MAX3232ECUP+G071 - 1 Mbps RS-232 Transceiver | Analog Devices
Référence : MAX3232ECUP+G071 ✓ ActifMAX3232ECUP+G071 Présentation
An RS-232 transceiver is an interface IC that converts logic-level digital signals into RS-232 differential voltage levels and converts incoming RS-232 signals back into logic-compatible levels. The MAX3232E family belongs to the interface IC hierarchy, combining line drivers, line receivers, and an on-chip voltage converter. This makes it useful in industrial controls, test equipment, point-of-sale terminals, embedded systems, and computer peripherals where the host uses a conventional serial interface.
The MAX3232ECUP+G071 supports operation from 3.0 V to 5.5 V, with communication rates up to 1 Mbps. Its ±15 kV ESD protection helps improve reliability when cables are connected to exposed connectors. The 20-pin TSSOP package supports compact, surface-mount PCB layouts, while the MAX3232E family is designed to be pin-, package-, and functionally compatible with the industry-standard MAX232, according to Analog Devices.
The integrated charge-pump circuitry provides the bipolar voltage levels required by RS-232 without requiring an external power supply. External capacitors are used with the on-chip charge pump, while the driver and receiver sections support two transmit channels and two receive channels. This combination is useful when a system needs bidirectional serial communication but does not require a full multi-channel RS-232 port.
Typical uses include industrial serial controllers, laboratory instruments, barcode and scanner interfaces, POS equipment, access-control systems, and embedded diagnostic equipment. In these applications, the device can bridge a low-voltage microcontroller UART to an RS-232 connector while providing ESD protection at the physical interface.
Designers should follow the manufacturer datasheet for the exact charge-pump capacitor values, bypass-capacitor recommendations, RS-232 connector protection, and pin assignments. PCB layout should keep the charge-pump and bypass capacitors close to their associated pins, and the signal path should be routed away from noisy switching nodes. The TSSOP-20 footprint should also be checked against the PCB library before placement because package suffix codes identify the exact ordering configuration.
Alternatives de remplacement direct pour MAX3232ECUP+G071 — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec MAX3232ECUP+G071 (même facteur de forme et même empreinte) — différant par ESD Protection, Maximum Data Rate, Product Type, Supply Voltage Range.
MAX3232ECUP
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
MAX3232EEUE+
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
MAX3232ECUP+T
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
MAX3232EEUP+
✅ Remplacement direct ⚠️ Spécifications non vérifiéesContactez-nous pour le prix
Voir la fiche technique →MAX3317CUP+
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
MAX3000EEUP+
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
MAX3232ECUP+G071 Spécifications
| Product Type | 2/2 RS-232 transceiver |
| Driver and Receiver Count | 2 drivers and 2 receivers |
| Supply Voltage Range | 3.0 V to 5.5 V |
| Maximum Data Rate | 1 Mbps |
| ESD Protection | ±15 kV |
| Low-Power Supply Current | Down to 10 nA |
| Interface Standard | True RS-232 |
| Boîtier | 20-pin TSSOP |
| Type de montage | Surface mount |
| Peak Reflow Temperature | 260 °C |
| Peak Reflow Time | 30 s |
| Terminal Finish | Matte tin |
| Moisture Sensitivity Level | MSL 1 |
Guide de configuration des broches du MAX3232ECUP+G071 20-pin tssop
Configuration des broches du MAX3232ECUP+G071 (boîtier 20-pin tssop). La numérotation des broches, les fonctions et les schémas de connexion sont définis dans la fiche technique du fabricant. Consultez-la pour l'empreinte exacte et les directives de soudage.
Aucune donnée de brochage détaillée disponible pour MAX3232ECUP+G071.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
MAX3232ECUP+G071 convient pour 6 applications: Industrial serial controller interface, Test and measurement equipment, Point-of-sale and peripheral interface, Embedded diagnostic communications, Instrumentation service port, Data acquisition front end.
Industrial serial controller interface
The MAX3232ECUP+G071 fits industrial controllers that expose an RS-232 port to sensors, service equipment, or legacy machinery. Its 3.0 V to 5.5 V operating range allows it to connect to 3.3 V embedded processors or 5 V control hardware, while the 1 Mbps maximum data rate provides substantial margin for command and telemetry traffic. The two-driver, two-receiver arrangement supports bidirectional communication with one transmit and one receive path active in each direction. The ±15 kV ESD protection rating is valuable at an external connector, although the final design should also include suitable grounding, cable routing, and connector-level surge protection.
Recommandé
Test and measurement equipment
The MAX3232ECUP+G071 is useful in programmable laboratory instruments that need a compact RS-232 command interface for legacy analyzers, signal generators, or automated test fixtures. A 1 Mbps capability supports fast status polling and short data transfers, while the integrated dual-channel interface reduces the number of external transceivers. In a 3.3 V measurement system, the minimum 3.0 V supply requirement can simplify rail compatibility. Designers should use the manufacturer reference circuit, observe the specified charge-pump capacitors, and keep the RS-232 trace short and away from high-energy analog and switching paths.
Recommandé
Point-of-sale and peripheral interface
Retail peripherals, scanners, and point-of-sale terminals can use the MAX3232ECUP+G071 to bridge a host controller to an RS-232 accessory port. The device's two transmitters and two receivers are sufficient for common command and status connections without occupying a larger multi-channel RS-232 controller. Its 20-pin TSSOP package supports compact board layouts, and its low-voltage operation is compatible with embedded 3.3 V systems. The ESD rating helps protect the interface when accessory cables are repeatedly connected, but reliable operation still depends on correct signal grounding, shielding, and connector design.
Recommandé
Embedded diagnostic communications
The MAX3232ECUP+G071 is appropriate for embedded systems that expose service, logging, or configuration information through an RS-232 port. A low-power 3.3 V controller can use the device's 3.0 V to 5.5 V operating range, while the two-channel arrangement supports separate transmit and receive routes. The 1 Mbps maximum rate is useful for firmware status output and diagnostic traces, although practical command protocols should normally include framing and error checking. Place the transceiver near the connector and maintain a continuous signal-ground path to reduce common-mode voltage stress.
Recommandé
Instrumentation service port
The MAX3232ECUP+G071 can provide a service and configuration port for industrial instrumentation, environmental monitors, and remote measurement equipment. Two transmitters and two receivers provide enough channels for a typical bidirectional service link, while the 1 Mbps capability supports faster downloads than many low-speed RS-232 links. Its ±15 kV ESD protection is particularly relevant to field-service equipment where the serial connector may be accessible during installation or maintenance. The complete instrument should still use a protective enclosure and validated cable and grounding practices.
Recommandé
Data acquisition front end
The MAX3232ECUP+G071 can connect a compact data-acquisition controller to an RS-232 instrument or legacy test fixture. The 3.0 V to 5.5 V supply range supports both modern embedded control logic and older 5 V interface circuits, while the 1 Mbps rate accommodates moderate command traffic and status data. Its 20-pin TSSOP footprint leaves board area for signal conditioning and isolated interface elements. For laboratory equipment, minimize loop area, route the ground reference with the data path, and verify compatibility with the connected instrument's driver, receiver, and connector requirements.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour MAX3232ECUP+G071 — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | MAX3232ECUP | MAX3232EEUE+ | MAX3232ECUP+T | MAX3317CUP+ | MAX3000EEUP+ |
|---|---|---|---|---|---|---|
| Package | 20-TSSOP | 20-TSSOP | 20-TSSOP | 20-TSSOP | 20-TSSOP | 20-TSSOP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Product Type | 2/2 RS-232 transceiver | RS-232 transceiver | RS-232 transceiver | RS-232 transceiver | RS-232 transceiver | Low-power RS-232 transceiver |
| Ordering Code | MAX3232ECUP+G071 | MAX3232ECUP | MAX3232EEUE+ | MAX3232ECUP+T | MAX3317CUP+ | MAX3000EEUP+ |
Principaux différenciateurs
- Lower-voltage compatibility with embedded systems (vs MAX3317CUP+)
- Established MAX3232E family compatibility (vs MAX3232ECUP+T)
- Two-channel full RS-232 transceiver with ESD protection (vs MAX3000EEUP+)
Notes de conception
Place the charge-pump capacitors and supply bypass capacitors directly beside the pins identified in the manufacturer reference circuit. Keep the connections short, use the specified capacitor values, and provide a low-impedance ground return for the driver and receiver sections. A compact placement reduces loop area and helps preserve the intended communication rate while limiting disturbance to adjacent analog circuitry.
Do not treat RS-232 as a differential, low-voltage logic interface. The driver outputs use bipolar voltage levels, and the receiver inputs require compatible signal amplitudes and common-mode conditions. Verify whether the connected equipment uses the MAX3232E pinout, the standard MAX232 pinout, or a different RS-232 implementation. Confirm signal-ground continuity and avoid relying on chassis or earth ground as a substitute for the interface ground.
Route RS-232 traces away from switching regulators, relays, motor drivers, and high-speed clock edges. Keep the transceiver close to its connector when practical, and maintain a continuous ground reference beneath or adjacent to the interface path. Although the device provides ±15 kV ESD protection, connector placement, cable strain relief, enclosure grounding, and system-level surge protection remain important parts of a reliable port.
Informations de conformité
The verified product records identify a matte-tin terminal finish with JESD-609 code e3, but they do not explicitly state the requested compliance statuses.