TCAN330GDCNT - 3.3V 5Mbps CAN FD Transceiver | Texas Instruments
MPN: TCAN330GDCNT ✓ AktifTCAN330GDCNT Ringkasan
A CAN transceiver, also called a CAN physical-layer transceiver, converts logic-level TXD and RXD signals into the differential CAN bus and converts received bus signals into a logic-level RXD output. The TCAN330G family belongs to the Controller Area Network interface hierarchy, combining an ISO 11898-2-compatible CAN physical layer with CAN FD-compatible timing for high-speed industrial, automotive, and embedded communications.
Key features include 3.3 V single-supply operation, operation up to 5 Mbps for TCAN33xG devices, and compatibility with ISO 11898-2. The TCAN330 supports normal, silent, and shutdown operating modes. Silent mode preserves the bus connection while preventing the transmitter from actively driving the bus, which is useful during diagnostic or firmware-update operations. The compact SOT-23-8 package reduces board area in space-constrained control modules.
The device separates controller-side logic from the physical CAN bus through TXD and RXD signals while also providing bus-fault monitoring through open-drain error outputs. Its bus-side architecture is intended to withstand the electrical environment of industrial and automotive networks when paired with the external protection, termination, and common-mode components recommended by the manufacturer. The transceiver does not replace the CAN controller, which handles frame generation, arbitration, acknowledgments, and higher-level protocol functions.
Typical uses include industrial automation controllers, electric-vehicle subsystems, building automation equipment, battery-powered sensors, motor controllers, and embedded gateways. The 5 Mbps capability makes the part suitable for communication links carrying larger CAN FD payloads or operating alongside faster diagnostic and control traffic. Designers should confirm signal timing, bus topology, termination, protection, and operating-temperature requirements for the specific system.
Place the transceiver close to the CAN connector and keep the CANH and CANL routing short, symmetric, and away from sensitive analog or high-speed digital traces. Use the application guidance in the manufacturer datasheet to select termination and common-mode protection. The logic side also requires suitable pull-up or pull-down arrangements where specified for TXD, RXD, and fault outputs.
This product page combines the TCAN330G family operating characteristics with package, sourcing, replacement, and PCB guidance. It also distinguishes the exact TCAN330GDCNT ordering code from related family members so engineers can evaluate compatibility before making a PCB or sourcing decision.
Alternatif penggantian untuk TCAN330GDCNT — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.
TCAN330GDCNR
✅ Drop-InKontak untuk harga
Lihat Datasheet →TCAN330DCNT
✅ Drop-In📋 Alternatif referensi (tidak dalam katalog)
TCAN330GDCNT Spesifikasi
| Product Type | CAN FD Transceiver |
| Tegangan Pemuat | 3.3 V |
| Maximum CAN Data Rate | 5 Mbps |
| CAN Standard Compatibility | ISO 11898-2 |
| Paket | 8-pin SOT-23 (DCN) |
| Jumlah Pin | 8 pins |
| Normal Mode | Supported |
| Silent Mode | Supported |
| Shutdown Mode | Supported |
| Low-Power Standby Mode with Wake | Not specified for TCAN330 |
| CAN Bus Interface | Differential CANH and CANL |
| Tipe Mounting | Surface Mount |
TCAN330GDCNT 8-pin sot-23 (dcn) Diamant Konfigurasi Panduan
Konfigurasi pin untuk TCAN330GDCNT (8-pin sot-23 (dcn) pakai pakai). Penomoran pin, fungsi, dan diagram koneksi ditetapkan dalam datasheet produsen. Lihatnya untuk footprint dan pedoman perpindahan paruh.
Tidak ada data diatribut pin yang tersedia untuk TCAN330GDCNT.
Lihat ke: datasheet produk untuk konfigurasi pin penuh.
Aplikasi Umum
TCAN330GDCNT cocok untuk 6 aplikasis: Industrial PLC and Automation Controller, Automotive Electronic Control Unit, Battery-Powered Sensor Gateway, Electric Motor Controller, Building Automation and HVAC Equipment, Diagnostic and Test Equipment.
Industrial PLC and Automation Controller
The TCAN330GDCNT suits a 3.3 V industrial controller that must communicate with remote actuators, drives, and sensors over a high-speed CAN network. Its 5 Mbps capability provides headroom for CAN FD timing while the 3.3 V single-supply operation simplifies connection to modern embedded processors. The transceiver’s ISO 11898-2 compatibility supports standard high-speed CAN physical signaling. Place the device near the bus connector, follow the manufacturer bus recommendation, and select external termination and common-mode protection based on cable length, ground offsets, and the installation environment.
Direkomendasikan
Automotive Electronic Control Unit
The TCAN330GDCNT provides a compact CAN physical-layer connection for a 3.3 V automotive electronic control unit handling body, comfort, or subsystem information. Its 5 Mbps operation supports CAN FD-compatible communication, while the small SOT-23-8 footprint preserves board area in distributed modules. The design must add the passive and protection components required for automotive transients, ensure the bus and logic grounds meet the vehicle’s grounding architecture, and verify that the exact grade, temperature range, and qualification requirements match the vehicle program.
Direkomendasikan
Battery-Powered Sensor Gateway
The TCAN330GDCNT can connect a low-power sensor gateway to a CAN-based monitoring network when a 3.3 V rail and high-speed physical layer are available. Normal and shutdown operating modes help the firmware manage activity, while silent mode allows the controller to remain attached to the bus without actively driving it. The 5 Mbps rate allows the gateway to participate in networks carrying larger payloads or bursts of diagnostic data. Battery life still depends on the complete system power policy, and the controller should place the device into shutdown whenever bus participation is not required.
Direkomendasikan
Electric Motor Controller
The TCAN330GDCNT is appropriate for a compact 3.3 V motor-control module that exchanges commands and diagnostics over CAN. The 5 Mbps capability can reduce communication latency compared with a 1 Mbps CAN link, while ISO 11898-2 compatibility connects the module to conventional high-speed CAN networks when the bus timing is compatible. Keep CANH and CANL away from motor-drive power stages, use a solid ground strategy, and include transient protection and common-mode components appropriate for the motor environment. Validate timing across the CAN controller, transceiver, cabling, and all connected nodes.
Direkomendasikan
Building Automation and HVAC Equipment
The TCAN330GDCNT enables a space-conscious HVAC controller or building automation gateway to join a 3.3 V CAN-based equipment network. Its SOT-23-8 package supports compact controller boards, while 5 Mbps operation accommodates CAN FD-capable nodes and diagnostic traffic. Normal mode supports regular network participation, silent mode supports receive-only monitoring, and shutdown mode can help reduce consumption when the subsystem is inactive. The installation may require isolation or surge protection across long building cable runs, so validate grounding, bus loading, and protection against the deployment environment.
Direkomendasikan
Diagnostic and Test Equipment
The TCAN330GDCNT fits a portable diagnostic interface that needs to connect a 3.3 V controller to a CAN FD network. The 5 Mbps operating rate permits the equipment to exercise higher-speed CAN FD links, and silent mode is useful during passive bus analysis because the receiver can observe traffic without the transmitter taking control of the bus. The small SOT-23-8 package leaves room for connectors, protection, and user-interface circuitry. Confirm that the diagnostic software and CAN controller are configured for the same bit timing and that cable adapters include the intended termination.
Direkomendasikan
Ringkasan Produk Direkomendasikan
Data referensi engineering untuk TCAN330GDCNT — pembandingan, panduan desain, dan informasi konformitas.
Panduan Pemilihan
Pembandingan dengan Alternatif
| Parameter Umum | Produk Ini | TCAN330GDCNR | TCAN330DCNT |
|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | SOT-23-8 (DCN) | SOT-23-8 (DCN) | SOT-23-8 (DCN) |
| Supply Voltage | 3.3 V | 3.3 V | 3.3 V |
| Maximum Data Rate | 5 Mbps | 5 Mbps | 1 Mbps |
| CAN Standard Compatibility | ISO 11898-2 | ISO 11898-2 | ISO 11898-2 |
| Normal Mode | Supported | Supported | Supported |
| Silent Mode | Supported | Supported | Supported |
| Shutdown Mode | Supported | Supported | Supported |
Diferensiator Kunci
- Higher maximum CAN data rate (vsTCAN330DCNT)
- Exact electrical configuration retained in the reel ordering form (vsTCAN330GDCNR)
- CAN FD-oriented timing in a compact package (vsTCAN330DCNT)
Catatan Desain
Route CANH and CANL as a closely coupled differential pair, keep their geometry consistent, and minimize stubs and test-point discontinuities. Place the transceiver close to the bus connector so external protection components are near the entry point. Keep the CAN interface away from switching nodes, motor-drive traces, and sensitive analog inputs to reduce radiated and susceptibility risks.
Follow the Texas Instruments TCAN330 datasheet when placing the decoupling capacitor and connecting the 3.3 V supply pins. Keep the return path compact and provide adequate source current for normal, silent, and shutdown transitions as well as bus-drive current. Avoid placing high-current return paths beneath the transceiver or between its supply and ground pins because that can increase supply noise and ground bounce.
Do not substitute TCAN330GDCNR blindly for every TCAN330GDCNT assembly without checking reel orientation, pin numbering, and manufacturer ordering conventions. Also do not treat TCAN330DCNT as an equivalent for a 5 Mbps CAN FD link: its family is specified up to 1 Mbps. Confirm bit timing, transceiver mode pins, bus termination, and the complete CAN controller configuration before releasing a replacement.
CAN bus conductors can pick up large external transients even in a 3.3 V system. Use the protection network and grounding arrangement recommended by the manufacturer for the target installation, especially on long cables or automotive and industrial buses. Validate radiated emissions and immunity with the final enclosure, cable routing, connector, and shield configuration rather than only on the bare transceiver board.
Informasi Konformitas
No specific compliance declarations are stated in the manufacturer or distributor result snippets. Confirm RoHS, REACH, lead-free, halogen-free, conflict-minerals, and automotive qualification status in the current manufacturer product documentation before production release.