NVIDIA

MSN3700-VS2RO - 200GbE 32x QSFP56 Spectrum-2 Switch | NVIDIA

Référence : MSN3700-VS2RO ✓ Actif
En stock Expédié sous 1 à 3 jours ouvrés
1GbE to 400GbE (per SN3000 series platform) Speed
À partir de $26200 USD / unité
MOQ : 1 |
Prix mis à jour : 2026-10-18
Tarifs dégressifs
Qté Prix unitaire Total
1 $29246.99 $29 246,99
10 $28350 $283 500,00
25 $27600 $690 000,00
50 $26950 $1 347 500,00
100 $26200 $2 620 000,00
ℹ️ Tous les prix sont en USD

MSN3700-VS2RO Présentation

The NVIDIA Mellanox MSN3700-VS2RO is a 200GbE Open Ethernet switch based on the Spectrum-2 ASIC, delivering 12.8 Tbps of switching capacity through 32 QSFP56 ports in a 1U rack-mount chassis with standard depth, connector-to-power (C2P) airflow, dual AC power supplies, an x86 CPU, and an ONIE boot loader.

A data center Ethernet switch is a managed networking device that aggregates and routes traffic between servers at the leaf, spine, or super-spine layer of a fabric hierarchy. Within the broader networking hierarchy, the MSN3700-VS2RO sits in the top-of-rack or end-of-row switch category, which in turn belongs to the Ethernet switch family of network switching equipment. Open Ethernet switches such as this one ship with ONIE, allowing installation of a choice of network operating systems rather than a locked-in vendor OS.

Key features include 32 QSFP56 ports supporting speeds from 1GbE up to 200GbE per port, 12.8 Tbps non-blocking capacity, redundant hot-swappable 2x AC power supplies, and connector-to-power airflow for predictable thermal management in data center hot/cold aisle layouts. The integrated x86 management CPU enables full-featured NOS deployment including NVIDIA Onyx or Cumulus Linux.

Technically, the Spectrum-2 generation ASIC provides deep buffering and flexible port bifurcation (for example, a 200G port split into 2x100G or 4x50G), enabling mixed-speed rack connectivity. Port speeds span 1GbE to 400GbE across the SN3000 series platform family, giving fabric designers flexibility in leaf/spine blocking ratios.

Typical applications include high-density 100G/200G leaf-spine data center fabrics, super-spine aggregation layers, cloud and enterprise top-of-rack aggregation, and storage network backends where 200GbE uplinks reduce oversubscription.

When deploying, verify rack airflow direction compatibility (C2P versus P2C variants exist in the same family) and confirm AC power feed redundancy before installation.

This page synthesizes distributor pricing, drop-in SKU alternatives, and practical deployment notes not found in the manufacturer datasheet.

Alternatives de remplacement direct pour MSN3700-VS2RO — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Variantes de cette série

Modèles de la même série directement compatibles avec MSN3700-VS2RO (même facteur de forme et même empreinte) — différant par Airflow, Form Factor, Power Supplies, Management, ASIC.

NVIDIA
Airflow: P2C (back-to-front)
Form Factor: 1U rack-mountable
Power Supplies: 2 x AC, redundant (100-264 V)
Comparer avec MSN3700-VS2RO →
NVIDIA
Airflow: C2P (Connector-to-Power)
Form Factor: 1U rack-mountable, standard depth
Power Supplies: 2 x AC, redundant
Comparer avec MSN3700-VS2RO →
NVIDIA
Airflow: P2C (port-to-connector)
Form Factor: 1U rack-mount
Power Supplies: 2x AC PSU (redundant, hot-swappable)
Comparer avec MSN3700-VS2RO →

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

MSN3700-VS2F

✅ Remplacement direct ⚠️ Spécifications non vérifiées
📦 1U rack-mount, 32x QSFP56
same 32x QSFP56 200GbE Spectrum-2 1U chassis; airflow/PSU suffix configuration differs (F vs RO airflow-power configuration), verify PSU type before swap

📋 Alternative de référence (hors catalogue)

MSN3700-CS2FC

✅ Remplacement direct ⚠️ Spécifications non vérifiées
NVIDIA
📦 1U rack-mount, 32x QSFP56
1U managed L3 Ethernet switch · Mellanox Spectrum-2 · 32 x 100GbE QSFP28 · 6.4 Tbps · 4.76 Bpps · 425 ns · 1GbE to 100GbE (splittable to 128 x 10/25GbE) · 1U rack-mountable

✓ En stock

$1 / unité

Voir la fiche technique →

MSN3700-CS2RO

✅ Remplacement direct ⚠️ Spécifications non vérifiées
NVIDIA
📦 1U rack-mount, 32x QSFP56
1U Open Ethernet switch (bare metal, ONIE) · NVIDIA Spectrum-2 (SN3700C) · 32 x 100GbE QSFP28 · Up to 100 Gb/s per port (1GbE to 400GbE across SN3000 series) · 12.8 Tb/s · Up to 8.33 Bpps · L3 managed · ONIE (Open Network Install Environment)

✓ En stock

$8300 / unité

Voir la fiche technique →

MSN3700-VS2FC

✅ Remplacement direct
NVIDIA
📦 1U rack-mount, 32x QSFP56
NVIDIA Spectrum SN3000 (SN3700) · NVIDIA Spectrum-2 · 32 QSFP56 ports · Up to 200GbE per port (series supports 1GbE to 400GbE) · 12.8 Tb/s · 1U rack-mount · Standard depth · 2x AC PSU (redundant, hot-swappable)

✓ En stock

$9100 / unité

Voir la fiche technique →

MSN3700-VS2R

✅ Remplacement direct
📦 1U rack-mount
same 1U Spectrum-2 12.8 Tbps platform but 48x SFP28 + 12x QSFP28 (25/100G) instead of 32x QSFP56 (200G); same rack slot, different port topology

📋 Alternative de référence (hors catalogue)

SSE-SN3700-VS2RC

✅ Remplacement direct
📦 1U rack-mount, 32x 200G ports
cross-brand equivalent using same NVIDIA Spectrum-2 ASIC, 32x 200G, 12.8 Tbps, 1U; however listed EOL by Supermicro, available only as channel remainder

📋 Alternative de référence (hors catalogue)

MSN3700-VS2RO Spécifications (publiées par le fabricant)

Network Type Ethernet (200GbE Open Ethernet switch)
ASIC Family NVIDIA Spectrum-2
Total Switching Capacity 12.8 Tbps
Port Count 32 x QSFP56
Port Speeds 1GbE to 400GbE (per SN3000 series platform)
Form Factor 1U rack-mount, standard depth
Airflow Connector-to-Power (C2P)
Power Supplies 2 x AC (redundant)
Management CPU x86 CPU
Boot Loader ONIE (Open Network Install Environment)
NVIDIA SKU 920-9N201-00RA-0N0
Management Managed
Température de fonctionnement 0 C to +40 C
Non-Operational Temperature -40 C to +70 C
Accessories Included Rail kit
UNSPSC Code 43222612

Interfaces et connecteurs du MSN3700-VS2RO

Aucune liste d'interfaces publiée par le fabricant n'est disponible pour le MSN3700-VS2RO. Consultez la documentation du fabricant pour les détails des connecteurs et des embases.

Consultez la documentation du fabricant pour le brochage complet du connecteur d'extension et la numérotation des broches du connecteur.

Caractéristiques de puissance et thermiques

Température de fonctionnement 0 C to +40 C

Paramètres d'alimentation et thermiques pour MSN3700-VS2RO tels que publiés par le fabricant.

Applications typiques

MSN3700-VS2RO convient pour 6 applications: 200G Spine Layer Switching, High-Density Leaf Switching, Super-Spine Aggregation, Cloud and Enterprise Data Center Fabrics, Storage Network Backend, High-Performance Computing Interconnect On-Ramp.

🌐

200G Spine Layer Switching

The MSN3700-VS2RO fits spine roles in leaf-spine fabrics where 32 x QSFP56 ports at up to 200GbE provide 12.8 Tbps of non-blocking bisection bandwidth. Each 200G port can bifurcate into 2 x 100G or 4 x 50G connections, allowing a single spine chassis to connect 64 leaf switches at 100G or 128 at 50G. The Spectrum-2 ASIC's deep buffering absorbs incast congestion typical of East-West traffic, while redundant 2x AC PSUs and C2P airflow match standard spine rack power and cooling designs. Running EVPN-VXLAN or BGP underlay via an ONIE-installed NOS delivers deterministic fabric convergence.

🖥️

High-Density Leaf Switching

As a leaf switch, the MSN3700-VS2RO aggregates servers via 100G/50G breakout connections from its 32 QSFP56 ports while pushing 200G uplinks to the spine, minimizing oversubscription. The 12.8 Tbps Spectrum-2 capacity supports full 64 x 100G server connectivity per switch, and ONIE compatibility lets operators standardize on Cumulus Linux or NVIDIA Onyx across the leaf layer for automation with Ansible or JSON-RPC. The 0 C to +40 C operating range and standard-depth 1U chassis fit conventional top-of-rack deployments; C2P airflow requires the switch front face at the cold aisle.

🌐

Super-Spine Aggregation

In three-tier data center topologies, the MSN3700-VS2RO serves as a compact super-spine, interconnecting multiple spine blocks over 200G links. With 32 QSFP56 ports it consolidates up to 32 spine-block uplinks, and its Spectrum-2 ASIC forwarding performance sustains line-rate 200G forwarding across all ports for 12.8 Tbps aggregate. The x86 CPU hosts the NOS control plane and telemetry agents for intent-based fabric monitoring. Dual AC power supplies protect against feed loss in the aggregation core, where a chassis outage affects multiple racks; 0-40 C ratings suit dedicated core distribution rooms.

🧩

Cloud and Enterprise Data Center Fabrics

Cloud providers and large enterprises deploy the MSN3700-VS2RO where Open Ethernet economics matter: the ONIE boot loader frees operators from vendor-locked NOS licensing and supports open-source switch platforms. Port speeds spanning 1GbE to 400GbE within the SN3000 series let one hardware family serve management, storage, and compute fabrics, simplifying spares pools and automation templates. The 12.8 Tbps capacity with deep buffering handles bursty object-storage and virtualization traffic, while rail-kit mounting and standard 1U depth ease high-density rack integration in colocation environments.

🖥️

Storage Network Backend

NVMe-oF and distributed storage clusters benefit from the MSN3700-VS2RO's 200G backend links, which keep 100G storage nodes fully non-oversubscribed. The Spectrum-2 ASIC's large packet buffer absorbs read/write bursts from parallel filesystem traffic without drops, and 32 ports at 200G connect storage arrays, compute nodes, and head units in a single tier. Redundant hot-swappable AC PSUs and managed QoS via NVIDIA Onyx preserve latency-sensitive storage traffic classes. The 0-40 C operating envelope covers typical storage aisles; C2P airflow aligns with cold-aisle intake conventions.

✈️

High-Performance Computing Interconnect On-Ramp

HPC sites running NVIDIA InfiniBand cores use the MSN3700-VS2RO as the Ethernet side of the fabric - connecting login nodes, management networks, and parallel filesystems to compute resources. Its Spectrum-2 architecture shares silicon lineage with Mellanox switching platforms, easing gateway integration, and 12.8 Tbps capacity sustains all-gather and IO-heavy workloads crossing the Ethernet boundary. ONIE-based NOS flexibility suits sites standardizing on open networking stacks, and the standard-depth 1U chassis with C2P airflow drops directly into HPC racks cooled front-to-back within the 0-40 C ambient envelope.

Récapitulatif des produits recommandés

MQM8790 Higher-bandwidth 40x 200G HDR InfiniBand alternative for converged fabrics Utilisé dans : 200G Spine Layer Switching MSN3700-VS2FC NVIDIA Utilisé dans : 200G Spine Layer Switching, Cloud and Enterprise Data Center Fabrics SN3700-VS2R 25G/100G breakout leaf variant for dense server fanout Utilisé dans : High-Density Leaf Switching, Storage Network Backend ConnectX-6 Dx Server NIC for 100G/200G leaf attachment Utilisé dans : High-Density Leaf Switching, High-Performance Computing Interconnect On-Ramp MSN3700-VS2RO NVIDIA Utilisé dans : Super-Spine Aggregation SN4700 Spectrum-4 based 400G upgrade path Utilisé dans : Super-Spine Aggregation BlueField-2 DPU for secure, offloaded east-west traffic at leaf endpoints Utilisé dans : Cloud and Enterprise Data Center Fabrics ConnectX-6 200G server/storage adapter for backend network Utilisé dans : Storage Network Backend MQM9790 HDR InfiniBand switch for the compute core it fronts Utilisé dans : High-Performance Computing Interconnect On-Ramp
What is the NVIDIA Mellanox MSN3700-VS2RO switch?
The MSN3700-VS2RO is a 200GbE Open Ethernet switch based on the NVIDIA Spectrum-2 ASIC, providing 12.8 Tbps of capacity via 32 QSFP56 ports in a 1U standard-depth chassis. It ships with an ONIE boot loader, an x86 management CPU, dual AC power supplies, and connector-to-power (C2P) airflow, and is purpose-built for high-density leaf, spine, and super-spine data center fabrics. According to the NVIDIA SN3000 series datasheet, the platform spans port speeds from 1GbE to 400GbE.
How much does the MSN3700-VS2RO cost?
The MSN3700-VS2RO is priced at approximately $29,246.99 for a single new unit as of 2026-10-19, based on the Zones.com retail listing. Volume purchases typically receive tiered discounts from resellers and stocking distributors; refurbished units from vendors such as BrightStar Systems are available at significantly lower prices with warranty. For exact quantity pricing above 10 units, request a quote since channel pricing for data center switches is negotiated rather than published in fixed tier tables.
Where can I buy the MSN3700-VS2RO online?
The MSN3700-VS2RO can be purchased new from resellers such as Zones.com (listed at $29,246.99 as of 2026-10-19), Router-Switch.com, 4StarTech.com, and ITBargainCenter.com, or as tested and warrantied refurbished stock from BrightStar Systems. XAIPART also accepts quote requests for this SKU. When ordering, always confirm the exact suffix: the -VS2RO variant specifies standard depth, 2x AC PSU, and C2P airflow, which must match your rack power and airflow environment.
What is the difference between MSN3700-VS2RO and MSN3700-VS2R?
The MSN3700-VS2R (per datasheets.com) is a Spectrum-2 based 1U switch configured with 48 SFP28 ports plus 12 QSFP28 ports running 25GbE/100GbE, while the MSN3700-VS2RO provides 32 QSFP56 ports at up to 200GbE. Both use the same 12.8 Tbps Spectrum-2 ASIC family, but port topology and maximum per-port speed differ, so they are complementary configurations rather than substitutes; choose based on whether your servers use 25/100G breakout cabling or 100/200G QSFP56 optics.
What is the difference between MSN3700-VS2RO and MSN3700-VS2FC?
Both the MSN3700-VS2RO and MSN3700-VS2FC are 32-port QSFP56 200GbE Spectrum-2 switches in 1U. The suffix letters encode configuration: -VS2FC differs in PSU type and airflow direction (the FC variant uses port-to-power airflow and a different power supply configuration, while the RO variant is standard depth with 2x AC supplies and connector-to-power airflow). According to NVIDIA ordering documentation, airflow direction must match rack cooling design, so select the suffix that matches your hot/cold aisle layout.
What is the best drop-in replacement for the MSN3700-VS2RO?
The closest drop-in replacements are same-family MSN3700 Spectrum-2 SKUs: the MSN3700-VS2F and MSN3700-CS2FC/CS2RO variants share the identical 1U chassis, 32 QSFP56 ports, 12.8 Tbps Spectrum-2 ASIC, ONIE loader, and x86 CPU, differing mainly in airflow direction, PSU type, or depth. Cross-brand, the Supermicro SSE-SN3700-VS2RC uses the same Spectrum-2 silicon in a 1U 32-port 200G form factor, though it is now discontinued (EOL) per Supermicro. Verify PSU type and airflow suffix before ordering any replacement.
Can the Supermicro SSE-SN3700-VS2RC replace an MSN3700-VS2RO?
Functionally yes at the hardware level: the Supermicro SSE-SN3700-VS2RC is also a Spectrum-2 based 1U switch with 32 x 200G ports and 12.8 Tbps throughput, so it fits the same rack slot and port plan. However, it is listed as a discontinued SKU by Supermicro, so availability is limited to remaining channel stock, and its BIOS/management firmware differs from the NVIDIA ONIE-based system. For new deployments, a same-family NVIDIA MSN3700 variant is the safer functional drop-in.
When should I choose the MSN3700-VS2RO over the MSN3700-VS2R?
Choose the MSN3700-VS2RO when your fabric needs maximum bandwidth per rack with fewer, faster ports - 32 QSFP56 ports at up to 200GbE with bifurcation options. Choose the MSN3700-VS2R when you have many 25GbE or 100GbE server connections, since its 48 SFP28 plus 12 QSFP28 layout provides direct 25G connectivity without breakout cables. Both deliver the same 12.8 Tbps Spectrum-2 capacity; the decision is port density and per-port speed, not raw throughput.
Is the MSN3700-VS2RO suitable for a leaf-spine data center fabric?
Yes - the MSN3700-VS2RO is purpose-built for leaf, spine, and super-spine roles. Its 12.8 Tbps non-blocking capacity across 32 QSFP56 ports supports 64 x 100G or 128 x 50G breakouts for leaf connectivity, while 200G spine uplinks minimize oversubscription. The ONIE boot loader lets you run NVIDIA Onyx, Cumulus Linux, or third-party NOS images supporting standard leaf-spine routing protocols such as BGP and EVPN, and C2P airflow matches standard cold-aisle-to-hot-aisle rack layouts.
What is the operating temperature range of the MSN3700-VS2RO?
The MSN3700-VS2RO operates from 0 C to +40 C ambient and tolerates -40 C to +70 C when non-operational (storage), according to the 4StarTech product specification listing. This range is typical for data center grade equipment and assumes proper front-to-back (C2P) airflow with unobstructed intake. Deployments above 40 C ambient, such as free-cooling or hot-aisle containment designs exceeding the limit, would require the ASHRAE-extended variants or forced derating - confirm with NVIDIA before deployment.
Where can I download the MSN3700-VS2RO datasheet PDF?
The official datasheet covering the MSN3700-VS2RO is the NVIDIA Spectrum SN3000 Series Switches datasheet PDF, available at nvidia.com under the networking solutions section. Detailed hardware installation and configuration information is in the NVIDIA Spectrum-2 SN3000 1U and 2U Switch Systems Hardware User Manual on docs.nvidia.com, and port/ordering configuration details are on networking-docs.nvidia.com. XAIPART product pages also link directly to the manufacturer datasheet for verified specifications.
Where can I find the MSN3700-VS2RO port layout?
The MSN3700-VS2RO provides 32 QSFP56 ports on the front panel in a 1U chassis; the exact port numbering, management port, console port, and PSU bay layout are illustrated in the NVIDIA Spectrum-2 SN3000 1U and 2U Switch Systems Hardware User Manual on docs.nvidia.com. Note that as this is a complete rack switch system rather than a semiconductor IC, there is no pinout diagram - port mapping, breakout cable guidance, and LED indicators are documented in the hardware manual instead.
What is the lead time for the MSN3700-VS2RO?
Lead time for the MSN3700-VS2RO varies by channel: stocking resellers such as Zones and Router-Switch list the unit as available for purchase, implying near-immediate shipment from stock, while factory-new NVIDIA orders can carry multi-week lead times during 2026 supply constraints - Router-Switch's 2026 alternatives guide specifically notes MSN3700 stock shortages and long lead times. For guaranteed delivery, source from resellers holding stock or consider warrantied refurbished units from BrightStar Systems as of 2026-10-19.
Does the MSN3700-VS2RO support Cumulus Linux and NVIDIA Onyx?
Yes. As an ONIE-based Open Ethernet switch, the MSN3700-VS2RO installs any ONIE-compatible network operating system, including NVIDIA Onyx and Cumulus Linux. The related MSN3700-VS2R SKU is explicitly described as shipping with Cumulus Linux support, and the -VS2R variant with NVIDIA Onyx, confirming both NOS paths on the MSN3700 platform. The onboard x86 CPU provides sufficient compute for either NOS plus telemetry agents. Confirm NOS licensing with NVIDIA or your reseller at time of order.
What are the key specifications of the MSN3700-VS2RO that engineers should know?
The MSN3700-VS2RO is a 200GbE Open Ethernet switch with 32 QSFP56 ports, 12.8 Tbps switching capacity, NVIDIA Spectrum-2 ASIC, 1U standard-depth rack chassis, ONIE boot loader, x86 management CPU, dual redundant AC power supplies, connector-to-power (C2P) airflow, rail kit included, operating range 0 to 40 C, and storage range -40 to 70 C. NVIDIA SKU 920-9N201-00RA-0N0. According to NVIDIA's SN3000 datasheet, the series spans 1GbE to 400GbE port speeds for leaf/spine/super-spine deployments.

Données de référence d'ingénierie pour MSN3700-VS2RO — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the MSN3700-VS2RO when you need 32 ports of up to 200GbE in 1U for spine, super-spine, or high-bandwidth leaf roles, and your rack exhausts air front-to-back (C2P) with dual AC feeds and standard cabinet depth. Choose the MSN3700-VS2FC instead if your rack airflow is port-to-power. Choose the MSN3700-VS2R if your servers are predominantly 25GbE/100GbE and you want 48 SFP28 connections without breakout cables. Choose the short-depth MSN3700-CS2RO only for shallow cabinets. The cross-brand Supermicro SSE-SN3700-VS2RC uses the same Spectrum-2 ASIC but is discontinued - consider it only for budget channel-remainder buys where NVIDIA SKUs face the 2026 lead-time constraints noted by resellers. Budget roughly $29,247 per new unit as of 2026-10-19; warrantied refurbished units lower this substantially.

Comparaison avec les alternatives

Paramètre Ce produit MSN3700-VS2FC MSN3700-VS2R SSE-SN3700-VS2RC
Brand NVIDIA (Mellanox) NVIDIA (Mellanox) NVIDIA (Mellanox) Supermicro
Package / Form Factor 1U rack-mount, standard depth 1U rack-mount, same chassis 1U rack-mount, same chassis family 1U rack-mount
ASIC NVIDIA Spectrum-2 NVIDIA Spectrum-2 NVIDIA Spectrum-2 NVIDIA Spectrum-2
Switching Capacity 12.8 Tbps 12.8 Tbps 12.8 Tbps 12.8 Tbps
Port Configuration 32 x QSFP56 (up to 200G) 32 x QSFP56 48 x SFP28 + 12 x QSFP28 32 x 200G ports
Lifecycle Status Active (channel available, new) Active Active Discontinued (EOL)

Principaux différenciateurs

  • Full 200G per-port density in 32 ports (vs MSN3700-VS2R)
  • Open Ethernet with ONIE freedom (vs SSE-SN3700-VS2RC)
  • Standard-depth chassis (vs MSN3700-CS2RO)

Notes de conception

Connect the two AC power supplies to independent power feeds (A/B feeds from separate PDUs) to achieve true redundancy; with both PSUs on a single feed, a breaker trip takes the switch offline despite dual supplies. Verify rack PDU capacity against the switch's maximum power draw before deployment - the exact wattage figure should be taken from the NVIDIA SN3000 Hardware User Manual. Use the supplied rail kit to support the standard-depth chassis; do not cantilever-mount a 1U switch of this weight on front brackets alone.

The -VS2RO suffix specifies connector-to-power (C2P) airflow: air enters at the QSFP56 port face and exhausts at the PSU face. Install with the port face toward the cold aisle and PSU face toward the hot aisle. Mixing airflow directions in one rack recirculates hot exhaust and can push internal temperatures above the 0 C to +40 C operating specification. If your rack uses reversed airflow, order the -VS2FC (port-to-power) variant instead of retrofitting fans.

Confirm the exact SKU suffix before purchase: MSN3700 variants differ by depth (VS standard vs CS short), airflow, and PSU type, and mismatches are discovered only at rack-install time. Because this is an ONIE Open Ethernet switch, it ships without a network operating system - schedule NOS installation (NVIDIA Onyx, Cumulus Linux, or third-party) and license procurement before the deployment window. QSFP56 optics and DAC/AOC cables must be on the NVIDIA interoperability list for guaranteed 200G link training.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

Compliance data for complete switch systems is declared at system level by NVIDIA; not stated in the retrieved web data. UNSPSC 43222612 (Ethernet switches).

Données vérifiées le : 2026-10-19 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

MSN3700-VS2RO MSN3700-VS2RO datasheet Mellanox MSN3700-VS2RO price NVIDIA Spectrum-2 32x QSFP56 200GbE switch MSN3700-VS2RO vs MSN3700-VS2FC MSN3700-VS2RO drop-in replacement MSN3700-VS2RO vs MSN3700-VS2R which is better 200G leaf spine switch 1U ONIE buy MSN3700-VS2RO in stock lead time Supermicro SSE-SN3700-VS2RC equivalent what is the MSN3700-VS2RO operating temperature NVIDIA SN3700 switch for data center fabric

Composants & termes associés

NVIDIA Mellanox MSN3700-VS2RO MSN3700-VS2FC MSN3700-VS2R MSN3700-CS2RO SSE-SN3700-VS2RC Supermicro Spectrum-2 ASIC SN3000 series Open Ethernet ONIE NVIDIA Onyx Cumulus Linux QSFP56 200GbE 12.8 Tbps leaf-spine topology C2P airflow 1U rack-mount switch Ethernet switch x86 management CPU RoHS UNSPSC 43222612
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ