AD7711AR - 24-Bit Sigma-Delta ADC | Analog Devices | RTD
MPN: AD7711AR ✓ AktifAD7711AR Ringkasan
A sigma-delta ADC is an analog-to-digital converter that oversamples its input and uses digital filtering and noise shaping to provide high resolution. Within the signal-chain hierarchy, the AD7711AR is a signal-conditioning ADC in the integrated-circuits category, combining analog input conditioning, programmable conversion functions, and serial digital output. This makes it suitable for resistance, temperature, pressure, and other slow-moving transducer measurements where low noise is more important than high sampling bandwidth.
The AD7711 provides matched current sources for RTD excitation, reducing excitation-related error in resistance temperature detector measurements. Its two analog inputs allow a primary measurement channel and an auxiliary or reference measurement to be handled by the same converter. Digital calibration and system-calibration capabilities improve offset, gain, and full-scale accuracy, while selectable output data rates let the design trade measurement speed against noise performance.
The sigma-delta architecture emphasizes resolution and noise performance at low frequencies rather than high throughput. Serial interface signals reduce the number of data pins required, and the 24-pin SOIC package supports conventional PCB assembly. The differential reference arrangement allows the converter to track reference voltage changes, which is important when a sensor and ADC share a precision reference. Digital filtering further reduces high-frequency noise after conversion.
Typical applications include industrial RTD temperature measurement, thermocouple instrumentation, bridge-based pressure and force sensing, process-control monitoring, and laboratory measurement systems. In an RTD circuit, the matched excitation currents minimize errors caused by unequal current sources, while the differential input rejects common-mode voltage present on sensor wiring. The auxiliary channel can periodically monitor another voltage or support reference-related diagnostics.
Design the analog input and reference paths for low noise, use a clean analog supply and reference source, and follow the manufacturer pin-description table when assigning PCB tracks. Select the output-data-rate and digital-filter settings according to the required settling time; faster rates generally reduce conversion time but increase noise. The 24-pin SOIC footprint requires attention to thermal layout when operating near its full specified supply range.
This page organizes the AD7711AR specifications, pricing workflow, application guidance, and verified drop-in alternatives in one engineering-focused reference. It also identifies which details should be checked against the manufacturer datasheet before layout release, helping engineers evaluate the device across industrial instrumentation and precision sensor-measurement systems.
Alternatif penggantian untuk AD7711AR — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.
Variasi di dalam seri ini
Model-series yang sama yang kompatibel dengan penggantian AD7711AR (sama faktor bentuk dan footprint) — berbeda di dalam Package, Resolution.
AD7710AR
✅ Drop-InKontak untuk harga
Lihat Datasheet →AD7714AR-5
✅ Drop-In📋 Alternatif referensi (tidak dalam katalog)
AD7711AR Rating Maksimal & Karakteristik Listrik
| Converter Type | 24-bit sigma-delta ADC |
| Manufacturing Status | Production CMOS |
| Analog Input Configuration | 1 differential input and 1 single-ended input |
| Reference Input | Differential reference input |
| RTD Excitation | Matched RTD excitation currents |
| Output Data Format | Serial digital word |
| Maximum Conversion Rate | 19.5 kSPS |
| Resolusi | 24 bit |
| Input Channels | 2 inputs |
| Digital Interface | Serial interface |
| Paket | 24-pin SOIC |
| Tipe Mounting | Surface mount |
AD7711AR 24-pin soic Diamant Konfigurasi Panduan
Konfigurasi pin untuk AD7711AR (24-pin soic pakai pakai). Komponen analog ini memiliki pin masukan, keluaran, dan pengirim daya. Lihat datasheet produsen untuk konfigurasi pin offset null, kompensasi, dan pengaktifan. Ideal untuk peralatan sinyal dan kabel penggandaran.
Tidak ada data diatribut pin yang tersedia untuk AD7711AR.
Lihat ke: datasheet produk untuk konfigurasi pin penuh.
Aplikasi Umum
AD7711AR cocok untuk 6 aplikasis: Industrial RTD Temperature Measurement, Thermocouple Instrumentation, Bridge-Based Pressure Sensing, Process-Control Monitoring, Laboratory Instrumentation, Force and Load Measurement.
Industrial RTD Temperature Measurement
The AD7711AR fits industrial RTD temperature measurement because its matched excitation currents and differential analog input are designed for low-level resistance signals. The converter can apply excitation to the sensor while measuring the resulting differential voltage, reducing sensitivity to unequal current-source error and common-mode voltage on the wiring. Its 24-bit sigma-delta architecture and selectable conversion behavior suit slowly changing temperature. Design the input network and reference source for low noise, then configure the digital filter and output rate to meet the required update interval.
Direkomendasikan
Thermocouple Instrumentation
The AD7711AR can support thermocouple instrumentation when the selected input range and calibration procedure match the thermocouple output. A 24-bit converter provides high numerical resolution for slow-changing millivolt-level signals, while the differential input helps reject voltage common to both measurement nodes. System calibration is important because offset and gain errors directly affect temperature accuracy. Use an appropriate cold-junction compensation arrangement, protect the input path, and review the manufacturer's input-span and filtering guidance before selecting the conversion rate.
Direkomendasikan
Bridge-Based Pressure Sensing
The AD7711AR is suitable for pressure sensors that use a resistive bridge because the bridge output is small, differential, and normally changes slowly. The ADC's 24-bit resolution preserves fine measurement detail, while differential input reduces sensitivity to common supply and ground shifts. The auxiliary single-ended input can support periodic auxiliary-voltage measurement when the system requires it. The bridge excitation source should have low noise and adequate stability, and the PCB should keep sensor wiring short and symmetric to minimize pickup and additional imbalance.
Direkomendasikan
Process-Control Monitoring
The AD7711AR can serve as the acquisition element in process-control monitoring where temperature, pressure, flow, or level sensors produce low-frequency differential signals. Its 24-bit sigma-delta conversion provides detailed digital results for calibration, logging, and closed-loop control. Matched RTD excitation currents are particularly useful for resistance-based sensing, and the serial interface allows the converter to operate alongside a controller or embedded system. Choose the data rate and digital filter for the control-loop update requirement, then verify total conversion time rather than relying only on the maximum sample rate.
Direkomendasikan
Laboratory Instrumentation
The AD7711AR is well suited to laboratory instruments that measure resistance, temperature, or low-level differential voltages with high resolution. The 24-bit sigma-delta architecture favors accuracy over high-frequency sampling, making it useful for laboratory sources, meters, and data-acquisition front ends. The differential reference input allows tracking of a precision reference, and calibration functions can reduce offset and gain errors. Shield sensitive analog traces, use a low-noise reference, and select filtering settings that provide sufficient settling time for the measurement sequence.
Direkomendasikan
Force and Load Measurement
The AD7711AR can be used with strain-gauge or load-cell front ends where the physical quantity appears as a small differential voltage. High converter resolution supports slow force measurements, and differential sensing helps reject common-mode excitation and ground-bounce effects. Because the sensor output is sensitive to excitation accuracy and reference stability, the excitation and reference arrangements require careful grounding and filtering. A shielded analog section, symmetric routing, and system calibration are essential. The part's 24-bit result supports high-resolution force records without requiring a high-bandwidth converter.
Direkomendasikan
Ringkasan Produk Direkomendasikan
Data referensi engineering untuk AD7711AR — pembandingan, panduan desain, dan informasi konformitas.
Panduan Pemilihan
Pembandingan dengan Alternatif
| Parameter Umum | Produk Ini | AD7710AR | AD7714AR-5 |
|---|---|---|---|
| Package | 24-pin SOIC | 24-pin SOIC | 24-pin SOIC |
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Converter Architecture | 24-bit sigma-delta ADC | 24-bit sigma-delta ADC | Sigma-delta ADC |
| Output Interface | Serial digital output | Serial interface | Serial interface |
| Primary Application | Low-frequency transducer and RTD measurement | Precision low-frequency measurement | Precision sensor measurement |
Diferensiator Kunci
- Integrated matched excitation currents for resistance sensors (vsAD7710AR)
- Dedicated differential and auxiliary analog inputs (vsAD7710AR)
- High-resolution conversion for low-frequency signals (vsAD7714AR-5)
Catatan Desain
Route the analog input, reference, and excitation paths as short, symmetric traces with a continuous ground plane. Keep switching-regulator traces, digital clocks, and high-current return paths away from the sensor inputs. Differential pairs should be matched in length and geometry, and the analog ground and digital-ground connections should follow the manufacturer's grounding guidance.
Use a low-noise, stable reference and decouple the analog and digital supply pins close to the device. Because the sigma-delta architecture filters noise digitally, input filtering should not unintentionally create a long settling time at the selected output data rate. Review the digital-filter selection and total conversion time before increasing the rate in a precision RTD or bridge measurement.
Do not substitute a converter solely because it is described as a 24-bit ADC. Verify the exact 24-pin SOIC pin functions, reference topology, input range, excitation capability, serial timing, supply limits, and calibration workflow. In particular, the AD7711AR's matched RTD excitation currents cannot be assumed to exist on a generic AD771x-family alternative.
Separate the precision analog-supply path from noisy digital loads and verify the supply currents in the manufacturer electrical-characteristics table. Decoupling capacitors should be placed at the relevant supply pins with short ground returns. For an RTD measurement, the excitation source, reference source, and ADC input network must be evaluated together because their errors can appear as measurement gain or offset error.
Informasi Konformitas
The AD7711 product page identifies the device as production CMOS, but the retrieved content does not state the exact RoHS, REACH, lead-free, halogen-free, or conflict-minerals status for AD7711AR.