INA114BU/1K - 1MHz Precision Instrumentation Amplifier | TI
MPN: INA114BU/1K ✓ AktifINA114BU/1K Ringkasan
An instrumentation amplifier is a specialized analog amplifier optimized for measuring low-level signals embedded in large common-mode voltages. Its typical hierarchy is instrumentation amplifier, differential amplifier, analog amplifier, integrated circuit, and semiconductor. This signal-conditioning function is commonly placed between a bridge, strain gauge, thermocouple, or current-shunt sensor and an ADC, where common-mode rejection protects the sensor signal before conversion.
Key features include laser-trimmed low offset, 2.25 V to 18 V supply operation, internal input protection that can withstand voltages up to ±40 V, and a single-resistor gain-setting network. The 1 MHz bandwidth supports relatively fast measurements, while the 11 nV/√Hz noise specification is useful when resolving small differential signals. The 16-pin SOIC package also provides flexible input and output arrangements through its instrumentation-amplifier pinout.
The INA114 uses a three-op-amp signal topology to provide high input impedance and accurate differential amplification. A precision internal resistor network establishes the gain relationship, so designers select the external gain resistor according to the formula in the manufacturer datasheet. The device supports unipolar and bipolar signal measurement, although output swing and common-mode range must remain within the supply-dependent operating limits.
Typical uses include bridge-based pressure and force measurement, low-current power monitoring, portable medical instrumentation, industrial sensor acquisition, and precision test equipment. In each case, the benefit is accurate differential extraction with common-mode rejection rather than the maximum amplifier bandwidth. The 1 MHz specification should therefore be treated as a usable signal-path limit, not as a guarantee that every gain setting provides 1 MHz bandwidth.
A critical design consideration is gain bandwidth. Higher closed-loop gain reduces usable bandwidth and increases output-noise contribution, so filter and sampling decisions should follow the voltage-noise and gain error curves in the datasheet. Place the gain resistor close to the device, maintain symmetric input routing, and use a quiet reference implementation when the output must support bipolar signals.
This product page combines the manufacturer specifications with practical selection guidance, drop-in-replacement screening, application-oriented design notes, and parameter comparisons. It is intended to help engineers verify package compatibility, bandwidth, noise, protection capability, and supply constraints before committing a precision analog front end to production.
Alternatif penggantian untuk INA114BU/1K — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.
Variasi di dalam seri ini
Model-series yang sama yang kompatibel dengan penggantian INA114BU/1K (sama faktor bentuk dan footprint) — berbeda di dalam Input Offset Voltage Drift, Package, Operating Temperature Range, Architecture, Bandwidth.
INA115BU
✅ Drop-InKontak untuk harga
Lihat Datasheet →INA114BU/1K Rating Maksimal & Karakteristik Listrik
| Product Type | Precision instrumentation amplifier |
| Amplifier Architecture | 3-op-amp instrumentation amplifier |
| Number of Channels | 1 channel |
| Gain-Bandwidth Product | 1 MHz |
| Maximum Offset Voltage | 50 µV |
| Input Voltage Noise | 11 nV/√Hz |
| Power Consumption | 3 mA |
| Gain Range | 1 to 10,000 |
| Supply Voltage Range | 2.25 V to 18 V |
| Maximum Input Protection | ±40 V |
| Input Offset Voltage Drift | 0.06 µV/°C |
| Rentang Suhu Kerja | -40°C to +85°C |
| Paket | 16-pin SOIC |
| Tipe Mounting | Surface mount |
Konfigurasi Pin INA114BU/1K
| Pin produk 1 | RG — External gain-setting resistor connection |
| Pin produk 2 | -IN — Inverting input for input channel A |
| Pin produk 3 | +IN — Noninverting input for input channel A |
| Pin produk 4 | -VS — Negative supply connection for input channel A |
| Pin produk 5 | REF — Reference input for input channel A |
| Pin produk 6 | OUT — Output for input channel A |
| Pin produk 7 | VS — Positive supply connection for input channel A |
| Pin produk 8 | RG — External gain-setting resistor connection |
| Pin produk 9 | RG — External gain-setting resistor connection |
| Pin produk 10 | -IN — Inverting input for input channel B |
| Pin produk 11 | +IN — Noninverting input for input channel B |
| Pin produk 12 | -VS — Negative supply connection for input channel B |
| Pin produk 13 | REF — Reference input for input channel B |
| Pin produk 14 | OUT — Output for input channel B |
| Pin produk 15 | VS — Positive supply connection for input channel B |
| Pin produk 16 | RG — External gain-setting resistor connection |
Aplikasi Umum
INA114BU/1K cocok untuk 6 aplikasis: Bridge-Based Pressure and Force Measurement, Strain Gauge Signal Conditioning, Portable Medical Signal Acquisition, Low-Current Power Rail Monitoring, Precision Test and Measurement, Industrial Sensor Signal Conditioning.
Bridge-Based Pressure and Force Measurement
The INA114BU/1K fits Wheatstone bridge front ends because its differential architecture extracts the small imbalance signal generated by resistance changes while rejecting much of the bridge excitation common-mode voltage. The 50 µV maximum offset and 0.06 µV/°C drift help preserve measurement accuracy as temperature changes, while the 11 nV/√Hz input noise supports resolution of low-level force and pressure signals. Place the device near the bridge and its gain resistor to minimize susceptible input traces. Confirm that the bridge excitation, common-mode voltage, and selected gain remain within the Texas Instruments INA114 datasheet operating limits. Accuracy at high gain also depends on stable resistor tolerances, excitation supply quality, and appropriate filtering after the amplifier rather than excessive bandwidth that would amplify unwanted noise.
Direkomendasikan
Strain Gauge Signal Conditioning
The INA114BU/1K is appropriate for strain-gauge amplifiers because the useful strain output is differential and may be much smaller than the excitation voltage imposed on both inputs. The instrumentation amplifier's matched internal paths provide accurate subtraction of that common-mode level. Its 1 MHz gain-bandwidth product permits useful bandwidth at moderate gains, while the single-resistor gain setting simplifies adjustment for different strain sensitivities. The 16-pin SOIC footprint supports conventional surface-mounted analog layouts, and the specified -40°C to +85°C range covers many industrial environments. Keep excitation return current away from the input traces, secure stable reference and supply connections, and verify allowable input and output swings in the manufacturer datasheet before finalizing the front end.
Direkomendasikan
Portable Medical Signal Acquisition
INA114BU/1K can serve as the precision analog front end in portable medical equipment when the sensor output is differential and small relative to its common-mode voltage. The 11 nV/√Hz input-noise specification and 50 µV maximum offset support accurate recovery of weak physiological signals, while approximately 3 mA power consumption is appropriate for power-conscious instrumentation. Its input-protection capability can withstand voltages up to ±40 V, although that rating must not be treated as permission to exceed the application-specific limits. A biomedical designer should also evaluate patient protection, leakage, isolation, and certification requirements separately. The amplifier should be powered from a clean low-noise source, and its gain resistor and input routing should be positioned for repeatability and minimal thermal influence.
Direkomendasikan
Low-Current Power Rail Monitoring
The INA114BU/1K is useful for high-side or low-side shunt measurements where the voltage drop across a sense resistor must be measured accurately in the presence of supply-related common-mode voltage. Differential input paths keep the shunt voltage distinct from the larger supply level, and gains up to 10,000 allow millivolt-level drops to be amplified for conversion. The 1 MHz bandwidth is more than adequate for many power-monitoring loops, but the selected gain determines the actual usable bandwidth and noise behavior. Keep the shunt connections short, use Kelvin routing where possible, and verify that the common-mode voltage stays within the INA114 operating range. The result can feed an ADC such as ADS8519IDB for telemetry, protection, or power-budget analysis.
Direkomendasikan
Precision Test and Measurement
INA114BU/1K supports bench and production test systems that measure low-level differential signals with substantial common-mode content. The 1 MHz bandwidth permits useful response for moderate-gain measurements, while laser-trimmed low offset and low drift improve repeatability. A single external resistor gives a straightforward way to configure gain for bridge, thermocouple-style, or general-purpose differential probes. The amplifier can sit close to the fixture to minimize lead and interference pickup before the signal reaches an ADC. Care should be taken to select a gain that preserves adequate bandwidth and output range rather than maximizing gain unconditionally. Calibration can correct residual gain and offset error, but stable layout, low-temperature-drift resistors, clean grounding, and appropriate input filtering remain the primary controls on measurement quality.
Direkomendasikan
Industrial Sensor Signal Conditioning
The INA114BU/1K is well suited to industrial sensor interfaces that require differential extraction before digitization. Its high input impedance limits loading on the sensor, and the internal common-mode rejection reduces errors from long cables, shared grounds, and electrically noisy environments. The 16-pin SOIC package integrates easily into compact analog boards, while 2.25 V to 18 V supply operation supports both low-voltage and conventional industrial rails. Choose the gain according to the sensor output and ADC input range, then validate common-mode headroom and output swing against the Texas Instruments INA114 datasheet. Use short, symmetric input traces, solid ground-plane return paths, and filtering at the ADC when additional rejection is needed. The amplifier's -40°C to +85°C specification is useful for many industrial installations, subject to the complete system's thermal environment.
Direkomendasikan
Ringkasan Produk Direkomendasikan
Data referensi engineering untuk INA114BU/1K — pembandingan, panduan desain, dan informasi konformitas.
Panduan Pemilihan
Pembandingan dengan Alternatif
| Parameter Umum | Produk Ini | INA115BU |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Package | 16-pin SOIC | 16-pin SOIC |
| Product Type | Precision instrumentation amplifier | Precision instrumentation amplifier |
| Architecture | 3-op-amp instrumentation amplifier | 3-op-amp instrumentation amplifier |
| Gain-Bandwidth Product | 1 MHz | 1 MHz |
| Gain Range | 1 to 10,000 | 1 to 10,000 |
Diferensiator Kunci
- Single-resistor gain programming across a wide range (vsINA115BU)
- Precision offset and drift for low-level differential signals (vsINA115BU)
- Documented input protection for robust sensor interfaces (vsINA115BU)
- Low-noise operation with flexible gain selection (vsINA115BU)
Catatan Desain
Place the INA114 gain-setting resistor directly between the appropriate gain terminals and minimize the surrounding loop area. Route the two differential inputs as short, closely matched traces and keep them away from switching inductors, power MOSFETs, relay contacts, and high-speed digital clocks. A solid ground plane and a quiet return path reduce common-mode and differential conversion of board noise. Confirm the final pin assignments against the manufacturer pin-description table because the 16-pin SOIC exposes mirrored channel connections.
Do not select gain independently of bandwidth and output-noise requirements. Although the INA114 has a 1 MHz gain-bandwidth product, usable bandwidth decreases as closed-loop gain increases. Follow the Texas Instruments datasheet gain, noise, and frequency-response curves when choosing the external resistor. If an antialias filter is required, place it after accounting for the amplifier's own bandwidth and settling behavior. This prevents an unnecessarily high gain from magnifying broadband noise into the ADC input.
Operate the INA114BU/1K only within its 2.25 V to 18 V supply range and maintain the required common-mode and output-swing headroom. The approximately 3 mA power-consumption figure does not include every board-level loss, so use the complete supply-current and thermal data when designing a low-power system. Follow the manufacturer bypass-capacitor recommendations and connect the exposed analog ground structure directly to a low-impedance ground plane. Do not rely on the ±40 V input-protection rating as permission to exceed application-specific limits.
A common design error is treating every instrumentation amplifier with a 16-pin SOIC as a footprint-compatible substitute. Verify pin names, gain-resistor connections, input and output assignments, reference behavior, supply limits, input common-mode range, and protection characteristics before releasing a replacement to production. Another common error is grounding the reference pin arbitrarily; leave it unconnected only when the manufacturer's circuit permits the intended output-reference arrangement. Use the pin-description table and application schematic in the Texas Instruments INA114 datasheet for final connections.
Informasi Konformitas
The manufacturer product page and datasheet are the governing sources for ordering, environmental, and quality information. Compliance status was not explicitly stated in the accessible product information and therefore remains unknown rather than assumed.