintains a current MAX1480B product page. Lifecycle status can still change for an individual ordering suffix, so procurement should confirm stock, lifecycle status, and lead time with the manufacturer or an authorized distributor. The page was last verified on 2026-10-21 using the supplied web results.
What is the best same-family MAX1480 alternative for MAX1480BEPI+?
MAX1480BCPI+ is the closest identified same-family candidate because the verified comparison describes it as a MAX1480B, 28-pin PDIP, half-duplex RS-422/RS-485 transceiver with 250 kb/s operation and 70 mV receiver hysteresis. It is not certified as a drop-in replacement by the supplied data, so check the exact pinout, suffix, isolation rating, and supply requirements before substitution. MAX1480CEPI+ and MAX1480CCPI+ are also family comparison candidates but require the same verification.

Données de référence d'ingénierie pour MAX1480BEPI+ — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose MAX1480BEPI+ when the design needs a complete electrically isolated RS-485/RS-422 interface with one driver and one receiver, half-duplex operation, a 250 kb/s data rate, and a 28-pin PDIP footprint. Its MAX1480B reduced-slew-rate driver is particularly relevant when cable EMI and edge reflections require attention. MAX1480BCPI+ is the closest stated same-family comparison candidate and shares the identified data rate, duplex mode, package, and receiver hysteresis, but suffix-level differences still require datasheet review. MAX1480CEPI+ and MAX1480CCPI+ are useful family alternatives in the same 28-pin DIP class, but the supplied data does not quantify their exact differences. MAX1480AEPI+ should be selected only after confirming electrical and pin compatibility. No cross-brand drop-in replacement is verified by the supplied search results, so a new footprint or redesign may be required.

Comparaison avec les alternatives

Paramètre Ce produit MAX1480BCPI+ MAX1480CEPI+ MAX1480CCPI+ MAX1480AEPI+ MAX1480BEPI
Brand Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated Maxim Integrated
Package 28-pin PDIP 28-pin PDIP 28-pin PDIP 28-pin PDIP 28-pin PDIP 28-pin PDIP
Supported Protocols RS-422 and RS-485 RS-422 and RS-485 RS-422 and RS-485 RS-422 and RS-485 RS-422 and RS-485 RS-422 and RS-485

Principaux différenciateurs

  • Integrated isolated 1/1 half-duplex interface (vs MAX1480BCPI+)
  • Reduced-slew-rate driver positioning (vs MAX1480CEPI+)
  • Verified 250 kb/s operating rate (vs MAX1480CCPI+)
  • 28-pin PDIP package reuse (vs MAX1480AEPI+)
  • Active product-page support (vs MAX1480BEPI)

Notes de conception

Route the RS-485/RS-422 differential pair as a short, symmetrical pair from the transceiver to the connector, avoiding split returns, long stubs, and proximity to switching nodes. The MAX1480B reduced-slew-rate driver helps with EMI control, but layout still determines whether that benefit reaches the installed system. Keep the cable-side ground and isolation components in the protected network area, and use the manufacturer's recommended pin connections and termination arrangement.

Do not treat electrical isolation as a complete surge-protection solution. The verified data establishes an isolated RS-485/RS-422 interface and a 250 kb/s rate, but it does not establish the target part's complete surge, ESD, fault-current, or absolute-maximum ratings. Confirm those limits in the manufacturer datasheet, then select TVS, fusing, termination, and common-mode-choke components for the actual cable length and installation environment.

The verified family information states that a single +5 V supply on the logic side powers both sides of the interface, but the target's exact supply current, isolated-side supply arrangement, decoupling requirements, and undervoltage behavior are not supplied. Follow the manufacturer datasheet for capacitor values, supply sequencing, and isolation-side power requirements. Validate the logic-side voltage at the transceiver pins during startup and ensure the controller's transmit-enable timing cannot leave the bus driver active during receive operation.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

The supplied verified results do not provide a definitive compliance declaration for MAX1480BEPI+. AEC-Q100 is treated as not_applicable because no automotive qualification claim appears in the supplied data; this is not an automotive qualification statement.

Recherches associées

MAX1480BEPI+ MAX1480BEPI datasheet Maxim Integrated MAX1480BEPI+ MAX1480BEPI+ 250 kb/s isolated transceiver MAX1480BEPI+ 28-pin PDIP isolated RS-485 transceiver for industrial control MAX1480BEPI+ vs MAX1480BCPI+ MAX1480BEPI+ drop-in replacement buy MAX1480BEPI+ online MAX1480BEPI+ price and stock MAX1480BEPI+ RS-485 pinout reduced slew rate RS-485 transceiver

Composants & termes associés

Maxim Integrated MAX1480BEPI+ MAX1480B MAX1480BCPI+ MAX1480CEPI+ MAX1480CCPI+ MAX1480AEPI+ MAX1480BEPI isolated RS-485 transceiver RS-422 transceiver data interface IC wired communication interface half-duplex transceiver differential bus galvanic isolation automated test equipment HVAC control building-control network industrial-control network local area network reduced-slew-rate driver 250 kb/s 70 mV receiver hysteresis 28-pin PDIP EMI
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ