MCP3911A0-E/ML Présentation

The Microchip MCP3911A0-E/ML is a 24-bit, dual-channel analog front end for energy-metering and precision analog measurement systems. It operates from a 2.7 V to 3.6 V supply, provides two simultaneous-sampling delta-sigma ADCs, and is housed in a 20-QFN package measuring 4 x 4 mm. The device combines two programmable gain amplifiers with a 20 MHz SPI-compatible serial interface.

An analog front end, or AFE, integrates the signal-conditioning and conversion functions needed between a physical sensor and a digital controller. The MCP3911 belongs to the energy-metering AFE hierarchy: dual-channel delta-sigma ADC, programmable gain amplifier, voltage reference, phase compensation, and serial digital interface. This integration reduces external analog circuitry while preserving simultaneous measurement of two related input channels.

Key features include 24-bit conversion resolution, a 1.2 V internal reference with a 9 ppm/°C temperature coefficient, and phase-delay compensation with 1 µs resolution. The two PGAs condition low-level sensor inputs before conversion, while the 20 MHz SPI-compatible interface supports efficient communication with a host microcontroller. The distributor description identifies the MCP3911A0-E/ML as an 8.9 mW, 20-QFN energy-metering AFE.

Internally, the MCP3911 uses two synchronous-sampling delta-sigma ADCs to acquire both channels at the same time. Simultaneous sampling helps cancel common-mode disturbances and avoids time skew when comparing two quantities such as voltage and current. The phase compensation block, modulator outputs, calibration registers, reference selection, and digital gain and offset controls support accurate energy calculations and coordinated system calibration.

Typical uses include single-phase energy meters, industrial power monitors, smart-grid measurement equipment, and embedded metering systems. Its dual-channel architecture is especially useful when one channel senses voltage and the other senses current. The 3.3 V supply requirement also aligns the AFE with 3.3 V microcontroller and digital-control environments where external signal conditioning should be minimized.

Designers should select input and reference components according to the manufacturer’s application circuit, maintain the specified analog and digital layout, and account for the AFE’s supply and common-mode limits. When accuracy depends on current-sensor gain, the programmed PGA setting, reference voltage, calibration coefficients, and system offset must be evaluated together rather than optimized independently.

This page combines the manufacturer’s device capabilities with practical metering considerations, structured alternatives, interface guidance, and a parameter-focused comparison. It is intended to help engineers determine whether the MCP3911A0-E/ML fits a compact, dual-channel, 24-bit energy-metering design before committing to a PCB footprint.

Alternatives de remplacement direct pour MCP3911A0-E/ML — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

MCP3911A0T-E/ML

✅ Remplacement direct
📦 QFN-20 (4 x 4 mm)
Extended temperature grade versus the standard MCP3911A0-E/ML; resolution, channels, voltage, and 20-QFN footprint remain the same

📋 Alternative de référence (hors catalogue)

MCP3911A1-E/ML

✅ Remplacement direct ⚠️ Spécifications non vérifiées
📦 QFN-20 (4 x 4 mm)
Different programmed-gain configuration while retaining two 24-bit channels and the 20-QFN footprint; gain setting may require recalibration

📋 Alternative de référence (hors catalogue)

MCP3911A2-E/ML

✅ Remplacement direct ⚠️ Spécifications non vérifiées
📦 QFN-20 (4 x 4 mm)
Different programmed-gain configuration while retaining two 24-bit channels and the 20-QFN footprint; gain setting may require recalibration

📋 Alternative de référence (hors catalogue)

MCP3911A3-E/ML

✅ Remplacement direct ⚠️ Spécifications non vérifiées
📦 QFN-20 (4 x 4 mm)
Different programmed-gain configuration while retaining two 24-bit channels and the 20-QFN footprint; gain setting may require recalibration

📋 Alternative de référence (hors catalogue)

MCP3911A4-E/ML

✅ Remplacement direct ⚠️ Spécifications non vérifiées
📦 QFN-20 (4 x 4 mm)
Different programmed-gain configuration while retaining two 24-bit channels and the 20-QFN footprint; gain setting may require recalibration

📋 Alternative de référence (hors catalogue)

MCP3911A0-E/ML Valeurs maximales et caractéristiques électriques

Product Type Dual-channel energy-metering analog front end
ADC Resolution 24 bits
Number of Channels 2 channels
Sampling Architecture 2 simultaneous-sampling delta-sigma ADCs
Supply Voltage Range 2.7 V to 3.6 V
Nominal Supply Voltage 3.3 V
Programmable Gain Amplifier Count 2 PGAs
Internal Reference Voltage 1.2 V
Internal Reference Temperature Coefficient 9 ppm/°C
Phase Delay Compensation Resolution 1 µs
Serial Interface SPI compatible
Maximum Serial Interface Clock 20 MHz
Typical Power Consumption 8.9 mW
Boîtier 20-QFN (4 x 4 mm)
Type de montage Surface mount
External Reference Support Supported

Guide de configuration des broches du MCP3911A0-E/ML 20-qfn (4 x 4 mm)

Configuration des broches du MCP3911A0-E/ML (boîtier 20-qfn (4 x 4 mm)). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.

Schéma de brochage du boîtier 20-qfn (4 x 4 mm) pour le MCP3911A0-E/ML

Aucune donnée de brochage détaillée disponible pour MCP3911A0-E/ML.

Consultez la fiche technique pour la configuration complète des broches.

Applications typiques

MCP3911A0-E/ML convient pour 6 applications: Single-Phase Smart Energy Meter, Industrial Power Monitoring, Residential Load Monitoring, Smart Grid Sensor Interface, Energy Metering Test Equipment, Solar and Battery Energy Management.

⚡

Single-Phase Smart Energy Meter

The MCP3911A0-E/ML fits single-phase metering because its two simultaneous-sampling 24-bit delta-sigma ADCs can acquire voltage and current from related sensor paths without time skew. Two PGAs provide the input conditioning normally required by low-level analog signals, while phase-delay compensation supports accurate real-power calculations. The 2.7 V to 3.6 V operating range and 20-QFN footprint also conserve board area in a compact meter. Designers should set channel gain, reference voltage, offset, and gain calibration together so that the full-scale values match the current sensor and voltage divider.

🏭

Industrial Power Monitoring

The MCP3911A0-E/ML can serve as the measurement core of an industrial power monitor when voltage and current must be digitized with consistent timing. Its two 24-bit channels, simultaneous sampling, and phase-delay compensation provide the numerical foundation for apparent-power, real-power, and energy calculations. The typical 8.9 mW power figure suits compact monitoring electronics, and the 20 MHz SPI-compatible interface allows a host controller to configure the AFE and retrieve results efficiently. Front-end protection, anti-alias filtering, and sensor range selection remain necessary for rugged industrial inputs.

🧩

Residential Load Monitoring

For residential load monitoring, the MCP3911A0-E/ML combines two simultaneous 24-bit converters and two PGAs in a compact 4 x 4 mm 20-QFN package. This allows voltage and current information to be digitized close to the sensors, reducing analog trace length and simplifying the signal chain. The internal 1.2 V reference has a stated 9 ppm/°C temperature coefficient, which provides a defined basis for stable measurement. A connected energy-management controller can use the 20 MHz SPI-compatible interface for configuration, calibration access, and periodic energy-data transfer.

🌐

Smart Grid Sensor Interface

The MCP3911A0-E/ML is suitable for smart-grid sensing nodes that must resolve two low-level analog channels and transfer measurements through a digital controller. Simultaneous sampling helps maintain the relationship between voltage and current waveforms, while the two PGA channels support independent conditioning of each path. Its 24-bit resolution, 1.2 V reference, and phase-delay compensation support precise energy calculations. The 20-QFN package preserves board area, while the 2.7 V to 3.6 V supply range allows integration with 3.3 V embedded systems.

🖥️

Energy Metering Test Equipment

The MCP3911A0-E/ML can form the measurement front end of a portable energy-meter tester or calibration platform. Its two simultaneous-sampling 24-bit channels allow paired inputs to be acquired under nearly identical timing conditions, and the internal 1.2 V reference supports repeatable bench measurements. Digital offset and gain calibration features help establish a known measurement baseline. At 8.9 mW typical power and with a 20-QFN footprint, it also supports dense multi-channel test hardware where converter accuracy, synchronization, and board area are important.

🔋

Solar and Battery Energy Management

The MCP3911A0-E/ML can measure low-level system signals in solar or battery-energy management electronics where two synchronized inputs improve the quality of power calculations. Two PGAs prepare each channel for the 24-bit delta-sigma converters, and the phase-compensation block helps align the measurement paths. Operating from 2.7 V to 3.6 V supports 3.3 V system architectures, while the 20-QFN package is useful in compact monitoring boards. The selected gain and reference must preserve headroom for startup transients, changing operating points, and the full input range of the sensors.

Récapitulatif des produits recommandés

MCP3911A0T-E/ML Same-footprint extended-temperature MCP3911 option Utilisé dans : Single-Phase Smart Energy Meter, Industrial Power Monitoring, Smart Grid Sensor Interface, Solar and Battery Energy Management MCP3911A1-E/ML Same-family gain-option candidate Utilisé dans : Single-Phase Smart Energy Meter, Residential Load Monitoring, Energy Metering Test Equipment MCP3911A2-E/ML Same-family programmable-gain candidate Utilisé dans : Industrial Power Monitoring, Energy Metering Test Equipment MCP3911A3-E/ML Same-family programmable-gain candidate Utilisé dans : Residential Load Monitoring, Solar and Battery Energy Management MCP3911A4-E/ML Same-family programmable-gain candidate Utilisé dans : Smart Grid Sensor Interface
What is the MCP3911A0-E/ML used for?
The MCP3911A0-E/ML is a dual-channel, 24-bit analog front end designed primarily for energy-metering and precision analog measurement. It contains two simultaneous-sampling delta-sigma ADCs, two programmable gain amplifiers, a 1.2 V internal reference, phase compensation, and a 20 MHz SPI-compatible interface. According to the Microchip manufacturer datasheet, its dual-channel architecture supports measuring two related signals such as voltage and current from a shared metering system.
What is the operating voltage of MCP3911A0-E/ML?
The MCP3911A0-E/ML operates from 2.7 V to 3.6 V, with 3.3 V as the nominal operating voltage. The Microchip manufacturer datasheet identifies AVDD as operating across this range, and the product is specifically described as a 3.3 V dual-channel energy-metering AFE. The 24-bit converter and digital interface therefore fit systems that use a 3.3 V power rail.
How many ADC channels and bits does MCP3911A0-E/ML have?
The MCP3911A0-E/ML provides two 24-bit ADC channels using simultaneous-sampling delta-sigma converters. The Microchip manufacturer datasheet states that both channels sample synchronously, which helps prevent timing skew between voltage and current measurements. This combination is especially useful in metering designs where two sensor signals must be compared within the same measurement interval.
What is the MCP3911A0-E/ML package and pin count?
The MCP3911A0-E/ML is packaged in a 20-QFN package measuring 4 x 4 mm. The 20-QFN designation indicates 20 perimeter terminals, while the manufacturer’s documentation also describes an exposed thermal pad arrangement for the device family. Use the pin-description table and land-pattern information in the Microchip manufacturer datasheet when assigning PCB tracks and thermal-pad vias.
Where can I download the MCP3911A0-E/ML datasheet PDF?
The official MCP3911A0-E/ML datasheet PDF is available from the Microchip product page and the linked manufacturer document for the MCP3911 family. The manufacturer document provides the electrical characteristics, pin descriptions, calibration architecture, phase-compensation information, and application circuits. It is the preferred source for the exact MCP3911A0-E/ML ordering code, footprint dimensions, and test conditions.
What are the key specifications of MCP3911A0-E/ML that engineers should know?
The MCP3911A0-E/ML combines two simultaneous-sampling 24-bit delta-sigma ADCs, two PGAs, a 1.2 V internal reference, and phase-delay compensation in a 20-QFN package. Its 2.7 V to 3.6 V operating range, 8.9 mW typical power rating, and 20 MHz SPI-compatible interface make it appropriate for compact energy-measurement equipment. These figures come from the Microchip product information and manufacturer datasheet.
Where to buy MCP3911A0-E/ML online?
Use the “Request a Quote” form on this page to request MCP3911A0-E/ML pricing, stock confirmation, minimum order quantity, and lead time for the exact 4 x 4 mm 20-QFN ordering code. The Microchip manufacturer product page identifies the part as an active device, while current quantity, authorized-channel availability, and shipment timing can change. Submitting the form provides a traceable response for your specific production schedule.
What is the price of MCP3911A0-E/ML?
Submit the MCP3911A0-E/ML part number through the “Request a Quote” form on this page to obtain the current unit price and volume pricing. Pricing depends on order quantity, package form, and supply status, and it can change independently of the technical description. The form avoids presenting an outdated unit figure that might not match your required production quantity.
What is the lead time for MCP3911A0-E/ML?
Request the current MCP3911A0-E/ML lead time through the “Request a Quote” form on this page. Lead time depends on the requested quantity, manufacturing schedule, and inventory position, so a quantity-specific quotation is the appropriate way to confirm it. The Microchip manufacturer page identifies MCP3911A0-E/ML as an active catalog part and provides its factory and distribution availability channels.
Is MCP3911A0-E/ML in stock?
Current MCP3911A0-E/ML stock should be confirmed through the “Request a Quote” form on this page. The manufacturer product page shows factory inventory for the exact ordering code, but available quantity can change quickly and may be allocated by order size. The quotation response can include the requested quantity, package form, current availability, and expected shipment timing.
MCP3911A0-E/ML vs MCP3911A0T-E/ML — which is better for an industrial meter?
Choose MCP3911A0-E/ML for the standard temperature grade and MCP3911A0T-E/ML when the extended industrial temperature grade is appropriate for the meter’s specified environmental range. The manufacturer comparison identifies both as two-channel 24-bit AFEs with simultaneous sampling, PGAs, internal reference, phase compensation, and a 20 MHz SPI-compatible interface. Confirm the exact temperature limits and qualification requirements in the Microchip manufacturer datasheet.
What is the difference between MCP3911A0-E/ML and MCP3911A0T-E/ML?
The principal documented distinction between MCP3911A0-E/ML and MCP3911A0T-E/ML is the temperature grade associated with the ordering code. Both retain the MCP3911 dual-channel 24-bit AFE architecture, simultaneous-sampling delta-sigma ADCs, two PGAs, 1.2 V internal reference, and 20-QFN package. The T-grade option is appropriate when the meter must operate across a wider industrial temperature range.
When should I choose MCP3911A0-E/ML over another energy-metering AFE?
Choose MCP3911A0-E/ML when the design requires two simultaneous 24-bit measurements, programmable gain on both channels, phase-delay compensation, and a compact 4 x 4 mm 20-QFN footprint. It is especially suitable for 2.7 V to 3.6 V systems using a 3.3 V digital rail. Select another AFE only when its channel count, package, sampling behavior, or interface offers a specific advantage for the meter.
Is MCP3911A0-E/ML suitable for voltage and current measurement?
Yes, MCP3911A0-E/ML is well suited to paired voltage and current measurement because it provides two simultaneous-sampling 24-bit ADC channels with independent PGAs. Simultaneous sampling minimizes timing differences between the two sensed quantities, while phase-delay compensation supports precision energy calculations. The actual front-end range, sensor output, anti-alias filtering, and isolation must still be designed for the measured voltage and current.
What can replace MCP3911A0-E/ML?
MCP3911A0T-E/ML is the closest same-brand drop-in candidate identified because it retains the MCP3911 20-QFN footprint and dual-channel 24-bit AFE architecture while changing the temperature grade. MCP3911A1-E/ML through MCP3911A4-E/ML are additional same-family candidates with different programmed-gain options, but their configured gain must be checked against the original design. Use the Microchip manufacturer datasheet to verify every pin, electrical limit, and calibration behavior before substitution.

Données de référence d'ingénierie pour MCP3911A0-E/ML — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose MCP3911A0-E/ML for a standard-grade, dual-channel energy-metering design that uses simultaneous 24-bit sampling and a 2.7 V to 3.6 V supply. Choose MCP3911A0T-E/ML when the same electrical architecture is required over an extended industrial temperature range. MCP3911A1-E/ML through MCP3911A4-E/ML can serve as same-footprint alternatives when their programmed-gain configuration matches the sensor range, but each requires gain, offset, and full-scale verification. The MCP3911 family is especially appropriate for paired voltage/current measurement because simultaneous sampling limits timing skew and phase-delay compensation supports power calculations. A different AFE should be considered only if the design requires another package, channel count, interface, reference strategy, or safety architecture.

Comparaison avec les alternatives

Paramètre Ce produit MCP3911A0T-E/ML MCP3911A1-E/ML MCP3911A2-E/ML MCP3911A3-E/ML MCP3911A4-E/ML
Brand Microchip Technology Microchip Technology Microchip Technology Microchip Technology Microchip Technology Microchip Technology
Package QFN-20 (4 x 4 mm) QFN-20 (4 x 4 mm) QFN-20 (4 x 4 mm) QFN-20 (4 x 4 mm) QFN-20 (4 x 4 mm) QFN-20 (4 x 4 mm)
Product Type Dual-channel analog front end Dual-channel analog front end Dual-channel analog front end Dual-channel analog front end Dual-channel analog front end Dual-channel analog front end
ADC Resolution 24 bits 24 bits 24 bits 24 bits 24 bits 24 bits
Channel Count 2 channels 2 channels 2 channels 2 channels 2 channels 2 channels
Supply Voltage Range 2.7 V to 3.6 V 2.7 V to 3.6 V 2.7 V to 3.6 V 2.7 V to 3.6 V 2.7 V to 3.6 V 2.7 V to 3.6 V
Internal Reference 1.2 V, 9 ppm/°C 1.2 V, 9 ppm/°C 1.2 V, 9 ppm/°C 1.2 V, 9 ppm/°C 1.2 V, 9 ppm/°C 1.2 V, 9 ppm/°C
Programmed Gain Configuration MCP3911A0 gain configuration MCP3911A0 gain configuration with extended temperature grade MCP3911A1 gain configuration MCP3911A2 gain configuration MCP3911A3 gain configuration MCP3911A4 gain configuration
Serial Interface Clock 20 MHz SPI compatible 20 MHz SPI compatible 20 MHz SPI compatible 20 MHz SPI compatible 20 MHz SPI compatible 20 MHz SPI compatible

Principaux différenciateurs

  • Simultaneous dual-channel conversion supports paired metering signals (vs MCP3911A0T-E/ML)
  • Programmable-gain alternatives support different signal-conditioning requirements (vs MCP3911A1-E/ML)
  • Compact integration reduces external metering circuitry (vs MCP3911A4-E/ML)

Notes de conception

Follow the Microchip manufacturer reference layout for the 20-QFN footprint, including the exposed thermal pad, pad dimensions, and via pattern. Place the analog input, reference, and decoupling connections directly at their associated pins and keep the SPI traces away from sensitive current and voltage inputs. Because the package is only 4 x 4 mm, routing errors around the exposed pad and fine-pitch terminals can affect assembly yield or introduce coupling between the two measured channels.

Treat the two analog channels as matched measurement paths: use similar input filtering, controlled grounding, and symmetrical routing where practical. Simultaneous sampling reduces timing skew, but it does not remove gain mismatch, phase mismatch, or analog coupling. Configure the PGAs and phase-delay compensation after considering the sensor impedance and anti-alias network so that the digital calibration coefficients describe the complete analog path rather than only the converter.

Decouple the analog and digital supplies at the device pins and keep switching-regulator and digital return currents away from the reference and measurement paths. The MCP3911A0-E/ML is specified for 2.7 V to 3.6 V operation and has a typical power figure of 8.9 mW. Verify supply ripple, startup behavior, and grounding at the system level because the manufacturer’s 24-bit noise and common-mode performance are evaluated under defined test conditions.

Do not change PGA range, reference voltage, or input filtering without repeating offset and gain calibration. A drop-in substitution from the MCP3911A1 through MCP3911A4 families retains the package but changes the programmed-gain configuration, which can alter full-scale utilization and calibration. For MCP3911A0T-E/ML, also verify the temperature grade against the product’s environmental requirements before approving the substitution.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

The manufacturer product information identifies the MCP3911 as a 3.3 V energy-metering AFE but does not provide explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status for this ordering code. The device is not presented as an automotive-qualified AEC-Q100 part.

Recherches associées

MCP3911A0-E/ML datasheet MCP3911A0-E/ML pinout MCP3911A0-E/ML datasheet pdf MCP3911A0-E/ML specifications MCP3911A0-E/ML price MCP3911A0-E/ML stock MCP3911A0-E/ML replacement MCP3911A0-E/ML equivalent MCP3911A0-E/ML vs MCP3911A0T-E/ML MCP3911A0-E/ML QFN-20 footprint Microchip MCP3911A0-E/ML MCP3911A0-E/ML energy metering

Composants & termes associés

Microchip Technology MCP3911A0-E/ML MCP3911A0T-E/ML MCP3911A1-E/ML MCP3911A2-E/ML MCP3911A3-E/ML MCP3911A4-E/ML analog front end AFE delta-sigma ADC energy-metering AFE programmable gain amplifier PGA simultaneous sampling phase-delay compensation internal voltage reference SPI-compatible serial interface QFN-20 4 x 4 mm QFN package surface mount 24-bit ADC voltage and current measurement digital offset and gain calibration single-phase energy meter
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ