ICL7109EQH+D - 12-Bit 30 SPS ADC | Analog Devices
MPN: ICL7109EQH+D ✓ AktifICL7109EQH+D Ringkasan
An ADC is an analog-to-digital converter, a semiconductor that transforms a continuously varying voltage into a numeric value for measurement, control, or display. The ICL7109 belongs to the dual-slope integrating ADC family within the broader ADC, data-converter, and signal-processing semiconductor hierarchy. Its integration-oriented architecture is designed for one converter per analog channel when multiplexers would add leakage, crosstalk, settling time, or complexity.
Principal characteristics include 12-bit resolution, a 30 SPS conversion rate, one analog input, one converter, dual-slope conversion, and three-state binary outputs. The parallel output arrangement supports direct connection to microprocessor or UART-compatible interface logic. The zero-integrator-phase design supports fast overload recovery while reducing crosstalk and hysteresis effects that can otherwise complicate repeated bipolar measurements.
The converter uses a dual-slope measurement technique in which the input is integrated over a defined interval and compared against a reference. This approach is well suited to relatively slow precision measurements because it can provide good noise rejection when the integration interval rejects unwanted periodic signals. The manufacturer identifies the device as production, with the ICL7109 family positioned for low-cost, one-converter-per-channel data-acquisition systems.
Typical uses include industrial panel meters, digital laboratory instruments, temperature-measurement systems, process-monitoring equipment, and data-acquisition modules requiring parallel digital output. Its low-power design and low input-bias-current characteristics are valuable when each sensor channel must remain electrically isolated from the converter input stage.
For a new design, verify the complete external reference, input, clock, reset, and output networks against the Analog Devices ICL7109 datasheet. Maintain compatible logic levels for three-state outputs and account for the conversion interval before sampling or updating the host controller. A 44-pin PLCC footprint is required, so replacing a device in a different package requires board redesign rather than simple substitution.
This page consolidates the confirmed resolution, conversion speed, package, operating options, source links, and application guidance into a design-focused reference. It also identifies qualified same-family alternatives and explains the constraints that must be checked before any replacement is approved.
Alternatif penggantian untuk ICL7109EQH+D — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.
Variasi di dalam seri ini
Model-series yang sama yang kompatibel dengan penggantian ICL7109EQH+D (sama faktor bentuk dan footprint) — berbeda di dalam Input Type, Package, Conversion Rate, Output Type, Power-On Reset.
ICL7109CQH+D
✅ Drop-InKontak untuk harga
Lihat Datasheet →ICL7109CQH+TD
✅ Drop-In📋 Alternatif referensi (tidak dalam katalog)
ICL7109IQH+D
✅ Drop-In📋 Alternatif referensi (tidak dalam katalog)
ICL7109EQH-TD
✅ Drop-In📋 Alternatif referensi (tidak dalam katalog)
ICL7109EQH+D Rating Maksimal & Karakteristik Listrik
| Resolusi | 12 bit |
| Conversion Rate | 30 samples/s |
| Converter Architecture | Dual-slope |
| Number of Inputs | 1 input |
| Number of Converters | 1 converter |
| Tipe Output | Three-state binary parallel output |
| Input Type | Bipolar input |
| Supply Type | Bipolar power supply |
| Power-On Reset | Included |
| Rentang Suhu Kerja | 0 °C to +70 °C |
| Paket | 44-pin PLCC, 16.59 mm × 16.59 mm |
| Terminal Count | 44 terminals |
| Tipe Mounting | Surface mount |
| Package Code | QCCJ |
ICL7109EQH+D qccj Diamant Konfigurasi Panduan
Konfigurasi pin untuk ICL7109EQH+D (qccj pakai pakai). Komponen analog ini memiliki pin masukan, keluaran, dan pengirim daya. Lihat datasheet produsen untuk konfigurasi pin offset null, kompensasi, dan pengaktifan. Ideal untuk peralatan sinyal dan kabel penggandaran.
Tidak ada data diatribut pin yang tersedia untuk ICL7109EQH+D.
Lihat ke: datasheet produk untuk konfigurasi pin penuh.
Aplikasi Umum
ICL7109EQH+D cocok untuk 6 aplikasis: Industrial Panel Meters, Digital Temperature Measurement, Laboratory Measurement Instruments, Process Monitoring Equipment, Data Acquisition Modules, Portable Measurement Instruments.
Industrial Panel Meters
ICL7109EQH+D fits industrial panel meters that display slowly changing analog measurements such as pressure, temperature, or process voltage. Its 12-bit resolution provides 4096 digital code levels, while the 30 SPS conversion rate is appropriate for panel updates that do not require high-speed sampling. The one-converter-per-channel arrangement can reduce the need for analog multiplexing, helping preserve low input-bias-current performance and simplify channel isolation. The 44-pin PLCC package provides a conventional surface-mount industrial footprint, but designers should verify temperature grade, reference accuracy, input conditioning, and host-interface timing against the Analog Devices ICL7109 datasheet before releasing production hardware.
Direkomendasikan
Digital Temperature Measurement
ICL7109EQH+D is suitable for digital thermometers and temperature controllers where a sensor produces a slowly changing analog voltage. The dual-slope ADC performs measurements up to 30 times per second, which is more than adequate for thermal readings that change gradually, while 12-bit resolution supports fine display increments. Its low input-bias current is useful when the sensor source has high impedance, and the one-input architecture avoids the leakage and settling effects of an analog multiplexer. The system designer must select the sensor excitation and reference network carefully, confirm the full-scale input range, and use the manufacturer’s differential-input and reference circuits to achieve accurate results over the intended temperature range.
Direkomendasikan
Laboratory Measurement Instruments
ICL7109EQH+D can provide the conversion function in a laboratory meter that reads relatively slow analog voltages but requires repeatable digital output for a processor, display, or communications interface. The 12-bit result and three-state parallel outputs support direct digital acquisition, while the 30 SPS rate allows continuous readings without the complexity of a high-speed converter clock. Its low-power architecture is beneficial in portable instruments, and the low input-bias current reduces loading of high-impedance sensor networks. For laboratory-grade accuracy, the analog front end, reference source, layout, calibration method, and input protection must be evaluated independently of the ADC’s nominal resolution.
Direkomendasikan
Process Monitoring Equipment
ICL7109EQH+D fits process-monitoring modules that repeatedly measure plant sensors and transmit the converted values to a controller. At 30 SPS, the converter can handle fast enough updates for many temperature, pressure, and level signals without introducing a high-throughput ADC’s power and complexity. Using one dual-slope converter per channel can improve isolation and simplify signal routing compared with a multiplexed analog front end. The zero-integrator-phase behavior also supports rapid recovery after overload conditions. Designers should still add suitable input protection, isolate external wiring from sensitive reference nodes, and confirm that the converter’s temperature grade and isolation strategy satisfy the installation environment.
Direkomendasikan
Data Acquisition Modules
ICL7109EQH+D is appropriate for low-channel data-acquisition modules where each analog channel requires independent conversion and the host processor needs a stable parallel result. Its 12-bit resolution, 30 SPS throughput, and three-state outputs provide a straightforward acquisition path without requiring a high-speed serial ADC interface. The one-converter-per-channel topology is especially relevant when avoiding multiplexer leakage and crosstalk is more important than minimizing total converter count. A practical module should include controlled reference distribution, separate analog and digital grounding strategies, input conditioning, and a handshake sequence that allows the controller to read stable three-state outputs without bus contention.
Direkomendasikan
Portable Measurement Instruments
ICL7109EQH+D supports portable measurement instruments because its dual-slope architecture combines useful resolution with low power consumption and a modest 30 SPS conversion rate. It is suited to handheld meters that periodically measure a high-impedance sensor rather than continuously streaming high-rate waveforms. The low input-bias current helps preserve sensor accuracy, and the three-state binary outputs allow connection to a low-power controller through a shared data path. Because the device requires a 44-pin PLCC footprint, the mechanical design must reserve that land pattern. Battery-operated products should also account for reference-current consumption, digital-interface idle current, input-signal settling, and the timing of repeated conversions.
Direkomendasikan
Ringkasan Produk Direkomendasikan
Data referensi engineering untuk ICL7109EQH+D — pembandingan, panduan desain, dan informasi konformitas.
Panduan Pemilihan
Pembandingan dengan Alternatif
| Parameter Umum | Produk Ini | ICL7109CQH+D | ICL7109CQH+TD | ICL7109IQH+D | ICL7109EQH-TD |
|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 44-pin PLCC (PQCC44) | 44-pin PLCC (PQCC44) | 44-pin PLCC (PQCC44) | 44-pin PLCC (PQCC44) | 44-pin PLCC (PQCC44) |
| Resolution | 12 bit | 12 bit | 12 bit | 12 bit | 12 bit |
| Conversion Rate | 30 samples/s | 30 samples/s | 30 samples/s | 30 samples/s | 30 samples/s |
| Converter Architecture | Dual-slope | Dual-slope | Dual-slope | Dual-slope | Dual-slope |
| Input and Channel Count | 1 bipolar input | 1 bipolar input | 1 bipolar input | 1 bipolar input | 1 bipolar input |
| Output Interface | Three-state binary parallel output | Three-state binary parallel output | Three-state binary parallel output | Three-state binary parallel output | Three-state binary parallel output |
| Temperature Grade | E-grade ordering designation | Commercial grade, 0 °C to +70 °C | Commercial grade, 0 °C to +70 °C | I-grade designation | E-grade designation |
| Power-On Reset | Included | Included | Included | Included | Included |
Diferensiator Kunci
- Extended-temperature ordering option (vsICL7109CQH+D)
- Same converter performance and footprint (vsICL7109EQH-TD)
- One converter per channel without multiplexing (vsICL7109CQH+TD)
Catatan Desain
Do not approve a substitute using package appearance alone. Verify the complete ordering code, temperature grade, pin functions, reference arrangement, and electrical limits in the Analog Devices ICL7109 datasheet, Revision 0. The commercial C-grade options are identified for 0 °C to +70 °C operation, while the E-grade suffix indicates a different thermal qualification. A mechanically identical 44-pin PLCC can still be unsuitable if its temperature range or production qualification does not match the original equipment.
Reserve the exact 44-pin PLCC land pattern and follow the manufacturer’s recommended layout for the analog input, reference, clock, supply, and digital-output sections. Place the input and reference components near their associated pins and keep digital output routing away from sensitive analog nodes. Because the converter uses three-state outputs, the host controller must ensure that no two devices drive the same bus simultaneously. Confirm all package dimensions from the official package drawing before releasing the PCB.
Design the bipolar supply rails and reference network from the Analog Devices ICL7109 electrical-characteristics table, including absolute maximum limits and startup behavior. Power-on reset is included, but it does not replace careful sequencing or decoupling. Use the manufacturer’s recommended supply and reference bypass components, and verify that the chosen regulator provides adequate headroom during startup. Ensure the host logic and the converter output levels are compatible before connecting the three-state parallel bus.
Allow a complete 30 samples-per-second conversion sequence before treating the parallel result as valid, and follow the converter’s specified handshake or busy timing in firmware. Keep the analog input and reference nets compact and shield them from clock and digital-output transitions. The zero-integrator-phase design improves overload recovery, but correct input protection and source impedance are still required to prevent saturation and preserve measurement accuracy after transients.
Informasi Konformitas
The ICL7109 family is listed as production by Analog Devices, but specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations for the exact ICL7109EQH+D ordering code were not present in the cited component pages.