ADM3488EARZ - 3.3V 250kbps Full-Duplex RS-485/RS-422 | Analog Devices
MPN: ADM3488EARZ ✓ AktifADM3488EARZ Ringkasan
An RS-485/RS-422 transceiver is a physical-layer interface IC that converts logic-level signals into balanced differential signals for reliable communication over longer, noise-prone conductors. RS-422 is commonly used for point-to-point, full-duplex links, while RS-485 supports multipoint buses and can also operate in full-duplex wiring when separate differential pairs are available. Within the interface hierarchy, the ADM3488EARZ belongs to the RS-485/RS-422 transceiver class of data-communication semiconductor devices.
The ADM3488EARZ provides ±15 kV ESD protection, a 250 kbps maximum signaling rate, a 3.0 V to 3.6 V operating range, and approximately 2.2 mA supply current. Its receiver features a fail-safe design, produces a high-impedance output when disabled or unpowered, and accepts a common-mode input range from -7 V to +12 V. A shutdown function helps reduce power consumption in systems that do not require continuous bus activity.
The device uses slew-rate-limited signaling to reduce unwanted reflections and electromagnetic interference on balanced lines. Its industry-standard 75176 pinout supports straightforward board-level replacement when the original component, voltage rating, data rate, and protection requirements match. The fail-safe receiver behavior improves system robustness when a driver is disconnected or a bus line becomes idle, while the common-mode range allows the receiver to remain functional in industrial environments with ground-potential differences.
Typical uses include industrial control networks, building-automation equipment, instrumentation links, industrial sensors, data acquisition systems, and embedded serial buses. The full-duplex architecture is particularly useful when transmit and receive paths require independent differential pairs. It can also be used in point-to-point RS-422 links or in full-duplex RS-485 installations where four conductors are available for the two bus directions.
For PCB implementation, follow the manufacturer's recommended decoupling, protection, and bus-layout practices. Place the supply capacitor close to VCC, maintain a continuous ground reference beneath the signal interface, route differential pairs with consistent impedance and spacing, and provide suitable termination at the physical ends of the bus. Avoid adding excessive capacitance to long cables because it can degrade edge rate and upset the transceiver's 250 kbps capability.
This page provides an engineering-oriented overview of the ADM3488EARZ, compares it with relevant drop-in options, and consolidates interface, protection, layout, and replacement guidance. It also highlights the device's role in robust balanced-data communication, helping designers distinguish electrical compatibility from simple package similarity before approving a substitution.
Alternatif penggantian untuk ADM3488EARZ — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.
Variasi di dalam seri ini
Model-series yang sama yang kompatibel dengan penggantian ADM3488EARZ (sama faktor bentuk dan footprint) — berbeda di dalam Package, Maximum Data Rate, Driver Count, Product Type, Receiver Count.
ADM3488ARZN
✅ Drop-InKontak untuk harga
Lihat Datasheet →ADM3490ARZ
✅ Drop-InKontak untuk harga
Lihat Datasheet →ADM3488ARZN
✅ Drop-InKontak untuk harga
Lihat Datasheet →MAX3488ECSA+
✅ Drop-InKontak untuk harga
Lihat Datasheet →SN65HVD888D
✅ Drop-In📋 Alternatif referensi (tidak dalam katalog)
ADM3488EARZ Spesifikasi
| Product Type | RS-485/RS-422 differential transceiver |
| Supply Voltage Range | 3.0 V to 3.6 V |
| Nominal Supply Voltage | 3.3 V |
| Maximum Data Rate | 250 kbps |
| Duplex Mode | Full duplex |
| Driver Count | 1 |
| Receiver Count | 1 |
| Receiver Output | Tri-state |
| ESD Protection | ±15 kV |
| Arus Pemuat | 2.2 mA |
| Common-Mode Input Range | -7 V to +12 V |
| Rentang Suhu Kerja | -40°C to +85°C |
| Paket | 8-lead SOIC |
| Tipe Mounting | Surface mount |
| Receiver Fail-Safe | Open-circuit fail-safe |
| Powered-Off Receiver Output | High impedance |
| Slew Rate | Limited |
| Status RoHS | Compliant |
| Shutdown Function | Yes |
| Driver and Receiver Count | 1 driver and 1 receiver |
Konfigurasi Pin ADM3488EARZ
| Pin produk 1 | RO — Receiver output |
| Pin produk 2 | /RE — Active-low receiver enable |
| Pin produk 3 | DE — Driver enable |
| Pin produk 4 | DI — Driver data input |
| Pin produk 5 | GND — Ground |
| Pin produk 6 | A/Y — Driver output A or inverting receiver input |
| Pin produk 7 | B/Z — Driver output B or noninverting receiver input |
| Pin produk 8 | VCC — Positive supply |
Aplikasi Umum
ADM3488EARZ cocok untuk 6 aplikasis: Industrial RS-485 Control Networks, Point-to-Point RS-422 Data Links, Building Automation and HVAC Equipment, Data Acquisition and Instrumentation, Industrial Sensor and Actuator Nodes, Embedded Communication Port.
Industrial RS-485 Control Networks
The ADM3488EARZ fits industrial control and monitoring nodes that communicate over balanced RS-485 wiring at rates up to 250 kbps. Its one-driver, one-receiver arrangement supports full-duplex operation when separate transmit and receive pairs are available, while the 3.0 V to 3.6 V supply range integrates readily with 3.3 V embedded controllers. The stated ±15 kV ESD protection improves interface robustness at connector-adjacent locations where cables can be handled or connected under uncontrolled conditions. The receiver's -7 V to +12 V common-mode input range accommodates moderate ground-potential differences between connected equipment. Bus reliability still depends on proper 120-ohm termination, controlled cable topology, protective grounding, and keeping stub branches short.
Direkomendasikan
Point-to-Point RS-422 Data Links
The ADM3488EARZ is appropriate for point-to-point RS-422 links that need simultaneous bidirectional communication and a compact 3.3 V interface. One driver handles the outgoing differential pair, while the separate receiver handles the incoming pair, allowing both directions to remain active without shared bus contention. A maximum data rate of 250 kbps suits moderate-speed command, status, and sensor-data links rather than high-bandwidth serial protocols. The slew-rate-limited output reduces edge aggressiveness on balanced wiring, and the fail-safe receiver helps establish a defined state if the connected driver becomes inactive. Use twisted-pair wiring, consistent impedance, common reference grounding, and endpoint termination to minimize reflections.
Direkomendasikan
Building Automation and HVAC Equipment
The ADM3488EARZ can connect a 3.3 V building-automation controller to balanced field-bus wiring used in HVAC, lighting-control, and environmental monitoring systems. Its 2.2 mA supply current suits compact controller boards, while full-duplex operation permits simultaneous command transmission and sensor-status reception when the wiring plan provides two differential pairs. The -40°C to +85°C operating range covers many indoor and enclosure environments. For long cable runs or installations with substantial ground offsets, verify the receiver common-mode range against the worst-case grounding condition and place surge protection near exposed connectors. The transceiver's ±15 kV ESD rating should not be treated as a substitute for a surge-protection network.
Direkomendasikan
Data Acquisition and Instrumentation
The ADM3488EARZ is useful in laboratory and field-instrumentation systems that exchange commands or measurement data over a balanced serial link. Its 250 kbps maximum data rate accommodates many sensor, status, and configuration channels without requiring a high-speed differential transceiver. The tri-state receiver output allows the receiver to remain disconnected when multiple devices share control of a bus, and the powered-off high-impedance behavior helps avoid contention during system transitions. Use the full-duplex inputs when continuous two-way communication is needed. Place the device near the connector or cable entry, route the differential pair away from switching nodes, and use a solid ground plane to reduce coupled noise and common-mode conversion.
Direkomendasikan
Industrial Sensor and Actuator Nodes
The ADM3488EARZ provides a compact differential interface for distributed sensors, remote actuators, and condition-monitoring nodes linked to a central controller. Its low 2.2 mA supply current is valuable in space- and power-constrained embedded modules, while the 3.3 V supply supports direct interfacing with modern microcontroller I/O. The fail-safe receiver provides a defined output condition for an open or idle input, improving state interpretation at the controller. The ±15 kV ESD rating adds useful protection for a node whose external cable is exposed to electrostatic discharge. Designers should still limit connector fault current, validate the common-mode range under worst-case grounding, and provide bus termination only where required by the cable topology.
Direkomendasikan
Embedded Communication Port
The ADM3488EARZ can add a robust balanced communication port to an embedded controller, gateway, or service module. At 250 kbps, it supports moderate-speed management and telemetry traffic while consuming approximately 2.2 mA from a 3.3 V rail. Full-duplex mode allows simultaneous command reception and response transmission over independent differential pairs, avoiding the need to time-share one bus. Its tri-state receiver permits controlled connection to shared signaling resources, and its shutdown mode supports additional power management. The 8-lead SOIC footprint simplifies routing compared with larger interface packages. During PCB layout, keep the differential trace pair continuous, avoid stubs, provide a solid ground reference, and place any external protection components close to the connector.
Direkomendasikan
Ringkasan Produk Direkomendasikan
Data referensi engineering untuk ADM3488EARZ — pembandingan, panduan desain, dan informasi konformitas.
Panduan Pemilihan
Pembandingan dengan Alternatif
| Parameter Umum | Produk Ini | ADM3488ARZ | ADM3490ARZ | MAX3488ECSA | SN65HVD888D |
|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Maxim Integrated | Texas Instruments |
| Package | 8-lead SOIC | 8-lead SOIC | 8-lead SOIC | 8-lead SOIC | 8-lead SOIC |
| Operating Supply | 3.0 V to 3.6 V | 3.3 V class | 3.3 V class | 3.3 V class | 3.3 V class |
Diferensiator Kunci
- Published ESD protection rating (vsADM3488ARZ)
- Wide receiver common-mode range (vsMAX3488ECSA)
- Full-duplex interface in an 8-lead SOIC (vsSN65HVD888D)
- Low-power 3.3 V operation (vsADM3490ARZ)
Catatan Desain
Route each differential pair as a tightly coupled pair over a continuous ground plane, maintaining uniform spacing and avoiding vias where possible. Keep the ADM3488EARZ close to the connector or cable entry so transient current can be redirected before reaching sensitive logic. Do not route the pair parallel to switching nodes, relays, or high-current power traces; this reduces capacitive coupling and common-mode conversion that can disrupt communication at the 250 kbps limit.
Place the recommended supply-decoupling capacitor immediately between VCC and GND, and provide a low-impedance ground return to the interface connector. The ADM3488EARZ operates from 3.0 V to 3.6 V and is listed at approximately 2.2 mA supply current. Keep transient and ESD-current paths away from the receiver input and logic ground so connector protection does not force noise through sensitive signal traces.
Do not assume that an 8-lead SOIC footprint alone makes another transceiver a drop-in replacement. Check enable polarity, receiver-output behavior, differential terminal names, shutdown state, common-mode range, and the exact 3.3 V electrical limits. Also verify the bus topology: full-duplex RS-422 uses separate pairs, while multipoint RS-485 generally requires a shared pair and careful placement of termination.
Use termination appropriate to the physical network and avoid placing unnecessary termination on every node. Long cables should use twisted-pair conductors and controlled impedance, while short stub branches should be minimized because their capacitance can reflect energy into the driver and reduce margin at the 250 kbps signaling rate. External protection devices should be placed close to the connector and selected to preserve the transceiver's intended logic levels and bandwidth.
Informasi Konformitas
The ADM3488EARZ is identified as RoHS compliant. No additional REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declarations were identified.