Analog Devices

AD9060KE - 10-Bit 75 MSPS ECL ADC | Analog Devices

MPN: AD9060KE ✓ सक्रिय
न्यूनतम ऑर्डर मात्रा: 1 |

AD9060KE अवलोकन

The Analog Devices AD9060KE is a monolithic 10-bit flash analog-to-digital converter capable of 75 MSPS word rates, with a bipolar 1.75 V analog input and ECL outputs. The device uses 512 input comparators instead of the 1024 comparators used in a traditional 10-bit flash architecture. Its specified signal-to-noise ratio is 57 dB at a 2.3 MHz input, and the analog input capacitance is 45 pF.

A flash ADC is a parallel-sampling data converter that compares the analog input against multiple reference thresholds during each conversion cycle. The flash architecture belongs to the ADC hierarchy and uses a semiconductor array, precision resistor network, comparators, and digital decoding logic to produce a multi-bit output. The AD9060KE occupies the high-speed ADC segment used where waveform acquisition, instrumentation, medical imaging, communications, and digital oscilloscope performance matter more than low power or minimal cost.

Key characteristics include 10-bit resolution, operation at 75 MSPS and above, ECL-compatible digital outputs, and a low 45 pF analog input capacitance. The 512-comparator architecture can support high sampling throughput with parallel digital output timing. Analog Devices states that dynamic performance is fully characterized and production tested at +25°C, making temperature behavior an important qualification item when the converter is used outside that condition.

The converter also offers versions compliant with MIL-STD-883, according to the Analog Devices product page. This makes it suitable for programs requiring controlled production testing or military-qualified variants, but MIL-STD-883 availability does not mean that every commercial order code is automatically qualified. The ECL interface, analog input arrangement, reference requirements, and package details must be matched carefully when replacing or redesigning around this converter.

Typical applications include digital oscilloscopes, medical imaging equipment, professional signal-processing systems, communications receivers, and test and measurement instruments. These systems benefit from the 75 MSPS conversion rate, 10-bit amplitude resolution, 57 dB SNR, and low 45 pF input capacitance. In high-speed front ends, the converter can capture repetitive or transient waveforms while its parallel output transfers sampled data into digital logic.

The primary design consideration is interface timing. ECL output levels, supply requirements, clocking topology, analog input biasing, reference implementation, and input routing must follow the manufacturer datasheet. Keep the analog input path short and controlled, use the specified power and decoupling arrangement, and validate output timing against the receiving logic before treating the converter as interchangeable with another ADC.

This page organizes the known AD9060KE characteristics into an engineer-oriented selection guide, including sampling performance, interface considerations, application guidance, verified-source links, and a conservative assessment of drop-in replacement options.

के लिए ड्रॉप-इन विकल्प AD9060KE — समान पैकेज, पिन-टू-पिन संगत। PCB रीवर्क आवश्यक करने वाले भिन्न-पैकेज पार्ट्स शामिल नहीं हैं।

AD9060/883B

✅ ड्रॉप-इन ⚠️ विनिर्देश असत्यापित
📦 Ceramic DIP-28
MIL-STD-883-compliant version versus the standard configuration; sampling rate remains 75 MSPS and resolution remains 10 bit

📋 संदर्भ विकल्प (कैटलॉग में नहीं)

AD9060-65

✅ ड्रॉप-इन ⚠️ विनिर्देश असत्यापित
📦 Ceramic DIP-28
65 MSPS word rate versus 75 MSPS, approximately 13% lower; resolution and ECL interface remain equivalent

📋 संदर्भ विकल्प (कैटलॉग में नहीं)

AD9060-100

✅ ड्रॉप-इन ⚠️ विनिर्देश असत्यापित
📦 Ceramic DIP-28
100 MSPS word rate versus 75 MSPS, approximately 33% higher; resolution remains 10 bit

📋 संदर्भ विकल्प (कैटलॉग में नहीं)

AD9060KE Maximum Ratings और Electrical Characteristics

रेज़ोल्यूशन 10 bit
Maximum Sampling Rate 75 MSPS
Supported Word Rates 75 MSPS and above
ADC Architecture 1 monolithic flash converter
Input Comparator Count 512 comparators
Analog Input Type 1 bipolar input
Analog Input Range 1.75 V
Signal-to-Noise Ratio 57 dB at 2.3 MHz
इनपुट कैपेसिटेंस 45 pF
Digital Output Type 1 ECL output interface
Dynamic Performance Test Temperature +25 C
Military Availability 1 MIL-STD-883-compliant version
Production Test Method 1 dynamic-performance production test

AD9060KE standard पिन कॉन्फ़िगरेशन गाइड

AD9060KE (standard पैकेज) के लिए पिन कॉन्फ़िगरेशन। इस एनालॉग कंपोनेंट में इनपुट, आउटपुट और पावर सप्लाई पिन हैं। ऑफ़सेट नल, कम्पनसेशन और एनेबल पिन कॉन्फ़िगरेशन के लिए निर्माता डेटाशीट देखें। सिग्नल कंडीशनिंग और एम्प्लीफ़ायर सर्किट के लिए आदर्श।

AD9060KE के लिए standard पैकेज पिनआउट आरेख

इसके लिए कोई विस्तृत pinout data उपलब्ध नहीं: AD9060KE.

देखें डेटाशीट पूर्ण पिन कॉन्फ़िगरेशन के लिए।

सामान्य अनुप्रयोग

AD9060KE के लिए उपयुक्त है 6 अनुप्रयोगs: Digital Oscilloscope Front End, Medical Imaging Signal Acquisition, Professional Communications Receiver, Digital Oscilloscope and Laboratory Acquisition, Industrial Test and Measurement, Professional Signal Processing.

📺

Digital Oscilloscope Front End

The AD9060KE fits a high-speed oscilloscope acquisition channel because it converts at up to 75 MSPS with 10-bit resolution and produces ECL outputs for parallel digital transfer. Its 45 pF analog input capacitance reduces loading on the preceding signal-conditioning network, while the specified 57 dB SNR at a 2.3 MHz input provides useful dynamic range for repetitive waveform capture. The designer should use the datasheet timing diagram to align data and clock outputs, account for ECL trace termination, and preserve a short, controlled analog input path. As a parallel-output flash ADC, it also requires enough receiving logic or FPGA input resources to capture each conversion result.

💊

Medical Imaging Signal Acquisition

AD9060KE is suitable for medical imaging acquisition blocks where digitized image or diagnostic-sensor signals require rapid sampling. Its 75 MSPS word rate can capture waveform data efficiently, while the 10-bit output provides a practical balance between data volume and signal detail. The 45 pF input capacitance is particularly useful when the preceding amplifier, attenuator, or protection network must drive a limited capacitive load. Medical-equipment designs must verify the required regulatory, environmental, and qualification parameters independently, and any MIL-STD-883 requirement should use the specifically screened family variant rather than assuming that the commercial order code carries that qualification.

🌐

Professional Communications Receiver

The AD9060KE can serve as a sampling element in professional communications receiver and demodulation equipment requiring a parallel, high-speed conversion path. A 75 MSPS rate provides temporal headroom for analyzing modulation components, carrier bursts, or transient waveforms, while 10-bit resolution limits the digital representation to 1024 amplitude codes. Its ECL outputs can connect to compatible logic when timing and termination are designed carefully. Engineers should compare the converter's full-scale range, reference accuracy, and noise behavior against the receiver's weakest signal level, and should evaluate AD9060-100 when additional sampling bandwidth is useful and the revised timing can be accommodated.

🔧

Digital Oscilloscope and Laboratory Acquisition

AD9060KE supports laboratory-grade acquisition when a designer needs more conversion speed than a conventional low-rate SAR ADC but does not require the interfaces of a very high-end parallel ADC. The 75 MSPS throughput and 10-bit resolution make it appropriate for repetitive waveform, pulse, and transient measurements, while ECL outputs support parallel capture. Practical implementation requires disciplined clock distribution, matched trace lengths where timing margin is limited, correct ECL termination, and separate analog and digital supply treatment. Confirm the package pin assignments and output timing from the manufacturer documentation before allocating FPGA or custom logic resources.

🏭

Industrial Test and Measurement

The AD9060KE is applicable to industrial test equipment that acquires fast analog events and routes them into digital processing. Its 75 MSPS sampling rate allows repetitive production-test waveforms to be captured with 10-bit amplitude resolution, while the low 45 pF input capacitance helps maintain signal fidelity through source networks. The ECL interface is useful in instrumentation designed around high-speed parallel capture, but it can require more careful logic interfacing than CMOS or LVDS outputs. Validate input bandwidth, conversion timing, reference stability, and system noise floor during instrumentation design, and use the MIL-STD-883-compliant family option when production controls require that screening basis.

⚡

Professional Signal Processing

AD9060KE can be used in professional digital signal-processing systems where a rapid parallel ADC is needed before filtering, demodulation, or feature extraction. A 75 MSPS conversion rate and 10-bit resolution provide a practical sampling interface for digitized waveform analysis, while the ECL output interface supports direct connection to compatible high-speed logic. System partitioning should account for converter clocking requirements, data-bus width, synchronization of parallel outputs, and the latency between sampling and digital processing. For applications needing additional temporal resolution, AD9060-100 offers a 100 MSPS family configuration, but its clock, output, power, and signal-integrity conditions must be reviewed before PCB reuse.

अनुशंसित उत्पादों का सारांश

AD9060 Base family device for the same 75 MSPS conversion architecture उपयोग में: Digital Oscilloscope Front End, Medical Imaging Signal Acquisition, Digital Oscilloscope and Laboratory Acquisition, Industrial Test and Measurement AD9060/883B MIL-STD-883-compliant family option for controlled production environments उपयोग में: Digital Oscilloscope Front End, Medical Imaging Signal Acquisition, Industrial Test and Measurement AD9060-100 Higher-speed 100 MSPS family option for wider timing margin उपयोग में: Professional Communications Receiver, Digital Oscilloscope and Laboratory Acquisition, Professional Signal Processing AD9060-65 Lower-speed 65 MSPS family option for less demanding sampling paths उपयोग में: Professional Communications Receiver, Professional Signal Processing
Where can I buy AD9060KE online?
AD9060KE can be requested through the Request a Quote form on this page. The manufacturer identifies it as an Analog Devices 10-bit, 75 MSPS analog-to-digital converter, and the product page also notes that MIL-STD-883-compliant versions are available. Share the required quantity, package, operating grade, and delivery target with the quote team so that procurement can confirm the correct orderable configuration and current supply position.
What is the price of AD9060KE?
AD9060KE pricing should be obtained through the Request a Quote form on this page rather than from a static price figure. Quote processing can account for exact package, qualification grade, quantity, requested delivery, and current component availability. The device is a 10-bit, 75 MSPS ECL-output ADC, so confirm the suffix and package requirements before accepting a quotation.
What is the lead time for AD9060KE?
The current AD9060KE lead time is determined through the Request a Quote form on this page. Include the required quantity, target delivery date, and whether MIL-STD-883-compliant production is necessary. Analog Devices states that MIL-STD-883 versions are available, but qualification requirements and supply conditions should be confirmed for the exact order code rather than inferred from the standard AD9060KE configuration.
Is AD9060KE in stock?
AD9060KE inventory status should be confirmed through the Request a Quote form on this page. Quote requests should state the required quantity, acceptable date code, package, temperature grade, and screening requirements. This is especially important for a legacy high-speed ECL ADC because qualification screening and exact production configuration can affect availability and delivery planning.
What are the key specifications of AD9060KE that engineers should know?
The AD9060KE is a 10-bit monolithic flash ADC with a maximum specified sampling rate of 75 MSPS, ECL outputs, a bipolar 1.75 V analog input, and 45 pF input capacitance. Analog Devices specifies 57 dB SNR at a 2.3 MHz input. Its architecture uses 512 comparators rather than the 1024 associated with a traditional 10-bit flash implementation, supporting high-speed parallel sampling.
What is the operating voltage of AD9060KE?
The exact AD9060KE supply-voltage limits are not stated in the manufacturer product-page excerpt. Use the supply-voltage table, absolute-maximum ratings, and recommended operating conditions in the Analog Devices datasheet before assigning rails or designing decoupling. The AD9060 family uses ECL outputs, so the digital interface supply requirements and analog supply arrangement must both be checked rather than inferred from the output logic alone.
What is the AD9060KE pinout?
The complete AD9060KE pinout is not reproduced on the manufacturer product page excerpt. Use the pin-description table and package drawing in the Analog Devices AD9060 datasheet to assign analog inputs, references, supplies, clock signals, digital outputs, and grounds. Do not derive a pinout from the ECL output count or from visually similar ADC packages, because reserved and power pins can differ between package variants.
Where can I download the AD9060KE datasheet PDF?
The official Analog Devices product page for AD9060 is the primary starting point for documentation: https://www.analog.com/en/products/ad9060.html. Follow its datasheet and data-sheet links for the current AD9060/AD9060KE documentation, including electrical characteristics, pin descriptions, package drawings, interface timing, and ordering information. A separate AD9060KE datasheet mirror also identifies the device as a 10-bit, 75 MSPS A/D converter.
What is AD9060KE used for?
AD9060KE is intended for high-speed waveform acquisition in digital oscilloscopes, medical imaging, professional signal processing, communications, and test and measurement systems. Its 75 MSPS sampling rate supports rapid conversion, while 10-bit resolution and 57 dB SNR at 2.3 MHz suit applications where the captured waveform must retain useful amplitude and frequency information.
What can replace AD9060KE?
No cross-brand drop-in replacement can be confirmed from the available substitution records. Any proposed replacement must reproduce the ECL interface, supply arrangement, analog input characteristics, package, timing, and resolution rather than merely offering comparable resolution and speed. AD9060 family order codes such as AD9060/883B, AD9060-65, and AD9060-100 are the most relevant candidates to evaluate first, subject to exact package and timing verification.
Is AD9060KE the same as AD9060/883B?
AD9060/883B is related to AD9060 but is not automatically identical to the standard AD9060KE. Analog Devices states that AD9060 versions compliant with MIL-STD-883 are available and refers users to the AD9060/883B data sheet for detailed specifications. Treat the /883B device as a screened or qualified configuration only after checking its electrical limits, temperature grade, package, and ordering information.
AD9060KE vs AD9060-100 - which is better for high-speed sampling?
AD9060KE is the 75 MSPS baseline converter, while AD9060-100 is the higher-speed family option associated with a 100 MSPS word rate. Choose AD9060KE when 75 MSPS is sufficient and its exact configuration is required; evaluate AD9060-100 when the system needs the additional sampling rate and can accommodate its associated electrical and timing requirements. Both require package and pin-level verification before substitution.
When should I choose AD9060KE over a lower-speed ADC?
Choose AD9060KE when the acquisition path must sample at up to 75 MSPS while retaining a 10-bit output and ECL interface. Its 45 pF input capacitance can simplify source-interface loading compared with converters having higher input capacitance, while the 512-comparator flash architecture supports parallel conversion. A lower-speed ADC is preferable only when the required bandwidth, interface, power, and system timing do not justify a 75 MSPS converter.
Is AD9060KE suitable for digital oscilloscopes and medical imaging?
Yes, AD9060KE is specifically identified for digital oscilloscopes, medical imaging, and professional signal-processing applications. The 75 MSPS conversion rate captures fast-changing waveforms, while 10-bit resolution and 57 dB SNR at 2.3 MHz provide meaningful dynamic performance. Medical systems should additionally confirm the required regulatory, qualification, and environmental specifications before production use.
What is the best cross-brand equivalent for AD9060KE?
No verified cross-brand drop-in equivalent is identified for AD9060KE. The ECL output interface, analog input arrangement, supply rails, clocking method, package, and timing must all align before another manufacturer's converter can be considered a drop-in replacement. A cross-brand device with the same 10-bit resolution and approximate sampling rate may require a redesigned interface or PCB, so it should be treated as a redesign candidate rather than a true replacement.

के लिए इंजीनियरिंग संदर्भ डेटा AD9060KE — तुलना, डिज़ाइन मार्गदर्शन और अनुपालन जानकारी।

चयन गाइड

Choose AD9060KE when a system requires a 10-bit, 75 MSPS parallel ADC with ECL outputs, a bipolar 1.75 V input, and low 45 pF input capacitance. It is a practical choice for digital oscilloscopes, medical imaging, professional signal processing, communications, and laboratory instrumentation where 75 MSPS is sufficient and an established Analog Devices family interface is preferred. Choose AD9060-100 when additional sampling bandwidth is required and the revised clock, power, and output timing can be accommodated; choose AD9060-65 when lower throughput is acceptable and the original 75 MSPS timing does not need to be preserved. Use AD9060/883B when MIL-STD-883-compliant production is required. No cross-brand drop-in replacement is confirmed, so any other converter should be treated as a redesign unless its package, pins, ECL interface, supplies, and timing have been independently verified.

विकल्पों के साथ तुलना

पैरामीटर यह उत्पाद AD9060/883B AD9060-65 AD9060-100
Package Ceramic DIP-28 Ceramic DIP-28 Ceramic DIP-28 Ceramic DIP-28
Brand Analog Devices Analog Devices Analog Devices Analog Devices
Resolution 10 bit 10 bit 10 bit 10 bit
Sampling Rate 75 MSPS 75 MSPS 65 MSPS 100 MSPS
Digital Output Interface ECL ECL ECL ECL

मुख्य विशेषताएँ

  • Standard 75 MSPS configuration balances conversion throughput and exact family timing (बनामAD9060-100)
  • Higher sampling rate than the reduced-speed family option (बनामAD9060-65)
  • MIL-STD-883-compliant configuration is identifiable for controlled production programs (बनामAD9060KE)

डिज़ाइन नोट्स

Treat the ECL outputs and clock connections as a high-speed differential-design problem even though the converter is only 10 bits. Follow the manufacturer timing diagram for clock-to-output delay, skew, setup, and hold requirements; route the clock with short, controlled traces and keep parallel data outputs in a consistent timing group. Use the prescribed termination and supply arrangement because ECL thresholds and interconnect reflections can create data errors that are difficult to diagnose from static logic tests.

Keep the 45 pF analog input path compact and place input and bypass components according to the recommended application circuit. Separate sensitive analog routing from the parallel ECL output region and clock distribution, and use a continuous ground plane unless the datasheet specifies a different partition. Validate reference and power decoupling with an oscilloscope because reference instability or shared supply noise can degrade the specified 57 dB SNR at 2.3 MHz.

Do not substitute a converter based only on 10-bit resolution and sampling rate. The AD9060 family uses ECL outputs, and a valid replacement must also match the analog input range, clock and output timing, supply arrangement, reference behavior, package dimensions, pin assignments, and temperature requirements. The /883B, -65, and -100 family order codes represent different screening or speed choices, so each must be checked against the original system requirements before PCB reuse.

Dynamic performance is fully characterized and production tested at +25°C according to Analog Devices. When the converter operates in a warmer enclosure or near other high-speed logic, use the datasheet power-dissipation and junction-temperature information to calculate the worst-case rise. Keep airflow around the ceramic package, provide stable regulator output, and verify performance across temperature rather than assuming that production-test performance at +25°C applies automatically at elevated ambient temperature.

अनुपालन जानकारी

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
लीड फ्री
Unknown
हैलोजन फ्री
Unknown
कॉन्फ्लिक्ट मिनरल्स
Unknown

Analog Devices states that AD9060 versions compliant with MIL-STD-883 are available. RoHS, REACH, lead-free, halogen-free, and conflict-mineral statements were not identified in the available manufacturer material.

डेटा सत्यापन तिथि: 2026-11-04 — डेटा XAIPART की कंपोनेंट इंजीनियरिंग टीम द्वारा सत्यापित और क्यूरेट किया गया

संबंधित खोजें

AD9060KE datasheet AD9060KE pinout AD9060KE datasheet pdf AD9060KE specifications AD9060KE equivalent AD9060KE replacement AD9060KE cross reference AD9060KE vs AD9060-100 AD9060KE footprint AD9060KE application circuit Analog Devices AD9060KE AD9060KE price

संबंधित कंपोनेंट्स और शब्द

Analog Devices AD9060KE AD9060 AD9060/883B AD9060-65 AD9060-100 analog-to-digital converter ADC flash ADC parallel-sampling ADC monolithic converter 10-bit resolution 75 MSPS ECL signal-to-noise ratio 57 dB SNR 45 pF input capacitance bipolar analog input 512 input comparators digital oscilloscope medical imaging professional signal processing MIL-STD-883 Ceramic DIP-28 parallel digital output
त्वरित क़ौतिल आदेश (RFQ)
पूर्ण विवरण भरें — हमारी सेल्स टीम 24 घंटे के भीतर जवाब देगी
पार्ट नंबर निर्माता पैकेज QTY लक्ष्य कीमत विस्तारित
✓
उद्धरण प्रस्तुत!

हम आपकी ईमेल पर 24 घंटे के भीतर जवाब देंगे

1
RFQ सबमिट किया गया
2
कोटेशन प्राप्त हुआ
3
ऑर्डर हो गया
4
भुगतान
5
शिप किया गया
6
डिलीवर किया गया
RFQ विवरण देखें