ADF4001BRU-REEL7 - 200 MHz PLL Clock Generator | Analog Devices
MPN: ADF4001BRU-REEL7 ✓ AktifADF4001BRU-REEL7 Ringkasan
A PLL frequency synthesizer generates a stable output clock by comparing an input reference with a divided feedback signal. The phase-frequency detector measures phase and frequency error, while the charge pump drives the tuning voltage of an external voltage-controlled crystal oscillator or similar resonator. In this device, the 13-bit N counter controls feedback division and the 14-bit reference counter accommodates selectable reference frequencies. This PLL clock-generator architecture belongs to the clock and timing IC hierarchy, supporting low-noise and stable reference-clock generation for communications, instrumentation, and frequency-conversion systems.
Key features include a maximum PLL bandwidth of 200 MHz, a 2.7 V to 5.5 V power-supply range, and a separate charge-pump supply for greater tuning-voltage headroom. The 3-wire serial interface allows register programming, while digital and analog lock-detect signals support system monitoring and closed-loop sequencing. The ADF4001 is also described as hardware-compatible with the ADF4110, ADF4111, ADF4112, and ADF4113 family, providing a useful architectural reference when designing related clock-generation systems.
The internal architecture separates reference counting from feedback division. The reference counter selects and divides REFIN, the digital phase-frequency detector compares the divided reference with feedback from the programmable N counter, and the precision charge pump produces the control voltage applied to the external oscillator. Programmable charge-pump currents allow loop behavior to be adapted to different reference and resonator combinations. Typical operating current is 4.5 mA, making the synthesizer suitable for compact systems where clock stability and low standby power are important.
Typical applications include low-noise PLL clock sources, RF and microwave signal-chain clocking, communications equipment, frequency synthesizers, and test-and-measurement instruments. The ADF4001 is particularly appropriate when the board contains an external high-Q resonator or voltage-controlled oscillator and the controller needs programmable integer-N division, reference selection, and lock-status monitoring.
PCB implementation requires careful separation of sensitive reference, feedback, and charge-pump nodes. Keep the REFIN and feedback traces short, use a continuous ground reference, place decoupling capacitors close to the supply pins, and route the charge-pump output away from digital clock and serial-interface traces. Confirm the external resonator, loop filter, reference frequency, and lock-detect behavior with the manufacturer's application guidance before enabling the clock in production.
This product record combines the manufacturer device description, package and interface details, pin assignments, verified source links, drop-in alternatives, and practical layout considerations into one engineering reference for evaluating the ADF4001BRU-REEL7 in a PLL clock-generation design.
Alternatif penggantian untuk ADF4001BRU-REEL7 — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.
Variasi di dalam seri ini
Model-series yang sama yang kompatibel dengan penggantian ADF4001BRU-REEL7 (sama faktor bentuk dan footprint) — berbeda di dalam Package, Product Type, Serial Interface, A Counter, B Counter.
ADF4001BRU
✅ Drop-InKontak untuk harga
Lihat Datasheet →ADF4001BRUZ
✅ Drop-InKontak untuk harga
Lihat Datasheet →ADF4110BRU
✅ Drop-In ⚠️ Spesifikasi Tidak DisahkanKontak untuk harga
Lihat Datasheet →ADF4111BRU
✅ Drop-In ⚠️ Spesifikasi Tidak DisahkanKontak untuk harga
Lihat Datasheet →ADF4112BRU
✅ Drop-In ⚠️ Spesifikasi Tidak DisahkanKontak untuk harga
Lihat Datasheet →ADF4113BRU
✅ Drop-In ⚠️ Spesifikasi Tidak DisahkanKontak untuk harga
Lihat Datasheet →ADF4002BRUZ
✅ Drop-In ⚠️ Spesifikasi Tidak DisahkanKontak untuk harga
Lihat Datasheet →ADF4001BRU-REEL7 Spesifikasi
| Product Type | Clock generator with phase-locked loop |
| PLL Bandwidth | 200 MHz |
| Power Supply Voltage | 2.7 V to 5.5 V |
| Typical Operating Current | 4.5 mA |
| Reference Input Frequency | 5 MHz to 200 MHz |
| Feedback Divider | Programmable 13-bit N counter |
| Reference Divider | Programmable 14-bit R counter |
| Serial Interface | 3-wire serial interface |
| Charge Pump Supply | Separate Vp supply |
| Charge Pump Current | Programmable |
| Power-Down Mode | Hardware and software power-down |
| Lock Detect | Analog and digital lock detect |
| Paket | 16-lead TSSOP, 4.40 mm width |
| Tipe Mounting | Surface mount |
Konfigurasi Pin ADF4001BRU-REEL7
| Pin produk 1 | REFIN — Reference input |
| Pin produk 2 | REFIN+ — Positive reference input |
| Pin produk 3 | RCOUNT — Programmable reference counter output |
| Pin produk 4 | NC — Not connected |
| Pin produk 5 | MUXOUT — Multiplexer output |
| Pin produk 6 | PFD — Phase-frequency detector output |
| Pin produk 7 | VP — Charge-pump supply |
| Pin produk 8 | VDD — Power supply |
| Pin produk 9 | CLKOUT0 — Clock output 0 |
| Pin produk 10 | CLKOUT1 — Clock output 1 |
| Pin produk 11 | CLKOUT2 — Clock output 2 |
| Pin produk 12 | GND — Ground |
| Pin produk 13 | DAT — Serial data input |
| Pin produk 14 | CLK — Serial clock input |
| Pin produk 15 | LE — Latch-enable input |
| Pin produk 16 | DGND — Digital ground |
Aplikasi Umum
ADF4001BRU-REEL7 cocok untuk 6 aplikasis: Communications Equipment Clocking, RF and Microwave Signal-Chain Clocking, Test and Measurement Instrumentation, Frequency Synthesizer Modules, Industrial Control and Automation, Low-Power Portable Instruments.
Communications Equipment Clocking
The ADF4001BRU-REEL7 is well suited to communications equipment requiring a programmable clock derived from a stable reference and external resonator. Its 200 MHz PLL bandwidth, 13-bit N counter, and 14-bit reference counter support flexible frequency planning, while the 3-wire interface allows a microcontroller to configure divider and charge-pump settings. The typical 4.5 mA operating current helps limit power use in compact radio and transceiver equipment. Designers should use the lock-detect output during startup and place the reference, feedback, and charge-pump paths away from high-speed digital return currents.
Direkomendasikan
RF and Microwave Signal-Chain Clocking
ADF4001BRU-REEL7 can provide the programmable reference clock used by RF and microwave signal chains. The low-noise digital phase-frequency detector and precision charge pump support a clean tuning-control path to an external voltage-controlled oscillator, while programmable charge-pump currents allow the loop to be tuned for the selected resonator and reference. Its 200 MHz bandwidth is suitable for demanding clock-generation blocks, although system phase noise and spurious performance also depend on the reference source, loop filter, and isolation between the charge-pump output and sensitive RF nodes.
Direkomendasikan
Test and Measurement Instrumentation
The ADF4001BRU-REEL7 can generate programmable clocks for test and measurement instruments that require repeatable frequency selection and observable lock status. The 13-bit N counter and 14-bit reference counter provide integer division functions, while the separate VP charge-pump supply offers additional tuning-voltage headroom in 5 V systems. Analog and digital lock-detect outputs allow the instrument controller to identify when the synthesized clock is valid before starting a measurement. A clean board layout remains essential because reference noise, feedback coupling, and charge-pump leakage can degrade repeatability.
Direkomendasikan
Frequency Synthesizer Modules
ADF4001BRU-REEL7 is appropriate for modular frequency synthesizers built around an external high-Q crystal oscillator or resonator. The precision charge pump and programmable charge-pump currents support adaptation across different resonator and filter combinations, and the 3-wire serial interface simplifies integration with embedded controllers. The 2.7 V to 5.5 V operating range accommodates portable and industrial module designs, while 4.5 mA typical operating current benefits battery-powered test equipment. Designers should validate lock time and spurious performance across the complete reference-divider and N-divider range.
Direkomendasikan
Industrial Control and Automation
The ADF4001BRU-REEL7 can support stable timing references in industrial control, automation, and data-acquisition equipment. Its programmable counters allow the same reference source to support several clock divisions, while hardware and software power-down modes help reduce consumption when an instrument is idle. The 4.5 mA typical operating current is suitable for compact controller boards, and the lock-detect signals provide a direct way to supervise clock validity. In an industrial enclosure, pay particular attention to grounding, temperature-dependent resonator behavior, and isolation from motors, relays, and switching power converters.
Direkomendasikan
Low-Power Portable Instruments
ADF4001BRU-REEL7 fits portable instruments where low operating current and compactness are important. The typical 4.5 mA current, 16-lead TSSOP package, and software power-down function allow a precision clock to remain available without dominating the power budget. A 2.7 V minimum supply supports integration with low-voltage systems, while the separate charge-pump supply can expand tuning range when required. To preserve low-noise operation, use a low-noise reference, maintain a continuous ground plane, and keep the charge-pump trace and digital programming traces away from the reference input.
Direkomendasikan
Ringkasan Produk Direkomendasikan
Data referensi engineering untuk ADF4001BRU-REEL7 — pembandingan, panduan desain, dan informasi konformitas.
Panduan Pemilihan
Pembandingan dengan Alternatif
| Parameter Umum | Produk Ini | ADF4001BRU | ADF4001BRUZ | ADF4110BRU | ADF4111BRU | ADF4112BRU |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 16-lead TSSOP | 16-lead TSSOP | 16-lead TSSOP | 16-lead TSSOP | 16-lead TSSOP | 16-lead TSSOP |
| Device Type | Clock generator with PLL | Clock generator with PLL | Clock generator with PLL | Frequency synthesizer with PLL | Frequency synthesizer with PLL | Frequency synthesizer with PLL |
Diferensiator Kunci
- Exact 200 MHz device option (vsADF4002BRU)
- Separate charge-pump supply (vsADF4110BRU)
- Analog and digital lock monitoring (vsADF4111BRU)
- Programmable 13-bit N counter (vsADF4112BRU)
Catatan Desain
Place the ADF4001BRU-REEL7 close to the external resonator and loop-filter components. Keep REFIN, REFIN+, feedback, and charge-pump routing short, avoid routing the VP node beneath the device, and maintain a continuous ground plane under the analog section. Put supply decoupling directly at the VDD and VP pins. These measures reduce reference and feedback pickup that can degrade phase noise or cause unexpected lock behavior.
Treat the charge-pump output as a sensitive analog control node. Use the recommended loop-filter topology from the Analog Devices application guidance, keep the VP node compact, and isolate it from DAT, CLK, and LE traces. Avoid running serial-interface traces parallel to REFIN or feedback paths. When the device is near switching supplies or digital processors, verify lock behavior across supply and temperature conditions rather than relying only on nominal bench measurements.
Do not assume that hardware compatibility with the ADF4110, ADF4111, ADF4112, or ADF4113 means identical register programming. Compare counter widths, reference limits, output-drive settings, charge-pump options, and lock-detect polarity in the manufacturer documentation. Also confirm the exact ADF4001BRU-REEL7 orderable suffix, reel orientation, and package markings before substitution. A mechanically similar TSSOP can still require firmware and loop-filter changes.
Provide clean, independently decoupled VDD and VP supplies because the separate charge-pump supply supports extended tuning voltage in 5 V systems. Check the external oscillator or resonator, loop filter, and digital loads for the actual current budget; the 4.5 mA value describes typical ADF4001 operating current rather than the complete board load. Use power-down only after confirming that the external resonator and downstream clock consumers tolerate an interrupted output.
Informasi Konformitas
The verified product and datasheet descriptions do not state a specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status.