TJA1054T/S900 Fault-Tolerant CAN Transceiver | NXP
MPN: TJA1054T/S900 ✗ Akhir HidupTJA1054T/S900 Ringkasan
A CAN transceiver, also called a CAN interface controller interface, connects a host controller or microcontroller to the differential CANH and CANL bus. It belongs to the hierarchy of transceiver IC, interface IC, communication semiconductor, and power-management-aware embedded component. The TJA1054T translates logic-level TXD and RXD signals into the physical differential CAN bus, while its receiver converts bus activity back into a logic signal for the host.
The TJA1054 family provides fault-tolerant operation, low electromagnetic emission, and improved matching between the CANH and CANL outputs. NXP identifies the TJA1054T as compatible with the PCA82C252T and TJA1053T, allowing replacement while retaining device functions. The S900 ordering code identifies the specified manufacturing variant and delivery format associated with this MPN.
Fault tolerance is especially valuable in industrial automation, vehicle subsystems, machinery, and distributed control networks where a shorted or misrouted bus wire should not prevent the transceiver from reporting bus activity. The differential bus interface and controlled output characteristics help reduce conducted and radiated interference in equipment containing motors, relays, switching supplies, and long cables.
Typical uses include CAN-based industrial controllers, embedded service modules, machine controllers, building equipment, and vehicle subnets. A host CAN controller drives TXD, while RXD reports received bus data. The WAKE input supports local wake-up detection, and the INH output can activate an external voltage regulator when a wake-up request is recognized, allowing a powered-down system to wake without keeping the entire supply continuously active.
The 14-pin SOIC footprint makes TJA1054T/S900 suitable for conventional leaded PCB assembly. Follow the manufacturer datasheet for the exact pin assignments, termination configuration, decoupling requirements, bus-node limits, timing values, and maximum electrical stress. Confirm the S900 variant, operating temperature grade, lifecycle status, and ordering information before committing a production design.
This product page combines manufacturer compatibility information, package and feature data, substitution guidance, application engineering notes, and a structured comparison for engineers evaluating the TJA1054T/S900. It focuses on practical CAN interface decisions while directing readers to the NXP TJA1054 datasheet for authoritative electrical limits and implementation details.
Alternatif penggantian untuk TJA1054T/S900 — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.
Variasi di dalam seri ini
Model-series yang sama yang kompatibel dengan penggantian TJA1054T/S900 (sama faktor bentuk dan footprint) — berbeda di dalam Package, Product Type, Transceiver Configuration.
TJA1053T/N1
✅ Drop-InKontak untuk harga
Lihat Datasheet →PCA82C252T
✅ Drop-In📋 Alternatif referensi (tidak dalam katalog)
TJA1054T/VM,518
✅ Drop-In📋 Alternatif referensi (tidak dalam katalog)
TJA1054T/S900 Spesifikasi
| Product Type | Fault-tolerant CAN transceiver |
| Transceiver Configuration | 1 transmitter and 1 receiver |
| Paket | 14-pin SOIC (14-SO) |
| Bus Interface | Differential CANH and CANL |
| CAN Termination | Integrated CAN bus termination |
| Local Wake-Up Input | WAKE input |
| Wake-Up Output | INH output for external regulator activation |
| Electromagnetic Emission | Very low EME |
| Host Data Input | TXD logic input |
| Host Data Output | RXD logic output |
| Bus Fault Detection | Fault-tolerant CAN bus operation |
TJA1054T/S900 14-pin soic (14-so) Diamant Konfigurasi Panduan
Konfigurasi pin untuk TJA1054T/S900 (14-pin soic (14-so) pakai pakai). Penomoran pin, fungsi, dan diagram koneksi ditetapkan dalam datasheet produsen. Lihatnya untuk footprint dan pedoman perpindahan paruh.
Tidak ada data diatribut pin yang tersedia untuk TJA1054T/S900.
Lihat ke: datasheet produk untuk konfigurasi pin penuh.
Aplikasi Umum
TJA1054T/S900 cocok untuk 6 aplikasis: Industrial Automation CAN Networks, Vehicle Subsystem Communication, Machine Control Equipment, Building Automation Gateways, Low-Power CAN Sensor Nodes, CAN Diagnostics and Service Interfaces.
Industrial Automation CAN Networks
The TJA1054T/S900 fits industrial automation nodes that connect sensors, motor controllers, remote I/O, and safety-related machinery over a CAN bus. Its fault-tolerant CAN interface is useful when a wiring fault or partially impaired bus could otherwise disrupt communication, while the very low electromagnetic emission helps limit coupling into surrounding control electronics. The integrated termination function simplifies the physical-layer implementation when the board is intended to use the transceiver's onboard termination. Place the 14-pin SOIC close to the CAN connector and route CANH and CANL as a tightly coupled differential pair. NXP documents compatibility with the TJA1053T and PCA82C252T, which can simplify migration from established industrial designs.
Direkomendasikan
Vehicle Subsystem Communication
The TJA1054T/S900 can support CAN communication in a vehicle subsystem where diagnostic access, distributed controls, and long harness branches increase the importance of fault handling. The CAN transmitter and receiver provide the physical interface between a host controller and the differential CANH and CANL network, while the integrated termination option supports conventional bus-node designs. Very low electromagnetic emission is valuable when the transceiver shares a printed circuit board with switching regulators, display electronics, or sensitive sensors. Before selecting the exact S900 grade, verify its automotive qualification and temperature requirements against the manufacturer datasheet. The WAKE and INH function also offers a path to wake a local subsystem without continuously powering every external circuit.
Direkomendasikan
Machine Control Equipment
The TJA1054T/S900 is appropriate for machine-control boards that exchange commands and diagnostics with remote actuators over CAN. Fault-tolerant behavior improves the chance that the interface continues operating when a connector, cable, or termination presents an abnormal condition, while low EME reduces disturbance to adjacent control circuitry. The host processor connects through TXD and RXD, and the transceiver converts the signals to and from the differential physical bus. The 14-pin SOIC package is compatible with conventional through-hole assembly methods used in industrial controllers. Confirm the number of nodes, cable length, termination strategy, and isolation requirements in the system design, and observe the manufacturer's stress limits for bus pins.
Direkomendasikan
Building Automation Gateways
Building-automation gateways often combine CAN-connected sensors, HVAC controllers, access equipment, and service tools on a shared network. The TJA1054T/S900 gives such gateways a fault-tolerant physical interface and low electromagnetic-emission characteristics that help in compact mixed-signal equipment. Its integrated termination can reduce component count where the node is designed to include onboard termination, while the fault-tolerant architecture supports operation in building wiring environments with long branches and multiple connection points. The WAKE input and INH output allow the gateway to activate a local regulator after a wake request. Validate the actual bus topology and termination against the manufacturer reference design, and keep the CAN route separated from switching-node and clock circuitry.
Direkomendasikan
Low-Power CAN Sensor Nodes
The TJA1054T/S900 can be used in a low-power sensor node where CAN bus activity must be detected without keeping the complete node supply active. A local wake-up signal applied to WAKE is detected by the transceiver, and INH can then enable an external regulator for the controller and sensors. This arrangement supports a power-conscious architecture while retaining the CAN physical interface needed for configuration and diagnostic traffic. The host controller still manages normal transmit and receive operation, but the transceiver can preserve a wake path while the system is in a reduced-power state. Confirm wake timing and logic levels in the manufacturer datasheet, and select decoupling and termination values using the documented application circuit rather than general interface assumptions.
Direkomendasikan
CAN Diagnostics and Service Interfaces
The TJA1054T/S900 is useful in diagnostic adapters and service interfaces that connect test equipment or an embedded controller to an existing CAN network. Fault-tolerant operation can improve behavior when the adapter is connected to imperfect harnesses, and the low electromagnetic emission limits interference with nearby test electronics. The standard host-side TXD and RXD signals allow the device to integrate with a CAN controller, while the integrated termination option may simplify service boards configured as active network nodes. Because the S900 variant is obsolete, engineers should confirm whether an exact replacement, a documented family alternative, or a redesigned active interface is required. Any replacement must preserve the 14-pin footprint, bus behavior, and application timing.
Direkomendasikan
Ringkasan Produk Direkomendasikan
Data referensi engineering untuk TJA1054T/S900 — pembandingan, panduan desain, dan informasi konformitas.
Panduan Pemilihan
Pembandingan dengan Alternatif
| Parameter Umum | Produk Ini | TJA1053T | PCA82C252T | TJA1054T/VM,518 |
|---|---|---|---|---|
| Package | SOIC-14 (14-SO) | SOIC-14 (14-SO) | SOIC-14 (14-SO) | SOIC-14 (14-SO) |
| Brand | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors |
| Product Type | Fault-tolerant CAN transceiver | CAN transceiver | CAN transceiver | Fault-tolerant CAN transceiver |
| Transmitter and Receiver Count | 1 transmitter and 1 receiver | 1 transmitter and 1 receiver | 1 transmitter and 1 receiver | 1 transmitter and 1 receiver |
| Fault-Tolerant Operation | Yes | Predecessor without the TJA1054 fault-tolerant improvements | Predecessor without the TJA1054 fault-tolerant improvements | Yes |
| Documented Compatibility | Replaces TJA1053T and PCA82C252T while retaining their functions | Documented predecessor | Documented predecessor | Related ordering option in the TJA1054 family |
Diferensiator Kunci
- Adds fault-tolerant CAN behavior to a documented compatible predecessor (vsTJA1053T)
- Improves fault handling and electromagnetic behavior over the PCA82C252T generation (vsPCA82C252T)
- Retains the same 14-SO physical interface in the related ordering option (vsTJA1054T/VM,518)
Catatan Desain
Route CANH and CANL as a close, tightly coupled differential pair with a continuous reference plane and minimized stub branches. Place the transceiver close to the connector so protection components, common-mode chokes, and termination components can remain in the high-current bus path. Keep the logic-side TXD and RXD traces away from the CAN pair, particularly near switching supplies, relays, and clock sources. The manufacturer's low-EME design reduces emissions but does not replace careful physical-layer layout.
Do not assume that an identical 14-pin footprint guarantees an acceptable replacement. Confirm the S900 ordering suffix, temperature grade, qualification, supply voltage, logic levels, bus timing, termination configuration, and maximum pin stress. NXP specifically states that the TJA1054T is pin and downwards compatible with the PCA82C252T and TJA1053T, so those parts are documented migration candidates. A related TJA1054 ordering option should still be reviewed against the exact production requirements.
Use the manufacturer reference circuit for supply decoupling and verify the available voltage range and local regulator behavior. The WAKE input can detect a local request, and INH can activate an external voltage regulator, which helps avoid continuously powering downstream circuitry. Confirm the WAKE edge and level timing, INH output behavior, and regulator enable thresholds in the NXP datasheet. Ensure the external regulator has suitable startup sequencing and that INH is not used beyond its documented electrical limits.
Termination must be planned for the complete CAN topology rather than added indiscriminately at every node. The TJA1054 family includes a CAN termination capability, but whether it should be enabled depends on the board's position in the bus and the system's termination strategy. Review the manufacturer application diagram, calculate the effective network impedance, and test the completed cable assembly. Incorrect termination can reduce signal margin or prevent the bus from operating reliably.
Informasi Konformitas
No specific compliance declarations are stated in the retrieved manufacturer and distributor information. Confirm RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status for the exact S900 variant before production use.