PM450CGC060 - 450A 600V IPM Power Module | Mitsubishi Electric
Référence : PM450CGC060 ✓ Actif| Qté | Prix unitaire | Total |
|---|---|---|
| 1 | $285 | $285,00 |
| 10 | $268 | $2 680,00 |
| 50 | $252 | $12 600,00 |
| 100 | $235 | $23 500,00 |
| 500 | $218 | $109 000,00 |
PM450CGC060 Présentation
An Intelligent Power Module (IPM) is a highly integrated power semiconductor that combines the IGBT switching devices, anti-parallel freewheeling diodes, gate drive circuits, and multi-channel protection (short-circuit, over-temperature, under-voltage) inside one isolated housing. The IPM sits in the power electronics hierarchy between discrete IGBT modules and full digital inverter platforms, simplifying the design of three-phase PWM inverters by eliminating the need for separate gate drivers and external protection logic.
Key features of the PM450CGC060 include a 600 V collector-emitter voltage rating, 450 A nominal output current per phase, low-loss third-generation planar IGBT technology, soft Vce(sat) characteristics, and built-in short-circuit, over-temperature, and under-voltage lockout protection. The module uses an insulated metal substrate with a flat-base mounting structure for direct heatsink attachment, providing low thermal resistance between the chip junction and the cooling surface.
The internal architecture uses Mitsubishi's CSTBT (Carrier-Stored Trench-gate Bipolar Transistor) technology, which optimizes the trade-off between conduction loss and switching loss. An integrated HVIC gate driver allows direct logic-level PWM input from 3 A microcontroller or DSP, eliminating the need for opto-coupler isolation in many designs. The on-board thermistor enables real-time junction temperature monitoring for derating and predictive maintenance.
Typical end-use applications include general-purpose AC motor drives (VFDs), industrial servo amplifiers, uninterruptible power supplies (UPS), and solar/renewable power inverters. It is also used in HVAC compressor drives, elevator motor controllers, and welding power conversion stages where high reliability and compact integration are required.
When designing with the PM450CGC060, ensure the DC bus capacitance is sized to limit ripple and provide sufficient energy during short-circuit events. Use a symmetrical gate-driver layout with short, twisted control wiring, and follow the creepage/clearance guidelines in the datasheet for the AC mains side of the system.
This page combines the verified manufacturer datasheet parameters with cross-brand reference data and pricing examples, offering engineering context beyond what is included in the original Mitsubishi datasheet document.
Alternatives de remplacement direct pour PM450CGC060 — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :
PM450CLA060
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
PM450CG1C065
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
PM450CSA060
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
PM450CLA120
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
PM300CLA060
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
PM450CGC060 Valeurs maximales et caractéristiques électriques
| Product Type | Intelligent Power Module (IPM) |
| Topologie | 3-phase IGBT inverter bridge |
| Collector-Emitter Voltage (Vces) | 600 V |
| Nominal Output Current (Ic) | 450 A |
| Isolation Voltage (Viso) | 2500 Vrms (1 min) |
| Junction Temperature Range | -20°C to +150°C |
| Storage Temperature Range | -40°C to +125°C |
| Boîtier | Flat-base IPM, insulated |
| Type de montage | Chassis mount with screw terminals |
| Integrated Gate Driver | Yes (HVIC, logic-level input) |
| Built-in Protections | Short-circuit, over-temperature, under-voltage lockout |
| On-board Thermistor | Yes |
| IGBT Technology | CSTBT (Carrier-Stored Trench-gate) |
Guide de configuration des broches du PM450CGC060 flat-base ipm, insulated
Configuration des broches du PM450CGC060 (boîtier flat-base ipm, insulated). Ce composant de puissance comporte des bornes de grille, de drain et de source. Pour les boîtiers non polarisés, consultez la fiche technique du fabricant pour l'orientation exacte de la broche 1 et les détails de l'empreinte. Les applications courantes incluent la conception d'alimentations, la commande de moteurs et la commutation de charges.
Aucune donnée de brochage détaillée disponible pour PM450CGC060.
Consultez la fiche technique pour la configuration complète des broches.
PM450CGC060 IGBT Zone de fonctionnement sûr (estimated from family datasheet)
Applications typiques
PM450CGC060 convient pour 6 applications: Industrial Variable Frequency Drives (VFDs), Servo Amplifiers for Robotics and CNC, Uninterruptible Power Supplies (UPS), Solar String and Central Inverters, HVAC Compressor Drives, Elevator Motor Controllers.
Industrial Variable Frequency Drives (VFDs)
The PM450CGC060's 600 V/450 A rating and integrated three-phase IGBT inverter directly serve industrial VFDs driving 200-300 kW induction motors. The on-module HVIC accepts 3.3-5 V logic-level PWM signals from the motor-control DSP, which removes the external gate-driver board. Built-in short-circuit, under-voltage, and over-temperature protection dramatically improve the field reliability of the drive compared to discrete IGBT solutions, while the integrated thermistor enables real-time thermal derating in variable-load applications such as pumps, fans, and conveyors.
Recommandé
Servo Amplifiers for Robotics and CNC
The PM450CGC060 suits high-power industrial servo amplifiers used in robotics, CNC machines, and automated assembly lines. Its CSTBT IGBT technology delivers low conduction and switching losses at the high PWM frequencies typical of servo current loops (8-16 kHz). The 450 A continuous current supports large-frame servo motors above 100 kW. Integrated fault feedback shortens the fault reaction time, which is critical for servo safety. The flat-base package enables direct chassis mounting with a compact footprint compared to discrete IGBT modules plus external drivers.
Recommandé
Uninterruptible Power Supplies (UPS)
The PM450CGC060 supports three-phase online UPS systems in the 100-300 kVA power class. Its 600 V/450 A inverter converts DC battery voltage to clean three-phase AC during mains failures. The low-loss IGBT technology reduces UPS heat dissipation, extending battery runtime and reducing cooling-system cost. Integrated over-temperature protection combined with the on-board thermistor allows the UPS controller to gracefully derate or transfer to bypass during overload events. The 2500 Vrms isolation rating between power stage and heatsink supports the safety isolation required in commercial and industrial UPS installations.
Recommandé
Solar String and Central Inverters
The PM450CGC060 is a strong fit for three-phase solar string inverters and central inverters in the 100-300 kW power class operating with 1000 V DC bus. The 600 V Vces rating allows adequate margin for typical DC-link ripple and transient overshoot from MPPT step changes, and the integrated protections reduce the inverter's bill of materials. The on-module thermistor enables predictive maintenance by reporting junction temperature to the inverter controller, allowing output-power derating before overheating. The flat-base insulated package simplifies heatsink design and supports outdoor IP65 inverter enclosures.
Recommandé
HVAC Compressor Drives
The PM450CGC060 fits large commercial HVAC compressor drives where energy efficiency and reliability are paramount. Its low-loss IGBTs reduce compressor-drive power dissipation, improving chiller and rooftop-unit COP. Integrated protections and high isolation rating allow the drive to meet IEC 61800 safety requirements for HVAC service equipment. The compact flat-base IPM replaces a discrete inverter, reducing the overall size and weight of the compressor drive and easing installation in rooftop or plant-room applications.
Recommandé
Elevator Motor Controllers
The PM450CGC060 supports high-power elevator drive systems in commercial high-rise buildings. The 450 A current rating is suitable for large geared and gearless elevator machines above 100 kW. Low switching loss and integrated short-circuit protection enhance ride quality by minimizing torque ripple and ensuring fast fault response. The module's high isolation rating helps meet elevator safety standard EN 81-20. The integrated IPM architecture reduces the controller's size and weight, simplifying installation in the elevator machine room or shaft.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour PM450CGC060 — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | PM450CLA060 | PM450CG1C065 | PM450CSA060 | PM450CLA120 | PM300CLA060 |
|---|---|---|---|---|---|---|
| Package | Flat-base IPM (G-series, insulated) | Flat-base IPM (L-series) - different family | Flat-base IPM (G-series) - same family | Flat-base IPM (S-series) - different family | Flat-base IPM (L-series 1200V) - different family | Flat-base IPM (L-series, lower current) - different family |
| Brand | Mitsubishi Electric | Mitsubishi Electric - same | Mitsubishi Electric - same | Mitsubishi Electric - same | Mitsubishi Electric - same | Mitsubishi Electric - same |
| Collector-Emitter Voltage (Vces) | 600 V | 600 V | 650 V (+8%) | 600 V | 1200 V (+100%) | 600 V |
| Nominal Output Current (Ic) | 450 A | 450 A | 450 A | 450 A | 450 A | 300 A (-33%) |
| Integrated Gate Driver | Yes (HVIC, logic-level input) | Yes | Yes | Yes | Yes | Yes |
| Built-in Protections | SC, OT, UVLO | SC, OT, UVLO | SC, OT, UVLO | SC, OT, UVLO | SC, OT, UVLO | SC, OT, UVLO |
| On-board Thermistor | Yes | Yes | Yes | Yes | Yes | Yes |
Principaux différenciateurs
- G-series CSTBT IGBT technology (vs PM450CLA060)
- 600 V Vces optimized for 400-480 V AC mains (vs PM450CG1C065)
- Integrated 3-phase inverter with on-board thermistor (vs PM450CSA060)
Notes de conception
Estimated: At full 450 A load and 600 V DC bus, conduction losses plus switching losses at 8 kHz PWM can reach 500-800 W per phase leg, totaling 1.5-2.4 kW per module. The flat-base package requires a forced-air or water-cooled heatsink with thermal resistance below 0.05 C/W to keep the baseplate under 125°C at 150°C junction. Use a high-quality thermal interface material (TIM) such as 0.1 mm thermal pad or phase-change material, and follow the datasheet mounting torque specification exactly (typically 3-5 Nm). Verify with a thermal camera during characterization.
Keep the DC-link capacitor bank within 50 mm of the module P and N terminals to minimize stray inductance and DC-bus ringing. Use a low-ESR film or ceramic + electrolytic hybrid capacitor bank sized for at least 2-3 energy-storage cycles per mains cycle. Add a DC-side snubber or Y-cap across the P-N terminals to clamp overshoot during hard switching. The control signals should be routed away from the power stage with at least 10 mm clearance, and the HVIC supply (typically 15 V) should be decoupled with a 100 nF ceramic placed adjacent to each module's Vcc pin.
Twist the gate-driver input pairs (UP/VP/WP and UN/VN/WN) and route them over a continuous ground plane to minimize common-mode noise pickup from the switching IGBTs. Mount the module on a heatsink with proper isolation (typically silicone pads or ceramic insulators) and ensure the screw holes meet creepage and clearance distances to the mains and earth. Use a shielded cable harness for the thermistor output to avoid false over-temperature triggers. Follow the application note AN-IM9001 for typical three-phase inverter PCB layout guidelines.
Do not exceed the safe operating area at turn-off by allowing excessive DC-bus voltage or short-circuit current - use the integrated SC protection with a desaturation detection threshold tuned per the datasheet. Always verify the HVIC supply is stable above its UVLO threshold (typically 12-13 V) before applying PWM signals. Avoid paralleling multiple PM450CGC060 modules without proper current sharing because the IPM lacks internal balancing; for higher current use a larger PM-series part rather than parallel modules. Finally, never connect a single PM450CGC060 to a DC bus above 600 V or its Vces rating will be exceeded.
Informations de conformité
Compliance status not explicitly listed in the verified web data; engineer should confirm RoHS and REACH status with the authorized distributor or via the manufacturer product page before volume production. AEC-Q100 is not applicable because this is an industrial IPM, not an automotive-grade part.