Renesas Electronics

ICS513MT - 140MHz PLL Clock Generator | Renesas Electronics

MPN: ICS513MT ✓ Aktif
8-pin SOIC Package 140 MHz Speed
MOQ: 1 |

ICS513MT Ringkasan

The Renesas Electronics ICS513MT is a LOCO PLL clock generator and fanout distribution integrated circuit capable of operating up to 140 MHz. It accepts a clock or crystal reference, provides CMOS clock outputs, supports PLL bypass, and is packaged in an 8-pin SOIC package measuring approximately 3.90 mm wide. The device is designed for systems requiring a stable, distributed reference clock without implementing a discrete phase-locked-loop arrangement.

A PLL clock generator is a timing integrated circuit that locks an internal oscillator to an external reference and then produces one or more predictable clock outputs. The ICS513MT belongs to the LOCO family of clock generators, combining a phase-locked loop with fanout distribution in a small integrated package. Its clock-and-crystal input flexibility allows it to serve either an externally supplied reference or a 14.31818 MHz crystal, depending on the system architecture.

The principal operating features include a maximum frequency of 140 MHz, one clock-generation circuit, a 1:2 input-to-output ratio, CMOS output technology, and PLL bypass capability. The bypass function provides a practical alternative path when the design requires direct reference-clock behavior. The SOIC-8 package also supports conventional surface-mount assembly and gives the clock generator access to power, ground, input, and output functions within a compact footprint.

Technically, the part uses a phase-locked loop to establish an output clock related to its reference source. Because its primary inputs include either a crystal or external clock, the circuit can accommodate a frequency-standard reference used by communications, computing, control, and embedded systems. The 140 MHz upper operating frequency provides substantial timing headroom for digital logic, while the CMOS outputs are suited to systems using conventional CMOS clock-input thresholds. Exact operating limits, tolerance, and stability details must be confirmed in the manufacturer datasheet before release to production.

Typical applications include digital controller clocking, communications-interface timing, embedded processing modules, data-conversion systems, and general fanout distribution. It is particularly relevant when a board must derive a consistent high-frequency clock from a shared 14.31818 MHz reference while maintaining a compact surface-mount layout. In multi-load designs, output loading and trace length become important because excessive capacitance or impedance mismatch can degrade clock-edge quality.

The primary design consideration is to validate the reference frequency, PLL configuration, output loading, and decoupling against the worst operating conditions. Keep clock traces short, provide a clean return path, use appropriate series termination when edge rates are fast, and account for capacitive loading on every CMOS output. A solid ground plane and local input/output bypass capacitors help reduce supply-induced jitter and clock-edge distortion.

This product page combines the ICS513MT operating characteristics with package information, sourcing guidance, application analysis, and verified drop-in alternatives. It helps engineers identify whether the LOCO PLL architecture, 140 MHz capability, 1:2 ratio, and SOIC-8 footprint fit a new clock-distribution design before conducting board-level timing validation.

Alternatif penggantian untuk ICS513MT — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.

Variasi di dalam seri ini

Model-series yang sama yang kompatibel dengan penggantian ICS513MT (sama faktor bentuk dan footprint) — berbeda di dalam Device Type, Input Type, Number of Circuits, Package.

Renesas Electronics
Device Type: LOCO PLL clock generator and fanout distribution IC
Input Type: Crystal or clock
Number of Circuits: 1
Bandingkan dengan ICS513MT →

ICS513M

✅ Drop-In
Renesas Electronics
📦 SOIC-8
LOCO PLL clock generator and fanout distribution IC · 140 MHz · 1 · Yes, with bypass · Crystal or clock · CMOS · 1:2 · 14.31818 MHz

Kontak untuk harga

Lihat Datasheet →

ICS513MT Spesifikasi

Device Type PLL clock generator and fanout distribution IC
Maximum Frequency 140 MHz
PLL Yes, with bypass
Input Type Clock or crystal
Reference Crystal Frequency 14.31818 MHz
Tipe Output CMOS
Number of Circuits 1 circuit
Input-to-Output Ratio 1:2
Paket 8-pin SOIC
Package Width 3.90 mm
Tipe Mounting Surface mount

ICS513MT 3.90 mm Diamant Konfigurasi Panduan

Konfigurasi pin untuk ICS513MT (3.90 mm pakai pakai). Penomoran pin, fungsi, dan diagram koneksi ditetapkan dalam datasheet produsen. Lihatnya untuk footprint dan pedoman perpindahan paruh.

Diamant diagram pakai pakai 3.90 mm untuk ICS513MT

Tidak ada data diatribut pin yang tersedia untuk ICS513MT.

Lihat ke: datasheet produk untuk konfigurasi pin penuh.

Aplikasi Umum

ICS513MT cocok untuk 6 aplikasis: Digital Controller Clock Distribution, Communications Interface Timing, Embedded Processing Module Clocking, Data Acquisition and Conversion Timing, Industrial Control and Instrumentation, General Clock Fanout Network.

🖥️

Digital Controller Clock Distribution

The ICS513MT fits digital controller designs that need a stable reference-derived clock distributed to processors, logic, and memory-control circuits. Its clock-or-crystal input supports a 14.31818 MHz reference, while PLL operation and bypass provide two implementation choices for clock delivery. The maximum frequency of 140 MHz and 1:2 input-to-output ratio suit fixed-ratio architectures where a compact SOIC-8 implementation is preferable to a configurable clock tree. Place the device near the reference source, provide local bypassing, and route each CMOS output to a short, impedance-controlled clock trace. Engineers should verify timing margin and output loading across temperature and process conditions before production release.

🌐

Communications Interface Timing

The ICS513MT is appropriate for communications interface timing when a common reference must be converted into a predictable CMOS clock. Supporting both crystal and external-clock inputs allows the same architecture to serve locally referenced modules and board-level synchronized interfaces. Its PLL bypass function adds operational flexibility, while the 140 MHz maximum frequency provides ample range for many digital transports and control logic. Use a low-impedance reference path, maintain short output traces, and account for load-dependent edge degradation. Before schematic release, confirm the required reference frequency, supply voltage, output-current demand, and temperature range against the manufacturer datasheet.

⚙️

Embedded Processing Module Clocking

The ICS513MT can supply a fixed-ratio clock for embedded processors, real-time controllers, and programmable logic assemblies that require centralized timing. A single 8-pin SOIC-8 clock generator reduces the component count compared with a discrete oscillator and separate distribution stage. The LOCO PLL architecture accepts a 14.31818 MHz crystal or external clock, and the CMOS output can feed compatible digital clock inputs. Keep the oscillator loop or source connection short, avoid routing the clock beneath noisy power stages, and validate settling time after startup. The fixed 1:2 ratio should match the receiving logic; designs needing programmable divider ratios require a more flexible timing IC.

📡

Data Acquisition and Conversion Timing

The ICS513MT can provide the sampling or control clock for data-acquisition and data-conversion systems whose clock requirements can be satisfied by a fixed 1:2 relationship. The 140 MHz capability accommodates moderately fast digital processing chains, while CMOS outputs align with conventional digital clock-input requirements. For sensitive converters, keep the clock distribution route compact and isolate it from high-current switching paths to reduce coupled noise. The reference source should be specified with suitable accuracy and jitter for the acquisition bandwidth, and the output load should remain within the device's operating limits. Bench evaluation of edge quality and timing jitter is recommended at system level.

🏭

Industrial Control and Instrumentation

The ICS513MT is useful in industrial control and instrumentation designs that distribute a common clock to measurement, control, and communication logic. Its integrated PLL, bypass capability, and 1:2 ratio can reduce clock-tree complexity in compact control boards. The SOIC-8 package is compatible with conventional surface-mount manufacturing, but industrial temperature requirements and electromagnetic-emissions behavior must be checked for the final operating environment. Use a continuous ground plane, local decoupling, and controlled clock trace lengths to preserve edge quality. Where functional-safety or extended-temperature criteria apply, verify qualification and operating limits before incorporating the device into the production design.

🔧

General Clock Fanout Network

The ICS513MT serves as a compact fanout point for clock distribution in mixed digital systems. One internally generated CMOS clock can be routed to multiple receiving circuits, reducing duplicated oscillators and supporting synchronization across functional blocks. The fixed 1:2 ratio, PLL bypass option, and 140 MHz upper frequency make it practical for systems that do not require programmable outputs. Trace each branch directly to its destination, avoid excessive capacitive loading, and provide a nearby return path to suppress crosstalk. If receivers require different frequencies or phase relationships, separate clock domains or a programmable clock controller may be more appropriate than extending a single fanout network.

What is the ICS513MT?
The ICS513MT is a Renesas Electronics LOCO PLL clock generator and fanout distribution IC with a maximum operating frequency of 140 MHz. It accepts a clock or crystal reference, produces CMOS outputs, supports PLL bypass, and uses an 8-pin SOIC package. According to the manufacturer datasheet, it can generate a high-quality clock from a 14.31818 MHz crystal or external clock input, making it useful for embedded, communications, and digital control systems.
What are the key specifications of ICS513MT that engineers should know?
The key ICS513MT specifications are a 140 MHz maximum frequency, clock-or-crystal input, CMOS output, PLL bypass, one clock-generation circuit, and a 1:2 input-to-output ratio. The device is offered in an 8-pin SOIC package approximately 3.90 mm wide. These characteristics make it a compact choice when a design needs reference-locked clock generation and fanout rather than a general-purpose programmable clock architecture.
Where can I download the ICS513MT datasheet PDF?
The ICS513MT datasheet PDF is accessible through the manufacturer-document listing for the LOCO PLL clock generator. The document identifies the device as a clock generator and fanout distributor with clock or crystal input, CMOS output, PLL bypass, a maximum frequency of 140 MHz, and a 1:2 ratio. Use the pin-description table and electrical-characteristics sections of that document for production design and PCB verification.
Where can I find the ICS513MT pinout?
The ICS513MT pin assignment is documented in the pin-configuration section of the manufacturer datasheet. The device uses an 8-pin SOIC package, but individual pin names and functions are not published in the product listings used for this page. Before routing a PCB, assign every connection from the datasheet pin-description table rather than inferring functions from similar clock-generator packages.
What clock sources can ICS513MT accept?
The ICS513MT accepts either a clock or a crystal reference, and the manufacturer datasheet specifically describes use with a 14.31818 MHz crystal or clock input. Its PLL and bypass architecture supports reference-synchronized clock generation. The selected reference must match the device's configured operating requirements, while crystal loading, drive level, and startup behavior should be confirmed from the electrical characteristics before layout release.
What is the maximum frequency of ICS513MT?
The maximum frequency of the ICS513MT is 140 MHz. According to the manufacturer datasheet and product specifications, this limit applies to the clock-generation function and must be considered alongside the selected reference, PLL configuration, supply conditions, and output loading. For a design operating near 140 MHz, validate timing, jitter, and signal integrity at the prototype stage rather than relying only on the headline frequency.
Can ICS513MT replace a discrete crystal oscillator and PLL arrangement?
The ICS513MT can consolidate a crystal reference, PLL clock generation, and fanout distribution into one 8-pin SOIC device. That integration can simplify a board compared with a discrete oscillator and separate PLL arrangement. The trade-off is that the fixed 1:2 input-to-output ratio and the absence of programmable general-purpose divider outputs may make it less flexible than a configurable clock controller.
What is the difference between PLL mode and bypass mode on ICS513MT?
PLL mode locks the generated output to the external clock or crystal reference, while bypass mode provides an alternative clock path associated with the reference input. The ICS513MT explicitly supports PLL bypass according to the manufacturer datasheet. The appropriate mode depends on the clock architecture and validation requirements, so check the device's mode-selection logic and output behavior against the intended system timing.
ICS513MT vs ICS513M - which is better for a new clock-distribution design?
ICS513MT and ICS513M are closely related LOCO PLL clock-generator devices, but the final choice should be based on the exact ordering code, package, temperature rating, and lifecycle status. The ICS513MT is listed with a maximum frequency of 140 MHz, CMOS output, clock-or-crystal input, PLL bypass, and an 8-pin SOIC package. Confirm all four items for ICS513M in its current manufacturer documentation before treating it as a drop-in replacement.
When should I choose ICS513MT instead of a programmable clock generator?
Choose the ICS513MT when the design only needs a fixed 1:2 reference clock, PLL bypass, CMOS fanout, operation up to 140 MHz, and an SOIC-8 implementation. A programmable clock generator is preferable when the design requires selectable dividers, multiple independently programmable outputs, jitter attributes, or clock-tree features not provided by this LOCO device. The simpler fixed-ratio architecture can reduce design and validation effort.
Is ICS513MT suitable for communications and embedded-control systems?
The ICS513MT is suitable for communications and embedded-control clock-distribution requirements that can be met by a fixed-ratio LOCO PLL clock generator. Its 140 MHz maximum frequency, CMOS outputs, and support for a 14.31818 MHz crystal or external clock suit systems requiring a reference-derived clock. Confirm supply limits, temperature range, output loading, and jitter against the manufacturer's electrical characteristics before production use.
What is the best drop-in replacement for ICS513MT?
A drop-in replacement must use the same 8-pin SOIC footprint, preserve pin functions, and provide compatible electrical and timing performance. The ICS513M is the closest identified family alternative because it appears in a direct ICS513M versus ICS513MT comparison, but its temperature grade, lifecycle status, and ordering details should be confirmed before substitution. Use the Request a Quote form on this page to discuss a qualified replacement for the exact design requirements.
Can ICS513M replace ICS513MT in an existing PCB?
The ICS513M may be a candidate for ICS513MT because both are members of the same LOCO PLL clock-generator family and the ICS513M is directly compared with the ICS513MT. A true drop-in substitution still requires identical SOIC-8 pin mapping and compatible electrical, timing, temperature, and lifecycle characteristics. Confirm those points in the manufacturer documentation for both exact ordering codes before changing the BOM.
Where to buy ICS513MT online?
The ICS513MT can be requested through the Request a Quote form on this page. The form lets the buyer specify quantity, target reel or tray format, and delivery requirements without relying on static pricing. The part is listed in SOIC-8 packaging, and the ordering code shown by distributors is ICS513MT-ND, but current stock, authorized-channel status, and allocation should be confirmed during quotation.
What is the price of ICS513MT?
The current price of ICS513MT depends on order quantity, packaging, and market conditions, so a fixed figure should not be copied from a stale product page. Use the Request a Quote form on this page for a current quotation and available quantity breaks. The form provides a single sourcing path for pricing, lead time, and order confirmation for the exact 8-pin SOIC device.
What is the lead time for ICS513MT?
The current lead time for ICS513MT should be confirmed when the purchase order is prepared because it can change with supplier inventory and production planning. Submit the required quantity and packaging details through the Request a Quote form on this page. That request establishes the quotation date, available allocation, and expected delivery information for the exact ICS513MT ordering code.
Is ICS513MT in stock?
ICS513MT availability should be confirmed through the Request a Quote form on this page rather than inferred from an individual marketplace listing. Enter the required quantity, SOIC-8 packaging preference, and target delivery date. XAIPART will return the current stock position and lead-time information associated with the quotation, avoiding reliance on an outdated availability count.
How should ICS513MT be placed on a PCB for stable clocking?
Place the ICS513MT close to the clock source and the circuits it drives, keep clock traces short, and provide a continuous ground plane beneath the device. Add local supply bypassing at the power pins and use short return paths for every CMOS output. High-speed clock edges can increase radiated emissions and susceptibility to crosstalk, so validate output loading, trace impedance, and return-path continuity on the final board.

Data referensi engineering untuk ICS513MT — pembandingan, panduan desain, dan informasi konformitas.

Panduan Pemilihan

Choose the ICS513MT when the board needs a compact, fixed-ratio clock generator with PLL operation, bypass capability, CMOS outputs, and a maximum frequency of 140 MHz. It is well suited to designs using a 14.31818 MHz crystal or external reference and packaged in 8-pin SOIC-8. Choose ICS513M when its exact electrical ratings, temperature grade, pin mapping, and lifecycle status match the target design, since it is the closest identified alternative in the same LOCO family. For designs requiring programmable divider ratios, multiple configurable outputs, or detailed low-jitter specifications, select a programmable clock controller instead. Before releasing either choice, verify the reference frequency, supply voltage, output loading, startup sequence, timing margin, and PCB layout against the manufacturer datasheet.

Pembandingan dengan Alternatif

Parameter Umum Produk Ini ICS513M
Device Type PLL clock generator and fanout distribution IC PLL clock generator and fanout distribution IC
Brand Renesas Electronics Renesas Electronics
Package 8-pin SOIC 8-pin SOIC
Input Type Clock or crystal Clock or crystal
Output Type CMOS CMOS
PLL Bypass Supported Supported
Input-to-Output Ratio 1:2 1:2
Number of Circuits 1 circuit 1 circuit

Diferensiator Kunci

  • Integrated fixed-ratio clock generation and fanout (vsICS513M)
  • Reference-source flexibility (vsICS513M)
  • PLL bypass operation (vsICS513M)

Catatan Desain

Place the ICS513MT near the crystal or reference-clock source and minimize the length of the reference path. Keep clock outputs short, provide a continuous ground plane beneath the device, and route each CMOS output to its intended receiver without unnecessary branches. When edge rates are high, evaluate source termination and load capacitance rather than assuming that the nominal 140 MHz rating alone guarantees clean signal behavior.

Add local supply decoupling at the ICS513MT and maintain a low-impedance return to the ground plane. Follow the manufacturer datasheet for capacitor value, voltage rating, and placement requirements. A separate quiet-clock ground strategy may help in analog or mixed-signal systems, but clock and supply routing should remain consistent with the device's recommended layout to avoid adding jitter through unintended loop areas.

Do not assume that a similar LOCO ordering code is automatically interchangeable without checking the pinout, temperature grade, supply range, and lifecycle status. The 1:2 input-to-output ratio is fixed for the ICS513MT, so designs needing selectable ratios or multiple programmable outputs should use a configurable clock generator. Verify PLL versus bypass behavior and startup timing in the intended system rather than relying only on nominal frequency information.

Treat every CMOS clock output as a transmission line when its rise time is fast relative to the trace length. Maintain controlled return paths, avoid crossing noisy switching regions, and keep capacitive loading within the device's allowable output loading. If multiple receivers share an output, use a carefully designed fanout topology or a dedicated distribution buffer when rise-time degradation or edge reflection could compromise timing.

Informasi Konformitas

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Bebas Logam Lengket
Unknown
Bebas Halogena
Unknown
Mineral Konflik
Unknown

Compliance status was not identified in the product information used for this page. Confirm RoHS, REACH, lead-free, halogen-free, conflict-minerals, and automotive qualification directly with Renesas Electronics for the exact ordering code.

Data disahkan pada: 2026-11-05 — data disahkan dan disusun oleh tim engineering komponen XAIPART

Pencarian Terkait

ICS513MT datasheet ICS513MT datasheet pdf ICS513MT pinout ICS513MT specifications ICS513MT equivalent ICS513MT replacement ICS513MT vs ICS513M ICS513MT 140MHz PLL clock generator Renesas ICS513MT ICS513MT SOIC-8 clock IC ICS513MT price ICS513MT stock ICS513MT crystal input application

Komponen dan Istilah Terkait

Renesas Electronics ICS513MT ICS513M LOCO PLL clock generator clock generator fanout distribution IC phase-locked loop PLL CMOS clock input crystal input 14.31818 MHz crystal 140 MHz 1:2 input-to-output ratio SOIC-8 SOIC family surface-mount package SMD clock jitter clock edge quality CMOS clock output embedded control communications timing
Kutipan Cepat RFQ
Isi detail lengkap — tim penjualan kami akan membalas dalam 24 jam
Nomor Part Manufaktur Paket QTY Harga Target Lengkap
✓
Kutipan telah disubmit!

Kami akan membalas email Anda dalam 24 jam

1
RFQ Dikirim
2
Kutipan Diterima
3
Order Ditempatkan
4
Pembayaran
5
Dikirim
6
Dikirim