SI2404-C-FS Ringkasan

Skyworks Solutions SI2404-C-FS is a 2.4 kbps ISOmodem system-side interface IC supporting V.21, V.22, V.23, V.29, Bell 103, and Bell 212A data formats in a 16-pin SOIC package. It operates from a 3.3 V supply and uses SPI and UART interfaces, providing a compact interface between a host processor and a telephone-line modem chipset.

An ISOmodem is a dedicated integrated modem-circuit device used to encode and decode analog telephone-line signals into digital data. Within the product hierarchy, the SI2404-C-FS belongs to the modem IC family, which falls under network controller and processor interface ICs. Its 2.4 kbps signaling rate is intended for low-speed data communication, remote control, alarm reporting, telemetry, and point-to-point equipment links rather than modern broadband access.

The device supports V.21, V.22, V.23, V.29, Bell 103, and Bell 212A formats, allowing it to interoperate with compatible telephone-network equipment. Its 2.4 kbps rate and 4.92 MHz operating frequency are fixed operating characteristics rather than adjustable high-speed interfaces. SPI and UART connections give an embedded controller access to modem status and configuration functions without requiring a separate host interface circuit.

The SI2404-C-FS is offered in a 16-pin SOIC package measuring approximately 3.90 mm in body width. Tube packaging and a lead-free, RoHS-compliant construction support conventional surface-mount assembly and regulated production workflows. Because it is a line-side signaling and modem-interface device, its implementation depends on the surrounding ISOmodem chipset, isolation network, telephone-line interface, clocking, and host firmware.

Typical uses include industrial telemetry terminals, security equipment, remote monitoring controllers, telephone-line data bridges, and legacy equipment interfaces. SPI control suits embedded processors with dedicated serial peripherals, while UART can simplify connections to microcontrollers or modules that lack SPI. At 2.4 kbps, application data rates must be sized around the modem protocol overhead and telephone-line conditions.

Use the manufacturer datasheet pin-description table when assigning PCB tracks, and confirm clock, interface levels, and line-side circuit requirements before layout. Component values around the analog interface are sensitive to grounding, supply return paths, and layout symmetry, so follow the recommended application circuit and component-selection guidance rather than substituting values generically.

This page organizes the SI2404-C-FS protocol capabilities, package information, sourcing details, application guidance, and replacement considerations into one engineering-focused reference. It also separates confirmed product attributes from parameters that require direct confirmation in the manufacturer datasheet before a new design is released for production.

Alternatif penggantian untuk SI2404-C-FS — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.

Tidak ada alternatif pengganti yang tersedia untuk produk ini.

Permintaan Alternatif

SI2404-C-FS Spesifikasi

Product Type ISOmodem system-side modem IC
Laju Data 2.4 kbps
Operating Frequency 4.92 MHz
Supported Data Formats V.21, V.22, V.23, V.29, Bell 103, Bell 212A
Host Interface SPI and UART
Tegangan Pemuat Kerja 3.3 V
Package Type 16-pin SOIC
Package Body Width 3.90 mm
Packaging Tube
Tipe Mounting Surface mount
Lead-Free Status Lead free
Status RoHS RoHS compliant
Automotive Qualification No
AEC-Q100 Qualification No

SI2404-C-FS 3.90 mm Diamant Konfigurasi Panduan

Konfigurasi pin untuk SI2404-C-FS (3.90 mm pakai pakai). Penomoran pin, fungsi, dan diagram koneksi ditetapkan dalam datasheet produsen. Lihatnya untuk footprint dan pedoman perpindahan paruh.

Diamant diagram pakai pakai 3.90 mm untuk SI2404-C-FS

Tidak ada data diatribut pin yang tersedia untuk SI2404-C-FS.

Lihat ke: datasheet produk untuk konfigurasi pin penuh.

Aplikasi Umum

SI2404-C-FS cocok untuk 6 aplikasis: Industrial Telephone-Line Telemetry, Remote Monitoring and Alarm Reporting, Security and Surveillance Equipment, Legacy Equipment Data Bridge, Point-to-Point Telemetry Terminal, Microcontroller-Based Communications Controller.

🏭

Industrial Telephone-Line Telemetry

The SI2404-C-FS fits low-speed industrial telemetry equipment that must exchange measurements, alarms, or configuration data through a telephone-line modem chipset. Its 2.4 kbps operation supports compact periodic reports, while SPI provides a deterministic connection to a suitable embedded processor and UART offers an alternative for simpler controllers. A practical design uses the SI2404-C-FS with the required line-side network, clock circuitry, isolation components, and chipset, while limiting message size to account for protocol overhead and variable telephone-line quality.

🧩

Remote Monitoring and Alarm Reporting

The SI2404-C-FS is applicable to remote monitoring equipment that reports alarms through a telephone network instead of a continuously connected digital link. Its supported V.21, V.22, V.23, V.29, Bell 103, and Bell 212A formats provide several modem signaling choices, and the 3.3 V supply simplifies integration with modern embedded systems. The host processor can use SPI or UART to exchange commands and status. Firmware should include call establishment, timeout, retry, and line-failure handling because a 2.4 kbps modem link is affected by network conditions.

📥

Security and Surveillance Equipment

The SI2404-C-FS can support telephone-line data functions in security installations that need backup command or event reporting. A 2.4 kbps channel is sufficient for concise status messages, configuration commands, and identification records, but it is not intended for continuous video transport. The 16-pin SOIC package supports compact board layouts, and the 3.3 V operating supply can share infrastructure with a security controller. Designers should follow the manufacturer reference circuit for isolation, grounding, and line-side coupling because incorrect telephone-network isolation can create safety and signal-integrity problems.

🌐

Legacy Equipment Data Bridge

The SI2404-C-FS is useful when an embedded controller must communicate with legacy telephone-network equipment through a standard modem chipset. The device supports several established modem formats, including Bell 103 and Bell 212A, making it relevant to systems designed around V.21, V.22, V.23, or V.29 operation. SPI and UART host interfaces reduce the burden of driving modem commands directly. Firmware must implement the required timing and handshake behavior, and engineers should verify electrical levels and pin assignments against the manufacturer datasheet before retrofitting the circuit.

📡

Point-to-Point Telemetry Terminal

The SI2404-C-FS suits compact point-to-point telemetry terminals where each endpoint communicates over a telephone line at low data rate. Its 2.4 kbps signaling capability and 4.92 MHz operating frequency are suitable for short status packets, configuration exchange, and periodic sensor readings rather than file transfers. The interface can be managed through SPI or UART according to processor capability. Because link throughput is limited, application data should be compressed or summarized before transmission, and the design should include modem-status monitoring to distinguish a disconnected line from a powered terminal.

🔧

Microcontroller-Based Communications Controller

The SI2404-C-FS can serve as the communications engine in a microcontroller-based controller that needs modem behavior over a telephone line. A microcontroller using SPI receives deterministic access to modem status and control functions, while a UART-only controller can use the alternate serial path. The 3.3 V operating supply and 16-pin SOIC package facilitate compact assembly, although exact logic thresholds and timing must be confirmed before PCB design. The implementation should separate the digital host circuitry from the analog line-side network and follow the manufacturer’s recommended grounding and decoupling arrangement.

What is the Skyworks Solutions SI2404-C-FS?
The Skyworks Solutions SI2404-C-FS is a 2.4 kbps ISOmodem system-side interface IC packaged in a 16-pin SOIC. It supports V.21, V.22, V.23, V.29, Bell 103, and Bell 212A data formats, operates from a 3.3 V supply, and provides SPI and UART host interfaces. According to the manufacturer product information, the SI2404-C-FS is intended for telephone-line modem chipset implementations requiring a compact line-side modem interface.
What are the key specifications of SI2404-C-FS that engineers should know?
The SI2404-C-FS is a 2.4 kbps ISOmodem IC operating at 4.92 MHz with a 3.3 V supply. Its principal interfaces are SPI and UART, and its supported formats include V.21, V.22, V.23, V.29, Bell 103, and Bell 212A. The device uses a 16-pin SOIC package with an approximately 3.90 mm body width. These characteristics make it relevant to embedded telephone-line telemetry, remote monitoring, and legacy data-equipment designs.
Where can I download the SI2404-C-FS datasheet PDF?
The SI2404-C-FS datasheet is available through the product document linked on this page. The manufacturer datasheet is the controlling source for pin assignments, electrical limits, timing, interface behavior, and recommended application circuits. Before release, use that document to confirm the complete pinout, clock requirements, supply tolerances, and line-side component values. A secondary document host is shown because the manufacturer PDF URL was not included in the product records.
Where can I find the SI2404-C-FS pinout?
The SI2404-C-FS uses a 16-pin SOIC package, but a complete numbered pin assignment is not published in the product record displayed on this page. Use the pin-description table and land-pattern drawing in the manufacturer datasheet when assigning traces or creating a PCB footprint. Do not infer the pinout solely from the SPI, UART, clock, and supply functions, because their positions and signal directions must be confirmed for safe board-level integration.
What data rates and modem formats does SI2404-C-FS support?
The SI2404-C-FS supports a 2.4 kbps data rate and the V.21, V.22, V.23, V.29, Bell 103, and Bell 212A data formats. According to Skyworks product information, its operating frequency is 4.92 MHz. These are low-speed telephone-line modem characteristics, so designers should account for protocol framing overhead, line noise, and connection establishment time when estimating useful application throughput.
Is the SI2404-C-FS suitable for telephone-line telemetry?
Yes, the SI2404-C-FS is suitable for low-speed telephone-line telemetry when the system uses a compatible ISOmodem chipset and line-side network. Its 2.4 kbps rate, 3.3 V operation, and SPI or UART host connection support embedded reporting and remote-control equipment. The application must also provide the required clocking, isolation, telephone-line coupling, and firmware specified by the manufacturer reference design.
SI2404-C-FS vs SI2404-C-FT: which one matches an existing 16-pin SOIC design?
The SI2404-C-FS is the 16-pin SOIC member of the comparison, while the SI2404-C-FT is identified as a 24-pin TSSOP variant. Therefore, an existing 16-pin SOIC layout should be evaluated against the SI2404-C-FS; the SI2404-C-FT is not a footprint-compatible substitute. Both are described as modem-chip products in the SI2404 series, but package pin count and pinout differences make them distinct implementation choices.
What is the difference between SI2404-C-FS and SI2404-C-FT?
The principal documented difference is package and pin count: the SI2404-C-FS uses a 16-pin SOIC, whereas the SI2404-C-FT uses a 24-pin TSSOP. Both are identified as SI2404-series modem chips with 2.4 kbps operation, a 4.92 MHz operating frequency, 3.3 V supply, and SPI/UART interfaces. Because the packages differ, the SI2404-C-FT requires a different PCB footprint and cannot directly replace the SI2404-C-FS.
When should I choose SI2404-C-FS over another SI2404-series modem?
Choose the SI2404-C-FS when the design requires a 16-pin SOIC footprint, a 2.4 kbps modem interface, 3.3 V operation, and SPI or UART connectivity. The SI2404-C-FT may be considered for a different 24-pin TSSOP layout, but it is not a drop-in replacement. The final selection should also require confirmation of line-side topology, pin compatibility, protocol behavior, and lifecycle requirements for the production program.
Is SI2404-C-FS suitable for industrial remote monitoring?
The SI2404-C-FS can fit an industrial remote-monitoring design when the equipment uses a compatible telephone-line modem chipset. Its SPI interface is convenient for a processor with an embedded SPI controller, while UART can simplify integration with a microcontroller that lacks SPI. Because the link operates at only 2.4 kbps, the application should use compact messages and avoid designs that require continuous high-volume data transfer.
What can replace SI2404-C-FS on the same PCB?
No verified pin-to-pin replacement for the SI2404-C-FS has been established for this page. The SI2404-C-FSR and SI2404-C-GTR cross-reference records do not by themselves prove that either device has the same 16-pin SOIC footprint, electrical ratings, and pin functions. Treat a replacement as valid only after its manufacturer datasheet confirms package dimensions, numbered pin assignments, supply limits, clocking, and host-interface compatibility.
Is there a cross-brand equivalent for the SI2404-C-FS?
No cross-brand equivalent can be recommended confidently for the SI2404-C-FS without a manufacturer pin-for-pin comparison. A valid replacement would need the same 16-pin SOIC footprint, compatible SPI and UART connections, 3.3 V operation, equivalent clock requirements, and equivalent modem control behavior. Ask for an engineering review of the required modem functions and provide the existing schematic so the candidate can be checked against every connected signal.
Where can I buy SI2404-C-FS online and what is its price?
Use the Request a Quote form on this page to request SI2404-C-FS pricing, stock confirmation, and current lead time. The form allows the request to be matched to the exact 16-pin SOIC ordering code and avoids confusion with related SI2404 variants. Current commercial terms should be confirmed at request time because component availability and lifecycle conditions can change without notice.
What is the lead time and stock status for SI2404-C-FS?
Current stock and lead time for the SI2404-C-FS should be confirmed through the Request a Quote form on this page. Include the quantity, tube-packaging requirement, date-code preference, and target delivery date in the request. This approach is especially important because the SI2404 series contains several suffix and package combinations, and a valid replacement request must preserve the exact 16-pin SOIC device.
Does the SI2404-C-FS comply with RoHS and lead-free requirements?
The SI2404-C-FS is identified as RoHS compliant and lead free. It is not identified as AEC-Q100 qualified or automotive qualified, which is appropriate for conventional industrial, telecommunications, and embedded applications rather than automotive production. REACH status, halogen-free status, and conflict-minerals status are not established in the product record and should be confirmed with the manufacturer before a regulated procurement review.

Data referensi engineering untuk SI2404-C-FS — pembandingan, panduan desain, dan informasi konformitas.

Panduan Pemilihan

Choose the SI2404-C-FS when a new or retrofit design requires a 2.4 kbps ISOmodem interface in a 16-pin SOIC package. Its combination of 3.3 V operation, 4.92 MHz operating frequency, SPI and UART interfaces, and support for V.21, V.22, V.23, V.29, Bell 103, and Bell 212A makes it suitable for telephone-line telemetry, monitoring, security reporting, and legacy equipment bridges. The SI2404-C-FT is a reasonable family alternative only when the PCB can accept its 24-pin TSSOP footprint and its complete interface behavior satisfies the design. Do not select a replacement solely from the SI2404 prefix: verify package drawings, numbered pin assignments, clock requirements, voltage levels, line-side topology, and lifecycle status. For new production programs, confirm current supply, lead time, and the manufacturer’s latest datasheet revision before freezing the schematic and PCB layout.

Pembandingan dengan Alternatif

Parameter Umum Produk Ini
Package 16-pin SOIC
Brand Skyworks Solutions
Data Rate 2.4 kbps
Operating Frequency 4.92 MHz
Operating Supply Voltage 3.3 V
Host Interface SPI and UART
Supported Data Formats V.21, V.22, V.23, V.29, Bell 103, Bell 212A
Packaging Tube
RoHS Status RoHS compliant
Automotive Qualification No

Diferensiator Kunci

  • Compact 16-pin SOIC implementation (vsSI2404-C-FT)
  • Multiple established modem formats (vsSI2404-C-FT)
  • Dual host-interface options (vsSI2404-C-FT)

Catatan Desain

Assign the PCB footprint only after checking the SI2404-C-FS manufacturer package drawing, including body width, lead span, pitch, and seating-plane tolerances. The product information identifies a 16-pin SOIC package with an approximately 3.90 mm body width. Place input and output decoupling close to their associated pins, preserve a continuous ground return, and keep the digital host traces away from the line-side analog network to reduce coupling into the modem signal path.

Keep the SPI and UART routes short, use controlled-impedance routing where appropriate, and provide a quiet ground reference beneath digital interface activity. The SI2404-C-FS operates at 4.92 MHz, so the clock path and nearby circuitry require deliberate layout. Follow the manufacturer application circuit for clock and line-side component placement; avoid long parallel runs between the modem interface and sensitive analog nodes, which can increase capacitive coupling and intermittent communication errors.

Do not treat the SI2404-C-FSR, SI2404-C-GTR, or SI2404-C-FT identifiers as interchangeable without checking the exact package, pinout, electrical limits, and ordering suffix. The SI2404-C-FT uses a 24-pin TSSOP rather than the SI2404-C-FS 16-pin SOIC. A valid replacement must also preserve the 3.3 V operating condition, SPI/UART behavior, clocking arrangement, and modem-control functions; matching only the SI2404 family name is insufficient.

Informasi Konformitas

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Qualified
Bebas Logam Lengket
Yes
Bebas Halogena
Unknown
Mineral Konflik
Unknown

RoHS-compliant and lead-free status are explicitly identified for SI2404-C-FS. The SI2404-C-FT comparison identifies no AEC-Q100 qualification, and the target is not listed as automotive qualified.

Data disahkan pada: 2026-11-08 — data disahkan dan disusun oleh tim engineering komponen XAIPART

Pencarian Terkait

SI2404-C-FS datasheet SI2404-C-FS datasheet pdf SI2404-C-FS pinout SI2404-C-FS specifications Skyworks Solutions SI2404-C-FS SI2404-C-FS 16-SOIC modem SI2404-C-FS 2.4 kbps modem SI2404-C-FS SPI UART interface SI2404-C-FS equivalent SI2404-C-FS replacement SI2404-C-FS vs SI2404-C-FT SI2404-C-FS price SI2404-C-FS stock SI2404-C-FS telephone line application

Komponen dan Istilah Terkait

Skyworks Solutions SI2404-C-FS SI2404-C-FT SI2404-C-FSR SI2404-C-GTR ISOmodem modem IC network controller and processor IC interface IC integrated circuit semiconductor V.21 V.22 V.23 V.29 Bell 103 Bell 212A SPI UART 16-pin SOIC SOIC package family surface-mount package RoHS lead-free electronics AEC-Q100 telephone-line telemetry remote monitoring industrial communications 3.3 V logic
Kutipan Cepat RFQ
Isi detail lengkap — tim penjualan kami akan membalas dalam 24 jam
Nomor Part Manufaktur Paket QTY Harga Target Lengkap
✓
Kutipan telah disubmit!

Kami akan membalas email Anda dalam 24 jam

1
RFQ Dikirim
2
Kutipan Diterima
3
Order Ditempatkan
4
Pembayaran
5
Dikirim
6
Dikirim
Lihat Detil RFQ