TLE7250LEXUMA1 अवलोकन

The Infineon TLE7250LEXUMA1 is an automotive half-duplex CAN transceiver for high-speed CAN networks, with a maximum classical CAN data rate of 1 Mbit/s and CAN FD operation up to 2 Mbit/s. It is packaged in an 8-pin PG-TSON-8-1 surface-mount package with an exposed pad and supplied in tape-and-reel packaging.

A CAN transceiver, also called a CAN interface IC or physical-layer transceiver, connects a CAN protocol controller to the differential CAN bus. It converts controller logic signals into CAN bus levels, receives bus signals, and provides the interface between the digital controller domain and the physical vehicle or industrial network. The TLE7250LE family is designed for automotive and industrial HS CAN networks and supports ISO 11898-2 operation.

The TLE7250LEXUMA1 provides one transceiver channel and is identified as a 1/1 transceiver in the product listing. Its principal operating specifications include a 5 V supply and a 1 Mbit/s classical CAN data rate. Infineon identifies the device as an automotive CAN transceiver with AEC-Q100 qualification, while the family documentation describes CAN FD support up to 2 Mbit/s and low electromagnetic emission and immunity characteristics.

The device is intended to be placed between a CAN protocol controller and the physical CAN_H and CAN_L bus conductors. Its bus interface protects the controller from interference generated within the network, while its receive path presents the bus state to the controller. Because it is a physical-layer device rather than a complete CAN controller, it requires a separate CAN protocol controller, an appropriate bus termination arrangement, and a correctly designed CAN bus harness.

Typical applications include automotive body-control modules, gateway units, comfort systems, engine-control electronics, industrial automation equipment, and other embedded CAN nodes. For 1 Mbit/s designs, the family data-rate rating and ISO 11898-2 compatibility are central selection criteria. Systems operating above the classical CAN limit should verify the complete CAN FD controller, bus timing, transceiver operating mode, and network topology.

A robust PCB layout should provide a short, symmetric route between the transceiver and CAN bus connector, maintain the bus differential impedance specified by the system, and minimize the loop area of CAN_H and CAN_L. Keep sensitive controller and reference circuitry away from the bus traces, provide the required bypass capacitance at the device, and use the exposed-pad land pattern for effective thermal dissipation.

This page consolidates the verified product identity, package information, automotive qualification, CAN capability, application guidance, and drop-in assessment into one engineering-focused view. It also distinguishes confirmed characteristics from parameters that require consultation of the current Infineon datasheet before layout release or production qualification.

के लिए ड्रॉप-इन विकल्प TLE7250LEXUMA1 — समान पैकेज, पिन-टू-पिन संगत। PCB रीवर्क आवश्यक करने वाले भिन्न-पैकेज पार्ट्स शामिल नहीं हैं।

इस सीरीज़ के वेरिएंट

समान श्रृंखला के मॉडल जो ड्रॉप-इन संगत हैं TLE7250LEXUMA1 (समान फॉर्म फैक्टर और फुटप्रिंट) — इसमें भिन्न Automotive Qualification, Package, Product Type.

Infineon
Automotive Qualification: AEC-Q100
Package: PG-DSO-8, 8-SOIC, 3.90 mm width
Product Type: LIN bus transceiver
इसके साथ तुलना करें TLE7250LEXUMA1 →

TLE7250LE

✅ ड्रॉप-इन
📦 PG-TSON-8-1
Same TLE7250LE family and CAN transceiver function; the suffix-specific ordering, temperature, and qualification details require confirmation against the Infineon ordering table.

📋 संदर्भ विकल्प (कैटलॉग में नहीं)

TLE7257SJXUMA1

✅ ड्रॉप-इन ⚠️ विनिर्देश असत्यापित
Infineon
📦 PG-TSON-8-1
LIN bus transceiver · 1 LIN bus · 1 transmitter and 1 receiver · 20 kbps · ISO 17987-4 compliant · Integrated voltage regulator, wake-up, and bus protection · Automotive battery network · -40 °C to +150 °C

कीमत के लिए संपर्क करें

डेटाशीट देखें →

TLE7250LEXUMA1 विशेषताएं

Product Type Automotive CAN transceiver
CAN Transceiver Channels 1 channel
Communication Mode Half duplex
Maximum Classical CAN Data Rate 1 Mbit/s
Maximum CAN FD Data Rate 2 Mbit/s
सप्लाई वोल्टेज 5 V
CAN Standard ISO 11898-2
Application Environment Automotive and industrial HS CAN networks
Automotive Qualification AEC-Q100 qualified
पैकेज 8-pin PG-TSON-8-1
Package Type Surface-mount TSON with exposed pad
Shipping Format Tape and reel
RoHS स्थिति Compliant

TLE7250LEXUMA1 surface-mount tson with exposed pad पिन कॉन्फ़िगरेशन गाइड

TLE7250LEXUMA1 (surface-mount tson with exposed pad पैकेज) के लिए पिन कॉन्फ़िगरेशन। पिन नंबरिंग, फ़ंक्शन और कनेक्शन आरेख निर्माता डेटाशीट में परिभाषित हैं। सटीक फुटप्रिंट और सोल्डरिंग दिशानिर्देशों के लिए इसे देखें।

TLE7250LEXUMA1 के लिए surface-mount tson with exposed pad पैकेज पिनआउट आरेख

इसके लिए कोई विस्तृत pinout data उपलब्ध नहीं: TLE7250LEXUMA1.

देखें डेटाशीट पूर्ण पिन कॉन्फ़िगरेशन के लिए।

सामान्य अनुप्रयोग

TLE7250LEXUMA1 के लिए उपयुक्त है 6 अनुप्रयोगs: Automotive Body Control Module, Automotive Gateway Controller, Engine Control Electronics, Industrial Automation Controller, Vehicle Comfort System ECU, Embedded CAN Sensor Node.

🚗

Automotive Body Control Module

The TLE7250LEXUMA1 fits an automotive body-control module that connects a CAN protocol controller to a vehicle network. Its 5 V supply, ISO 11898-2 physical-layer support, and 1 Mbit/s maximum classical CAN rate align with conventional automotive CAN links, while CAN FD capability up to 2 Mbit/s provides additional design headroom. The interface converts controller signals to differential bus levels and receives bus activity for the controller. Place the device close to the connector or harness branch, follow the exposed-pad thermal land pattern, and verify temperature grade, ESD behavior, and fault-mode requirements for the vehicle platform before production release.

🚗

Automotive Gateway Controller

A gateway controller commonly connects separate CAN domains, making transceiver signal integrity and interface protection important. The TLE7250LEXUMA1 provides one half-duplex physical-layer channel with a 1 Mbit/s classical CAN rating, CAN FD operation up to 2 Mbit/s, and a 5 V supply that supports integration with automotive controller electronics. The transceiver operates between the CAN protocol controller and differential CAN_H and CAN_L conductors, helping protect the controller from network-generated interference. For a gateway PCB, minimize the differential trace separation from the transceiver to the bus connector, provide clean ground return, and confirm timing and fault behavior in the complete network configuration.

🚗

Engine Control Electronics

The TLE7250LEXUMA1 is suitable for engine-control electronics requiring an Infineon automotive CAN interface. Its 1 Mbit/s maximum classical CAN data rate supports established vehicle networks, while the documented CAN FD capability of up to 2 Mbit/s can assist future designs that use higher-rate CAN FD traffic. The device operates from 5 V and provides the physical bus interface expected by a separate CAN protocol controller. Use an exposed-pad layout that minimizes thermal resistance, keep switching and high-current paths away from the CAN interface area, and validate the exact temperature range, transient response, common-mode limits, and diagnostic behavior on the target power architecture.

🏭

Industrial Automation Controller

The TLE7250LEXUMA1 can interface industrial automation equipment using an ISO 11898-2 high-speed CAN network. Its 5 V supply, one-channel half-duplex architecture, and 1 Mbit/s classical CAN rate fit compact PLCs, machine controllers, and factory communication modules. The CAN FD capability up to 2 Mbit/s is useful only when the controller, bus timing, cable characteristics, and all connected nodes support the higher rate. Keep the CAN_H and CAN_L route as a controlled differential pair, apply the termination scheme required by the bus topology, and use the exposed thermal pad and bypass layout specified by the manufacturer datasheet.

🚗

Vehicle Comfort System ECU

Body, climate, seating, and lighting comfort systems commonly use CAN links to exchange commands and sensor information. The TLE7250LEXUMA1 provides the differential physical-layer interface between such an electronic control unit and its CAN protocol controller. Its automotive AEC-Q100 designation supports the automotive context, while the 5 V supply and 1 Mbit/s classical CAN capability align with established in-vehicle networks. The half-duplex arrangement also helps reduce the component and wiring burden for one-channel nodes. Verify wake, standby, and sleep requirements if the ECU uses low-power operating modes, and follow the manufacturer pin and thermal-land instructions rather than relying on a generic TSON footprint.

🧩

Embedded CAN Sensor Node

The TLE7250LEXUMA1 can serve as the bus interface in an embedded sensor or actuator node that reports measurements to a CAN controller. Its one-channel, half-duplex configuration suits nodes with one physical CAN segment, and the 1 Mbit/s classical CAN rating accommodates common industrial and vehicle network speeds. The transceiver provides the physical-layer path while the separate controller handles arbitration, framing, error management, and diagnostics. Design the PCB with a short bus connection, controlled differential routing, solid ground continuity, and decoupling near the 5 V supply pins. Before deployment, verify the supported node count, bus common-mode range, ESD immunity, and behavior during bus faults against the operating environment.

What is the TLE7250LEXUMA1?
The TLE7250LEXUMA1 is an Infineon automotive half-duplex CAN transceiver with one CAN channel, a 1 Mbit/s maximum classical CAN rate, CAN FD support up to 2 Mbit/s, and a 5 V supply. According to the Infineon TLE7250 family documentation, it operates as the physical-layer interface between a CAN protocol controller and a differential CAN bus. The device is supplied in an 8-pin PG-TSON-8-1 package.
What is the operating voltage of the TLE7250LEXUMA1?
The TLE7250LEXUMA1 operates from a 5 V supply. The 5 V figure appears in the product listing for this exact automotive CAN transceiver. Confirm supply tolerances, ground-reference requirements, and power-up sequencing against the current Infineon TLE7250 datasheet before connecting the device to a vehicle harness or industrial bus.
What is the maximum CAN data rate of TLE7250LEXUMA1?
The TLE7250LEXUMA1 supports classical CAN data rates up to 1 Mbit/s and CAN FD operation up to 2 Mbit/s. According to the Infineon TLE7250LE product page, the family is designed for ISO 11898-2 networks. A CAN FD installation must also use a compatible controller, bus timing, transceiver mode, and network topology.
Where can I download the TLE7250LEXUMA1 datasheet PDF?
The official Infineon TLE7250 family datasheet is available at https://www.infineon.com/assets/row/public/documents/10/49/infineon-tle7250-ds-en.pdf. It contains the family description, application information, electrical characteristics, and interface details needed for design review. Use the ordering-code information and package drawings to confirm details for the exact TLE7250LEXUMA1 configuration.
Where can I find the TLE7250LEXUMA1 pinout?
The TLE7250LEXUMA1 pin assignment and PG-TSON-8-1 land pattern are defined in the official Infineon TLE7250 family datasheet. Use the pin-description table and package drawing together with the exposed-pad connection requirements. Assign PCB tracks directly from those diagrams rather than inferring transceiver pins from generic 8-pin CAN layouts.
Where to buy the TLE7250LEXUMA1 online?
The TLE7250LEXUMA1 can be requested through the Request a Quote form on this page. The exact device is listed as an Infineon 1/1 half-CAN-bus transceiver in an 8-pin PG-TSON-8-1 tape-and-reel package. A written request allows the required quantity, date code, lot traceability, and shipment destination to be confirmed before an order is placed.
What is the price of the TLE7250LEXUMA1?
Current price and quantity availability for the TLE7250LEXUMA1 are handled through the Request a Quote form on this page. The product is identified as an Infineon automotive CAN transceiver in an 8-pin PG-TSON-8-1 package. Include your target quantity and packaging requirements in the request so the quotation can reflect the appropriate supply configuration.
What is the lead time for the TLE7250LEXUMA1?
Request the current lead time, minimum order quantity, and stock status through the Request a Quote form on this page. Lead time can vary with quantity, date code, and manufacturing conditions, so a current supply confirmation is preferable to relying on a generic device-cycle estimate. For automotive production, also state the required traceability and qualification documentation.
Is the TLE7250LEXUMA1 in stock?
Use the Request a Quote form on this page for a current TLE7250LEXUMA1 stock and availability response. The exact MPN is an Infineon 8-pin PG-TSON-8-1 automotive CAN transceiver sold in tape-and-reel format. Supply confirmation should include quantity, lot or date-code requirements, and the delivery schedule needed by your build schedule.
What is the difference between TLE7250LEXUMA1 and TLE7250LE?
TLE7250LEXUMA1 is the orderable TLE7250LE device configuration with the automotive PG-TSON-8-1 packaging suffix, while TLE7250LE identifies the broader Infineon device family. According to Infineon documentation, the family is an ISO 11898-2 CAN transceiver for high-speed CAN networks. Use the manufacturer ordering table to verify suffix-specific electrical, temperature, and qualification details.
Can TLE7257SJXUMA1 replace TLE7250LEXUMA1?
The TLE7257SJXUMA1 is a potential candidate only after a complete pin, electrical, mode, and qualification review. Both are Infineon automotive CAN transceiver families, but the supplied material does not establish that every TLE7250LEXUMA1 function maps directly to the TLE7257SJXUMA1. Confirm pin compatibility, supply levels, bus behavior, sleep or standby requirements, and AEC-Q100 qualification before using it as a drop-in replacement.
When should I choose TLE7250LEXUMA1 over another CAN transceiver?
Choose the TLE7250LEXUMA1 when the design requires an Infineon automotive HS CAN physical layer with a 5 V supply, one transceiver channel, a 1 Mbit/s classical CAN rate, CAN FD capability up to 2 Mbit/s, and an 8-pin PG-TSON-8-1 footprint. Confirm that ISO 11898-2 compatibility, node count, common-mode range, and thermal limits match the vehicle or industrial network.
Is the TLE7250LEXUMA1 suitable for automotive ECUs?
Yes, the TLE7250LEXUMA1 is identified as an Infineon automotive CAN transceiver with AEC-Q100 qualification. Its 1 Mbit/s classical CAN capability and CAN FD support up to 2 Mbit/s suit electronic control units requiring an ISO 11898-2 physical-layer connection. Production use still requires verification of the exact temperature grade, EMC results, fault behavior, and manufacturer change notifications.
What are the key specifications of TLE7250LEXUMA1 that engineers should know?
The key TLE7250LEXUMA1 specifications are one half-duplex CAN channel, 5 V operation, a 1 Mbit/s maximum classical CAN data rate, CAN FD support up to 2 Mbit/s, ISO 11898-2 compatibility, AEC-Q100 automotive qualification, and an 8-pin PG-TSON-8-1 package. The exposed pad and tape-and-reel format also directly affect PCB layout and production handling.
What can replace the TLE7250LEXUMA1?
The TLE7250LE family designation is the closest confirmed alternative identification, while the TLE7257SJXUMA1 is a candidate that requires formal compatibility review. No verified cross-reference listing establishes five distinct, pin-to-pin drop-in alternatives for the exact PG-TSON-8-1 device. A valid replacement must match the land pattern, pin functions, 5 V supply, CAN data rate, common-mode range, fault behavior, and automotive qualification.

के लिए इंजीनियरिंग संदर्भ डेटा TLE7250LEXUMA1 — तुलना, डिज़ाइन मार्गदर्शन और अनुपालन जानकारी।

चयन गाइड

Choose the TLE7250LEXUMA1 for a 5 V, one-channel automotive CAN physical-layer design that uses ISO 11898-2, requires a 1 Mbit/s classical CAN rate, and may use CAN FD up to 2 Mbit/s. Its AEC-Q100 qualification and PG-TSON-8-1 exposed-pad package suit compact vehicle electronics requiring a defined automotive interface. The TLE7250LE family designation is appropriate when a broader family-level evaluation is being performed, but the ordering suffix must still be confirmed. Treat the TLE7257SJXUMA1 as a comparison candidate rather than an automatic substitution: its mode-control, supply-current, pin-function, and qualification differences require review. No other cross-brand drop-in part should be released without a manufacturer-supported pin-to-pin cross-reference and verification of CAN timing, common-mode limits, fault behavior, temperature range, and EMC performance.

विकल्पों के साथ तुलना

पैरामीटर यह उत्पाद TLE7250LE TLE7257SJXUMA1
Brand Infineon Technologies Infineon Technologies Infineon Technologies
Package PG-TSON-8-1 PG-TSON-8-1 PG-TSON-8-1
Product Type Automotive CAN transceiver Automotive CAN transceiver Automotive CAN transceiver

मुख्य विशेषताएँ

  • Supports both classical CAN and CAN FD (बनामTLE7250LE)
  • Automotive qualification and functional safety support (बनामTLE7257SJXUMA1)
  • Compact exposed-pad implementation (बनामTLE7257SJXUMA1)

डिज़ाइन नोट्स

Route CAN_H and CAN_L as a controlled differential pair from the transceiver to the bus connector. Minimize branch stubs and keep the pair length balanced. Place termination only at locations defined by the network topology; incorrect termination can load the bus and impair communication at the device's 1 Mbit/s classical CAN capability.

Implement the exposed pad using the manufacturer's PG-TSON-8-1 land pattern and an adequate ground plane. The pad provides the primary thermal path from the device, so avoid cutting it away with isolated board-routing rules. Confirm actual junction temperature and copper area with the thermal information in the current Infineon datasheet before finalizing the board.

Do not treat the transceiver as a complete CAN controller. A compatible CAN protocol controller is required for arbitration, framing, acknowledgements, error handling, and diagnostics. Also verify that 5 V supply tolerances, transceiver mode settings, bus common-mode range, and the controller's CAN FD capability agree before enabling operation above 1 Mbit/s.

Keep the CAN interface physically separated from noisy power-conversion stages and high-speed digital clocks. Use a continuous ground reference and short supply-decoupling path. Infineon describes the TLE7250LE family as having low EME/EMI characteristics, but system-level electromagnetic performance still depends on PCB layout, harness construction, filtering, and the chosen bus topology.

अनुपालन जानकारी

RoHS
Compliant
REACH
Unknown
AEC-Q100
Qualified
लीड फ्री
Unknown
हैलोजन फ्री
Unknown
कॉन्फ्लिक्ट मिनरल्स
Unknown

The product listing identifies the TLE7250LEXUMA1 as an AEC-Q100-qualified automotive CAN transceiver. RoHS compliance is stated by the listing; other environmental and material declarations require confirmation from the manufacturer.

डेटा सत्यापन तिथि: 2026-11-04 — डेटा XAIPART की कंपोनेंट इंजीनियरिंग टीम द्वारा सत्यापित और क्यूरेट किया गया

संबंधित खोजें

TLE7250LEXUMA1 datasheet TLE7250LEXUMA1 datasheet pdf TLE7250LEXUMA1 pinout TLE7250LEXUMA1 equivalent TLE7250LEXUMA1 replacement TLE7250LEXUMA1 price TLE7250LEXUMA1 stock Infineon TLE7250LEXUMA1 TLE7250LEXUMA1 PG-TSON-8-1 TLE7250LEXUMA1 1 Mbit/s CAN TLE7250LEXUMA1 automotive CAN transceiver TLE7250LE vs TLE7250LEXUMA1

संबंधित कंपोनेंट्स और शब्द

Infineon Technologies TLE7250LEXUMA1 TLE7250LE TLE7257SJXUMA1 CAN transceiver CAN interface IC physical-layer transceiver Controller Area Network HS CAN CAN FD ISO 11898-2 5 V supply 1 Mbit/s 2 Mbit/s half duplex AEC-Q100 PG-TSON-8-1 TSON package exposed pad surface mount CAN_H CAN_L automotive electronics industrial automation EMI EMC
त्वरित क़ौतिल आदेश (RFQ)
पूर्ण विवरण भरें — हमारी सेल्स टीम 24 घंटे के भीतर जवाब देगी
पार्ट नंबर निर्माता पैकेज QTY लक्ष्य कीमत विस्तारित
✓
उद्धरण प्रस्तुत!

हम आपकी ईमेल पर 24 घंटे के भीतर जवाब देंगे

1
RFQ सबमिट किया गया
2
कोटेशन प्राप्त हुआ
3
ऑर्डर हो गया
4
भुगतान
5
शिप किया गया
6
डिलीवर किया गया
RFQ विवरण देखें