ADS7960SRHBT - 8-Bit 1MSPS 12Ch SAR ADC | Texas Instruments
MPN: ADS7960SRHBT ✓ AktifADS7960SRHBT Ringkasan
An SAR ADC is a type of analog-to-digital converter that uses a binary search algorithm to convert an analog input signal into a digital representation. It is known for its high speed and low power consumption, making it ideal for applications such as data acquisition, industrial process control, and portable instrumentation. The SAR architecture is widely used in multichannel systems where multiple analog signals need to be digitized sequentially.
Key features of the ADS7960SRHBT include a 1-MSPS sampling rate, 12 input channels, and a serial peripheral interface (SPI) for communication with microcontrollers or digital signal processors. The device operates from a single 2.7V to 5.25V power supply, and its micro-power consumption makes it suitable for battery-powered applications. The ADC also features a built-in reference and a programmable gain amplifier, reducing external component count.
The ADS7960SRHBT uses a capacitive DAC architecture with a successive approximation register, providing accurate conversion with low power dissipation. The device includes a track-and-hold circuit that samples the analog input, and the conversion result is output serially via the SPI interface. The ADC supports both single-ended and pseudo-differential input configurations, offering flexibility in system design.
Typical applications for the ADS7960SRHBT include data acquisition systems, industrial process control, motor control, and portable instrumentation. Its 12-channel input capability allows monitoring of multiple sensors or signals, while the SPI interface simplifies connection to a wide range of microcontrollers. The device is also suitable for battery-powered devices due to its low power consumption.
When designing with the ADS7960SRHBT, it is important to provide a clean analog supply and proper decoupling to achieve the specified performance. The reference input should be bypassed with a capacitor, and the analog input signals should be buffered if they have high source impedance. The SPI interface should be operated at the correct clock frequency to ensure accurate data transfer.
Alternatif penggantian untuk ADS7960SRHBT — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.
ADS7950SRHBT
✅ Drop-In📋 Alternatif referensi (tidak dalam katalog)
ADS7951SRHBT
✅ Drop-In ⚠️ Spesifikasi Tidak Disahkan📋 Alternatif referensi (tidak dalam katalog)
ADS7952SRHBT
✅ Drop-In ⚠️ Spesifikasi Tidak Disahkan📋 Alternatif referensi (tidak dalam katalog)
ADS7953SRHBT
✅ Drop-In ⚠️ Spesifikasi Tidak Disahkan📋 Alternatif referensi (tidak dalam katalog)
ADS7954SRHBT
✅ Drop-In ⚠️ Spesifikasi Tidak Disahkan📋 Alternatif referensi (tidak dalam katalog)
ADS7955SRHBT
✅ Drop-In ⚠️ Spesifikasi Tidak Disahkan📋 Alternatif referensi (tidak dalam katalog)
ADS7956SRHBT
✅ Drop-In ⚠️ Spesifikasi Tidak Disahkan📋 Alternatif referensi (tidak dalam katalog)
ADS7957SRHBT
✅ Drop-In ⚠️ Spesifikasi Tidak Disahkan📋 Alternatif referensi (tidak dalam katalog)
ADS7960SRHBT Rating Maksimal & Karakteristik Listrik
| Resolusi | 8 Bit |
| Laju Pengambilan Sampel | 1 MSPS |
| Number of Input Channels | 12 |
| Input Type | Single-Ended |
| Data Interface | Serial, SPI |
| Architecture | SAR |
| Paket / Case | 32-VQFN (5x5) |
| Suhu Kerja | -40°C to +125°C |
| Tegangan Pemuat | 2.7V to 5.25V |
| Power Consumption | MicroPower |
| Reference Type | Internal |
| Number of Conversions | 1 MSPS |
| Tipe Mounting | Surface Mount |
| Status RoHS | Compliant |
Konfigurasi Pin ADS7960SRHBT
| Pin produk 1 | AVDD — Analog power supply |
| Pin produk 2 | AVDD — Analog power supply |
| Pin produk 3 | CH0 — Analog input channel 0 |
| Pin produk 4 | CH1 — Analog input channel 1 |
| Pin produk 5 | CH2 — Analog input channel 2 |
| Pin produk 6 | CH3 — Analog input channel 3 |
| Pin produk 7 | CH4 — Analog input channel 4 |
| Pin produk 8 | CH5 — Analog input channel 5 |
| Pin produk 9 | CH6 — Analog input channel 6 |
| Pin produk 10 | CH7 — Analog input channel 7 |
| Pin produk 11 | CH8 — Analog input channel 8 |
| Pin produk 12 | CH9 — Analog input channel 9 |
| Pin produk 13 | CH10 — Analog input channel 10 |
| Pin produk 14 | CH11 — Analog input channel 11 |
| Pin produk 15 | GND — Ground |
| Pin produk 16 | GND — Ground |
| Pin produk 17 | SDO — Serial data output |
| Pin produk 18 | SDI — Serial data input |
| Pin produk 19 | SCLK — Serial clock input |
| Pin produk 20 | CS — Chip select (active low) |
| Pin produk 21 | REF — Reference voltage input |
| Pin produk 22 | REF — Reference voltage input |
| Pin produk 23 | DVDD — Digital power supply |
| Pin produk 24 | DVDD — Digital power supply |
| Pin produk 25 | GND — Ground |
| Pin produk 26 | GND — Ground |
| Pin produk 27 | NC — No connect |
| Pin produk 28 | NC — No connect |
| Pin produk 29 | NC — No connect |
| Pin produk 30 | NC — No connect |
| Pin produk 31 | NC — No connect |
| Pin produk 32 | NC — No connect |
Aplikasi Umum
ADS7960SRHBT cocok untuk 6 aplikasis: Data Acquisition Systems, Industrial Process Control, Motor Control, Portable Instrumentation, Battery Management Systems, Medical Monitoring.
Data Acquisition Systems
The ADS7960SRHBT is ideal for data acquisition systems that require monitoring multiple analog signals. With 12 single-ended input channels and a 1-MSPS sampling rate, it can digitize signals from sensors, transducers, and other analog sources. The SPI interface simplifies connection to microcontrollers, enabling efficient data transfer. Its micro-power consumption makes it suitable for portable data loggers and remote monitoring stations. The wide operating temperature range ensures reliable operation in harsh industrial environments.
Direkomendasikan
Industrial Process Control
In industrial process control, the ADS7960SRHBT can be used to monitor temperature, pressure, and flow sensors. Its 12 channels allow simultaneous sampling of multiple process variables, while the 1-MSPS speed enables fast response to changing conditions. The device's SPI interface allows easy integration with PLCs and industrial controllers. The -40°C to +125°C temperature range ensures reliable operation in factory floors and outdoor installations. The micro-power consumption reduces heat generation and energy costs in continuous monitoring applications.
Direkomendasikan
Motor Control
The ADS7960SRHBT is suitable for motor control applications where current and voltage sensing is required. Its 1-MSPS sampling rate allows accurate measurement of phase currents and bus voltages, enabling precise control of motor torque and speed. The 12 input channels can monitor multiple motor phases and auxiliary signals. The SPI interface provides fast data transfer to the motor controller, such as a DSP or MCU. The device's low power consumption is beneficial in battery-powered or energy-efficient motor drives.
Direkomendasikan
Portable Instrumentation
The ADS7960SRHBT is well-suited for portable instrumentation such as handheld multimeters, data loggers, and field analyzers. Its micro-power consumption extends battery life, while the 12 channels allow measurement of multiple signals. The small 5x5 mm VQFN package saves PCB space, enabling compact designs. The SPI interface allows easy connection to low-power microcontrollers. The wide operating temperature range ensures reliable operation in outdoor environments.
Direkomendasikan
Battery Management Systems
In battery management systems, the ADS7960SRHBT can monitor cell voltages and temperatures. Its 12 channels allow monitoring of multiple battery cells, while the 1-MSPS sampling rate enables fast voltage measurements. The SPI interface allows communication with the battery management controller. The device's low power consumption is critical for minimizing battery drain. The wide temperature range ensures accurate monitoring in various operating conditions.
Direkomendasikan
Medical Monitoring
The ADS7960SRHBT can be used in medical monitoring devices such as patient monitors and diagnostic equipment. Its 12 channels allow simultaneous acquisition of multiple physiological signals, such as ECG, EEG, and temperature. The 1-MSPS sampling rate is sufficient for most biomedical signals. The SPI interface enables integration with medical-grade microcontrollers. The device's low power consumption is essential for battery-operated portable medical devices. The wide temperature range ensures reliable operation in clinical environments.
Direkomendasikan
Ringkasan Produk Direkomendasikan
Data referensi engineering untuk ADS7960SRHBT — pembandingan, panduan desain, dan informasi konformitas.
Panduan Pemilihan
Pembandingan dengan Alternatif
| Parameter Umum | Produk Ini | ADS7950SRHBT | ADS7951SRHBT | ADS7952SRHBT | ADS7953SRHBT |
|---|---|---|---|---|---|
| Package | 32-VQFN (5x5) | 32-VQFN (5x5) | 32-VQFN (5x5) | 32-VQFN (5x5) | 32-VQFN (5x5) |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Resolution | 8 Bit | 10 Bit | 10 Bit | 10 Bit | 12 Bit |
| Sampling Rate | 1 MSPS | 1 MSPS | 1 MSPS | 1 MSPS | 1 MSPS |
| Number of Channels | 12 | 12 | 12 | 12 | 12 |
| Input Type | Single-Ended | Single-Ended | Single-Ended | Single-Ended | Single-Ended |
| Data Interface | SPI | SPI | SPI | SPI | SPI |
| Supply Voltage | 2.7V to 5.25V | 2.7V to 5.25V | 2.7V to 5.25V | 2.7V to 5.25V | 2.7V to 5.25V |
Diferensiator Kunci
- Higher resolution than ADS7960SRHBT (vsADS7950SRHBT)
- 12-bit resolution option (vsADS7953SRHBT)
- Pin-compatible family (vsOther ADCs)
Catatan Desain
Provide a clean analog supply (AVDD) and digital supply (DVDD) with proper decoupling. Use 0.1uF and 10uF capacitors close to the power pins. The reference input (REF) should be bypassed with a 1uF capacitor to ground to ensure stable reference voltage.
Place the ADC close to the analog signal sources to minimize trace length and reduce noise pickup. Use a solid ground plane and separate analog and digital ground planes if possible. Ensure the exposed thermal pad is soldered to the PCB for proper heat dissipation.
Avoid driving the analog inputs with high source impedance, as this can cause sampling errors. Use a buffer amplifier if the source impedance is high. Also, ensure the SPI clock frequency does not exceed the maximum specified in the datasheet to avoid data corruption.
Informasi Konformitas
RoHS compliant per TI product page. AEC-Q100 qualification not specified for this part.