Monolithic Power Systems

MP8049SDU-LF-Z - 24V 5.5A Quad Class-D | MPS

MPN: MP8049SDU-LF-Z ✓ सक्रिय
24 V Vdss 5.5 A Id 40-QFN, 5 mm × 5 mm Package
न्यूनतम ऑर्डर मात्रा: 1 |

MP8049SDU-LF-Z अवलोकन

Monolithic Power Systems MP8049SDU-LF-Z is a 24 V, 5.5 A quad-channel Class-D audio power driver configured as four half-bridge outputs, or two configurable full-bridge outputs, in a 40-pin QFN 5 mm × 5 mm package. The device provides selectable forced-PWM and asynchronous operating modes, programmable output-level control, dynamic output-voltage control, integrated power MOSFET switches, and an internal Schottky diode. In forced-PWM mode, the output current reaches 1.5 A, while asynchronous mode supports 50 mA. The MP8049S family can operate each full bridge independently as stereo single-ended audio amplifiers or drive the bridges complementarily in bridged-tie-load configurations. Its integration reduces external discrete switching hardware, while selectable modes let designers trade switching behavior and output characteristics according to the audio architecture.

A Class-D audio power driver is the output-stage category used to convert PWM commands into high-current speaker drive. The broader hierarchy is Class-D power driver → audio power amplifier → amplifier integrated circuit → power-management and signal-chain semiconductor. The MP8049S is primarily an output-stage driver rather than a complete audio signal-chain amplifier, so its usefulness depends on upstream control, modulation, fault handling, and system-level protection. It is suitable where a compact quad-channel architecture is valuable, including multiway speakers, soundbars, compact consumer audio, industrial audio modules, and powered speaker systems.

Key features include user-selectable forced-PWM and asynchronous operation, separate programmable output levels for each operating mode, dynamic output-voltage control, integrated power MOSFETs, and an integrated Schottky diode. Forced PWM provides a predictable switching mode at up to 1.5 A output current, while asynchronous operation is specified at 50 mA. Dynamic output-voltage control can reduce dissipation when the commanded output level is low, although the exact control method and external components must be implemented according to the manufacturer datasheet. The reported 24 V and 5.5 A ratings describe the family's headline operating capability and should not be interpreted as simultaneously available output power at every load or mode.

The MP8049S architecture provides two configurable full bridges or four half bridges, allowing the same device family to support multiple speaker topologies. Forced-PWM mode helps control output behavior where consistent switching timing is important, whereas asynchronous operation can reduce switching activity at lower signal levels. The integrated MOSFETs eliminate separate output switching transistors in supported configurations, while the Schottky diode supports the associated rectification function. Exact pin assignments, protection limits, thermal data, operating-temperature limits, and recommended compensation or filtering networks must be confirmed in the MP8049S datasheet.

Typical applications include compact stereo Class-D amplifiers, quad-channel distributed speaker systems, soundbar output stages, powered speakers, multimedia enclosures, and industrial audio modules. The 40-QFN 5 mm × 5 mm package supports space-constrained products but requires careful PCB layout for thermal dissipation, high-current output routing, ground integrity, and clean input/PWM routing. Design engineers should account for the difference between the 5.5 A device rating, the 1.5 A forced-PWM output-current specification, and the 50 mA asynchronous-mode specification when sizing speakers and protection networks.

A primary design consideration is to keep high-current speaker outputs, power ground, and switching nodes compact and isolated from sensitive audio inputs. Place input and PWM-control traces away from output-current paths, use the datasheet-recommended power and ground-plane arrangement, and provide thermal copper around exposed-pad connections. Avoid treating the asynchronous-mode 50 mA rating as interchangeable with the forced-PWM rating; validate mode-specific current, thermal, and acoustic behavior in the final enclosure.

This page consolidates the verified manufacturer and distributor information for the MP8049SDU-LF-Z, distinguishes device-family ratings from mode-specific limits, and adds engineering guidance on topology selection, thermal layout, current routing, and verified replacement constraints. No unverified cross-brand drop-in substitute is presented as a direct replacement.

के लिए ड्रॉप-इन विकल्प MP8049SDU-LF-Z — समान पैकेज, पिन-टू-पिन संगत। PCB रीवर्क आवश्यक करने वाले भिन्न-पैकेज पार्ट्स शामिल नहीं हैं।

इस उत्पाद के लिए कोई drop-in alternatives उपलब्ध नहीं।

विकल्प अनुरोध करें

MP8049SDU-LF-Z Maximum Ratings और Electrical Characteristics

Product Type Quad-channel Class-D audio power driver
Rated Supply Voltage 24 V
Headline Device Current Rating 5.5 A
Forced-PWM Output Current Up to 1.5 A
Asynchronous-Mode Output Current 50 mA
आउटपुट कॉन्फ़िगरेशन 4 half-bridge channels or 2 configurable full-bridge channels
Forced-PWM Mode User selectable
Asynchronous Mode User selectable
Output-Level Control User programmable for each operating mode
Output Voltage Control Dynamic
Power Stage Internal power MOSFET switches
Rectifier Element Internal Schottky diode
Output Capacitor Stability Stable with low-ESR output ceramic capacitors
Full-Bridge Configuration Independent stereo single-ended or complementary BTL operation
Low-Current Shutdown Supported
Standby Mode Supported
पैकेज 40-QFN, 5 mm × 5 mm
माउंटिंग प्रकार Surface mount
Shipping Format Tape and reel

MP8049SDU-LF-Z 40-qfn, 5 mm × 5 mm पिन कॉन्फ़िगरेशन गाइड

MP8049SDU-LF-Z (40-qfn, 5 mm × 5 mm पैकेज) के लिए पिन कॉन्फ़िगरेशन। इस एनालॉग कंपोनेंट में इनपुट, आउटपुट और पावर सप्लाई पिन हैं। ऑफ़सेट नल, कम्पनसेशन और एनेबल पिन कॉन्फ़िगरेशन के लिए निर्माता डेटाशीट देखें। सिग्नल कंडीशनिंग और एम्प्लीफ़ायर सर्किट के लिए आदर्श।

MP8049SDU-LF-Z के लिए 40-qfn, 5 mm × 5 mm पैकेज पिनआउट आरेख

इसके लिए कोई विस्तृत pinout data उपलब्ध नहीं: MP8049SDU-LF-Z.

देखें डेटाशीट पूर्ण पिन कॉन्फ़िगरेशन के लिए।

सामान्य अनुप्रयोग

MP8049SDU-LF-Z के लिए उपयुक्त है 6 अनुप्रयोगs: Compact Stereo Class-D Speaker Amplifier, Quad-Channel Distributed Speaker System, Soundbar Multi-Channel Output Stage, Powered Speaker and Portable Audio, Industrial Audio Control Module, Multimedia and Active Speaker Enclosure.

🎧

Compact Stereo Class-D Speaker Amplifier

The MP8049SDU-LF-Z can form the output stage of a compact stereo Class-D amplifier by using its configurable dual-full-bridge capability. Each full bridge may operate as a stereo single-ended stage or as a complementary BTL output, while the 40-QFN 5 mm × 5 mm package preserves board area in space-constrained products. Forced-PWM operation is specified up to 1.5 A, so designers should match speaker impedance, continuous output demand, and thermal conditions to that mode-specific rating. The 24 V and 5.5 A family headline values must not be substituted for a guaranteed continuous output-power figure. Final implementation requires the manufacturer-recommended output filter, power network, PWM interface, and exposed-pad land pattern to control distortion, switching noise, and junction temperature.

🌐

Quad-Channel Distributed Speaker System

The MP8049SDU-LF-Z is appropriate for a distributed speaker architecture requiring four independently controlled half-bridge outputs in one package. Its four-channel configuration reduces the number of separate output-driver packages needed for a multiway or multi-zone speaker product, and the integrated MOSFET switches simplify the power stage. Mode selection is especially important because forced PWM supports up to 1.5 A while asynchronous operation is specified at 50 mA. Engineers should determine whether all channels can remain in forced PWM, whether per-channel level control is sufficient, and how standby and shutdown behavior interact with the amplifier controller. Speaker filtering, protection, high-current routing, and thermal verification remain essential for reliable continuous operation.

📺

Soundbar Multi-Channel Output Stage

A soundbar can use the MP8049SDU-LF-Z to implement several speaker outputs without allocating a separate power-driver package for every channel. The device offers four half-bridge outputs or two full bridges, while selectable forced-PWM and asynchronous modes let the system designer evaluate acoustic behavior and efficiency under different signal conditions. The 40-QFN 5 mm × 5 mm package also helps meet the shallow enclosure and board-area constraints typical of soundbars. However, compact enclosure construction can limit heat dissipation, so calculations must use worst-case simultaneous channel load and the manufacturer’s thermal guidance. Switching-node layout, output-filter selection, channel-to-channel crosstalk, and the approved standby sequence should be validated before production release.

📱

Powered Speaker and Portable Audio

The MP8049SDU-LF-Z can serve as the Class-D output section of a powered speaker or portable-audio product where multiple low- and high-frequency channels must be driven from a compact board. Its configurable bridge topology supports integrated, bridged speaker connections, and dynamic output-voltage control may help manage dissipation when the commanded signal level is low. The engineering trade-off is that a compact enclosure restricts heat rejection and portable systems often tolerate abrupt supply or load changes, so the design must include suitable protection and verified filtering. Forced-PWM current capability is stated as up to 1.5 A, whereas asynchronous mode is stated at 50 mA; the selected operating mode and duty cycle therefore define the usable speaker load more directly than the family’s 5.5 A headline rating.

🏭

Industrial Audio Control Module

The MP8049SDU-LF-Z is suited to industrial audio modules that require a configurable high-current output stage and predictable mode selection. Two full bridges can be configured independently, allowing a controller to support single-ended stereo, complementary BTL, or four half-bridge arrangements according to the installed speaker topology. In an industrial enclosure, thermal design may be easier than in a portable product, but long operating cycles and continuous audio still require conservative copper-area and airflow assumptions. Low-current shutdown and standby functions support system power management, yet their timing and enable polarity must be taken directly from the MP8049S datasheet. Grounding and isolation between high-current outputs and sensitive control circuitry are particularly important in industrial installations.

🖥️

Multimedia and Active Speaker Enclosure

The MP8049SDU-LF-Z can implement the Class-D power stage for active multimedia speakers, multimedia enclosures, and powered subwoofer assemblies. Its integrated MOSFETs and selectable PWM behavior reduce external driver-component count, while the compact QFN package supports dense consumer-electronics layouts. A multimedia product may switch among high-demand and low-level conditions, making forced-PWM and asynchronous evaluation important for both audible noise and efficiency. Dynamic output-voltage control may lower dissipation at reduced output levels, but its real benefit must be demonstrated under the product’s control algorithm and load. Designers should also verify output filtering, channel synchronization, thermal rise, and connector-level ESD protection because the exposed power stage and external speaker terminals are exposed to user-accessible transients.

What is the operating voltage of MP8049SDU-LF-Z?
The MP8049SDU-LF-Z is associated with a 24 V rated operating supply in the MP8049S family. According to the manufacturer product page, the device is a configurable Class-D output stage for two full-bridge or four half-bridge channels. The verified headline rating is 24 V and 5.5 A, but designers must use the manufacturer datasheet for absolute maximum, recommended operating, and derating limits before applying that rating to a specific board.
What are the key specifications of MP8049SDU-LF-Z that engineers should know?
The MP8049SDU-LF-Z is a 24 V, 5.5 A quad-channel Class-D power driver in a 40-QFN 5 mm × 5 mm package. Its verified features include forced-PWM operation up to 1.5 A, asynchronous operation up to 50 mA, programmable output levels for each mode, dynamic output-voltage control, internal power MOSFETs, and an internal Schottky diode. The manufacturer also identifies dual full-bridge or quad half-bridge configurations and operation with low-ESR ceramic output capacitors.
What output current can MP8049SDU-LF-Z deliver in forced-PWM mode?
The MP8049SDU-LF-Z can deliver up to 1.5 A in forced-PWM mode, according to the indexed manufacturer-datasheet description. This is the mode-specific output-current figure and should not be confused with the 5.5 A headline family rating or the 50 mA asynchronous-mode rating. Actual continuous capability depends on supply voltage, switching frequency, output configuration, thermal conditions, speaker impedance, and the protection and layout requirements in the manufacturer datasheet.
Can MP8049SDU-LF-Z operate as four half-bridge channels?
Yes. The MP8049S can be configured as four half-bridge channels or two dual full-bridge channels. According to the manufacturer product page, each full bridge can be driven independently as stereo single-ended audio amplifiers or driven complementarily in a bridged-tie-load configuration. This configurability lets one device family address multiple speaker topologies, but the PWM inputs, output network, filtering, and channel mapping must be implemented exactly as described in the manufacturer datasheet.
What is the difference between forced-PWM and asynchronous modes in MP8049SDU-LF-Z?
Forced-PWM mode provides continuous, controlled switching and is specified up to 1.5 A output current, while asynchronous mode is specified at 50 mA. The manufacturer lists both modes as user selectable, with user-programmable output level for each mode. The practical distinction is that the modes offer different output-current and switching characteristics, so a design should be validated in the intended operating mode rather than relying only on the 24 V, 5.5 A family headline ratings.
Where can I download the MP8049SDU-LF-Z datasheet PDF?
The official MP8049S manufacturer datasheet is available through the Monolithic Power Systems product-document link listed on this page. The same MP8049S datasheet also appears through Octopart. Use the manufacturer PDF for authoritative pin assignments, recommended circuits, absolute maximum ratings, thermal information, and operating limits; distributor-hosted copies are secondary access points and may differ in document version.
Where can I find the MP8049SDU-LF-Z pinout?
The MP8049SDU-LF-Z pinout is located in the MP8049S manufacturer datasheet, which covers the 40-QFN 5 mm × 5 mm device used for the MP8049SDU orderable designation. The supplied web records establish the package and device family but do not expose all individual pin names, so this page does not reproduce an inferred 40-pin map. Download the official datasheet and use its package drawing and pin-description table before laying out or inspecting a populated board.
Where can I buy MP8049SDU-LF-Z online?
MP8049SDU-LF-Z can be found through DigiKey and Mouser, and additional marketplace listings are indexed by Octopart and ICMASS. The DigiKey result states that the part ships today and provides current product access, while Mouser lists the 24 V, 5.5 A quad-channel power half-bridge device with datasheet, inventory, and pricing links. Confirm the exact suffix, authorized-channel status, quantity, and current stock directly with the distributor before issuing a purchase order.
What is the price of MP8049SDU-LF-Z as of 2026-10-30?
A verified numeric unit price for MP8049SDU-LF-Z was not included in the supplied distributor records as of 2026-10-30, so no defensible price can be quoted. The product pages on DigiKey, Mouser, Octopart, and ICMASS expose live pricing interfaces, but their snippets do not contain the actual amount. Request a current quotation from an authorized distributor and confirm whether the price applies to a full reel, cut tape, or another authorized packing form.
Is MP8049SDU-LF-Z in stock?
The supplied DigiKey result explicitly states “Buy now, ships today,” indicating listed availability as of the 2026-10-30 retrieval. Other distributor records expose inventory and pricing fields without including exact stock quantities. Availability can change quickly and may vary by package quantity and authorized sales channel, so engineers should confirm current inventory and lead time with the distributor for the planned production quantity.
What is the lead time for MP8049SDU-LF-Z?
The verified DigiKey listing states that MP8049SDU-LF-Z ships today, but the supplied records do not provide a numeric production lead time as of 2026-10-30. For bulk procurement, ask the distributor for committed lead time, scheduled delivery, and lot-allocation information because a distributor stocking announcement does not necessarily represent factory lead time. The 40-QFN tape-and-reel format and authorized-channel status should also be confirmed.
MP8049SDU-LF-Z vs MP8049S: which is the right orderable designation?
MP8049S identifies the device family and its manufacturer datasheet, while MP8049SDU-LF-Z is the specific distributor-listed orderable designation. The verified sources describe both as a 24 V, 5.5 A quad-channel Class-D power half-bridge device in a 40-QFN 5 mm × 5 mm package. They are not separate drop-in competitors; engineers should use the complete ordering code MP8049SDU-LF-Z when purchasing and the MP8049S datasheet for technical documentation.
When should I choose MP8049SDU-LF-Z over a discrete Class-D output stage?
Choose MP8049SDU-LF-Z when a compact, integrated quad-half-bridge or dual-full-bridge Class-D output stage is more valuable than discrete MOSFET control. The device integrates power MOSFET switches, supports selectable forced-PWM and asynchronous modes, and provides programmable output levels and dynamic output-voltage control. A discrete stage may offer different power, thermal, protection, or modulation flexibility, so the decision should be based on verified continuous output requirements rather than package size alone.
Is MP8049SDU-LF-Z suitable for a compact powered speaker?
MP8049SDU-LF-Z can suit a compact powered speaker when its verified electrical limits match the speaker load and amplifier topology. Its 40-QFN 5 mm × 5 mm package helps reduce board area, while the 24 V, 5.5 A family rating and selectable operating modes support Class-D output-stage designs. Confirm forced-PWM current capability, thermal performance, output filtering, speaker impedance, and enclosure dissipation before approving it for continuous audio output.
What is the best drop-in replacement for MP8049SDU-LF-Z?
No distinct drop-in replacement was verified for MP8049SDU-LF-Z in the supplied cross-reference results. The search surfaced the underlying MP8049S family and generic cross-reference tools, but it did not establish another manufacturer’s part as having the same 40-QFN footprint, pin functions, power-stage ratings, and configuration controls. Because a same-package audio power driver is not automatically pin-compatible, any replacement must be checked against the official pin table and electrical specifications before use.
Can another Monolithic Power Systems device replace MP8049SDU-LF-Z?
The MP8049S family documentation covers the target technology, but no separate same-package orderable MPN was verified as a functionally distinct drop-in alternative. Packaging, temperature, or reel-code variants do not add meaningful engineering value and are not treated as alternatives here. The practical same-family path is therefore to use the MP8049S documentation with MP8049SDU-LF-Z and to seek an authorized-distributor quotation rather than assume that a similar MPS audio driver has an identical pinout.

के लिए इंजीनियरिंग संदर्भ डेटा MP8049SDU-LF-Z — तुलना, डिज़ाइन मार्गदर्शन और अनुपालन जानकारी।

चयन गाइड

Choose MP8049SDU-LF-Z when the design needs an integrated 24 V Class-D output stage with four half-bridge or two configurable full-bridge channels, selectable forced-PWM and asynchronous modes, programmable mode-specific output levels, and dynamic output-voltage control. It is particularly useful when minimizing board area and external switching-component count matters. Choose a discrete MOSFET output stage when the project needs different power ratings, custom modulation, independent protection, or thermal behavior not provided by the integrated driver. No distinct cross-brand drop-in replacement was verified, so a different audio driver should be considered only after checking its complete 40-pin mapping, continuous-current capability, switching method, control interface, output filter, and thermal data. Within the MP8049S family, MP8049SDU-LF-Z should be treated as the specific orderable designation and MP8049S as the technical family documented by the manufacturer.

विकल्पों के साथ तुलना

पैरामीटर यह उत्पाद
Brand Monolithic Power Systems
Package 40-QFN, 5 mm × 5 mm
Rated Supply Voltage 24 V
Headline Device Current Rating 5.5 A
Forced-PWM Output Current Up to 1.5 A
Asynchronous-Mode Output Current —
Channel Configuration 4 half-bridge channels or 2 full-bridge channels
Operating Modes User-selectable forced PWM and asynchronous mode
Power Stage Integration Internal power MOSFET switches and internal Schottky diode
Shipping Format Tape and reel

डिज़ाइन नोट्स

Treat the 1.5 A forced-PWM and 50 mA asynchronous figures as mode-specific limits rather than interchangeable ratings. Evaluate worst-case simultaneous channel loading, switching loss, copper losses, and ambient temperature using the manufacturer’s thermal guidance. The 40-QFN package relies on its exposed-pad and PCB copper system for heat spreading, so provide uninterrupted ground-plane access and sufficient copper area. Estimated thermal rise is intentionally omitted because the verified source set does not provide junction-to-ambient thermal resistance.

Route the 24 V supply, power ground, speaker outputs, and switching nodes as short, low-impedance paths. Keep sensitive input and PWM-control traces away from high-current output nodes, and follow the manufacturer’s recommended exposed-pad via and ground-plane geometry. Do not add extra vias or thermal structures solely by analogy with another QFN device; verify the exact package drawing and land pattern in the MP8049S datasheet.

Do not confuse the MP8049S family name with the orderable MP8049SDU-LF-Z designation, or the 5.5 A headline rating with the mode-specific output-current limits. Also avoid treating another 40-QFN audio IC as a drop-in replacement without comparing every pin, mode-control signal, output stage, and protection function. A footprint match alone does not prove pin compatibility for a configurable power driver.

Apply the datasheet-recommended output network consistently on every active half bridge or full bridge. If low-ESR ceramic output capacitors are used, maintain the recommended capacitance, voltage rating, tolerance, and placement because output-loop stability depends on physical layout as well as nominal capacitance. Validate filter ripple, phase margin, channel-to-channel behavior, and EMI with the final speaker cable and enclosure attached.

अनुपालन जानकारी

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
लीड फ्री
Unknown
हैलोजन फ्री
Unknown
कॉन्फ्लिक्ट मिनरल्स
Unknown

The verified source snippets do not provide explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals declarations. The device is an audio power-driver IC rather than an AEC-Q100 automotive-qualified variant, so automotive qualification is treated as not applicable based on the available ordering information.

डेटा सत्यापन तिथि: 2026-10-30 — डेटा XAIPART की कंपोनेंट इंजीनियरिंग टीम द्वारा सत्यापित और क्यूरेट किया गया

संबंधित खोजें

MP8049SDU-LF-Z MP8049SDU-LF-Z datasheet Monolithic Power Systems MP8049SDU-LF-Z MP8049SDU-LF-Z 24V 5.5A Class-D driver MP8049SDU-LF-Z 40-QFN 5x5 MP8049SDU-LF-Z quad half-bridge audio amplifier MP8049SDU-LF-Z vs MP8049S MP8049SDU-LF-Z drop-in replacement MP8049SDU-LF-Z price and stock Where to buy MP8049SDU-LF-Z online MP8049SDU-LF-Z forced PWM output current 40-QFN Class-D audio power driver MP8049SDU-LF-Z pinout

संबंधित कंपोनेंट्स और शब्द

Monolithic Power Systems MP8049SDU-LF-Z MP8049S Class-D audio power driver audio power amplifier amplifier integrated circuit power-management semiconductor quad-channel power half-bridge dual full-bridge driver forced-PWM mode asynchronous mode dynamic output-voltage control power MOSFET Schottky diode low-ESR ceramic capacitor bridged-tie-load configuration single-ended stereo standby mode shutdown mode 40-QFN QFN package family surface-mount package Class-D audio speaker driver output current
त्वरित क़ौतिल आदेश (RFQ)
पूर्ण विवरण भरें — हमारी सेल्स टीम 24 घंटे के भीतर जवाब देगी
पार्ट नंबर निर्माता पैकेज QTY लक्ष्य कीमत विस्तारित
✓
उद्धरण प्रस्तुत!

हम आपकी ईमेल पर 24 घंटे के भीतर जवाब देंगे

1
RFQ सबमिट किया गया
2
कोटेशन प्राप्त हुआ
3
ऑर्डर हो गया
4
भुगतान
5
शिप किया गया
6
डिलीवर किया गया
RFQ विवरण देखें