Texas Instruments

DP83630SQX/NOPB - IEEE 1588 Ethernet PHY | Texas Instruments

MPN: DP83630SQX/NOPB ✓ Aktif
3 V to 3.6 V Vdss 48-WQFN (RHS) Package
MOQ: 1 |

DP83630SQX/NOPB Ringkasan

The Texas Instruments DP83630SQX/NOPB is an IEEE 1588 precision-time-protocol Ethernet PHY transceiver with a 48-WQFN (RHS) package measuring 7 mm by 7 mm. It operates from a 3 V to 3.6 V supply, supports MII and RMII host interfaces, and is specified for an industrial temperature range of -40 °C to 85 °C. The orderable suffix identifies the tape-and-reel industrial-temperature configuration.

An Ethernet PHY transceiver is the physical-layer interface between a digital host controller and copper network cabling. In the broader hierarchy, this device is an Ethernet transceiver, then a network interface IC, then an interface IC, and finally a semiconductor. The DP83630 adds IEEE 1588 precision-time-protocol functionality to the physical layer, supporting systems in which network communication and clock synchronization must be maintained together.

The principal benefits of the DP83630 are its compact 7 mm by 7 mm footprint, support for both MII and RMII host interfaces, and integration of IEEE 1588 timing functions into the Ethernet PHY. The 3 V to 3.6 V operating range suits 3.3 V network-interface designs, while the -40 °C to 85 °C rating covers industrial-temperature equipment. Its exposed-pad WQFN construction also provides a thermal path from the device to the PCB.

The DP83630 operates as the physical-layer endpoint between an Ethernet MAC and the external transformer or magnetics-based network interface. MII support provides a parallel interface for compatible MACs, while RMII reduces the number of host-side signals for more compact systems. IEEE 1588 precision-time support adds clock-related functionality without requiring a separate Ethernet PHY solely for synchronization. Exact timing accuracy, latency, jitter, media reach, and supported cable categories must be confirmed from the manufacturer datasheet for the final design.

Typical applications include industrial Ethernet controllers, synchronized automation equipment, networked measurement systems, factory-floor data acquisition, communications equipment, and embedded systems that require deterministic time transfer over Ethernet. The MII and RMII interfaces make the device relevant both to legacy parallel-interface designs and to compact RMII-based controllers. An MCU, MPU, FPGA, or dedicated Ethernet controller can provide the digital host side while the DP83630 manages the physical network connection.

Designers should verify the exact pin assignment, reference clock requirements, strap settings, media interface, magnetic-component selection, and recommended magnetic-isolation circuit against the manufacturer datasheet before layout. Keep the exposed pad connected to the recommended ground plane, place decoupling and support components close to their pins, and route high-speed signals with controlled impedance. Validation should include power sequencing, RMII timing margin, link establishment, and IEEE 1588 synchronization behavior across the intended network topology.

This product record combines the manufacturer ordering information, package and interface characteristics, comparison data, and practical implementation guidance. It is intended to help engineers identify the correct industrial Ethernet PHY configuration, assess replacement constraints, and plan the PCB and synchronization architecture before releasing a design for production.

Alternatif penggantian untuk DP83630SQX/NOPB — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.

DP83630SQ/NOPB

✅ Drop-In
Texas Instruments
📦 48-WQFN (RHS)
IEEE 1588 precision-time-protocol Ethernet PHY transceiver · 1 port · 10 Mbps and 100 Mbps · MII and RMII · 3.3 V · IEEE 1588 · Deterministic, low latency · 48-WQFN (7 x 7 mm)

Kontak untuk harga

Lihat Datasheet →

DP83630SQX/NOPB Spesifikasi

Product Type IEEE 1588 precision-time-protocol Ethernet PHY transceiver
Supported Network Protocol IEEE 1588 precision-time protocol
Host Interface MII and RMII
Number of Drivers/Receivers 1/1
Supply Voltage Range 3 V to 3.6 V
Rentang Suhu Kerja -40 °C to 85 °C
Paket 48-WQFN (RHS)
Package Body Size 7 mm × 7 mm
Jumlah Pin 48 pins
Tipe Mounting Surface mount
Temperature Grade Industrial
Shipping Format Tape and reel
Product Status Active
AEC-Q100 Qualification Not applicable

DP83630SQX/NOPB 7 mm × 7 mm Diamant Konfigurasi Panduan

Konfigurasi pin untuk DP83630SQX/NOPB (7 mm × 7 mm pakai pakai). Penomoran pin, fungsi, dan diagram koneksi ditetapkan dalam datasheet produsen. Lihatnya untuk footprint dan pedoman perpindahan paruh.

Diamant diagram pakai pakai 7 mm × 7 mm untuk DP83630SQX/NOPB

Tidak ada data diatribut pin yang tersedia untuk DP83630SQX/NOPB.

Lihat ke: datasheet produk untuk konfigurasi pin penuh.

Aplikasi Umum

DP83630SQX/NOPB cocok untuk 6 aplikasis: Industrial Ethernet Automation, Precision Time-Synchronized Measurement, Factory Data Acquisition, Synchronized Robotics, Networked Communication Equipment, Embedded Control Systems.

🏭

Industrial Ethernet Automation

The DP83630SQX/NOPB fits industrial Ethernet automation because it combines a 1/1 Ethernet physical-layer transceiver with IEEE 1588 precision-time support. Its MII or RMII host connection allows a controller to implement the digital MAC side, while the 3 V to 3.6 V supply supports nominal 3.3 V interface designs. The -40 °C to 85 °C industrial temperature range suits equipment deployed across factory environments. IEEE 1588 support is particularly valuable when controllers, sensors, and actuators must share a common time reference over Ethernet. The final design should confirm clock-source requirements, MII or RMII timing, magnetics, isolation, and synchronization accuracy using the manufacturer datasheet.

📟

Precision Time-Synchronized Measurement

The DP83630SQX/NOPB is appropriate for measurement systems that require Ethernet communication and synchronized timing in the same physical-layer device. IEEE 1588 precision-time-protocol support allows network time information to be carried alongside normal Ethernet traffic, helping coordinate sampling across distributed instruments. The device’s MII and RMII interfaces provide flexibility between a parallel MAC implementation and a more compact host connection. With a 3 V to 3.6 V operating range and industrial temperature rating of -40 °C to 85 °C, it supports robust industrial test environments. Engineers should validate timing accuracy, jitter tolerance, reference-clock topology, and network calibration procedures against the system requirements.

📊

Factory Data Acquisition

The DP83630SQX/NOPB supports factory data-acquisition equipment that must move sensor and controller data over Ethernet while maintaining a common time base. A host processor can communicate through the PHY using either MII or RMII, and IEEE 1588 functionality helps align records captured by separate machines or production cells. The 3 V to 3.6 V supply range matches common 3.3 V logic systems, while the -40 °C to 85 °C rating addresses industrial ambient conditions. The 7 mm × 7 mm 48-WQFN package also conserves board area compared with larger legacy network interfaces. Layout should account for the exposed pad, close bypass connections, controlled clock routing, and the external magnetics interface specified by the manufacturer.

🤖

Synchronized Robotics

The DP83630SQX/NOPB is suitable for synchronized robotics and motion-control networks where distributed controllers need deterministic communication and coordinated timing. IEEE 1588 precision-time support helps maintain consistent network timing between robot controllers, vision nodes, and actuator controllers. The PHY supports MII and RMII host interfaces, allowing selection according to processor resources and board-space constraints. Its 3 V to 3.6 V operating range and -40 °C to 85 °C temperature specification fit industrial robotic equipment. Engineers must ensure that the system-level timing budget accounts for PHY latency, network topology, switch support, message processing, and actuator timing margins rather than relying on synchronization alone.

🌐

Networked Communication Equipment

The DP83630SQX/NOPB can serve communication equipment requiring a compact Ethernet physical layer and precise timing. Its 48-WQFN package measures 7 mm × 7 mm, making it useful where board area is constrained, while support for MII and RMII allows integration with different host-controller architectures. IEEE 1588 functionality adds value in systems where remote nodes exchange data and coordinate events against a shared time reference. The 3.3 V operating class and industrial -40 °C to 85 °C range support embedded networking equipment. Designers should review cable reach, internal PHY timing, media-magnetics recommendations, reference-clock stability, and thermal performance before finalizing the communications subsystem.

🧩

Embedded Control Systems

The DP83630SQX/NOPB is useful in embedded control systems that add synchronized Ethernet connectivity to an MCU, MPU, or FPGA. RMII can reduce host-side signal count when supported by the selected controller, while MII offers a direct parallel interface for designs with sufficient pin and routing resources. IEEE 1588 support helps coordinate distributed control tasks and timestamped events. The device operates from 3 V to 3.6 V and covers -40 °C to 85 °C, matching many embedded industrial platforms. The design team should confirm the host signal mapping, clock source, strap behavior, interrupt requirements, and exposed-pad connection in the manufacturer documentation before PCB release.

What are the key specifications of DP83630SQX/NOPB that engineers should know?
The DP83630SQX/NOPB is a 3.3 V IEEE 1588 Ethernet PHY transceiver with MII and RMII host interfaces in a 48-WQFN package. According to the Texas Instruments DP83630 product page, it is specified from -40 °C to 85 °C and uses a compact 7 mm × 7 mm RHS package. The device combines a 1/1 Ethernet transceiver with precision-time-protocol support. Its package, voltage range, industrial temperature grade, and tape-and-reel ordering form are the main selection factors for industrial network-interface designs.
Where can I download the DP83630SQX/NOPB datasheet PDF?
The official DP83630SQX/NOPB technical information is available through the Texas Instruments DP83630 product page at https://www.ti.com/product/DP83630. The product page provides the device description, ordering information, and manufacturer support resources. Use the document links associated with the DP83630 family to obtain the current manufacturer datasheet, including the complete pin description, timing tables, electrical characteristics, application circuit, and recommended external components.
Where can I find the DP83630SQX/NOPB pinout?
Use the pin-description table and package drawing in the Texas Instruments DP83630 manufacturer datasheet to locate the DP83630SQX/NOPB pinout. The component is a 48-pin WQFN in the RHS package, so the schematic symbol and PCB footprint must contain all 48 device terminals and the exposed-pad treatment specified by the manufacturer. Do not infer connections from another package or suffix; verify enable, clock, MII or RMII, power, ground, and media-side assignments against the current datasheet.
What is DP83630SQX/NOPB used for?
The DP83630SQX/NOPB is used as an Ethernet physical-layer interface for industrial systems requiring IEEE 1588 precision-time-protocol support. It provides MII and RMII connectivity toward a host controller and operates from 3 V to 3.6 V. According to the Texas Instruments product page, the device is intended for precision clock synchronization in real-time industrial connectivity. Suitable systems include synchronized automation, factory data acquisition, networked measurement, and communications equipment.
What is the operating voltage of DP83630SQX/NOPB?
The DP83630SQX/NOPB operates from 3 V to 3.6 V, supporting nominal 3.3 V Ethernet-interface designs. This voltage range is identified in the manufacturer listing for the DP83630SQX/NOPB. The host controller, clock source, and associated circuitry must use compatible logic levels, and the power rails should meet the decoupling and sequencing requirements stated in the Texas Instruments DP83630 datasheet.
What interface does DP83630SQX/NOPB support?
The DP83630SQX/NOPB supports both MII and RMII host interfaces. MII uses a wider parallel data and control interface, while RMII provides a more compact connection for compatible Ethernet controllers. According to the Texas Instruments DP83630 product information, both interfaces are available on this PHY family. The final controller connection, clocking method, and strap configuration should be selected from the manufacturer’s ordering and application information.
Is DP83630SQX/NOPB suitable for industrial automation?
Yes, the DP83630SQX/NOPB is suitable for industrial automation applications requiring Ethernet and IEEE 1588 timing functions. Its specified operating range is -40 °C to 85 °C, and the manufacturer identifies it for precision clock synchronization in real-time industrial connectivity. The -40 °C to 85 °C rating makes it appropriate for many factory-floor environments, while the final enclosure temperature, isolation, surge, and EMC requirements must also be verified for the installed system.
DP83630SQX/NOPB vs DP83630SQ/NOPB: which one should be selected?
Both parts are identified as 48-WQFN, 7 mm × 7 mm Ethernet PHYs supporting MII and RMII, so their ordering differences should be checked against the manufacturer part table before substitution. The DP83630SQX/NOPB orderable entry shows the RHS package, 48 pins, -40 °C to 85 °C, and tape-and-reel format. Compare the exact suffix, shipment form, and lifecycle rows on the Texas Instruments ordering page because the available web information does not establish all electrical differences between the two order codes.
When should I choose DP83630SQX/NOPB over another Ethernet PHY?
Choose the DP83630SQX/NOPB when the design needs a 3.3 V Ethernet PHY with integrated IEEE 1588 precision-time support, MII and RMII host-interface options, and an industrial -40 °C to 85 °C temperature range. These characteristics align with synchronized industrial automation, acquisition, and measurement systems. A general-purpose PHY is preferable only when precision synchronization is unnecessary or when the host interface, package, media support, and timing architecture differ.
Is DP83630SQX/NOPB the same as DP83TC814RRHARQ1?
No direct substitution should be assumed. The comparison data identifies both devices as active Ethernet transceivers supporting MII and RMII, but DP83TC814RRHARQ1 is identified as an automotive AEC-Q100 device in a different RRH package family. The DP83630SQX/NOPB uses a 48-WQFN RHS package and an industrial temperature range. Because package dimensions, exposed-pad requirements, automotive qualification, and device-specific functions differ, they are not drop-in replacements.
What can replace DP83630SQX/NOPB?
A valid replacement must match the DP83630SQX/NOPB package footprint, pin assignments, MII or RMII interface, 3 V to 3.6 V supply, IEEE 1588 behavior, and industrial-temperature requirements. The available cross-reference search did not identify a distinct pin-compatible substitute, so a generic Ethernet PHY should not be treated as an automatic replacement. Confirm any candidate with the Texas Instruments cross-reference process and review the manufacturer datasheets before approving it for an existing PCB.
What is the best drop-in replacement for DP83630SQX/NOPB?
The DP83630SQ/NOPB is the closest same-family orderable part identified in the manufacturer and distributor records, using the same 48-WQFN 7 mm × 7 mm configuration. Nevertheless, engineers should compare its exact ordering attributes and electrical table against the DP83630SQX/NOPB before substitution. No independent cross-brand part was confirmed as pin-to-pin compatible, so a claimed universal drop-in replacement would require a formal manufacturer cross-reference and board-level review.
How do I design the DP83630SQX/NOPB power and thermal layout?
Follow the Texas Instruments DP83630 datasheet for the exact exposed-pad, decoupling, and layout requirements. The part is a 48-WQFN device with an exposed thermal pad and a 3 V to 3.6 V operating range. Place required bypass capacitors adjacent to their assigned supply pins, provide a low-impedance ground-plane connection beneath the exposed pad, and keep sensitive clock and data routes away from switching-node and high-current return paths. Confirm junction-temperature limits with the actual board construction and loss data.
Where can I buy DP83630SQX/NOPB online and what is its price?
Use the Request a Quote form on this page to request current DP83630SQX/NOPB pricing, stock status, lead time, and shipment information. The part is identified as active and distributed in a tape-and-reel industrial configuration, but commercial terms can change by order quantity, date, and packaging requirement. Submit the target quantity and required shipment destination with the quote request so procurement can return the applicable commercial response.
What is the lead time for DP83630SQX/NOPB?
Request the current lead time through the Request a Quote form on this page. The DP83630SQX/NOPB is listed as an active 48-WQFN tape-and-reel configuration, but availability and manufacturing lead time depend on the requested quantity and current channel conditions. Provide the forecast quantity, production schedule, and destination so the commercial response can reflect the appropriate supply commitment.
Is DP83630SQX/NOPB in stock?
Submit a Request a Quote form for the current DP83630SQX/NOPB stock position and available shipment quantity. The manufacturer orderable listing identifies the device as active, but that product status does not by itself establish local inventory for a particular quantity. A dated availability answer should come from procurement after the required reel quantity, forecast, and delivery destination are known.

Data referensi engineering untuk DP83630SQX/NOPB — pembandingan, panduan desain, dan informasi konformitas.

Panduan Pemilihan

Choose the DP83630SQX/NOPB when the design requires an Ethernet PHY with IEEE 1588 precision-time support, a 3 V to 3.6 V supply, MII or RMII host connectivity, and an industrial -40 °C to 85 °C operating range. It is particularly suitable for synchronized automation, acquisition, robotics, and communication equipment. The DP83630SQ/NOPB is the closest same-family orderable candidate identified, but its exact order-code attributes should be confirmed before substitution. Do not select DP83TC814RRHARQ1 as a direct replacement: although it also supports Ethernet, MII, and RMII, it is identified as an automotive AEC-Q100 device with a different package family. For any proposed alternative, verify the footprint, pin map, clock inputs, strap configuration, synchronization behavior, temperature grade, media interface, and exposed-pad requirements. A general-purpose Ethernet PHY without IEEE 1588 capability should only be considered when system timing can be implemented elsewhere and all host-side functions remain unchanged.

Pembandingan dengan Alternatif

Parameter Umum Produk Ini DP83630SQ/NOPB
Brand Texas Instruments Texas Instruments
Package 48-WQFN (RHS) 48-WQFN (RHS)
Product Type IEEE 1588 PTP Ethernet PHY transceiver DP83630 Ethernet PHY transceiver
Host Interface MII and RMII MII and RMII
IEEE 1588 Support Yes Yes

Diferensiator Kunci

  • Integrated IEEE 1588 precision-time support (vsDP83630SQ/NOPB)
  • Compact industrial package (vsDP83TC814RRHARQ1)
  • Flexible host-side connectivity (vsDP83630SQ/NOPB)

Catatan Desain

Use the manufacturer’s WQFN land pattern and exposed-pad guidance without substituting a generic 48-pin footprint. Place the required bypass capacitors close to their assigned power pins, maintain a continuous ground reference beneath the package, and minimize loop area in the supply-return path. Route reference-clock and Ethernet media-side connections according to the recommended topology, while separating them from noisy power-conversion paths. Verify differential pair geometry and via symmetry against the selected magnetics and PCB-fabrication capability.

Validate the RMII or MII timing budget with the actual host controller, reference clock, PCB routing, and operating temperature. RMII timing is sensitive to clock skew and trace mismatch, so keep clock and data geometry controlled and observe the manufacturer’s input thresholds and setup/hold requirements. For IEEE 1588 applications, measure synchronization behavior over the intended topology rather than assuming that PHY support alone guarantees system-level timing accuracy. Include network delay, switch behavior, host timestamping, and calibration in end-system tests.

Estimated thermal behavior must be calculated using the actual input voltage, output dissipation, junction temperature, and board thermal resistance; the manufacturer datasheet does not provide a universal dissipation figure for every operating condition. Connect the 48-WQFN exposed pad to the recommended PCB copper and thermal-via structure, then verify junction temperature at the highest ambient temperature and maximum operating activity. Avoid relying on the small package outline alone as evidence of adequate cooling.

Do not approve a replacement solely from the Ethernet category or connector count. A valid substitution must reconcile the 48-WQFN footprint, exposed pad, 3.3 V supply, MII or RMII mapping, IEEE 1588 behavior, clock architecture, and industrial-temperature requirements. Also avoid assuming that the SQ and SQX order codes are interchangeable without reviewing the manufacturer ordering table. Review strap settings and termination details for the exact orderable part during schematic review.

Informasi Konformitas

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Bebas Logam Lengket
Unknown
Bebas Halogena
Unknown
Mineral Konflik
Unknown

The manufacturer identifies DP83630SQX/NOPB as an industrial-temperature Ethernet PHY in a 48-WQFN package; no explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals declaration was present in the cited records. AEC-Q100 is not applicable to this industrial orderable configuration.

Pencarian Terkait

dp83630sqx nopb DP83630SQX/NOPB datasheet DP83630SQX/NOPB pinout DP83630SQX/NOPB datasheet pdf DP83630SQX/NOPB equivalent DP83630SQX/NOPB replacement DP83630SQX/NOPB footprint DP83630SQX/NOPB application circuit Texas Instruments DP83630SQX/NOPB DP83630SQX/NOPB price DP83630SQX/NOPB stock DP83630SQX/NOPB vs DP83TC814RRHARQ1

Komponen dan Istilah Terkait

Texas Instruments DP83630SQX/NOPB DP83630SQ/NOPB DP83TC814RRHARQ1 IEEE 1588 Precision Time Protocol Ethernet PHY transceiver Network interface IC Interface IC Semiconductor MII RMII 48-WQFN WQFN package family Surface-mount package 3.3 V Ethernet interface Industrial temperature grade Factory automation Precision time synchronization Factory data acquisition Robotics Networked measurement Industrial Ethernet Exposed thermal pad
Kutipan Cepat RFQ
Isi detail lengkap — tim penjualan kami akan membalas dalam 24 jam
Nomor Part Manufaktur Paket QTY Harga Target Lengkap
✓
Kutipan telah disubmit!

Kami akan membalas email Anda dalam 24 jam

1
RFQ Dikirim
2
Kutipan Diterima
3
Order Ditempatkan
4
Pembayaran
5
Dikirim
6
Dikirim
Lihat Detil RFQ