TCAN330GDCNR - 3.3V CAN FD Transceiver | Texas Instruments
Référence : TCAN330GDCNR ✓ ActifTCAN330GDCNR Présentation
A CAN transceiver is an interface IC that converts logic-level TXD and RXD signals into differential CAN bus signals, while receiving bus data and converting it back into a digital signal. CAN FD extends the classical CAN data rate and payload capability, making the TCAN330GDCNR appropriate for gateway modules, body controllers, sensor nodes, industrial automation equipment, and connected vehicle systems.
The TCAN330GDCNR is identified as an ultra-low-power device with shutdown and standby modes, helping reduce current consumption in battery-powered or intermittently connected equipment. Its 3.3-V operation can simplify connections to low-voltage microcontrollers, sensors, and digital logic. The manufacturer product information also identifies the family as CAN transceivers with CAN FD support and lists the device in the SOT-23-8 package configuration.
The transceiver’s principal design consideration is integration with the physical CAN bus. The bus side requires correct termination, common-mode handling, protection, and PCB layout that minimizes loop area and preserves signal integrity. The logic side must observe the voltage levels and timing required by the host controller, particularly during standby, shutdown, bus-fault, and recessive-bit conditions.
TCAN330GDCNR is appropriate for applications where board area matters. Its 8-pin SOT-23 package is smaller than many larger CAN transceiver packages, allowing placement near the bus connector or chassis entry point. Designers should compare the complete family datasheet, including bus fault behavior, recessive output behavior, ESD protection, loop delay, and supply current, before finalizing a mixed-voltage or safety-related design.
This product page organizes the key electrical characteristics, package information, drop-in alternatives, and application guidance for engineers evaluating the TCAN330GDCNR. It also distinguishes confirmed manufacturer information from parameters that require review in the device datasheet, helping support faster component selection without obscuring the design limits that matter on a CAN network.
Alternatives de remplacement direct pour TCAN330GDCNR — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Aucune alternative de remplacement direct disponible pour ce produit.
Demander des alternativesTCAN330GDCNR Spécifications
| Product Type | 3.3-V CAN FD transceiver |
| CAN FD Support | Yes |
| Tension d'alimentation | 3.3 V |
| Transceiver Mode | Half-duplex CAN |
| Boîtier | 8-pin SOT-23-8 (DCN) |
| Plage de température de fonctionnement | -40°C to +125°C |
| Nombre de broches | 8 pins |
| Type de montage | Surface mount |
| Shutdown Mode | Supported |
| Standby Mode | Supported |
| Low-Power Feature | Ultra-low-power operation |
| Bus Interface | CAN bus |
| Data Interface | TXD and RXD logic interfaces |
Guide de configuration des broches du TCAN330GDCNR 8-pin sot-23-8 (dcn)
Configuration des broches du TCAN330GDCNR (boîtier 8-pin sot-23-8 (dcn)). La numérotation des broches, les fonctions et les schémas de connexion sont définis dans la fiche technique du fabricant. Consultez-la pour l'empreinte exacte et les directives de soudage.
Aucune donnée de brochage détaillée disponible pour TCAN330GDCNR.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
TCAN330GDCNR convient pour 6 applications: 3.3-V CAN FD Gateway, Automotive Body Control Module, Industrial Sensor Node, Battery-Powered CAN Endpoint, CAN FD Communication Hub, Robotics Control Network.
3.3-V CAN FD Gateway
The TCAN330GDCNR fits a 3.3-V CAN FD gateway where the host controller requires a compact physical-layer interface to a higher-speed CAN bus. Its 8-pin SOT-23-8 package can be placed close to the board edge, while shutdown and standby support can reduce consumption when the gateway is not actively communicating. The system designer must verify the complete timing, common-mode, protection, and bus-fault specifications in the manufacturer datasheet before enabling operation.
Recommandé
Automotive Body Control Module
The TCAN330GDCNR can support a compact CAN FD connection in a body-control or sensor-hub module operating from a 3.3-V rail. Its SOT-23-8 footprint helps preserve board space around dense vehicle electronics, and its -40°C to +125°C operating range covers many industrial vehicle environments. For a production vehicle design, confirm AEC-Q100 status, transient immunity, EMC behavior, and bus-fault handling against the complete manufacturer documentation.
Recommandé
Industrial Sensor Node
For an industrial sensor node connected to a CAN FD backbone, the TCAN330GDCNR provides a space-efficient 3.3-V interface between a microcontroller and the differential bus. Standby and shutdown modes are useful for nodes that spend substantial time idle or operate intermittently. Engineer the bus connector with suitable surge and ESD protection, maintain controlled CAN trace geometry, and verify that the transceiver’s operating limits match the field environment and selected CAN FD data rate.
Recommandé
Battery-Powered CAN Endpoint
The TCAN330GDCNR is suitable for consideration in battery-powered CAN endpoints because its 3.3-V interface and shutdown and standby modes support low-power system architectures. A node designer should use the modes to minimize current while retaining the required bus-recessive behavior and wake-up function. The precise power budget, quiescent current, and state-transition timing must be taken from the official datasheet and verified at system level with the selected regulator and bus load.
Recommandé
CAN FD Communication Hub
In a communication hub, the TCAN330GDCNR can provide the physical-layer connection between a 3.3-V host controller and an external CAN FD network. Its compact 8-pin SOT-23-8 package allows placement near connector or routing structures where board space is constrained. Designers should preserve differential routing symmetry, implement the correct bus termination, provide surge protection, and review loop-delay limits when the hub also performs real-time protocol processing.
Recommandé
Robotics Control Network
A robot controller can use the TCAN330GDCNR to connect a 3.3-V processor or motion controller to a CAN FD network carrying position, status, and diagnostic data. The compact package leaves more PCB area for sensing and power circuitry, while standby and shutdown help manage inactive intervals. The design should account for motor-generated electrical noise, connector grounding, bus termination, and the transceiver’s specified common-mode and fault limits.
Recommandé
Données de référence d'ingénierie pour TCAN330GDCNR — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Notes de conception
Place the TCAN330GDCNR close to the CAN connector or board entry point and route CANH and CANL as a closely coupled differential pair. Keep the traces short, avoid unnecessary stubs, use continuous reference planes where appropriate, and apply the termination arrangement required by the network topology. A compact transceiver package reduces placement distance but does not compensate for poor bus routing.
Decouple the 3.3-V supply locally with the capacitance and layout recommended in the manufacturer datasheet. Place the low-ESR capacitor adjacent to the device supply and ground pins, and keep return-current paths short. Because shutdown and standby behavior affects system power consumption, confirm the relevant state currents and bus-recessive requirements rather than estimating the node budget from nominal operating current alone.
Do not assume that every related TCAN330 ordering code is a PCB drop-in. The DCN suffix identifies the SOT-23-8 package for TCAN330GDCNR, while other suffix codes may use a larger package. Confirm the package drawing, pin table, supply limits, CAN FD timing, standby logic, and shutdown behavior before substituting a part or reusing an existing footprint.
Protect the external CAN interface with protection components selected for the installation’s surge and ESD environment. The available comparison lists ±12 kV for TCAN330GDCNR, but the test method must be confirmed before applying that value to a system-level design. Keep protection return paths controlled, avoid placing long unprotected traces outside the enclosure, and validate conducted and radiated emissions in the finished equipment.
Informations de conformité
The verified manufacturer and distributor excerpts do not explicitly state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status. These fields remain unknown pending review of the manufacturer product documentation.