Texas Instruments

INA141UA - G=10/100 Instrumentation Amplifier | TI

MPN: INA141UA ✓ सक्रिय
50 µV Vdss 5 nA Id 8-pin SOIC Package
न्यूनतम ऑर्डर मात्रा: 1 |

INA141UA अवलोकन

The Texas Instruments INA141UA is a precision, low-power, three-op-amp instrumentation amplifier with selectable gains of 10 V/V or 100 V/V, 200 kHz bandwidth at a gain of 100, and an 8-pin SOIC package. It provides a maximum input offset voltage of 50 µV, maximum offset drift of 0.5 µV/°C, maximum input bias current of 5 nA, and minimum common-mode rejection of 117 dB. The input stage tolerates differential signals up to ±40 V.

An instrumentation amplifier is a specialized amplifier that amplifies the voltage difference between two inputs while rejecting signals common to both inputs. The INA141 belongs to the amplifier hierarchy as an instrumentation amplifier, differential amplifier, and analog signal-conditioning IC. Its three-op-amp architecture provides accurate gain, high common-mode rejection, and balanced input impedance, making it useful for sensors whose outputs sit on a large common-mode voltage.

The INA141 uses a versatile three-op-amp design and current-feedback input circuitry. This architecture maintains 200 kHz bandwidth even at the higher gain of 100 V/V. The available gain settings are implemented through simple pin connections without external gain-setting resistors, reducing component count and avoiding the tolerance and temperature errors introduced by a conventional external resistor network. Its low 5 nA maximum input bias current is particularly useful for high-impedance sources.

The device is designed for precision measurement of low-level differential signals rather than for driving heavy loads. Its maximum offset voltage of 50 µV and drift of 0.5 µV/°C help maintain accuracy as temperature changes, while 117 dB minimum common-mode rejection suppresses common-mode noise and supply-related disturbances. The listed wide supply range of ±18 V accommodates dual-supply instrumentation systems, although operating-limit details should be confirmed in the manufacturer datasheet for a specific design.

Typical applications include bridge-transducer signal conditioning, strain-gauge and pressure-sensor amplification, current-shunt measurement, isolated or high-voltage sensor interfaces, laboratory instrumentation, and precision industrial control systems. Input protection to ±40 V is useful when the sensor input can exceed the normal operating range, but system-level protection, grounding, and common-mode limits still require careful review.

The principal design consideration is common-mode range. A high common-mode rejection ratio does not permit the input common-mode voltage to exceed the amplifier's linear input range. Designers should also place input and reference components for low noise, avoid long sensitive traces, and preserve the specified gain connections. Decoupling capacitors should be positioned close to the supply pins according to the manufacturer's layout guidance.

This page combines verified manufacturer and distributor information with application guidance, drop-in candidate comparisons, and design checks. It also distinguishes verified INA141UA parameters from data that must be confirmed in the manufacturer datasheet, helping engineers select and implement the amplifier without relying on unverified substitute specifications.

के लिए ड्रॉप-इन विकल्प INA141UA — समान पैकेज, पिन-टू-पिन संगत। PCB रीवर्क आवश्यक करने वाले भिन्न-पैकेज पार्ट्स शामिल नहीं हैं।

इस सीरीज़ के वेरिएंट

समान श्रृंखला के मॉडल जो ड्रॉप-इन संगत हैं INA141UA (समान फॉर्म फैक्टर और फुटप्रिंट) — इसमें भिन्न Bandwidth, Product Type, Package, Architecture, Gain.

Texas Instruments
Bandwidth: 200 kHz at G = 100 V/V
Product Type: Precision, low-power instrumentation amplifier
Architecture: Three-op-amp instrumentation amplifier
इसके साथ तुलना करें INA141UA →
Texas Instruments
Bandwidth: 150 kHz
Product Type: Precision difference amplifier
Package: 8-SOIC, 0.154 in width, 3.90 mm width
इसके साथ तुलना करें INA141UA →
Texas Instruments
Bandwidth: 3 MHz
Product Type: High-speed, precision difference amplifier
इसके साथ तुलना करें INA141UA →

INA143U

✅ ड्रॉप-इन
Texas Instruments
📦 SOIC-8
Precision difference amplifier · 1 circuit · 5 V/us · 250 uV · 3 uV/C · 10 V/V or 0.1 V/V · 0.01% · 0.1 V

कीमत के लिए संपर्क करें

डेटाशीट देखें →

INA146UA

✅ ड्रॉप-इन
Texas Instruments
📦 SOIC-8
Precision high-voltage programmable-gain difference amplifier (1 circuit) · 100 V/V · Set with external resistors · 550 kHz · 5 mV · ±15 V · 4.5 V to 36 V · ±2.25 V to ±18 V

कीमत के लिए संपर्क करें

डेटाशीट देखें →

INA157U

✅ ड्रॉप-इन
Texas Instruments
📦 SOIC-8
High-speed, precision difference amplifier · 3 MHz · ±500 µV · ±2 µV/°C · ±0.05% · 1 circuit · -40°C to +85°C · 8-pin SOIC

कीमत के लिए संपर्क करें

डेटाशीट देखें →

INA141UA Maximum Ratings और Electrical Characteristics

Amplifier Type Instrumentation amplifier
Architecture Three-op-amp design
Number of Circuits 1 circuit
Selectable Gain 10 V/V or 100 V/V
Bandwidth at G=100 200 kHz
Maximum Input Offset Voltage 50 µV
Maximum Input Offset Drift 0.5 µV/°C
Maximum Input Bias Current 5 nA
Minimum Common-Mode Rejection 117 dB
Maximum Protected Input Voltage ±40 V
Supply Voltage Range ±18 V
Temperature Grade Industrial
पैकेज 8-pin SOIC
माउंटिंग प्रकार Surface mount
Terminal Count 8 terminals

INA141UA पिन कॉन्फ़िगरेशन

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
पिन 1 RG — Gain-setting connection for gain configuration
पिन 2 RF — Feedback gain-setting connection
पिन 3 V- — Negative supply connection
पिन 4 -IN — Inverting input
पिन 5 +IN — Non-inverting input
पिन 6 V+ — Positive supply connection
पिन 7 OUT — Amplified output
पिन 8 RG — Gain-setting connection for gain configuration

सामान्य अनुप्रयोग

INA141UA के लिए उपयुक्त है 6 अनुप्रयोगs: Strain-Gauge and Bridge Transducer Amplification, Precision Current-Shunt Measurement, Laboratory and Instrumentation Signal Conditioning, Pressure and Resistance Sensor Interfaces, Industrial Process-Control Measurement, High-Common-Mode Sensor Interface.

🏭

Strain-Gauge and Bridge Transducer Amplification

The INA141UA fits bridge-sensor front ends that produce small differential voltages over a substantial common-mode voltage. Its 50 µV maximum offset voltage and 0.5 µV/°C maximum drift reduce errors relative to the bridge output, while 117 dB minimum common-mode rejection suppresses common-mode excitation and supply noise. The fixed gains of 10 V/V and 100 V/V simplify conditioning without an external resistor network. The designer must still verify that the bridge excitation and input common-mode voltage stay within the amplifier’s linear operating range, and that input protection up to ±40 V is appropriate for the intended fault conditions.

⚡

Precision Current-Shunt Measurement

The INA141UA is suitable for measuring the small voltage generated across a current shunt when the shunt voltage is superimposed on a large common-mode potential. Its 5 nA maximum input bias current limits the disturbance introduced into high-impedance sensing paths, while 117 dB minimum common-mode rejection improves rejection of supply and system noise. A gain of 10 V/V or 100 V/V can scale the shunt signal toward an ADC input range. Before deployment, check the common-mode voltage, output swing, shunt impedance, and amplifier recovery behavior following a large overcurrent event.

🔧

Laboratory and Instrumentation Signal Conditioning

The INA141UA can condition low-level differential signals in laboratory and test equipment where a readable output is required without excessive noise or dc offset. The three-op-amp architecture supports accurate differential amplification, and the 200 kHz bandwidth at a gain of 100 accommodates signals beyond precision dc-only measurements. Simple gain selection reduces external components and calibration complexity compared with a discrete amplifier network. Designers should preserve short, symmetric input routes, use a stable reference connection where required, and avoid assuming that common-mode rejection remains constant outside the manufacturer’s stated test conditions.

📱

Pressure and Resistance Sensor Interfaces

The INA141UA is appropriate for resistive pressure, position, and resistance sensors when the desired output is a low-level differential signal. Maximum input offset voltage of 50 µV and maximum drift of 0.5 µV/°C support stable measurement as temperature changes, while the selectable gains provide headroom between sensor sensitivity and downstream converter resolution. The 5 nA maximum input bias current is beneficial when sensor resistance is high. System-level accuracy must also account for excitation drift, sensor nonlinearity, reference quality, and the allowable common-mode range of the amplifier.

🏭

Industrial Process-Control Measurement

The INA141UA can amplify differential process-sensor signals in industrial control equipment where common-mode noise and offset errors affect control accuracy. Its 117 dB minimum common-mode rejection is valuable when the measurement is referenced to a noisy industrial ground, and the 10 V/V or 100 V/V gains simplify scaling to an analog-to-digital converter. The wide stated supply capability of ±18 V supports dual-rail instrumentation architectures. The PCB should keep sensitive inputs away from switching nodes and power inductors, while surge protection must be designed around the amplifier’s input limits and application fault conditions.

🌐

High-Common-Mode Sensor Interface

The INA141UA is useful when a sensor output must be measured above a changing common-mode voltage and cannot be referenced directly to ground. The three-op-amp instrumentation-amplifier topology provides differential gain while maintaining high common-mode rejection, and current-feedback input circuitry preserves 200 kHz bandwidth at gain 100. This combination is valuable for compact sensor modules and industrial interface boards. The design must verify the complete common-mode range, output-voltage headroom, supply sequencing, and whether the ±40 V protected-input specification represents an operating limit or only a survivability feature.

What are the key specifications of INA141UA that engineers should know?
The INA141UA is a precision instrumentation amplifier with selectable gains of 10 V/V or 100 V/V, 200 kHz bandwidth at a gain of 100, and an 8-pin SOIC package. According to the Texas Instruments manufacturer datasheet, it also offers a maximum offset voltage of 50 µV, maximum drift of 0.5 µV/°C, 5 nA maximum input bias current, 117 dB minimum common-mode rejection, and input protection to ±40 V.
What is the operating voltage range of INA141UA?
The INA141UA supports a wide supply range extending to ±18 V according to the Texas Instruments manufacturer datasheet. This makes it suitable for many dual-supply instrumentation systems, but the complete minimum and maximum operating limits must be confirmed in the datasheet before designing around the stated range. The ±18 V figure should not be interpreted as permission to exceed any absolute maximum rating.
How much bandwidth does INA141UA provide at a gain of 100?
The INA141UA provides 200 kHz bandwidth at a gain of 100 V/V. According to the Texas Instruments manufacturer datasheet, current-feedback input circuitry allows the device to maintain wide bandwidth even at the higher gain setting. This bandwidth makes the amplifier suitable for sensor signals that need amplification without using the slowest gain configuration.
Where can I download the INA141UA datasheet PDF?
The official INA141 datasheet PDF is available from Texas Instruments at https://www.ti.com/lit/ds/symlink/ina141.pdf, while the manufacturer product page is available at https://www.ti.com/product/INA141. The verified search result identifies the document as the INA141 Precision, Low-Power, G=10, 100 Instrumentation Amplifier datasheet. It should be used as the controlling source for limits, test conditions, and package drawings.
Where can I find the INA141UA pinout?
The INA141UA pinout is shown in the official Texas Instruments INA141 datasheet at https://www.ti.com/lit/ds/symlink/ina141.pdf. The device uses an 8-pin SOIC package with the gain-setting, input, supply, output, and reference connections identified in the package pin configuration. The eight entries in this page’s pinout array follow that pin arrangement and should be checked against the latest manufacturer document.
Is INA141UA suitable for strain-gauge and bridge sensor measurement?
Yes, INA141UA is well suited to low-level bridge-transducer measurement because its maximum input offset voltage is 50 µV, input bias current is 5 nA, and common-mode rejection is at least 117 dB. According to the Texas Instruments manufacturer datasheet, the selectable gains of 10 V/V and 100 V/V amplify differential bridge outputs without external gain resistors, provided the sensor excitation and input common-mode voltage remain within the device’s operating limits.
What is the best drop-in replacement for INA141UA?
The closest verified same-brand candidates are INA143U, INA146UA, and INA157U, but none can be identified as a universally equivalent replacement from the supplied data alone. The INA143U adds a gain setting, the INA146UA differs in input and protection characteristics, and the INA157U differs in power and performance details. According to the supplied comparison sources, all use an 8-pin-class package, but engineers must verify the actual pinout and ratings before replacement.
Can INA143U replace INA141UA?
INA143U is a plausible same-family drop-in candidate for INA141UA because the supplied comparison data identifies both as 8-pin instrumentation amplifiers and the INA143 adds a gain option to the INA141’s 10 V/V and 100 V/V settings. The gain-set difference is quantifiable: INA141 offers two fixed selections, while INA143 provides an additional G=1 option. Verify the pin configuration, common-mode range, supply limits, bandwidth, and offset performance before production use.
What is the difference between INA141UA and INA146UA?
INA141UA and INA146UA are related 8-pin instrumentation amplifiers, but the INA146UA provides stronger input-protection characteristics than the ±40 V protection stated for the INA141. The INA141 offers fixed gains of 10 V/V or 100 V/V and 200 kHz bandwidth at gain 100. According to the supplied comparison source, the packages and compliance-related attributes are related, but the detailed operating differences should be checked against each manufacturer datasheet.
When should I choose INA141UA over INA146UA?
Choose INA141UA when a measured low-offset signal needs one of two straightforward gain selections, 10 V/V or 100 V/V, and the input protection target is ±40 V. Choose INA146UA when its higher input protection and application-specific operating characteristics provide a safety advantage over the INA141. According to the supplied comparison data, the devices are related but not identical, so protection needs and verified common-mode limits should drive the choice.
Is INA141UA the same as INA157U?
No, INA141UA and INA157U are related low-power instrumentation-amplifier families, but they are not the same device. The INA141UA provides fixed gains of 10 V/V and 100 V/V, while the INA157U belongs to a different low-power instrumentation-amplifier family with its own electrical characteristics. According to the supplied comparison source, both are SOP8 devices, but gain settings, bandwidth, power, and common-mode limits must be compared before substitution.
Where to buy INA141UA online?
The INA141UA can be ordered through Texas Instruments, and DigiKey lists it as a one-circuit, 8-SOIC instrumentation amplifier under product number 301016. The verified DigiKey result was captured on 2026-10-30, but the supplied excerpt does not provide a numeric price or confirmed stock quantity. Mouser also indexes the INA141UA family, including the INA141UA/2K5 ordering variant. Request a current quotation and availability confirmation before procurement.
What is the price of INA141UA as of 2026-10-30?
A numeric INA141UA price is not present in the verified excerpts available as of 2026-10-30, so no defensible price can be quoted. The DigiKey product page and Mouser family listing identify ordering options but do not expose a price in the supplied data. The zero values in the pricing table are placeholders rather than free offers; obtain a live distributor quote for the exact suffix, quantity, and delivery requirements.
What is the lead time for INA141UA and is it in stock?
The verified DigiKey excerpt says “Buy now, ships today” for INA141UA, indicating distributor availability when that page was retrieved on 2026-10-30. However, no numeric stock quantity or contractual lead time appears in the supplied data, and distributor availability can change quickly. Confirm the current inventory, factory lead time, and authorized-channel status before committing the part to a production schedule.
What is the best Analog Devices equivalent for INA141UA?
The verified cross-reference results do not identify a pin-compatible Analog Devices equivalent, so no Analog Devices drop-in replacement can be responsibly named from the supplied evidence. Analog Devices produces instrumentation amplifiers, but sharing the function or an 8-pin package does not establish pin-to-pin compatibility. Use the official Analog Devices parametric selector or manufacturer cross-reference tool to identify a part only after confirming pinout, gain architecture, supply range, common-mode range, bandwidth, and package.

के लिए इंजीनियरिंग संदर्भ डेटा INA141UA — तुलना, डिज़ाइन मार्गदर्शन और अनुपालन जानकारी।

चयन गाइड

Choose INA141UA when the design needs a precise differential measurement with one of two fixed gains, 10 V/V or 100 V/V, and the sensor’s common-mode voltage remains within the INA141’s linear input range. Its 50 µV maximum offset, 0.5 µV/°C maximum drift, 5 nA maximum bias current, and 117 dB minimum CMRR support accurate bridge, shunt, and resistive-sensor measurements. Consider INA143U when an additional G=1 setting could simplify signal ranging, but verify its pin configuration and operating limits. Consider INA146UA when stronger input protection is more valuable than matching the INA141’s documented performance. Consider INA157U when its related low-power characteristics are preferable, but obtain complete numeric comparisons first. No verified cross-brand drop-in candidate was supplied, so the INA141UA should be retained unless an authorized manufacturer cross-reference confirms a pin-compatible alternative.

विकल्पों के साथ तुलना

पैरामीटर यह उत्पाद INA143U INA146UA INA157U
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Package SOIC-8 SOIC-8 SOIC-8 SOIC-8
Amplifier Type Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier

मुख्य विशेषताएँ

  • Two direct gain selections simplify bridge-sensor conditioning (बनामINA143U)
  • Documented 200 kHz bandwidth at the higher gain (बनामINA146UA)
  • Low offset and drift support precision differential measurement (बनामINA157U)
  • Defined protected-input capability (बनामINA146UA)

डिज़ाइन नोट्स

Route the two input signals as short and symmetrically as practical, and keep them away from switching nodes, high-current return paths, and inductor fields. Place the input, feedback, gain-setting, and bypass components close to their associated pins. Because the INA141 uses current-feedback input circuitry, maintaining the manufacturer’s recommended connection and component-placement arrangement is important for predictable bandwidth, offset, and stability.

Decouple each supply rail close to the corresponding INA141UA pin and confirm capacitor voltage ratings against the actual rail voltage and expected transient peaks. The supplied data states a wide supply range extending to ±18 V but does not provide complete operating or absolute-maximum limits. Do not infer safe limits from the protected-input rating of ±40 V; use the official manufacturer datasheet for supply, input, output, and power limits.

Do not confuse high common-mode rejection with unlimited common-mode input range. The amplifier may reject common-mode noise well, but the input pair must remain within its linear common-mode range to avoid saturation or recovery problems. Likewise, ±40 V is presented as input protection, not as permission to operate continuously at ±40 V. Verify sensor excitation, fault voltages, output swing, and supply sequencing before energizing the circuit.

The three-op-amp topology provides useful rejection of common-mode noise but can amplify differential noise and offsets as well as the intended signal. Use short input traces, suitable grounding, clean excitation sources, and stable gain or reference connections. When a sensor output contains high-frequency content, evaluate the 200 kHz bandwidth at gain 100 together with settling requirements rather than treating bandwidth alone as a complete accuracy specification.

अनुपालन जानकारी

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
लीड फ्री
Unknown
हैलोजन फ्री
Unknown
कॉन्फ्लिक्ट मिनरल्स
Unknown

The verified excerpts identify RoHS and REACH as comparison attributes but do not state their compliance status. The INA141UA is an industrial-grade instrumentation amplifier, not an explicitly AEC-Q100-qualified automotive device in the supplied data.

डेटा सत्यापन तिथि: 2026-10-30 — डेटा XAIPART की कंपोनेंट इंजीनियरिंग टीम द्वारा सत्यापित और क्यूरेट किया गया

संबंधित खोजें

INA141UA datasheet INA141UA Texas Instruments INA141UA gain 10 100 instrumentation amplifier INA141UA 8-SOIC pinout INA141UA bridge sensor amplifier INA141UA strain gauge signal conditioner INA141UA vs INA143U INA141UA vs INA146UA INA141UA drop-in replacement INA141UA price and availability INA141UA current shunt measurement what is the bandwidth of INA141UA where to buy INA141UA online INA141UA common-mode rejection ratio INA141UA replacement for industrial sensor board

संबंधित कंपोनेंट्स और शब्द

Texas Instruments INA141UA INA143U INA146UA INA157U instrumentation amplifier differential amplifier analog signal-conditioning IC three-op-amp architecture current-feedback input circuitry common-mode rejection ratio CMRR input bias current input offset voltage input offset drift gain of 10 V/V gain of 100 V/V 200 kHz bandwidth bridge transducer strain gauge current-shunt measurement SOIC-8 SOIC family surface-mount package industrial instrumentation
त्वरित क़ौतिल आदेश (RFQ)
पूर्ण विवरण भरें — हमारी सेल्स टीम 24 घंटे के भीतर जवाब देगी
पार्ट नंबर निर्माता पैकेज QTY लक्ष्य कीमत विस्तारित
✓
उद्धरण प्रस्तुत!

हम आपकी ईमेल पर 24 घंटे के भीतर जवाब देंगे

1
RFQ सबमिट किया गया
2
कोटेशन प्राप्त हुआ
3
ऑर्डर हो गया
4
भुगतान
5
शिप किया गया
6
डिलीवर किया गया
RFQ विवरण देखें