INA114BU/1K Ringkasan

Texas Instruments INA114BU/1K is a precision three-op-amp instrumentation amplifier with 1 MHz gain-bandwidth product, 50 µV maximum offset voltage, 11 nV/√Hz input noise, and approximately 3 mA power consumption in a 16-pin SOIC package. It amplifies differential sensor signals while rejecting common-mode interference, and a single external resistor sets gains from 1 to 10,000.

An instrumentation amplifier is a specialized analog amplifier optimized for measuring low-level signals embedded in large common-mode voltages. Its typical hierarchy is instrumentation amplifier, differential amplifier, analog amplifier, integrated circuit, and semiconductor. This signal-conditioning function is commonly placed between a bridge, strain gauge, thermocouple, or current-shunt sensor and an ADC, where common-mode rejection protects the sensor signal before conversion.

Key features include laser-trimmed low offset, 2.25 V to 18 V supply operation, internal input protection that can withstand voltages up to ±40 V, and a single-resistor gain-setting network. The 1 MHz bandwidth supports relatively fast measurements, while the 11 nV/√Hz noise specification is useful when resolving small differential signals. The 16-pin SOIC package also provides flexible input and output arrangements through its instrumentation-amplifier pinout.

The INA114 uses a three-op-amp signal topology to provide high input impedance and accurate differential amplification. A precision internal resistor network establishes the gain relationship, so designers select the external gain resistor according to the formula in the manufacturer datasheet. The device supports unipolar and bipolar signal measurement, although output swing and common-mode range must remain within the supply-dependent operating limits.

Typical uses include bridge-based pressure and force measurement, low-current power monitoring, portable medical instrumentation, industrial sensor acquisition, and precision test equipment. In each case, the benefit is accurate differential extraction with common-mode rejection rather than the maximum amplifier bandwidth. The 1 MHz specification should therefore be treated as a usable signal-path limit, not as a guarantee that every gain setting provides 1 MHz bandwidth.

A critical design consideration is gain bandwidth. Higher closed-loop gain reduces usable bandwidth and increases output-noise contribution, so filter and sampling decisions should follow the voltage-noise and gain error curves in the datasheet. Place the gain resistor close to the device, maintain symmetric input routing, and use a quiet reference implementation when the output must support bipolar signals.

This product page combines the manufacturer specifications with practical selection guidance, drop-in-replacement screening, application-oriented design notes, and parameter comparisons. It is intended to help engineers verify package compatibility, bandwidth, noise, protection capability, and supply constraints before committing a precision analog front end to production.

Alternatif penggantian untuk INA114BU/1K — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.

Variasi di dalam seri ini

Model-series yang sama yang kompatibel dengan penggantian INA114BU/1K (sama faktor bentuk dan footprint) — berbeda di dalam Input Offset Voltage Drift, Package, Operating Temperature Range, Architecture, Bandwidth.

Texas Instruments
Input Offset Voltage Drift: 5 uV/°C maximum
Package: 16-pin SOIC (DW)
Architecture: Current feedback
Texas Instruments
Input Offset Voltage Drift: 0.25 uV/degree C maximum
Architecture: Three-op-amp instrumentation amplifier
Bandwidth: 1 MHz
Texas Instruments
Input Offset Voltage Drift: 0.5 μV/°C
Package: 8-pin SOIC (0.154 inch, 3.90 mm width)
Operating Temperature Range: -40 °C to +85 °C

INA115BU

✅ Drop-In
Texas Instruments
📦 16-pin SOIC
Precision instrumentation amplifier · Three-op-amp instrumentation amplifier · 1 MHz · 50 uV · 0.25 uV/degree C maximum · 11 nV/sqrt(Hz) · 2 nA · 115 dB

Kontak untuk harga

Lihat Datasheet →

INA114BU/1K Rating Maksimal & Karakteristik Listrik

Product Type Precision instrumentation amplifier
Amplifier Architecture 3-op-amp instrumentation amplifier
Number of Channels 1 channel
Gain-Bandwidth Product 1 MHz
Maximum Offset Voltage 50 µV
Input Voltage Noise 11 nV/√Hz
Power Consumption 3 mA
Gain Range 1 to 10,000
Supply Voltage Range 2.25 V to 18 V
Maximum Input Protection ±40 V
Input Offset Voltage Drift 0.06 µV/°C
Rentang Suhu Kerja -40°C to +85°C
Paket 16-pin SOIC
Tipe Mounting Surface mount

Konfigurasi Pin INA114BU/1K

SOIC-16 Package Pinout Diagram SOIC-16 16-pin, 3.9x9.9mm, P1.27mm, JEDEC MS-012. 1 16 2 15 3 14 4 13 5 12 6 11 7 10 8 9 SOIC-16
Pin produk 1 RG — External gain-setting resistor connection
Pin produk 2 -IN — Inverting input for input channel A
Pin produk 3 +IN — Noninverting input for input channel A
Pin produk 4 -VS — Negative supply connection for input channel A
Pin produk 5 REF — Reference input for input channel A
Pin produk 6 OUT — Output for input channel A
Pin produk 7 VS — Positive supply connection for input channel A
Pin produk 8 RG — External gain-setting resistor connection
Pin produk 9 RG — External gain-setting resistor connection
Pin produk 10 -IN — Inverting input for input channel B
Pin produk 11 +IN — Noninverting input for input channel B
Pin produk 12 -VS — Negative supply connection for input channel B
Pin produk 13 REF — Reference input for input channel B
Pin produk 14 OUT — Output for input channel B
Pin produk 15 VS — Positive supply connection for input channel B
Pin produk 16 RG — External gain-setting resistor connection

Aplikasi Umum

INA114BU/1K cocok untuk 6 aplikasis: Bridge-Based Pressure and Force Measurement, Strain Gauge Signal Conditioning, Portable Medical Signal Acquisition, Low-Current Power Rail Monitoring, Precision Test and Measurement, Industrial Sensor Signal Conditioning.

🏭

Bridge-Based Pressure and Force Measurement

The INA114BU/1K fits Wheatstone bridge front ends because its differential architecture extracts the small imbalance signal generated by resistance changes while rejecting much of the bridge excitation common-mode voltage. The 50 µV maximum offset and 0.06 µV/°C drift help preserve measurement accuracy as temperature changes, while the 11 nV/√Hz input noise supports resolution of low-level force and pressure signals. Place the device near the bridge and its gain resistor to minimize susceptible input traces. Confirm that the bridge excitation, common-mode voltage, and selected gain remain within the Texas Instruments INA114 datasheet operating limits. Accuracy at high gain also depends on stable resistor tolerances, excitation supply quality, and appropriate filtering after the amplifier rather than excessive bandwidth that would amplify unwanted noise.

🏭

Strain Gauge Signal Conditioning

The INA114BU/1K is appropriate for strain-gauge amplifiers because the useful strain output is differential and may be much smaller than the excitation voltage imposed on both inputs. The instrumentation amplifier's matched internal paths provide accurate subtraction of that common-mode level. Its 1 MHz gain-bandwidth product permits useful bandwidth at moderate gains, while the single-resistor gain setting simplifies adjustment for different strain sensitivities. The 16-pin SOIC footprint supports conventional surface-mounted analog layouts, and the specified -40°C to +85°C range covers many industrial environments. Keep excitation return current away from the input traces, secure stable reference and supply connections, and verify allowable input and output swings in the manufacturer datasheet before finalizing the front end.

💊

Portable Medical Signal Acquisition

INA114BU/1K can serve as the precision analog front end in portable medical equipment when the sensor output is differential and small relative to its common-mode voltage. The 11 nV/√Hz input-noise specification and 50 µV maximum offset support accurate recovery of weak physiological signals, while approximately 3 mA power consumption is appropriate for power-conscious instrumentation. Its input-protection capability can withstand voltages up to ±40 V, although that rating must not be treated as permission to exceed the application-specific limits. A biomedical designer should also evaluate patient protection, leakage, isolation, and certification requirements separately. The amplifier should be powered from a clean low-noise source, and its gain resistor and input routing should be positioned for repeatability and minimal thermal influence.

⚡

Low-Current Power Rail Monitoring

The INA114BU/1K is useful for high-side or low-side shunt measurements where the voltage drop across a sense resistor must be measured accurately in the presence of supply-related common-mode voltage. Differential input paths keep the shunt voltage distinct from the larger supply level, and gains up to 10,000 allow millivolt-level drops to be amplified for conversion. The 1 MHz bandwidth is more than adequate for many power-monitoring loops, but the selected gain determines the actual usable bandwidth and noise behavior. Keep the shunt connections short, use Kelvin routing where possible, and verify that the common-mode voltage stays within the INA114 operating range. The result can feed an ADC such as ADS8519IDB for telemetry, protection, or power-budget analysis.

🔧

Precision Test and Measurement

INA114BU/1K supports bench and production test systems that measure low-level differential signals with substantial common-mode content. The 1 MHz bandwidth permits useful response for moderate-gain measurements, while laser-trimmed low offset and low drift improve repeatability. A single external resistor gives a straightforward way to configure gain for bridge, thermocouple-style, or general-purpose differential probes. The amplifier can sit close to the fixture to minimize lead and interference pickup before the signal reaches an ADC. Care should be taken to select a gain that preserves adequate bandwidth and output range rather than maximizing gain unconditionally. Calibration can correct residual gain and offset error, but stable layout, low-temperature-drift resistors, clean grounding, and appropriate input filtering remain the primary controls on measurement quality.

🧩

Industrial Sensor Signal Conditioning

The INA114BU/1K is well suited to industrial sensor interfaces that require differential extraction before digitization. Its high input impedance limits loading on the sensor, and the internal common-mode rejection reduces errors from long cables, shared grounds, and electrically noisy environments. The 16-pin SOIC package integrates easily into compact analog boards, while 2.25 V to 18 V supply operation supports both low-voltage and conventional industrial rails. Choose the gain according to the sensor output and ADC input range, then validate common-mode headroom and output swing against the Texas Instruments INA114 datasheet. Use short, symmetric input traces, solid ground-plane return paths, and filtering at the ADC when additional rejection is needed. The amplifier's -40°C to +85°C specification is useful for many industrial installations, subject to the complete system's thermal environment.

What are the key specifications of INA114BU/1K that engineers should know?
The INA114BU/1K is a single-channel precision instrumentation amplifier with 1 MHz gain-bandwidth product, 50 µV maximum offset voltage, 11 nV/√Hz input noise, and approximately 3 mA power consumption. It supports supply voltages from 2.25 V to 18 V, operates from -40°C to +85°C, and uses one external resistor to establish gains from 1 to 10,000. According to the Texas Instruments INA114 datasheet, the device is packaged in a 16-pin SOIC for surface-mounted precision signal-conditioning designs.
What is the operating voltage range of INA114BU/1K?
The INA114BU/1K operates from 2.25 V to 18 V. The Texas Instruments INA114 datasheet identifies this range as the valid supply-voltage window for the precision instrumentation amplifier. Designers must also verify the permitted input common-mode range and output swing for the particular gain and supply configuration. A low supply voltage can provide adequate headroom for small signals, while higher supply voltages require attention to the absolute maximum ratings and protection network design.
How is the gain of INA114BU/1K set?
The INA114BU/1K gain is set with one external resistor connected to the gain-setting network, allowing gains from 1 to 10,000. The Texas Instruments INA114 datasheet provides the gain equation and recommended resistor values. Use the specified resistor network rather than estimating gain from the nominal internal resistor alone. Place the gain resistor close to the device to minimize parasitic resistance, and verify the selected gain against the voltage-noise, gain-error, and bandwidth curves.
What noise and offset performance does INA114BU/1K provide?
The INA114BU/1K specifies 50 µV maximum offset voltage, 0.06 µV/°C offset drift, and 11 nV/√Hz input voltage noise. These figures make the device suitable for precision differential measurements where input error and drift must remain small relative to the sensed signal. According to the Texas Instruments INA114 datasheet, total output error also depends on gain, so low-noise signal wiring and stable gain resistors remain important even when the input-referred noise specification is favorable.
Where can I download the INA114BU/1K datasheet PDF?
The official INA114BU/1K datasheet PDF is available from Texas Instruments at https://www.ti.com/lit/ds/symlink/ina114.pdf. The manufacturer product page at https://www.ti.com/product/INA114 provides ordering information, package options, and related technical resources. Use the manufacturer PDF for the authoritative pin description, gain equation, electrical characteristics, typical performance curves, and recommended application circuits.
Where can I find the INA114BU/1K pinout?
The INA114BU/1K pinout is documented in the Texas Instruments INA114 datasheet, with the 16-pin SOIC assignments covering both input channels, supply connections, reference input, output, and gain resistor terminals. Use the pin-description table when assigning PCB tracks. Because this package exposes mirrored signal and supply connections, verify every net against the selected package drawing rather than relying on a generic image of a SOIC footprint.
Is INA114BU/1K suitable for low-level bridge sensor measurements?
Yes, INA114BU/1K is well suited to low-level bridge measurements because its differential architecture rejects common-mode voltage while preserving a small sensor output. The 50 µV maximum offset, 0.06 µV/°C drift, and 11 nV/√Hz input noise support accurate force, pressure, and strain measurements. According to the Texas Instruments INA114 datasheet, practical accuracy still depends on excitation stability, gain resistor tolerance, input common-mode range, and keeping the gain resistor close to the amplifier.
What can replace INA114BU/1K without changing the PCB?
A PCB-compatible replacement must use the same 16-pin SOIC pinout and satisfy the input, output, supply, gain-setting, bandwidth, and common-mode requirements. INA115BU is the closest same-manufacturer candidate found in the replacement comparison material, but engineers must verify its pin assignments and electrical limits against the INA114 datasheet. A functional instrumentation amplifier with a different package or pinout is not a drop-in replacement and should not be substituted without PCB changes.
What is the best cross-brand equivalent for INA114BU/1K?
The best cross-brand equivalent is the device that matches the 16-pin SOIC pinout while preserving the 1-to-10,000 gain range, input protection, offset, noise, supply range, and common-mode limits. The cross-reference results identify related precision instrumentation amplifiers, but they do not provide enough MPN-level pin and parameter information to certify a cross-brand drop-in replacement. Treat functional equivalents as redesign candidates until their datasheets and footprint details have been checked line by line.
When should I choose INA114BU/1K instead of a general-purpose operational amplifier?
Choose INA114BU/1K when the source is a small differential signal riding on a substantial common-mode voltage. Its internal three-op-amp arrangement provides matched input paths, high common-mode rejection, and a resistor-programmed gain without requiring multiple discrete amplifiers. A general-purpose operational amplifier may be sufficient for single-ended signals, but it generally needs more external circuitry for differential measurement. The choice should also account for the INA114's 1 MHz bandwidth and 11 nV/√Hz noise specification.
Is INA114BU/1K suitable for medical and industrial sensor interfaces?
The INA114BU/1K can be used in medical and industrial sensor interfaces when its electrical limits match the application. Its 11 nV/√Hz input noise and 50 µV maximum offset are useful for low-level physiological or industrial signals, while ±40 V internal input protection adds robustness. The Texas Instruments INA114 datasheet specifies a -40°C to +85°C operating range. Medical or safety-critical designs must additionally verify applicable system-level qualification and regulatory requirements.
How does INA114BU/1K compare with INA115BU?
INA114BU/1K and INA115BU are closely related Texas Instruments precision instrumentation amplifiers offered in the same 16-pin SOIC family, but their offset, drift, bias-current, and noise details should be compared before substitution. Both provide resistor-programmed gain and are intended for precision differential measurements. Use the manufacturer datasheets to verify exact pin compatibility and the operating conditions relevant to the design; a shared package designation alone does not establish electrical equivalence.
Where can I request a quote for INA114BU/1K and confirm lead time?
Use the Request a Quote form on this page to request INA114BU/1K availability, lead time, and order quantities. The form is the appropriate commercial channel for a quote-first purchase and can capture the exact MPN, including the INA114BU/1K suffix. Confirm the package, tape-and-reel quantity, and any required traceability at the time of quotation rather than relying on a historical catalog reference.
What is the current availability of INA114BU/1K?
Use the Request a Quote form on this page to confirm current INA114BU/1K stock and expected lead time. Texas Instruments lists the INA114 product family on its official product page, while the exact orderable status and shipment timing can change with demand and packaging requirements. Include the full INA114BU/1K MPN and required quantity in the request so the response reflects the correct 16-pin SOIC configuration.
How should I design the PCB around INA114BU/1K?
Place the INA114BU/1K gain-setting resistor close to its gain terminals, keep the two input paths compact and symmetric, and route them away from switching nodes and high-current paths. Provide a low-impedance supply return and follow the Texas Instruments INA114 datasheet recommendations for bypass capacitance. When the reference pin is used, keep its impedance low and isolate it from noisy sources. Differential routing also helps minimize conversion of board-coupled interference into the measured signal.

Data referensi engineering untuk INA114BU/1K — pembandingan, panduan desain, dan informasi konformitas.

Panduan Pemilihan

Choose INA114BU/1K when the design needs a low-cost, general-purpose precision instrumentation amplifier with differential input handling, a single-resistor gain-setting network, and a 16-pin SOIC footprint. Its 50 µV maximum offset, 0.06 µV/°C drift, 11 nV/√Hz input noise, and 1 MHz gain-bandwidth product make it appropriate for bridges, strain gauges, shunts, and general industrial sensor interfaces. INA115BU is the closest screened same-manufacturer alternative when its offset, drift, bias-current, noise, and protection characteristics better match a precision design; confirm its electrical data and pin assignments before substitution. Functional equivalents from other manufacturers should be treated as redesign candidates unless they are proven to share the exact 16-pin pinout. Neither package similarity nor instrumentation-amplifier functionality is sufficient by itself. Also favor INA114BU/1K when the external gain-resistor approach, 2.25 V to 18 V supply range, and approximately 3 mA operating-power target align with the system architecture.

Pembandingan dengan Alternatif

Parameter Umum Produk Ini INA115BU
Brand Texas Instruments Texas Instruments
Package 16-pin SOIC 16-pin SOIC
Product Type Precision instrumentation amplifier Precision instrumentation amplifier
Architecture 3-op-amp instrumentation amplifier 3-op-amp instrumentation amplifier
Gain-Bandwidth Product 1 MHz 1 MHz
Gain Range 1 to 10,000 1 to 10,000

Diferensiator Kunci

  • Single-resistor gain programming across a wide range (vsINA115BU)
  • Precision offset and drift for low-level differential signals (vsINA115BU)
  • Documented input protection for robust sensor interfaces (vsINA115BU)
  • Low-noise operation with flexible gain selection (vsINA115BU)

Catatan Desain

Place the INA114 gain-setting resistor directly between the appropriate gain terminals and minimize the surrounding loop area. Route the two differential inputs as short, closely matched traces and keep them away from switching inductors, power MOSFETs, relay contacts, and high-speed digital clocks. A solid ground plane and a quiet return path reduce common-mode and differential conversion of board noise. Confirm the final pin assignments against the manufacturer pin-description table because the 16-pin SOIC exposes mirrored channel connections.

Do not select gain independently of bandwidth and output-noise requirements. Although the INA114 has a 1 MHz gain-bandwidth product, usable bandwidth decreases as closed-loop gain increases. Follow the Texas Instruments datasheet gain, noise, and frequency-response curves when choosing the external resistor. If an antialias filter is required, place it after accounting for the amplifier's own bandwidth and settling behavior. This prevents an unnecessarily high gain from magnifying broadband noise into the ADC input.

Operate the INA114BU/1K only within its 2.25 V to 18 V supply range and maintain the required common-mode and output-swing headroom. The approximately 3 mA power-consumption figure does not include every board-level loss, so use the complete supply-current and thermal data when designing a low-power system. Follow the manufacturer bypass-capacitor recommendations and connect the exposed analog ground structure directly to a low-impedance ground plane. Do not rely on the ±40 V input-protection rating as permission to exceed application-specific limits.

A common design error is treating every instrumentation amplifier with a 16-pin SOIC as a footprint-compatible substitute. Verify pin names, gain-resistor connections, input and output assignments, reference behavior, supply limits, input common-mode range, and protection characteristics before releasing a replacement to production. Another common error is grounding the reference pin arbitrarily; leave it unconnected only when the manufacturer's circuit permits the intended output-reference arrangement. Use the pin-description table and application schematic in the Texas Instruments INA114 datasheet for final connections.

Informasi Konformitas

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Bebas Logam Lengket
Unknown
Bebas Halogena
Unknown
Mineral Konflik
Unknown

The manufacturer product page and datasheet are the governing sources for ordering, environmental, and quality information. Compliance status was not explicitly stated in the accessible product information and therefore remains unknown rather than assumed.

Data disahkan pada: 2026-11-19 — data disahkan dan disusun oleh tim engineering komponen XAIPART

Pencarian Terkait

INA114BU/1K datasheet INA114BU/1K pinout INA114BU/1K datasheet pdf INA114BU/1K specifications INA114BU/1K price INA114BU/1K stock INA114BU/1K equivalent INA114BU/1K replacement INA114BU/1K vs INA115BU Texas Instruments INA114BU/1K INA114BU/1K 16-SOIC footprint INA114BU/1K bridge sensor amplifier INA114BU/1K application circuit INA114BU/1K gain calculation

Komponen dan Istilah Terkait

Texas Instruments INA114BU/1K INA114 INA115BU precision instrumentation amplifier instrumentation amplifier three-op-amp instrumentation amplifier differential amplifier analog amplifier integrated circuit semiconductor signal conditioning common-mode rejection input voltage noise offset voltage gain-bandwidth product 16-pin SOIC SOIC package family surface-mount package Wheatstone bridge strain gauge low-side current shunt ADS8519IDB ADS1262IPW ADS1131IDR
Kutipan Cepat RFQ
Isi detail lengkap — tim penjualan kami akan membalas dalam 24 jam
Nomor Part Manufaktur Paket QTY Harga Target Lengkap
✓
Kutipan telah disubmit!

Kami akan membalas email Anda dalam 24 jam

1
RFQ Dikirim
2
Kutipan Diterima
3
Order Ditempatkan
4
Pembayaran
5
Dikirim
6
Dikirim
Lihat Detil RFQ