MPX4200A vs MPX4250A Perbandingan
Perbandingan bersamaan detil MPX4200A dari NXP Semiconductors dan MPX4250A dari NXP Semiconductors. Bandingkan spesifikasi penting, parameter listrik, pengemasan, status cycle, harga, dan ketersediaan untuk menentukan komponen terbaik untuk kebutuhan desain Anda.
Perbandingan Spesifikasi
| Parameter Umum | MPX4200A | MPX4250A |
|---|---|---|
| Merek | NXP Semiconductors | NXP Semiconductors |
| Kategori | Pressure Sensors | Pressure Sensors |
| Status Lingkungan Hidup | Aktif | NRND |
| Pressure Type | Absolute (Manifold Absolute Pressure) | — |
| Operating Pressure Range | 20 kPa to 200 kPa (2.9 PSI to 29.01 PSI) | 20 to 250 kPa absolute |
| Tipe Output | Analog voltage (ratiometric) | Analog, ratiometric to supply voltage |
| Rentang Tegangan Output | 0.3 V to 4.9 V | 0.2 V to 4.9 V (at 5.0 V supply) |
| Full-Scale Output (200 kPa) | 4.65 V typical at VCC = 5.1 V | — |
| Supply Voltage (VCC) | 5.1 V nominal (4.85 V to 5.35 V operating) | — |
| Arus Pemuat | 10 mA typical | [DATA_NEEDED: supply current at 5 V] |
| Pressure Error (0 °C to 85 °C) | 1.5 % maximum (full-scale) | — |
| Suhu Kerja | -40 °C to +125 °C | -40 C to +125 C |
| Storage Temperature | -40 °C to +125 °C | [DATA_NEEDED: storage temperature range] |
| Paket / Case | 6-SIP Module (through-hole) | 6-SIP Module |
| Port Type | Integrated axial pressure port | — |
| Tipe Mounting | Through Hole | Through Hole, SIP |
| Status RoHS | Compliant | Compliant (per NXP product page) |
| Signal Conditioning | On-chip, temperature compensated, calibrated | — |
| Tipe Pengukur | — | Manifold Absolute Pressure (MAP), sealed vacuum reference |
| Pressure Range | — | 20 kPa to 250 kPa (2.9 PSI to 36.3 PSI) |
| Maximum Overload Pressure | — | [DATA_NEEDED: maximum overload pressure] |
| Tegangan Pemuat | — | 4.85 V to 5.35 V (5.0 V typical) |
| Sensitivity | — | Approx. 18.4 mV/kPa (at Vsup = 5.0 V) |
| Response Time | — | 1.0 ms |
| Port Style | — | No port / non-port (basic element) |
| On-Chip Signal Conditioning | — | Yes (amplified, temperature-compensated, calibrated) |