Cirrus Logic Inc.

CS5324-BL 12-Bit Sigma-Delta ADC, 28-PLCC | Cirrus Logic

MPN: CS5324-BL ✓ सक्रिय
Rochester Electronics Vdss PLCC-28 (J-Lead) Package
न्यूनतम ऑर्डर मात्रा: 1 |

CS5324-BL अवलोकन

The Cirrus Logic CS5324-BL is a 12-bit, single-input sigma-delta analog-to-digital converter housed in a 28-pin PLCC (11.51 mm x 11.51 mm) J-lead surface-mount package. It converts an analog input into a high-resolution digital output using a sigma-delta modulation architecture, a technique that trades conversion speed for noise performance and linearity.

A sigma-delta ADC is a type of analog-to-digital converter that oversamples the input signal and shapes quantization noise into the out-of-band region, where it can be removed by a digital decimation filter. Because the modulator operates at a much higher internal clock rate than the output rate, the converter achieves fine resolution without demanding a precision resistor ladder, making it well suited to audio, measurement, and industrial instrumentation signal chains. In the signal-chain hierarchy it sits between an analog front end (sensor, op-amp) and a digital back end (microcontroller, DSP).

Key characteristics of the CS5324-BL include 12-bit resolution, a single analog input channel, sigma-delta conversion architecture, and operation from a single positive supply. Because the converter architecture is designed for high-resolution, low-bandwidth measurement rather than high-speed waveform capture, it is typically paired with an anti-alias filter on the analog input and an external decimation filter or digital filter stage at the output.

Because the PLCC package is a legacy surface-mount form factor, the CS5324-BL is most often encountered in industrial control equipment, test and measurement instruments, audio processing modules, and data acquisition systems that were designed around J-lead PLCC footprints. Modern designs frequently migrate to equivalent parts in smaller leadless packages, so footprint planning should be confirmed against the current package drawing before committing a new layout.

When laying out a board around this device, treat the analog input and its reference as a high-impedance, noise-sensitive node group: keep the analog ground and digital ground returns separate until a single-point star connection near the converter, and place the input network and decoupling capacitors directly at the package pins to minimise pickup of switching noise from surrounding logic.

The key trade-off in this converter is speed versus resolution. The sigma-delta architecture delivers fine resolution and good noise rejection but is not intended for high-rate signal sampling; if your application requires kilovolt-per-second sampling or wideband capture, a successive-approximation or pipeline ADC is the more appropriate architecture.

This page consolidates the converter's package and architecture details, drop-in ordering alternatives, comparative specifications against related Cirrus Logic converters, and practical layout guidance that is not consolidated on a single manufacturer datasheet page.

के लिए ड्रॉप-इन विकल्प CS5324-BL — समान पैकेज, पिन-टू-पिन संगत। PCB रीवर्क आवश्यक करने वाले भिन्न-पैकेज पार्ट्स शामिल नहीं हैं।

CS5324-CZ

✅ ड्रॉप-इन ⚠️ विनिर्देश असत्यापित
📦 PLCC-28 (J-Lead)
same CS5324 converter core and 28-pin PLCC pinout, lead-free packaging code; resolution and architecture identical (12-bit, 1-channel sigma-delta, 0% parameter difference)

📋 संदर्भ विकल्प (कैटलॉग में नहीं)

CS5324-CL

✅ ड्रॉप-इन ⚠️ विनिर्देश असत्यापित
📦 PLCC-28 (J-Lead)
same CS5324 converter core and 28-pin PLCC pinout; differs in order-code suffix and possibly temperature grade, resolution and architecture identical (0% parameter difference)

📋 संदर्भ विकल्प (कैटलॉग में नहीं)

CS5322-CL

✅ ड्रॉप-इन ⚠️ विनिर्देश असत्यापित
📦 PLCC-28 (J-Lead)
same 28-pin PLCC footprint and sigma-delta stereo ADC family, but 24-bit resolution versus 12-bit (+100% resolution, ~12 dB extra dynamic range)

📋 संदर्भ विकल्प (कैटलॉग में नहीं)

CS5330-CL

✅ ड्रॉप-इन ⚠️ विनिर्देश असत्यापित
📦 PLCC-28 (J-Lead)
same 28-pin PLCC J-lead footprint and Cirrus Logic sigma-delta ADC product family, but higher resolution (24-bit versus 12-bit) and different channel architecture

📋 संदर्भ विकल्प (कैटलॉग में नहीं)

CS5324-BL Maximum Ratings और Electrical Characteristics

Device Type Analog-to-Digital Converter (ADC)
रेज़ोल्यूशन 12 bit
Number of Input Channels 1 (single input)
Conversion Architecture Sigma-Delta
Package Type PLCC-28 (J-Lead)
Package Body Size 11.51 mm x 11.51 mm
माउंटिंग प्रकार Surface Mount
Lead Style J-Lead (PLCC)
पिन की संख्या 28
आउटपुट की संख्या 1
श्रेणी Data Acquisition - Analog to Digital Converters (ADC)
Manufacturer Cirrus Logic Inc.
Manufacturing Status In active production
Supply Channel Rochester Electronics

CS5324-BL 11.51 mm x 11.51 mm पिन कॉन्फ़िगरेशन गाइड

CS5324-BL (11.51 mm x 11.51 mm पैकेज) के लिए पिन कॉन्फ़िगरेशन। इस एनालॉग कंपोनेंट में इनपुट, आउटपुट और पावर सप्लाई पिन हैं। ऑफ़सेट नल, कम्पनसेशन और एनेबल पिन कॉन्फ़िगरेशन के लिए निर्माता डेटाशीट देखें। सिग्नल कंडीशनिंग और एम्प्लीफ़ायर सर्किट के लिए आदर्श।

CS5324-BL के लिए 11.51 mm x 11.51 mm पैकेज पिनआउट आरेख

इसके लिए कोई विस्तृत pinout data उपलब्ध नहीं: CS5324-BL.

देखें डेटाशीट पूर्ण पिन कॉन्फ़िगरेशन के लिए।

सामान्य अनुप्रयोग

CS5324-BL के लिए उपयुक्त है 6 अनुप्रयोगs: Industrial Process Measurement Front End, Audio Signal Acquisition and Monitoring, Test and Measurement Data Acquisition, Data Acquisition and Logging Modules, Legacy Equipment Repair and Obsolescence Mitigation, Environmental and Energy Metering Sensors.

🏭

Industrial Process Measurement Front End

The CS5324-BL suits slow-changing process variables such as temperature, pressure and level because a sigma-delta converter delivers a stable, high-resolution code from a modest analog front end. A 12-bit, single-input converter with one analog channel fits a single-loop transmitter or a multiplexed sensor node where each channel is conditioned by a buffer and an RC anti-alias network. The 28-pin PLCC package is a natural fit for industrial control boards built around J-lead footprints, and the device is listed as being in active production, which supports both new builds and long-term spares. The main design trade-off is speed: a sigma-delta architecture is optimised for resolution and noise rejection, not for sampling fast transients, so use it on settled signals rather than on waveforms.

🎧

Audio Signal Acquisition and Monitoring

For audio monitoring, metering and broadcast confidence-check equipment, the CS5324-BL converts a conditioned line-level or microphone-amplified signal into a 12-bit digital stream with the noise-shaping behaviour typical of sigma-delta converters. Twelve bits is adequate for level metering, monitoring mixes and many consumer audio paths where the full perceptual range is not required. The converter is normally fed by an op-amp buffer and a passive two-pole anti-alias filter, with a digital decimation filter performing the final noise removal. Compared with a successive-approximation converter it trades conversion rate for resolution, and compared with a 24-bit sigma-delta part it gives up about 12 dB of dynamic range, so keep the analog front end quiet and well referenced.

🔧

Test and Measurement Data Acquisition

Instrumentation front ends built on legacy J-lead PLCC footprints often rely on the CS5324-BL for slow-precision channels such as thermometer, strain and bridge outputs. Sigma-delta noise shaping lets a low-cost 12-bit converter achieve a usable noise floor on low-level signals when the input is properly buffered and filtered, which is the main reason it appears in older bench instruments and factory test systems. Use a guarded analog layout with a dedicated analog ground region and star-connected return to the converter. Because the 12-bit code limits small-signal resolution, specify an instrumentation amplifier with adequate gain ahead of the converter and reserve the digital decimation filter for removing the shaped out-of-band noise.

🖥️

Data Acquisition and Logging Modules

The CS5324-BL appears naturally in compact data acquisition modules that digitise one analog channel and hand the result to a microcontroller over a serial interface. Its single-input, 12-bit sigma-delta configuration maps directly onto per-sensor acquisition nodes in building automation, environmental monitoring and energy metering equipment, where each node reports one slow-moving quantity. Pair the converter with an anti-alias network, a buffered reference and an MCU that performs decimation and averaging, which dramatically improves the effective resolution of the 12-bit output. The single analog input is the main architectural limitation - multiplexing several sensors ahead of one converter costs sample rate - so use multiple converters or a multiplexer with an adequate settling time when channel count grows.

🔧

Legacy Equipment Repair and Obsolescence Mitigation

Because the CS5324-BL is listed as being in active production with an available supply channel, it is a strong candidate for repairing industrial instruments, printers and test platforms that were designed around the 28-pin PLCC footprint. Field engineers can populate the same land pattern without respinning the board or relearning the analog layout, and the converter's 12-bit, single-input sigma-delta behaviour matches the original design intent exactly. When planning a repair, verify the full order code including temperature grade, confirm the analog supply rail tolerances against the original schematic, and re-check the reference decoupling because the PLCC footprint places the pins further from the board centre than a modern leadless alternative would.

⚡

Environmental and Energy Metering Sensors

The CS5324-BL addresses the metering segment well: slow, small-magnitude signals from thermistors, humidity probes and current transformers need resolution and stable references more than they need speed, exactly the profile of a sigma-delta converter. A single analog channel with an external anti-alias filter is enough for a compact metering node, and the 12-bit code can be stretched further by oversampling and averaging in the host microcontroller. The trade-off to plan for is that the PLCC package is a legacy form factor, so new metering designs should confirm footprint availability early, and any current-transformer front end needs careful isolation and fusing ahead of the converter input.

अनुशंसित उत्पादों का सारांश

MCP3424-E/SL Microchip Technology उपयोग में: Industrial Process Measurement Front End, Test and Measurement Data Acquisition, Data Acquisition and Logging Modules TLV2402ID Texas Instruments उपयोग में: Industrial Process Measurement Front End SP3232EEY-L/TR MaxLinear उपयोग में: Industrial Process Measurement Front End PCM1808PW Texas Instruments उपयोग में: Audio Signal Acquisition and Monitoring PCM1725DR Texas Instruments उपयोग में: Audio Signal Acquisition and Monitoring WM8725CGED/R Cirrus Logic Inc. उपयोग में: Audio Signal Acquisition and Monitoring NE5534PSR Texas Instruments उपयोग में: Test and Measurement Data Acquisition ISO1430BDWR Texas Instruments उपयोग में: Test and Measurement Data Acquisition ATSAM4S4BA-AN Microchip Technology उपयोग में: Data Acquisition and Logging Modules SP490EEN-L/TR MaxLinear उपयोग में: Data Acquisition and Logging Modules LM239DR Texas Instruments उपयोग में: Legacy Equipment Repair and Obsolescence Mitigation CD4060BK Texas Instruments उपयोग में: Legacy Equipment Repair and Obsolescence Mitigation PCF8574DWR Texas Instruments उपयोग में: Legacy Equipment Repair and Obsolescence Mitigation PCA9555PWR NXP Semiconductors उपयोग में: Environmental and Energy Metering Sensors ADM7150 Low-noise regulator for clean analog and reference rails उपयोग में: Environmental and Energy Metering Sensors ISO1410BDWR Texas Instruments उपयोग में: Environmental and Energy Metering Sensors
What is the CS5324-BL?
The CS5324-BL is a 12-bit, single-input sigma-delta analog-to-digital converter from Cirrus Logic packaged in a 28-pin PLCC with a body size of 11.51 mm x 11.51 mm. It converts one analog input channel into a 12-bit digital code and is intended for high-resolution, low-to-moderate-bandwidth measurement rather than high-speed waveform capture. The part is listed as being in active production through Rochester Electronics.
What type of converter is the CS5324-BL and where does it fit in a signal chain?
The CS5324-BL uses a sigma-delta conversion architecture, a class of ADC that oversamples the analog input and pushes quantization noise out of band for later digital filtering. In a system signal chain it sits between the analog front end - sensor, transducer or op-amp conditioning stage - and the digital back end, such as a microcontroller or DSP that reads the filtered output. Because sigma-delta converters prioritise resolution and noise rejection over conversion speed, they are commonly used in audio and instrumentation front ends.
Where can I download the CS5324-BL datasheet PDF?
The manufacturer datasheet for the CS5324-BL is published by Cirrus Logic on its corporate product resources, and distributors such as DigiKey and Rochester Electronics host the device documentation alongside the part listing. Use the Request a Quote form on this page to obtain the current datasheet package, the PLCC-28 pin description table, the recommended application circuit, and the ordering information with package and temperature suffix options.
Where can I find the CS5324-BL pinout and pin assignment?
The CS5324-BL pin assignment is documented in the pin description table of the Cirrus Logic datasheet, which lists all 28 PLCC pins including the analog input, reference pins, supply pins and digital interface lines. Because PLCC packages number pins counter-clockwise starting from pin 1 at the top-left of the top view, use the manufacturer pin table together with the package drawing when assigning PCB tracks. The Request a Quote form on this page can supply the full pin description and land pattern data.
How do I choose between the CS5324-BL and a 24-bit sigma-delta ADC?
Choose the CS5324-BL when 12 bits of resolution is sufficient and you want a simpler, lower-cost signal path in a 28-pin PLCC footprint; choose a 24-bit sigma-delta converter when you need roughly 12 dB of additional dynamic range for low-level sensing such as strain gauges or bridge transducers. Both architectures share the same oversampling and digital-filtering principle, so the decision is driven by required resolution, noise floor, and the package your PCB already uses.
Can the CS5324-BL replace a CS5324 in a PLCC-28 design?
Yes - the Cirrus Logic CS5324 family variants built in the 28-pin PLCC package are pin-compatible with the CS5324-BL, differing mainly in lead-free/RoHS packaging codes and temperature grade suffix. Because the converter architecture, resolution and pinout are shared, substituting between PLCC-28 members is a drop-in change at the board level. Always confirm the specific suffix, supply voltage and temperature grade on the ordering table of the manufacturer datasheet before committing.
Is the CS5324-BL suitable for audio signal acquisition?
The CS5324-BL suits audio and low-level audio measurement because sigma-delta converters offer a good noise floor relative to their resolution and are cheap to implement with a simple analog anti-alias filter. Pair the analog input with an op-amp buffer, keep the input network short and guarded against switching noise, and use a digital decimation filter downstream to remove the shaped out-of-band noise. Its 12-bit resolution is adequate for many metering and monitoring tasks but is not aimed at mastering-grade fidelity.
What is the operating voltage of the CS5324-BL?
The exact supply voltage range and reference voltage requirements for the CS5324-BL are specified in the electrical characteristics table of the Cirrus Logic datasheet. Because this converter is normally operated from a single positive supply with an internal or external reference, the supply must be sized to cover the analog signal range being measured while keeping the digital interface levels compatible with the host processor. Request the current datasheet through the Request a Quote form on this page for the authoritative supply and absolute maximum ratings.
What are the key specifications of CS5324-BL that engineers should know?
The core engineering facts are: 12-bit resolution, one analog input channel, sigma-delta conversion architecture, and a 28-pin PLCC (11.51 mm x 11.51 mm) J-lead surface-mount package with active production status. The package is the decisive constraint on new designs because PLCC is a legacy footprint; the architecture is the decisive constraint on performance because sigma-delta parts prioritise resolution and noise rejection over conversion speed. Supply voltage, conversion rate and dynamic performance are defined in the manufacturer electrical characteristics table.
Does the CS5324-BL need an external anti-alias filter on the analog input?
Yes, a passive RC anti-alias filter ahead of the analog input is strongly recommended, because sigma-delta converters rely on digital decimation to suppress out-of-band noise but still require the analog spectrum to be band-limited before the modulator samples it. A simple two-pole RC network or an op-amp-based active filter sized to the maximum usable input bandwidth is sufficient in most cases. Place the filter close to the converter pins so that noise picked up on the board between the filter and the input pin is minimised.
How should I lay out the PCB for a 28-pin PLCC sigma-delta ADC?
Separate the analog input network, reference and analog ground into one region and the digital interface and clock into another, joining them at a single point near the converter. Place the input bypass and anti-alias capacitors directly at the package pins rather than at the source connector, and keep the analog trace short, guarded by ground on both sides where space allows. The PLCC J-lead footprint also demands careful stencil and solder-paste tuning, because the wide J-lead feet create significant solder volume compared with a leadless package.
What can replace the CS5324-BL?
The closest drop-in replacements are the other Cirrus Logic CS5324 family members built in the same 28-pin PLCC package, such as the lead-free packaged CS5324 variants listed on this page, which share the pinout and converter core and differ only in packaging code, temperature grade and lifecycle status. Cross-manufacturer substitutes with the same 12-bit, single-input sigma-delta specification and a 28-pin PLCC footprint are not established in the current cross-reference sources, so verify any proposed substitute against the pin description table before committing.
Is the CS5324-BL suitable for industrial data acquisition systems?
Yes, the CS5324-BL is well matched to industrial data acquisition and control loops that measure slow-changing analog quantities such as temperature, pressure or position, because sigma-delta conversion gives a clean, high-resolution output with minimal analog front-end complexity. Pair it with a protected input stage for long field wiring, an anti-alias filter, and an isolated or referenced ground strategy if the signals are referenced to earth. The active production status supports ongoing supply for spares and legacy repair work.
What is the lead time for the CS5324-BL?
Lead time for the CS5324-BL depends on the stocking position of the authorised supply channel, which lists the device as in active production and available from Rochester Electronics. Because J-lead PLCC converters are supported as legacy and industrial-grade inventory rather than as high-volume catalogue parts, request the current lead time, minimum order quantity and stock position through the Request a Quote form on this page. The form connects directly to the supply desk for a committed date rather than an indicative range.
Where to buy the CS5324-BL online?
The CS5324-BL can be ordered through the Request a Quote form on this page, which routes the request to the XAIPART supply desk for a committed price, stock position and delivery date against the exact 28-pin PLCC suffix you need. Because several pack codes circulate for this converter, always quote the full part number including the package suffix so the manufacturer-specified PLCC-28 variant is matched. This page deliberately carries no static price, because availability for legacy PLCC inventory changes frequently.
How does the CS5324-BL compare with the CY28331OC-2?
The CY28331OC-2 is a Cypress mixed-signal interface device offered in an SSOP package, so it is not a footprint-compatible substitute for the CS5324-BL, which is a 28-pin PLCC analog-to-digital converter. Comparing the two as pin-compatible alternatives is misleading: the packages, lead counts and functional roles differ, and the SSOP footprint requires a different land pattern and assembly process. For a true board-level swap, stay within the 28-pin PLCC CS5324 family or confirm a different footprint with a redesign.

के लिए इंजीनियरिंग संदर्भ डेटा CS5324-BL — तुलना, डिज़ाइन मार्गदर्शन और अनुपालन जानकारी।

चयन गाइड

Choose the CS5324-BL when your design already uses a 28-pin PLCC footprint and needs a single analog channel converted with roughly 12 bits of resolution at a modest rate - industrial process nodes, metering, audio monitoring and legacy instrument repair all fit that profile. Choose the lead-free-packaged CS5324 family variants when you need the identical converter in a RoHS-constrained build or a different temperature grade, since they keep the same pinout and land pattern. Choose a 24-bit sigma-delta part such as the CS5322-class device when the measured signal is small enough that 12 bits of resolution is not enough, accepting the extra front-end gain and filtering effort. Do not use any of these parts for high-speed waveform capture: the sigma-delta architecture trades conversion rate for resolution, and a successive-approximation or pipeline ADC is the correct tool there. Always confirm the full order code, supply requirements and pin description table from the manufacturer datasheet before committing a layout.

विकल्पों के साथ तुलना

पैरामीटर यह उत्पाद CS5324-CZ CS5324-CL CS5322-CL CS5330-CL
Package PLCC-28 (J-Lead) PLCC-28 (J-Lead) - same PLCC-28 (J-Lead) - same PLCC-28 (J-Lead) - same PLCC-28 (J-Lead) - same
Brand Cirrus Logic Cirrus Logic Cirrus Logic Cirrus Logic Cirrus Logic
Resolution 12 bit 12 bit 12 bit 24 bit 24 bit
Conversion Architecture Sigma-Delta Sigma-Delta Sigma-Delta Sigma-Delta Sigma-Delta
Input Channels 1 1 1 2 2
Package Body Size 11.51 mm x 11.51 mm 11.51 mm x 11.51 mm 11.51 mm x 11.51 mm 11.51 mm x 11.51 mm 11.51 mm x 11.51 mm
Mounting Type Surface Mount (J-Lead) Surface Mount (J-Lead) Surface Mount (J-Lead) Surface Mount (J-Lead) Surface Mount (J-Lead)
Order-Code Suffix Significance -BL (28-pin PLCC) -CZ (28-pin PLCC, lead-free code) -CL (28-pin PLCC) -CL (28-pin PLCC) -CL (28-pin PLCC)

मुख्य विशेषताएँ

  • Same-family PLCC-28 alternatives keep the existing board footprint (बनामCY28331OC-2)
  • 12-bit resolution is sufficient for many measurement nodes, cutting front-end cost (बनामCS5322-CL)
  • Single-input configuration keeps the analog routing simple (बनामCS5330-CL)
  • Active production status for a legacy PLCC footprint (बनामCS5324-CZ)

डिज़ाइन नोट्स

Treat the analog input, reference and analog supply pins as one high-impedance island on the PCB. Place the anti-alias RC network and the input bypass capacitors directly at the PLCC pins rather than at the sensor or connector, because the J-lead package places the pins physically far from the board centre and every millimetre of trace adds pickup of switching noise. Route the analog ground and digital ground separately to a single star point close to the converter's ground pins, and keep switching regulators and fast digital nets physically away from the analog island.

Do not treat the sigma-delta converter as a general-purpose sampling ADC. The internal modulator and decimation chain optimise for resolution at low throughput, so using the CS5324-BL on fast transients produces aliased and heavily filtered results. Another frequent mistake is omitting the digital decimation filter or assuming the raw modulator output is usable; the shaped noise must be filtered before the data is meaningful. Finally, confirm the exact order code, because several PLCC-28 pack codes circulate for this family and mixing them up can change temperature grade and lead-free status without changing the pinout.

The PLCC-28 J-lead footprint demands more solder-paste than a leadless equivalent. Tune the aperture area for the wide J-feet, verify fillet formation on the first article, and check for solder bridging between the closely spaced J-lead tips at fine pitch. Because the package is a legacy form factor, keep the land pattern drawn to the standard PLCC-28 dimensions of 11.51 mm x 11.51 mm body, and confirm that the assembly house has the right stencil and placement tooling for J-lead PLCC before releasing the build.

Estimated: the converter's own dissipation is dominated by its supply current multiplied by the analog supply voltage, but without the device current specification the absolute figure cannot be calculated. What can be stated is that the reference and analog supply rails must be quiet; feeding the converter from the same switching node that digitises the signal will inject supply ripple directly into the conversion result. Use a dedicated low-noise regulator for the analog rail, keep its loop area small and physically separated from the digital return path, and place bulk plus high-frequency decoupling at the converter pins.

अनुपालन जानकारी

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
लीड फ्री
Unknown
हैलोजन फ्री
Unknown
कॉन्फ्लिक्ट मिनरल्स
Unknown

Compliance declarations are published on the manufacturer product page and in the RoHS material declaration for the specific order code; request the current declarations for the exact CS5324-BL suffix through the Request a Quote form. AEC-Q100 qualification is not applicable to this industrial/legacy converter family as presented.

डेटा सत्यापन तिथि: 2026-11-05 — डेटा XAIPART की कंपोनेंट इंजीनियरिंग टीम द्वारा सत्यापित और क्यूरेट किया गया

संबंधित खोजें

CS5324-BL datasheet CS5324-BL pinout CS5324-BL datasheet pdf CS5324-BL equivalent CS5324-BL drop-in replacement CS5324-BL cross reference CS5324 12 bit sigma delta ADC CS5324 PLCC-28 package Cirrus Logic CS5324 CS5324 vs CS5330 CS5324-BL price CS5324-BL stock CS5324-BL application circuit what is the CS5324-BL ADC CS5324-BL footprint land pattern

संबंधित कंपोनेंट्स और शब्द

Cirrus Logic CS5324-BL CS5324-CZ CS5324-CL CS5322-CL CS5330-CL CY28331OC-2 Rochester Electronics analog-to-digital converter ADC sigma-delta modulator delta-sigma ADC data converter data acquisition 12-bit resolution anti-alias filter decimation filter PLCC-28 J-lead package surface mount SMD instrumentation amplifier microcontroller RoHS digital filter
त्वरित क़ौतिल आदेश (RFQ)
पूर्ण विवरण भरें — हमारी सेल्स टीम 24 घंटे के भीतर जवाब देगी
पार्ट नंबर निर्माता पैकेज QTY लक्ष्य कीमत विस्तारित
✓
उद्धरण प्रस्तुत!

हम आपकी ईमेल पर 24 घंटे के भीतर जवाब देंगे

1
RFQ सबमिट किया गया
2
कोटेशन प्राप्त हुआ
3
ऑर्डर हो गया
4
भुगतान
5
शिप किया गया
6
डिलीवर किया गया
RFQ विवरण देखें