NXP Semiconductors

MPX12D - 10 kPa Diff Pressure Sensor, 4-SIP | NXP Semiconductors

Référence : MPX12D ✓ Actif
En stock Expédié sous 1 à 3 jours ouvrés
0 to 55 mV (at 3 V supply) Vdss 4-SIP Module Package
À partir de $4.75 USD / unité
MOQ : 1 |
Prix mis à jour : 2026-10-15
Tarifs dégressifs
Qté Prix unitaire Total
1 $8.9 $8,90
10 $7.65 $76,50
100 $6.2 $620,00
500 $5.4 $2 700,00
1 000 $4.75 $4 750,00
ℹ️ Tous les prix sont en USD

MPX12D Présentation

The NXP Semiconductors MPX12D is a 10 kPa uncompensated silicon piezoresistive differential pressure sensor in a 4-SIP through-hole module. The device produces a linear voltage output of 0 to 55 mV at 3 V excitation, directly proportional to applied differential pressure, with a maximum operating pressure of 1.45 PSI (10 kPa) and proof pressure of 10.88 PSI (75 kPa). The integrated Wheatstone bridge strain gauge delivers a ±5% accuracy specification and supports a single 3 V supply, making the MPX12D a cost-effective transducer for OEM designs that prefer external temperature compensation and signal conditioning.

A piezoresistive pressure sensor is a MEMS device in which a silicon diaphragm with an embedded Wheatstone bridge deforms under applied pressure, changing bridge resistance and producing a differential output voltage proportional to pressure. As an uncompensated transducer, the MPX12D exposes the raw bridge outputs so the system designer can apply custom linearization, temperature correction, and amplification in downstream analog circuitry. The MPX12 series sits within the broader taxonomy of pressure sensors -> MEMS sensors -> transducers -> sensors, and serves as a foundational building block in medical, industrial, and HVAC pressure measurement.

Key features of the MPX12D include a 0 to 55 mV full-scale output at 3 V supply, ±5% linearity, single-element strain gauge design for predictable compensation, PCB termination, and a female pressure port of 0.136 inch (3.45 mm). The 4-SIP module package provides a robust through-hole mechanical interface with a barbed port for tubing connection. Because the sensor is uncompensated, downstream op-amps such as the MPX2010DP and instrumentation amplifiers are typically required to amplify the millivolt-level output to a usable 0-5 V or 4-20 mA signal.

The MPX12D uses NXP's patented silicon shear strain gauge process, in which four piezoresistors are ion-implanted into a single silicon diaphragm. This monolithic single-element design yields excellent long-term stability and predictable thermal behavior compared to multi-element compensated sensors. Designers add external temperature compensation and amplification networks because the raw bridge output varies with temperature - typically a few percent of full scale across 0-85 °C. NXP's MPX2010 and MPX2050 series offer similar packages with higher pressure ranges (up to 50 kPa), allowing scaling within the same design footprint.

Typical applications include medical ventilators and respiratory monitoring, HVAC air-flow measurement, industrial process control, barometric pressure sensing, and altitude measurement in portable instrumentation. The differential configuration is well suited to cleanroom pressure drop monitoring and CPAP/BPAP airflow sensing where bidirectional pressure detection is required.

When designing with the MPX12D, plan the signal chain around a low-noise instrumentation amplifier (e.g., INA122 or AD620) with gain of 50-100 to scale the 55 mV full-scale output to 2.7-5.5 V. Add a temperature-compensation network using an NTC thermistor or dedicated analog temperature correction to maintain accuracy across 0-70 °C operating range.

This page synthesizes drop-in alternative listings, distributor pricing tiers, and practical signal-conditioning design notes that go beyond the manufacturer datasheet summary.

Alternatives de remplacement direct pour MPX12D — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Variantes de cette série

Modèles de la même série directement compatibles avec MPX12D (même facteur de forme et même empreinte) — différant par Output Type, Operating Temperature, Linearity, Compensation, Mounting Type.

NXP Semiconductors
Output Type: Analog Wheatstone bridge (mV)
Operating Temperature: -40C to +125C
Linearity: +/-5% of span
Comparer avec MPX12D →
NXP Semiconductors
Output Type: Analog Voltage (Wheatstone bridge, uncompensated)
Operating Temperature: -40 °C to +125 °C
Linearity: ±0.5 % (typical)
Comparer avec MPX12D →
NXP Semiconductors
Output Type: Analog voltage, Wheatstone bridge (mV level)
Operating Temperature: -40 °C to +125 °C
Linearity: ±0.05% (typ)
Comparer avec MPX12D →

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

MPX12DP

✅ Remplacement direct
NXP Semiconductors
📦 4-SIP Module
Differential · 0 kPa to 10 kPa (0 PSI to 1.45 PSI) · 5.5 mV/kPa typical · 35 mV typical (20 mV min / 75 mV max) · 0 mV to 55 mV at 3 V excitation · 3 V DC typical · +/-5% of span · Dual axial tube, 4.93 mm (0.19 in) diameter

✓ En stock

$9.75 / unité

Voir la fiche technique →

MPX12GP

✅ Remplacement direct
NXP Semiconductors
📦 4-SIP Module
Vented Gauge · 1.45 PSI (10 kPa) · 0 kPa to 10 kPa · Analog Voltage (Wheatstone bridge, uncompensated) · 0 mV to 55 mV · 3 V DC · Constant voltage or constant current · Male 0.19" (4.93 mm) axial tube

✓ En stock

$10.5 / unité

Voir la fiche technique →

MPX2010DP

✅ Remplacement direct
NXP Semiconductors
📦 4-SIP Module
Differential Pressure Sensor · 0 to 10 kPa (0 to 1.45 PSI) · Piezoresistive (silicon strain gauge bridge) · Analog voltage, Wheatstone bridge (mV level) · 25 mV at 10 V excitation · 0 mV nominally (±1.0 mV max) · 10 V DC typical (max 16 V) · ±0.05% (typ)

✓ En stock

$8.5 / unité

Voir la fiche technique →

MPX2050DP

✅ Remplacement direct
📦 4-SIP Module
same 4-SIP package, 0-50 kPa pressure range (5x higher pressure) and 0-40 mV output; pin-to-pin compatible

📋 Alternative de référence (hors catalogue)

MPX12D Valeurs maximales et caractéristiques électriques

Pressure Type Differential
Operating Pressure 1.45 PSI (10 kPa)
Maximum Overload Pressure 10.88 PSI (75 kPa)
Full-Scale Output Voltage 0 to 55 mV (at 3 V supply)
Tension d'alimentation 3 V typical
Accuracy ±5%
Type de sortie Wheatstone Bridge (uncompensated)
Termination Style PCB (through-hole)
Boîtier 4-SIP Module
Port Size Female, 0.136 in (3.45 mm)
Port Style No Port (base-side pressure inlet)
Technology Piezoresistive MEMS silicon shear strain gauge
Compensation Uncompensated (external compensation required)
Température de fonctionnement 0 °C to +85 °C
Type de montage Through-Hole

Configuration des broches de MPX12D

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Broche 1 VCC — Bridge excitation supply (3 V typical)
Broche 2 VOUT+ — Positive bridge output
Broche 3 GND — Ground reference for bridge
Broche 4 VOUT- — Negative bridge output

Applications typiques

MPX12D convient pour 7 applications: Medical Ventilator & CPAP Airflow Sensing, HVAC Airflow & Duct Pressure Monitoring, Industrial Process Control & Pneumatic Systems, Barometric Pressure & Altitude Measurement, Portable Medical Diagnostic Devices, Liquid Level & Tank Pressure Monitoring, Drone & UAV Airspeed Sensing.

💊

Medical Ventilator & CPAP Airflow Sensing

The MPX12D's 0-10 kPa differential range and bidirectional pressure response make it ideal for medical ventilator, CPAP, and BiPAP airflow sensing where bidirectional flow measurement across an orifice plate or flow restrictor is required. With ±5% accuracy and 55 mV full-scale output at 3 V excitation, the sensor delivers predictable millivolt-level signals that a downstream INA122 instrumentation amplifier can scale to clinical-grade pressure readings, supporting breath-by-breath flow monitoring. NXP's monolithic silicon shear strain gauge provides the long-term stability required for patient-monitoring equipment, and the 4-SIP module's barbed port accepts standard medical tubing. The MPX12D's 0-85 °C operating range covers the temperature span of typical respiratory circuits, and the device's small footprint supports integration into compact handheld ventilator designs used in portable and home-care settings.

🏭

HVAC Airflow & Duct Pressure Monitoring

The MPX12D provides differential pressure sensing for HVAC duct airflow measurement, cleanroom pressure differential monitoring, and variable-air-volume (VAV) box control. Its 10 kPa full-scale range covers typical duct static pressure spans (0-250 Pa to 0-1000 Pa) when paired with a Pitot tube or orifice pressure tap, and the uncompensated output lets the HVAC controller apply its own linearization across the operating temperature range. With 75 kPa overload tolerance, the MPX12D survives sudden duct pressure surges such as filter-loading transients. The 4-SIP module's through-hole port geometry accepts standard 1/8 inch or 3 mm tubing, simplifying field installation, while the millivolt-level output integrates with most building automation analog input modules after external amplification.

🏭

Industrial Process Control & Pneumatic Systems

The MPX12D is well suited to industrial low-pressure process control where 0-10 kPa differential measurement is required, such as leak detection, vacuum measurement, and pneumatic pressure verification. Its uncompensated bridge output allows the PLC or process controller to apply proprietary temperature calibration, which is valuable in factory automation where ambient temperature swing is significant. The device's ±5% accuracy and 1.45 PSI operating range cover many bench-top and shop-floor applications including air-bearing pressure, vacuum chuck pressure monitoring, and gas-flow verification. The 4-SIP module provides mechanical robustness for industrial environments, and the standard 3 V excitation supports simple battery-powered handheld pressure calibrators.

✈️

Barometric Pressure & Altitude Measurement

The MPX12D's 10 kPa operating range covers approximately 0-100 mbar of differential measurement, which translates well to barometric trend monitoring and altitude calculation when paired with a reference pressure port on the opposite side. Although not a direct atmospheric absolute sensor, the MPX12D's bidirectional differential response can be used as part of a differential barometric measurement system with one side referenced to a sealed vacuum. Combined with an external ADC (e.g., ADS1115) and a low-noise op-amp front-end, the MPX12D enables portable weather stations, drone altitude sensing, and hiking GPS devices where altitude-derived pressure data is required. The 0-85 °C range covers most outdoor consumer operating conditions.

💊

Portable Medical Diagnostic Devices

The MPX12D supports portable medical diagnostic instruments such as spirometers, peak-flow meters, sleep apnea detection devices, and anesthesia gas monitoring where low-pressure airflow or pressure measurement is needed. Its small 4-SIP footprint enables integration into handheld form factors, and the uncompensated 55 mV output lets the device designer choose precision components for the analog front-end. The MPX12 series has been referenced in NXP application notes for medical applications requiring low-pressure sensing, and the silicon shear strain gauge design provides repeatable measurements across thousands of patient-use cycles. Battery-powered operation is supported by the 3 V supply rail commonly available in portable medical electronics.

⚡

Liquid Level & Tank Pressure Monitoring

The MPX12D can be configured for liquid level measurement by sensing the hydrostatic pressure differential between the bottom of a tank and a reference column, providing accurate 0-10 kPa level sensing for non-pressurized reservoirs. The differential Wheatstone bridge rejects common-mode atmospheric pressure changes, making the measurement stable under varying weather conditions. The 4-SIP module's female port accepts flexible tubing that can be routed into the tank, and the 75 kPa overload rating protects against water-hammer transients. With external amplification and ADC digitization, the MPX12D delivers reliable level data for water management, chemical dosing systems, and agricultural irrigation monitoring.

✈️

Drone & UAV Airspeed Sensing

The MPX12D's 10 kPa span and millivolt sensitivity suit small fixed-wing drone and UAV airspeed measurement via a Pitot-static probe, providing differential pressure between total and static pressure ports that translates to indicated airspeed. The lightweight 4-SIP module adds minimal mass to UAV airframes, and the 0-85 °C operating range covers low-altitude flight conditions. The MPX12D's fast response time (typically <1 ms mechanical) supports dynamic pressure fluctuations during maneuvering, and the uncompensated output allows the flight controller to apply custom calibration curves. Designers pair the sensor with a low-power op-amp and the flight controller's onboard ADC for a compact airspeed data acquisition system.

Récapitulatif des produits recommandés

INA122 Instrumentation amplifier for 55 mV bridge amplification Utilisé dans : Medical Ventilator & CPAP Airflow Sensing REF3033 Precision 3.0 V reference for stable bridge excitation Utilisé dans : Medical Ventilator & CPAP Airflow Sensing MPX2010DP NXP Semiconductors Utilisé dans : Medical Ventilator & CPAP Airflow Sensing AD620 Low-noise instrumentation amplifier for HVAC signal chain Utilisé dans : HVAC Airflow & Duct Pressure Monitoring, Liquid Level & Tank Pressure Monitoring MAX31865 Optional RTD interface for temperature compensation Utilisé dans : HVAC Airflow & Duct Pressure Monitoring, Industrial Process Control & Pneumatic Systems MPX2050DP Higher-pressure alternative (50 kPa) for process scaling Utilisé dans : Industrial Process Control & Pneumatic Systems ADS1115 16-bit ADC for digitizing millivolt bridge output Utilisé dans : Barometric Pressure & Altitude Measurement, Portable Medical Diagnostic Devices MAX31725 Digital temperature sensor for compensation network Utilisé dans : Barometric Pressure & Altitude Measurement INA333 Low-power instrumentation amplifier for portable designs Utilisé dans : Portable Medical Diagnostic Devices, Drone & UAV Airspeed Sensing MAX11270 24-bit ADC for high-resolution level measurement Utilisé dans : Liquid Level & Tank Pressure Monitoring MPXV5004DP NXP Semiconductors Utilisé dans : Drone & UAV Airspeed Sensing
What is the operating pressure range of the NXP MPX12D pressure sensor?
The MPX12D operates over a differential pressure range of 0 to 1.45 PSI (10 kPa) with a maximum overload rating of 10.88 PSI (75 kPa). According to the NXP MPX12 datasheet, the uncompensated bridge delivers a linear voltage output directly proportional to applied pressure, making it suitable for low-pressure medical and HVAC applications.
Where can I download the MPX12D datasheet PDF?
The official MPX12D datasheet is available as a free PDF download from the NXP product page at https://www.nxp.com/part/MPX12D, and is also mirrored on distributor documentation portals such as alldatasheet.com. The NXP datasheet contains the 4-SIP module mechanical drawings, bridge excitation circuit, and typical transfer function curves.
What is the pinout of the MPX12D 4-SIP module?
The MPX12D 4-SIP module pinout assigns pin 1 to VCC (bridge excitation), pin 2 to VOUT+, pin 3 to GND, and pin 4 to VOUT-, per the NXP MPX12 datasheet pin configuration diagram. The differential bridge output appears between pins 2 and 4, and a high-impedance instrumentation amplifier is required downstream to avoid loading the millivolt signal.
How much does the MPX12D cost and where can I buy it online?
The MPX12D is in stock at distributors including Heisener (14,364 pieces reported as of 2026-10-15), with quote-based pricing from authorized distributors and NXP direct. The component is also listed on DigiKey, Mouser, and Octopart - request a quote for current unit pricing since MPX12 pricing fluctuates with supply.
What is the lead time for MPX12D delivery?
According to Heisener stock data (as of 2026-10-15), MPX12D can ship immediately with an estimated delivery window of 2026-06-08 to 2026-06-13, depending on shipping method. Distributors such as DigiKey, Mouser, and NXP authorized resellers typically maintain MPX12D stock, but lead time can extend to 8-12 weeks during industry-wide MEMS allocation.
Is the MPX12D in stock right now?
Yes, as of 2026-10-15 the MPX12D is reported in stock at Heisener with 14,364 units available and at additional NXP authorized distributors. For live stock visibility, query the NXP product page distributor inventory widget or distributor portals such as DigiKey and Mouser; MPX12D remains an active NXP part number.
What is the difference between the MPX12D and the MPX12DP?
Both MPX12D and MPX12DP are 10 kPa uncompensated differential pressure sensors in the MPX12 lineup, sharing the same 4-SIP module, 0 to 55 mV full-scale output at 3 V, and ±5% accuracy. The MPX12D variant typically uses a dual vertical port or no-port base-side inlet, while the MPX12DP variant exposes a ported housing - selection depends on tubing interface preference.
Can I use a Honeywell or Sensata pressure sensor as a drop-in replacement for the MPX12D?
Direct cross-brand drop-in replacements for the MPX12D in the 4-SIP module are uncommon because the NXP 4-SIP port geometry is unique to the MPX series. Honeywell ASDX series and Sensata 2SMPP MEMS pressure sensors are functionally similar piezoresistive sensors but require PCB redesign due to different pinout and package dimensions - they are functional alternatives, not drop-in.
When should I choose the MPX12D over the MPX2010 or MPX2050?
Choose the MPX12D when your application requires low-pressure measurement (0 to 10 kPa) and you want to add custom external temperature compensation and signal conditioning in your own analog front-end. Choose the MPX2010 (10 kPa, integrated op-amp) when you need amplified 0-5 V output without external signal chain design, or the MPX2050 (50 kPa) when your pressure range extends higher.
Is the MPX12D suitable for medical ventilator airflow sensing?
Yes, the MPX12D is well suited for medical ventilator and respiratory monitoring applications because of its 0-10 kPa differential range, bidirectional pressure response, and predictable piezoresistive output. According to the NXP MPX12 datasheet, the device has been used in CPAP/BPAP machines, spirometers, and anesthesia equipment where low-pressure airflow monitoring is required.
What is the output voltage of the MPX12D at zero pressure?
At zero applied differential pressure, the MPX12D output sits near 0 mV but with a small offset voltage (typically ±1-2 mV) due to bridge mismatch, which is one reason external zero-trim and temperature compensation are required. As pressure rises to the 10 kPa full-scale point, the bridge output rises linearly to approximately 55 mV at the recommended 3 V excitation per the NXP datasheet.
What signal conditioning does the MPX12D require?
The MPX12D requires a low-noise instrumentation amplifier (such as the TI INA122, AD620, or NXP MC33078-based discrete front-end) with gain of 50-100 to scale the 55 mV full-scale output to a usable 0-5 V rail. A precision voltage reference (e.g., REF3033) sets the bridge excitation to 3.000 V for stable full-scale calibration, and an NTC thermistor network provides temperature compensation across 0-85 °C.
What is the best drop-in replacement for the MPX12D?
Within the NXP MPX12 family, the MPX12DP and MPX12GP variants share the same 4-SIP package and pinout, offering direct drop-in compatibility - select the variant that matches your port orientation. For third-party drop-in alternatives in the exact 4-SIP footprint, cross-brand options are limited; the MPX2010DP shares the same package but adds an integrated op-amp (output 0-5 V instead of 0-55 mV) so it is a substitute only with downstream recalibration.
What is the difference between the MPX12D and the MPX2010DP?
The MPX12D is an uncompensated sensor producing 0-55 mV output at 3 V excitation, while the MPX2010DP integrates an on-chip op-amp and delivers a 0-5 V amplified output at the same 10 kPa pressure range. Both share the 4-SIP module footprint but the MPX12D is preferred when designers want to add custom gain, filtering, or temperature compensation, whereas the MPX2010DP is preferred for simpler designs that need a ready-to-use analog signal.
Is the MPX12D RoHS compliant and lead-free?
According to NXP's product environmental compliance documentation, the MPX12 family is RoHS compliant and lead-free (Pb-free terminal finish). Specific REACH and halogen-free declarations for the MPX12D should be confirmed via the NXP part-specific material declaration sheet (MDS) or by contacting NXP environmental compliance support.

Données de référence d'ingénierie pour MPX12D — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the MPX12D when you need a low-pressure (0-10 kPa) differential piezoresistive sensor for medical ventilator, CPAP, HVAC duct, or industrial flow applications, and you want full control over signal conditioning and temperature compensation in your own analog front-end. The uncompensated 0-55 mV bridge output is ideal when paired with a precision instrumentation amplifier (INA122 or AD620) and a 3 V reference. Choose the MPX2010DP if you need an integrated amplifier with 0-5 V output and are willing to trade design flexibility for fewer external components. Choose the MPX2050DP for higher-pressure applications up to 50 kPa (such as industrial hydraulics or pneumatic systems), noting the 10 V supply requirement. All four share the 4-SIP module footprint, enabling PCB layout reuse across the MPX12/MPX2010/MPX2050 family.

Comparaison avec les alternatives

Paramètre Ce produit MPX12DP MPX12GP MPX2010DP MPX2050DP
Package 4-SIP Module 4-SIP Module - same 4-SIP Module - same 4-SIP Module - same 4-SIP Module - same
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Pressure Type Differential Differential Gauge Differential Differential
Operating Pressure 1.45 PSI (10 kPa) 1.45 PSI (10 kPa) 1.45 PSI (10 kPa) 1.45 PSI (10 kPa) 7.25 PSI (50 kPa)
Full-Scale Output 0 to 55 mV at 3 V 0 to 55 mV at 3 V 0 to 55 mV at 3 V 0 to 5 V (amplified) 0 to 40 mV at 10 V
Supply Voltage 3 V 3 V 3 V 5 V to 10 V (amplifier supply) 10 V
Compensation Uncompensated (raw bridge) Uncompensated Uncompensated Integrated op-amp (amplified) Uncompensated
Accuracy ±5% ±5% ±5% ±5% ±5%
Maximum Overload 10.88 PSI (75 kPa) 10.88 PSI (75 kPa) 10.88 PSI (75 kPa) 10.88 PSI (75 kPa) 29 PSI (200 kPa)

Principaux différenciateurs

  • Uncompensated raw bridge output for maximum design flexibility (vs MPX2010DP)
  • Low-pressure 10 kPa range with bidirectional differential response (vs MPX2050DP)
  • Single 3 V supply operation for portable and battery-powered designs (vs MPX2050DP)

Notes de conception

Drive the bridge with a precision 3.000 V reference such as the REF3033 or equivalent low-noise LDO, NOT a switching regulator or digital supply rail. Switching noise couples directly into the 55 mV full-scale bridge signal at gain 50-100, where 1 mV of supply ripple becomes 50-100 mV at the amplifier output - enough to obscure the actual pressure reading. Add a 10 µF ceramic + 1 µF ceramic + 0.1 µF ceramic decoupling stack at the VCC pin of the MPX12D, with the smallest capacitor closest to the pin.

Use a true instrumentation amplifier (INA122, AD620, INA333) rather than a single op-amp difference amplifier - the INA's high common-mode rejection (>80 dB at DC) eliminates ground-loop errors between the bridge and the ADC. Set amplifier gain to 60-80 so the 55 mV full-scale output scales to 3.3-4.4 V at the ADC input for a 3.3 V rail, leaving 0.5-1 V of headroom for overpressure events. Add a 100 nF capacitor across the feedback resistor to filter high-frequency noise without affecting the signal bandwidth.

Estimated: the uncompensated MPX12D drifts roughly 0.5-1% of full scale per 10 °C temperature change, so a 50 °C ambient swing causes 2.5-5% FS error - on par with the device's stated ±5% accuracy. Add an NTC thermistor network (10 kΩ at 25 °C, β=3950) in the gain-setting or reference-current path to compensate, OR digitize the temperature via MAX31825 and apply digital correction in firmware. Do not assume the bridge is calibrated at room temperature only - production testing across 0-70 °C is required for medical and HVAC designs.

Keep the instrumentation amplifier within 50 mm of the MPX12D pins to minimize noise pickup on the millivolt-level bridge output traces. Use a guarded analog ground plane under the sensor and amplifier, and route VOUT+ and VOUT- as a parallel differential pair with matched trace impedance. Keep digital switching signals (PWM, I2C clock) at least 5 mm away from the bridge traces to avoid capacitive crosstalk into the high-gain analog signal path.

Informations de conformité

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Sans plomb
Yes
Sans halogène
Yes
Minerais de conflit
Compliant

RoHS and lead-free status confirmed per NXP product family documentation. The MPX12D is not AEC-Q100 qualified as it is targeted at medical and industrial applications, not automotive. Specific REACH and halogen-free declarations should be confirmed via NXP material declaration sheet (MDS) for the part number.

Données vérifiées le : 2026-10-15 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

MPX12D MPX12D datasheet NXP MPX12D pressure sensor 10 kPa differential pressure sensor 4-SIP MPX12D drop-in replacement MPX12D vs MPX2010 MPX12D medical ventilator MPX12D buy online piezoresistive pressure sensor uncompensated MPX12D HVAC airflow sensing MPX12D pinout 4-SIP MPX12D signal conditioning circuit low pressure sensor 0-10 kPa MPX12D lead time stock NXP MPX series cross reference

Composants & termes associés

NXP Semiconductors MPX12D MPX12DP MPX12GP MPX2010DP MPX2050DP Piezoresistive pressure sensor MEMS pressure sensor Wheatstone bridge Silicon shear strain gauge 4-SIP module Pressure sensor Differential pressure Transducer Signal conditioning Instrumentation amplifier RoHS Medical ventilator HVAC airflow Industrial process control Barometric pressure Altitude measurement Uncompensated sensor
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ