TPS2054ADR vs TPS2054BDR Perbandingan
Perbandingan bersamaan detil TPS2054ADR dari Texas Instruments dan TPS2054BDR dari Texas Instruments. Bandingkan spesifikasi penting, parameter listrik, pengemasan, status cycle, harga, dan ketersediaan untuk menentukan komponen terbaik untuk kebutuhan desain Anda.
Texas Instruments
TPS2054BDR - Quad 500mA Current-Limited Power Switch | Texas Instruments
TPS2054BDR ✓ AktifPerbandingan Spesifikasi
| Parameter Umum | TPS2054ADR | TPS2054BDR |
|---|---|---|
| Merek | Texas Instruments | Texas Instruments |
| Kategori | Power Distribution Switches | Voltage Regulators |
| Status Lingkungan Hidup | Aktif | Aktif |
| Kanal | 4 | — |
| Fungsi | USB power-distribution switch (high-side) | — |
| Rentang Tegangan Masukan | 2.7 V to 5.5 V | 2.7 V to 5.5 V |
| Continuous Output Current per Channel | 0.5 A | — |
| Overcurrent Limit | 0.9 A | — |
| On-Resistance | 80 mOhm (typ) | — |
| Enable Logic | Active-high | — |
| Switch Type | N-channel MOSFET, high-side | N-Channel MOSFET (high-side) |
| Fault Protection | Overcurrent and thermal shutdown with auto-restart | — |
| Paket | 16-SOIC (0.154 in, 3.90 mm width) | SOIC-16 (D) |
| Tipe Mounting | Surface Mount | Surface Mount |
| Packaging | Tape & Reel (TR) | Tape and Reel (R suffix) |
| Kategori | PMIC - Power Distribution Switches, Load Drivers | — |
| Suhu Kerja | [DATA_NEEDED: operating temperature range] | [DATA_NEEDED: operating temperature range] |
| Status RoHS | Compliant | Lead Free / RoHS compliant per distributor listing |
| Arus Memerintah | [DATA_NEEDED: quiescent current] | [DATA_NEEDED: quiescent current] |
| Topologi | — | Quad-channel high-side power-distribution switch (1:1) |
| Number of Channels | — | 4 |
| On-Resistance (RDS(on)) | — | 70 mOhm |
| Continuous Output Current | — | 500 mA per channel |
| Current Limit (Minimum) | — | 0.75 A |
| Current Limit (Maximum) | — | 1.25 A |
| Output Rise Time | — | 0.6 ms (typical) |
| Protection Features | — | Thermal shutdown, short-circuit protection, undervoltage lockout |
| Fault Reporting | — | Deglitched overcurrent (OC) flag |
| Enable Input | — | Yes (active-high EN) |