An instrumentation amplifier is a precision amplifier designed to amplify small differential signals while rejecting common-mode voltage and interference. The INA2128UA/1K uses a three-op-amp instrumentation-amplifier architecture, combining differential input, high input impedance, accurate gain control, and strong common-mode rejection. It belongs to the broader signal-chain hierarchy of instrumentation amplifier, analog amplifier, and semiconductor.
The device provides a maximum input offset voltage of 50 µV, input offset drift of 0.5 µV/°C maximum, and input bias current of 5 nA maximum. Its current-feedback input circuitry maintains 200 kHz bandwidth at a gain of 100. A single external gain resistor selects gains from 1 to 10,000, simplifying adjustment across precision measurement systems.
The INA2128UA/1K operates from dual supplies up to ±18 V and provides input protection to ±40 V. According to the Texas Instruments product information, the internal input-protection structure helps the amplifier survive excessive input voltage while preserving precision measurement performance. Both amplifier channels share the same 16-pin SOIC footprint.
Typical uses include bridge and strain-gauge amplification, precision sensor interfaces, biomedical instrumentation, current measurement, and low-level differential signal acquisition. The two-channel architecture is useful when a system must monitor two related sensor outputs or amplify a differential signal plus a reference or auxiliary channel.
For reliable operation, place the external gain resistor close to the gain-setting pin and maintain symmetric input routing. Input filtering, grounding, and supply bypassing must be designed around the required signal bandwidth, common-mode range, and source impedance rather than only the maximum rated gain.
This product page combines the Texas Instruments device description, distributor availability information, package and ordering details, and application-oriented engineering guidance to support component selection, footprint planning, and precision analog design.
Alternatif penggantian untuk INA2128UA/1K — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.
Variasi di dalam seri ini
Model-series yang sama yang kompatibel dengan penggantian INA2128UA/1K (sama faktor bentuk dan footprint) — berbeda di dalam Gain Range, Maximum Supply Voltage, Package.
INA2128U/1K
✅ Drop-InKontak untuk harga
Lihat Datasheet →INA2128UA/1K Rating Maksimal & Karakteristik Listrik
| Number of Amplifier Channels | 2 channels |
| Amplifier Architecture | Three-op-amp instrumentation amplifier |
| Paket | 16-pin SOIC |
| Maximum Supply Voltage | ±18 V |
| Gain Range | 1 to 10,000 V/V |
| Gain-Setting Method | One external resistor |
| Bandwidth at Gain 100 | 200 kHz |
| Gain-Bandwidth Product | 1.3 MHz |
| Maximum Input Offset Voltage | 50 µV |
| Maximum Input Offset Drift | 0.5 µV/°C |
| Maximum Input Bias Current | 5 nA |
| Minimum Common-Mode Rejection Ratio | 120 dB |
| Maximum Input Protection Voltage | ±40 V |
| Slew Rate | 4 V/µs |
| Power Category | Low-power instrumentation amplifier |
| Tipe Mounting | Surface mount |
INA2128UA/1K 16-pin soic Diamant Konfigurasi Panduan
Konfigurasi pin untuk INA2128UA/1K (16-pin soic pakai pakai). Komponen analog ini memiliki pin masukan, keluaran, dan pengirim daya. Lihat datasheet produsen untuk konfigurasi pin offset null, kompensasi, dan pengaktifan. Ideal untuk peralatan sinyal dan kabel penggandaran.
Tidak ada data diatribut pin yang tersedia untuk INA2128UA/1K.
Lihat ke: datasheet produk untuk konfigurasi pin penuh.
Aplikasi Umum
INA2128UA/1K cocok untuk 6 aplikasis: Bridge and Strain-Gauge Signal Conditioning, Biomedical Sensor Signal Acquisition, Current-Shunt Measurement, Precision Pressure and Resistance Sensing, Industrial Process-Control Front End, Two-Channel Auxiliary and Differential Measurement.
Bridge and Strain-Gauge Signal Conditioning
The INA2128UA/1K fits precision bridge measurement because its 50 µV maximum offset voltage and 0.5 µV/°C maximum drift limit errors from the amplifier itself. Its 120 dB minimum CMRR helps reject supply and ground-potential disturbances that can corrupt low-level bridge differentials. Place the gain resistor close to the device and calculate its value for the required mechanical range; bridge excitation stability, lead resistance, and resistor matching must also be included in the total error budget. The two channels can process related sensing channels, such as a measurement bridge and a temperature-compensation bridge, when system grounding remains suitable for common-mode rejection.
Direkomendasikan
Biomedical Sensor Signal Acquisition
The INA2128UA/1K is appropriate for low-level differential biomedical sensor signals because its 5 nA maximum input bias current limits disturbance of high-impedance sources and its 120 dB minimum CMRR rejects common-mode pickup. The 50 µV offset rating and 0.5 µV/°C drift specification support stable measurements from sources such as bio-potential electrodes or resistive bridges. Electrical safety, patient protection, electrode protection, leakage current, and applicable medical qualification are system-level requirements and must be evaluated separately. Keep sensor traces away from clocks and power-converter nodes, use guarded grounding where appropriate, and validate the complete analog chain against the required input range and bandwidth.
Direkomendasikan
Current-Shunt Measurement
The INA2128UA/1K can measure the small differential voltage produced by a current shunt while rejecting the high common-mode voltage present in the power path. Its low 5 nA maximum bias current is favorable for high-resistance sensing arrangements, and its 120 dB minimum CMRR improves rejection of switching ripple and load-transient disturbances. Select the external gain resistor to place the expected shunt voltage within the amplifier’s usable input range, then confirm the operating common-mode limits. Place Kelvin connections directly to the shunt pads, keep the sense pair together, and route it away from inductors and high di/dt conductors to preserve accuracy.
Direkomendasikan
Precision Pressure and Resistance Sensing
The INA2128UA/1K supports pressure, force, and resistive-sensor interfaces that produce small differential outputs over a substantial common-mode range. The device combines 50 µV maximum offset, 0.5 µV/°C maximum drift, and 120 dB minimum CMRR with gains programmable from 1 to 10,000, allowing one amplifier family to cover multiple sensitivity ranges. For pressure transmitters with ratiometric excitation, excitation drift can appear as measurement error and must be included in system calibration. Use shielded or guarded sensor wiring where noise is significant, maintain symmetrical input routing, and size input filters according to the required response rather than the amplifier’s 1.3 MHz gain-bandwidth product.
Direkomendasikan
Industrial Process-Control Front End
The INA2128UA/1K can condition low-level differential process signals before industrial digitization or control. Its two amplifier channels support compact multi-sensor systems, while 200 kHz bandwidth at gain 100 provides useful response for many sensor and control-loop signals. The 120 dB minimum CMRR helps reject process-side common-mode voltage and mixed analog/digital ground disturbances, provided the signal stays within the permitted common-mode range. Design the front end for galvanic isolation and surge protection as required by the installation, rather than assuming the amplifier’s ±40 V input-protection rating covers every fault. Use the 16-pin SOIC footprint and place bypassing, filtering, and gain components close to the device.
Direkomendasikan
Two-Channel Auxiliary and Differential Measurement
The INA2128UA/1K is useful when a system must measure a main differential signal and a second auxiliary channel in the same compact package. Two independent channels can handle a sensor output and a temperature or reference signal, provided each channel has adequate input and output headroom and uses the correct gain resistor. The dual architecture reduces the need for separate single-channel instrumentation amplifiers, while the 16-pin SOIC package supports conventional surface-mount assembly. Check whether the channels require independent bandwidth, settling-time, and common-mode considerations. Accurate channel matching also depends on resistor tolerance, reference quality, layout symmetry, and calibration; the IC specifications alone do not eliminate board-level mismatch.
Direkomendasikan
Ringkasan Produk Direkomendasikan
Data referensi engineering untuk INA2128UA/1K — pembandingan, panduan desain, dan informasi konformitas.
Panduan Pemilihan
Pembandingan dengan Alternatif
| Parameter Umum | Produk Ini | INA2128U/1K |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Package | 16-pin SOIC | 16-pin SOIC |
| Number of Channels | 2 channels | 2 channels |
| Product Type | Dual low-power instrumentation amplifier | Instrumentation amplifier |
Diferensiator Kunci
- Two precision channels in one 16-pin SOIC (vsINA2128U/1K)
- Single-resistor gain programming (vsINA2128U/1K)
- Low-offset precision for bridge and sensor measurements (vsINA2128U/1K)
- High common-mode rejection with input protection (vsINA2128U/1K)
Catatan Desain
Route the two inputs of each differential channel as a close, symmetric pair and connect the external gain resistor directly to the gain-setting pin. Keep the loop area small to minimize coupled magnetic noise and avoid sharing sensitive input traces with switching nodes. The 5 nA maximum input bias current and 120 dB minimum CMRR are useful specifications, but their benefits depend on clean grounding, controlled source impedances, and low leakage around the input nodes.
Use the 200 kHz bandwidth at gain 100 as a practical signal-chain reference rather than assuming the full 1.3 MHz gain-bandwidth product is usable at every gain. Place input filters close to the amplifier and calculate their interaction with source resistance, amplifier input impedance, and required settling time. For instrumentation-amplifier layouts, preserve symmetry between the differential paths because unmatched routing can degrade common-mode rejection and channel-to-channel balance.
The INA2128UA/1K accepts dual supplies up to ±18 V, but its ±40 V input-protection rating does not authorize normal operation at that voltage. Confirm the actual common-mode input range for the selected supply arrangement and design external protection where sensor wiring can exceed the normal range. Follow the manufacturer’s supply-bypass recommendations and place decoupling capacitors where they can suppress switching noise without adding excessive trace inductance.
Do not select a gain resistor without including its tolerance, temperature coefficient, parasitic inductance, and operating power in the error budget. A 1% resistor can make an otherwise accurate amplifier gain unsuitable for a precision measurement. Also verify that both channels remain within their input and output common-mode limits at minimum and maximum signal levels; a gain setting that works at nominal load can saturate during startup, fault recovery, or full-scale operation.
Informasi Konformitas
Compliance fields remain unknown because the manufacturer product and distributor information does not state the requested certification results. Do not infer automotive qualification, RoHS compliance, REACH compliance, or lead-free status from the device family name alone.