Skyworks Solutions

SI2457-D-GT - 56 kbps ISOMODEM | Skyworks Solutions

Référence : SI2457-D-GT ✓ Actif
3.3 V Vdss Type I and Type II decode Id 24-pin TSSOP Package 32.768 kHz Speed No external ROM or RAM required Memory
MOQ : 1 |

SI2457-D-GT Présentation

Skyworks Solutions Inc. SI2457-D-GT is a 56 kbps system-side ISOMODEM data-communication IC operating from a 3.3 V supply and housed in a 24-pin TSSOP package. It supports ITU-T and Bell modem formats including V.21, V.22, V.23, V.32, V.34, V.90, Bell 103, and Bell 212A, with additional V.42, V.42bis, V.44, MNP2-5, and caller-ID functions documented for the Si2457/34/15/04 family.

An ISOMODEM is a semiconductor implementation of a modem's modulation, demodulation, and protocol functions. It belongs to the modem IC hierarchy, integrates data-link signaling with a host-facing controller interface, and is commonly positioned between a host processor and a telephone or data-network interface. Its primary design purpose is to reproduce standardized modem signaling without requiring a discrete modem subsystem.

The SI2457-D-GT supports data rates from Bell 300 bps through 56 kbps, automatic rate negotiation, Type I and Type II caller-ID decoding, and parallel, UART, or SPI host interfaces. Its on-chip program ROM provides the firmware for the documented features, while program RAM permits minor firmware changes. Flexible clocking includes a low-cost 32.768 kHz oscillator option and a 4.915 MHz clock option.

The device includes global capacitive isolation rated at more than 6,000 V and parallel phone detection. These characteristics allow the modem circuitry to interface with a telephone line while maintaining separation between line-side and logic-side functions. The SI2457 family is intended for interoperable data communications where V-series protocols, caller identification, and a compact controller implementation are required.

Typical uses include embedded modems, fax equipment, data terminals, industrial communication equipment, and telephone-line data products. Designers should select the interface mode and clock arrangement that match the host controller and line interface, and should use the manufacturer pin-description table when assigning PCB nets.

A key design consideration is that a shared 24-pin TSSOP footprint does not by itself guarantee firmware-level interchangeability. Review the protocol list, clock requirements, interface selection, isolation implementation, and exact orderable suffix before treating another device as a replacement.

This page combines the manufacturer's Revision D family datasheet, distributor identification, supported protocol details, package information, and practical replacement criteria to support component selection, PCB planning, and sourcing.

Alternatives de remplacement direct pour SI2457-D-GT — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

SI2457-C-GTR

✅ Remplacement direct
📦 24-pin TSSOP
Same 24-pin TSSOP footprint and 56 kbps maximum data rate, with 0 additional pins and 0 kbps headline data-rate difference; revision-specific firmware must be verified.

📋 Alternative de référence (hors catalogue)

SI2457-C-GT

✅ Remplacement direct
Silicon Laboratories
📦 24-pin TSSOP
ISOmodem system-side codec IC · 56 kbps · 3.3 V · 3.0 V to 3.6 V · 0 C to 70 C · 24-pin TSSOP, 0.173 in (4.40 mm) width · Surface mount · Tube

Contactez-nous pour le prix

Voir la fiche technique →

SI2457-D-GT Spécifications

Device Type 56 kbps system-side ISOMODEM
Tension d'alimentation 3.3 V
Maximum Data Rate 56 kbps
Minimum Modem Data Rate 300 bps
Supported ITU-T Formats V.21, V.22, V.23, V.32, V.34, V.90
Supported Bell Formats Bell 103, Bell 212A
Additional Protocol Support V.42, V.42bis, V.44, Fast Connect, MNP2-5
Caller ID Support Type I and Type II decode
Host Interface Options UART, SPI, or parallel
External Memory Requirement No external ROM or RAM required
Program Memory On-chip program ROM and program RAM
Low-Speed Clock Option 32.768 kHz
High-Speed Clock Option 4.915 MHz
Capacitive Isolation Over 6000 V
Telephone Line Detection Parallel phone detect
Boîtier 24-pin TSSOP
Package Type Gull-wing TSSOP
Terminal Count 24
Plage de température de fonctionnement 0 C to 70 C
Type de montage Surface mount
Statut RoHS Compliant

Guide de configuration des broches du SI2457-D-GT gull-wing tssop

Configuration des broches du SI2457-D-GT (boîtier gull-wing tssop). La numérotation des broches, les fonctions et les schémas de connexion sont définis dans la fiche technique du fabricant. Consultez-la pour l'empreinte exacte et les directives de soudage.

Schéma de brochage du boîtier gull-wing tssop pour le SI2457-D-GT

Aucune donnée de brochage détaillée disponible pour SI2457-D-GT.

Consultez la fiche technique pour la configuration complète des broches.

Applications typiques

SI2457-D-GT convient pour 6 applications: Embedded 56 kbps Data Modem, Caller-ID Telephone Equipment, Industrial Data Terminal, Legacy Fax and Data Endpoint, Automated Rate-Negotiation System, Telephone-Line Network Interface.

🌐

Embedded 56 kbps Data Modem

The SI2457-D-GT fits embedded modem designs requiring a complete 56 kbps V-series signaling engine in a 24-pin TSSOP. Its support for V.21, V.22, V.23, V.32, V.34 and V.90, together with Bell 103 and Bell 212A formats, allows a host processor to communicate over legacy telephone or data-service lines. On-chip program ROM and RAM reduce external memory requirements, while UART, SPI, and parallel interfaces provide design flexibility. The designer must confirm the required protocol set, clock source, and host firmware against Revision D before production release.

📱

Caller-ID Telephone Equipment

Type I and Type II caller-ID decoding make the SI2457-D-GT suitable for telephone equipment that receives and forwards caller information to an embedded controller. Its modem formats extend from Bell 300 bps through 56 kbps, enabling the same device to support signaling and caller-ID handling within a compact design. A 3.3 V supply and 24-pin TSSOP package simplify integration into telephone terminals and multifunction communications products. The host software must correctly transfer decoded identifiers, and the line-side network must satisfy the isolation and telephone-interface requirements described by the manufacturer.

🏭

Industrial Data Terminal

The SI2457-D-GT can serve as the modem engine in an industrial data terminal designed around legacy switched-network or telephone-line connectivity. Its 56 kbps maximum rate, automatic rate negotiation, and support for V.42bis error correction and MNP2-5 provide a practical protocol combination for reliable compressed data transfer. The 0 C to 70 C operating range is suitable for many commercial and industrial enclosure environments, although it does not establish automotive or extreme-environment qualification. Select the host interface and clock arrangement according to the controller platform and validate line coupling, isolation, and restart behavior.

🖥️

Legacy Fax and Data Endpoint

Legacy fax and data endpoints can use the SI2457-D-GT when the equipment still requires V-series modem interoperability rather than an all-digital communications interface. Support for V.21, V.22, V.23, V.32, V.34 and V.90 provides several signaling rates, while V.42, V.42bis and Fast Connect options improve compatibility with contemporary modem negotiation procedures. The 24-pin TSSOP package supports compact terminal construction, and the device requires no external ROM or RAM. The equipment designer should verify the exact V.29 configuration and any application-specific timing required by the target fax or data protocol.

🔧

Automated Rate-Negotiation System

MNP2-5 automatic rate negotiation allows the SI2457-D-GT to work in systems where the connected modem must establish a supported rate during call setup. This is useful for unattended data equipment that must operate across variable line conditions and negotiate with remote V-series equipment. The IC combines modem signaling and protocol support in one 24-pin TSSOP, while flexible 32.768 kHz and 4.915 MHz clock options help match different circuit arrangements. Firmware, clock selection, and line-network calibration must be validated together to obtain reliable negotiation and throughput across supported connection types.

🌐

Telephone-Line Network Interface

The SI2457-D-GT is appropriate for a telephone-line interface requiring modem modulation, demodulation, and protocol handling close to the host controller. Its global capacitive isolation rated at more than 6,000 V and parallel phone detection help structure a line-facing design that remains separated from logic circuitry. The 3.3 V device provides UART, SPI, or parallel connectivity to the system controller, and the on-chip program memory removes external ROM or RAM from the modem subsystem. Engineers should follow the manufacturer network recommendations closely because isolation voltage alone does not validate the complete telephone-interface safety or regulatory performance.

Récapitulatif des produits recommandés

SI2457-C-GTR Pin-compatible Si2457-family replacement candidate Utilisé dans : Embedded 56 kbps Data Modem, Caller-ID Telephone Equipment, Industrial Data Terminal, Legacy Fax and Data Endpoint, Automated Rate-Negotiation System, Telephone-Line Network Interface SI2457-C-GT Same-family Si2457 modem option Utilisé dans : Embedded 56 kbps Data Modem, Caller-ID Telephone Equipment, Industrial Data Terminal, Legacy Fax and Data Endpoint, Automated Rate-Negotiation System, Telephone-Line Network Interface
What is the SI2457-D-GT?
The SI2457-D-GT is a 56 kbps system-side ISOMODEM from Skyworks Solutions Inc. for data-modem and telephone-line communications. According to the Skyworks Solutions datasheet for Si2457/34/15/04 Revision D, it supports ITU-T V.21, V.22, V.23, V.32, V.34 and V.90 signaling together with Bell 103 and Bell 212A formats. The device also provides V.42, V.42bis, V.44, automatic rate negotiation, and caller-ID decoding in a 24-pin TSSOP package.
What are the key specifications of SI2457-D-GT that engineers should know?
The SI2457-D-GT operates from 3.3 V and supports modem signaling from Bell 300 bps through 56 kbps. The Skyworks Solutions family datasheet identifies UART, SPI, and parallel host interfaces, on-chip program ROM and RAM, no requirement for external ROM or RAM, and flexible clock options of 32.768 kHz or 4.915 MHz. The 24-pin TSSOP device also includes Type I and Type II caller-ID decoding and capacitive isolation rated at more than 6,000 V.
What modem protocols does SI2457-D-GT support?
The SI2457-D-GT supports ITU-T V.21, V.22, V.23, V.32, V.34 and V.90, plus Bell 103 and Bell 212A formats. The manufacturer's Revision D datasheet also identifies V.42, V.42bis, V.44, Fast Connect, and MNP2-5 automatic rate negotiation for the Si2457/34/15/04 family. Protocol availability should be checked against the exact ordering code and the firmware configuration required by the host equipment.
Where can I download the SI2457-D-GT datasheet PDF?
The official SI2457-D-GT family datasheet is available from Skyworks Solutions at https://www.skyworksinc.com/-/media/Skyworks/SL/documents/public/data-sheets/Si2457-34-15-04D.pdf. It covers the Si2457, Si2435, Si2415 and Si2404 devices and includes the protocol, clock, interface, isolation, and package information needed for design review. Use the pin-description table in that document when assigning PCB signals.
Where can I find the SI2457-D-GT pinout?
The SI2457-D-GT pinout is documented in the pin-description table of the Skyworks Solutions Si2457/34/15/04 Revision D datasheet. The exact orderable device uses a 24-pin TSSOP package, and the diagram must be interpreted according to the package's standard pin numbering. Before routing a board, check every power, ground, clock, host-interface, telephone-line, and isolation-related connection against that table rather than inferring names from a generic modem schematic.
What interface options are available on the SI2457-D-GT?
The SI2457-D-GT can communicate with a host controller through UART, SPI, or a parallel interface. According to the Skyworks Solutions Si2457/34/15/04 Revision D datasheet, the flexible interface choice supports integration into different embedded modem, data-terminal, and telephone equipment architectures. Firmware configuration and board-level signal requirements must match the selected interface mode, so the complete interface options should be confirmed for the exact product variant during schematic review.
Is the SI2457-D-GT suitable for caller-ID applications?
The SI2457-D-GT supports Type I and Type II caller-ID decoding, making it suitable for equipment that receives caller information over a modem line. This capability is identified in the Skyworks Solutions Si2457/34/15/04 Revision D family datasheet. The line interface, protocol settings, and host software must still be designed to pass decoded information correctly, and the exact electrical isolation and telephone-line requirements should be checked in the manufacturer's application information.
What clock options can the SI2457-D-GT use?
The SI2457-D-GT supports a low-cost 32.768 kHz clock option and a 4.915 MHz clock option. These flexible clock choices are documented for the Si2457/34/15/04 family in the Skyworks Solutions datasheet. Select the timing source according to the required modem rate, external component arrangement, and firmware configuration, then validate startup and communication timing on the assembled board rather than treating either frequency as interchangeable without review.
SI2457-D-GT vs SI2457-C-GTR - which is better for a new design?
The SI2457-C-GTR is the better-supported drop-in choice when its published protocol, clock, and firmware characteristics meet the system requirements. A component comparison identifies the SI2457-C-GTR as functionally and terminally compatible with the SI2457-D-GT while both use a 24-pin TSSOP package. Their maximum 56 kbps data rate is unchanged, but a new design should still verify revision-specific features against the manufacturer documentation before releasing production hardware.
What is the difference between SI2457-D-GT and SI2457-C-GT?
The primary verified difference between the SI2457-D-GT and SI2457-C-GT is the ordering suffix, while both are listed as 56 kbps modems using a 24-pin TSSOP package. A published comparison describes the SI2457-C-GTR as a direct replacement with consistent terminals and package characteristics. Revision-specific firmware details should still be checked because the available product records do not quantify every internal register or timing difference.
When should I choose SI2457-D-GT instead of another SI2457-family device?
Choose the SI2457-D-GT when its Revision D device documentation matches the required V-series protocols, caller-ID functions, clock configuration, and host interface. It is appropriate for a 3.3 V, 56 kbps system-side modem design using a 24-pin TSSOP footprint. Select another SI2457-family orderable code only after checking revision changes, firmware behavior, package suffix, and qualification needs; package similarity alone does not establish complete interchangeability.
Is SI2457-D-GT suitable for industrial communication equipment?
The SI2457-D-GT can suit industrial communication equipment that specifically requires a legacy modem signal rather than a modern Ethernet interface. Its supported data rates span Bell 300 bps through 56 kbps, while the 0 C to 70 C operating range supports commercial and extended-temperature equipment designs. The product is not described as AEC-Q100 qualified, so it should not be selected automatically for automotive installations or other harsh environments without separate qualification.
What can replace SI2457-D-GT?
The SI2457-C-GTR is a documented replacement candidate because a published comparison states that its terminals and packages are consistent and its principal modem functions match the SI2457-D-GT. Both devices support a maximum data rate of 56 kbps and use a 24-pin TSSOP package. Before substitution, confirm the required V.21 through V.90 modes, caller-ID behavior, clock source, host interface, isolation network, and revision-specific firmware against the manufacturer documentation.
Is SI2457-C-GTR the same as SI2457-D-GT?
The SI2457-C-GTR is a pin-and-package-compatible replacement candidate for the SI2457-D-GT, with the same 24-pin TSSOP format and 56 kbps maximum data rate. However, matching package and headline data rate do not make the devices fully identical in every internal behavior. The ordering revision, supported protocol set, clock configuration, caller-ID implementation, and firmware requirements should be confirmed before marking the parts as interchangeable in a production bill of materials.
Where can I buy SI2457-D-GT and what is its lead time?
Use the Request a Quote form on this page to request current SI2457-D-GT availability, lead time, and order confirmation. The part is identified in current distributor records as SI2457-D-GT from Skyworks Solutions Inc. in a 24-pin TSSOP package. XAIPART does not publish a static price or guaranteed delivery schedule in the product narrative because both change with quantity, inventory, and sourcing conditions.
Is SI2457-D-GT in stock and what does it cost?
Current stock and transaction pricing for the SI2457-D-GT should be confirmed through the Request a Quote form on this page. The 56 kbps, 3.3 V modem is listed by Skyworks Solutions Inc. in a 24-pin TSSOP package, but neither a confirmed stock quantity nor a current unit price can be established from the available product records. Request the exact suffix, tube quantity, and required production volume with the quote.

Données de référence d'ingénierie pour SI2457-D-GT — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the SI2457-D-GT for a 3.3 V, 56 kbps modem design that uses the 24-pin TSSOP footprint and requires the documented V-series formats, caller-ID decoding, flexible host interface, and on-chip program memory. Consider the SI2457-C-GTR when a published pin- and package-compatible replacement path is useful, but verify revision-specific firmware, protocol availability, clocking, and line-interface behavior before production use. The SI2457-C-GT is another same-package candidate with the same 56 kbps headline rate, although its detailed electrical and firmware differences are not fully quantified in the available records. For any substitution, prioritize the complete protocol list, host interface, clock configuration, isolation implementation, and package suffix over package identity alone.

Comparaison avec les alternatives

Paramètre Ce produit SI2457-C-GTR SI2457-C-GT
Package 24-pin TSSOP 24-pin TSSOP 24-pin TSSOP
Brand Skyworks Solutions Inc. Silicon Laboratories Silicon Laboratories
Maximum Data Rate 56 kbps 56 kbps 56 kbps
Supported Modem Formats ITU-T V.21, V.22, V.23, V.32, V.34, V.90; Bell 103, Bell 212A V.21, V.22, V.23, V.32, V.34, V.90, Bell 103, Bell 212A V.21, V.22, V.23, V.32, V.34, V.90, Bell 103, Bell 212A

Principaux différenciateurs

  • Maintains the same 56 kbps headline data rate as the documented replacements (vs SI2457-C-GTR)
  • Provides a 24-pin TSSOP replacement path without changing the package (vs SI2457-C-GT)
  • Revision D family documentation identifies MNP2-5 and V.42bis support (vs SI2457-C-GT)

Notes de conception

Assign every net from the manufacturer pin-description table before layout begins, particularly the telephone-line, capacitive-isolation, clock, and host-interface signals. The 24-pin TSSOP footprint leaves limited escape space around the device, so place the isolation and line-network components away from the host connector while preserving the shortest practical isolation path. Do not infer pin functions from a generic 16-pin modem symbol because the SI2457-D-GT is identified as a 24-pin TSSOP device.

Decouple the 3.3 V modem supply locally and keep return-current paths short. Place the input capacitor and additional high-frequency bypass capacitor close to their corresponding supply pins, with a continuous ground reference beneath the device where the package and board construction permit. The listed specification establishes the 3.3 V operating supply but does not provide a recommended capacitance value, so use the values and layout guidance in the manufacturer datasheet and reference materials rather than estimating them from another modem.

Confirm the clock configuration before committing the printed circuit board because the family supports 32.768 kHz and 4.915 MHz options. Also verify whether the selected firmware expects UART, SPI, or parallel control signals. A replacement that retains the 24-pin package and 56 kbps headline rate can still require different initialization or timing. Review the exact orderable revision, supported V-series modes, caller-ID behavior, and program-memory behavior as a single compatibility checklist.

Keep the modem clock and host-interface traces away from the telephone-line network where practical, and preserve the manufacturer's isolation arrangement between line-side and logic-side circuitry. More than 6,000 V of capacitive isolation is a device capability rather than proof that the finished interface meets applicable product-safety requirements. Review creepage, clearance, surge exposure, grounding, and shield strategy for the target installation because those system-level constraints are not fixed by the IC package alone.

Informations de conformité

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

RoHS compliance is stated in component records. The device is an interface modem IC rather than an automotive-qualified component, and no additional compliance claims are included.

Données vérifiées le : 2026-11-08 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

SI2457-D-GT datasheet SI2457-D-GT pinout SI2457-D-GT datasheet pdf SI2457-D-GT equivalent SI2457-D-GT replacement SI2457-D-GT vs SI2457-C-GTR SI2457-D-GT footprint Skyworks Solutions SI2457-D-GT SI2457-D-GT 24 TSSOP pinout SI2457-D-GT 56 kbps modem SI2457-D-GT caller ID SI2457-D-GT price SI2457-D-GT stock SI2457-D-GT UART SPI parallel SI2457-D-GT clock options

Composants & termes associés

Skyworks Solutions Inc. SI2457-D-GT SI2457-C-GTR SI2457-C-GT ISOMODEM system-side modem modem IC interface IC semiconductor ITU-T V.21 ITU-T V.22 ITU-T V.32 ITU-T V.34 ITU-T V.90 Bell 103 Bell 212A V.42bis MNP2-5 caller ID UART SPI parallel interface 32.768 kHz oscillator 4.915 MHz clock 24-pin TSSOP TSSOP family surface mount capacitive isolation RoHS
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4