Hammerspace OFP puts DPU flash into 1U trays for AI storage buyers

Hammerspace is quoting a 1U OFP tray with five DPU flash nodes, rated at 390GB/s of writes and 9.83PB raw, ahead of first-half 2027 shipments.

公開日 更新日 4 分で読了 ✓ AI対応 共有

TL;DR — 3つの文

  • Hammerspace is quoting a five-sled 1U OFP tray rated at 390GB/s of writes without mirroring. (S1)
  • Eight 245.76TB QLC SSDs per sled produce a reported maximum raw capacity of 9.83PB per tray. (S1)
  • Two-way mirroring cuts reported write performance to 195GB/s per tray and usable capacity to about 4.9PB. (S1)

引用元: key_takeaways (実フィールド、最大3件)。事実と分析は別々にラベル付けされています。

Hammerspace OFP puts DPU flash into 1U trays for AI storage buyersEditorial cover for a component sourcing brief. Memory motif; headline "Hammerspace OFP puts DPU flash into 1U trays for AI storage buyers". No reported key numbers on this brief, so no number strip is drawn. 1 cited source. A one-time entrance animation stops under reduced motion.Hammerspace OFP puts DPU flash into 1Utrays for AI storage buyersXAIPART
Cover image generated from data already shown on this page: the category motif, the headline, and reported key numbers. No decorative illustration; no third-party image.

AIの回答から来ましたか — これが検証可能なオリジナルです

AIの要約は、主張の根拠を落としている可能性があります。元の予測、影響を受ける部品、すべての引用はこのページにあり、それぞれ出典まで追跡できます。

XAIPART予測

このブリーフには反証可能な予測が含まれています。

影響を受ける部品

この記事に一致するカタログ項目はありません。推測して一致させるのではなく、何も表示しません。

Reported by StorageReview SSD/NVMe/存储评测与行业新闻 on . Summarized and analyzed by XAIPART Editorial.

What happened

Hammerspace has renamed its software-defined Data Platform the Hammerspace Data System and will sell the software, metadata nodes, and storage as one supported system for the first time.S1 The new hardware centerpiece is the 1U Hammerspace Open Flash Platform, or OFP, which accepts five DPU-based flash nodes without an x86 storage server.S1 Quoting is open, and Hammerspace says the platform will ship in the first half of 2027.S1

Each OFP sled uses the Xsight Labs E1 DPU, a 64-core Arm processor built on TSMC's 5nm process with two 400G MACs and PCIe Gen5.S1 A sled holds eight U.2 or U.3 NVMe SSDs in two removable four-drive packs and has two 400GbE QSFP-DD ports.S1 Hammerspace supports TLC or QLC SSDs on PCIe Gen5 or earlier and presents each sled to its file system as an NFS server.S1

A fully populated tray provides 40 drives, 320 Arm cores, 10 400GbE ports, and 9.83PB of raw capacity when configured with eight 245.76TB QLC SSDs per sled.S1 Maximum power is 360W per sled and 1,800W per tray, while the 106.64cm-deep enclosure requires a 1,200mm rack.S1 The platform also supports IPMI and Redfish management.S1

Hammerspace rates a five-sled tray at 390GB/s of writes without mirroring and 15 million 4K random-read IOPS, using NFSv4.2 with pNFS over TCP, 400GbE, and enterprise Gen5 TLC SSDs.S1 Two-way mirroring reduces write performance to 195GB/s per tray and usable capacity to about 4.9PB, while three-way mirroring reduces writes to 130GB/s.S1 The company has not published OFP latency figures, client counts, or IO500 and MLPerf Storage results, and StorageReview did not test the system.S1

MetricReported valueSource
Maximum raw capacity per tray9.83PBS1
Write throughput, no mirror390GB/s per trayS1
Random-read performance15 million 4K IOPS per trayS1
Maximum tray power1,800WS1
2-way mirror write throughput195GB/s per trayS1
Published latency and client-count dataNot disclosedS1

Background timeline

  1. - Hammerspace started the Open Flash Platform initiative with Xsight Labs and Los Alamos National Laboratory among its participants.S1
  2. - Hammerspace said production systems would become available in early 2026, a schedule that later moved by about one year.S1
  3. - Hammerspace announced the Data System, opened OFP quoting, and scheduled shipments for the first half of 2027.S1

Supply-chain ripple

  1. OFP accepts U.2 and U.3 NVMe SSDs in removable four-drive packs.S1
  2. Removable packs could shorten replacement work, but drive qualification and firmware support would still govern usable configurations.XAIPART analysis
  3. A qualification request for KIOXIA LC9-class QLC capacity should include the tray, network fabric, and protection policy together.XAIPART analysis

XAIPART take

Technical impact

The network path appears more likely to constrain reads than the flash media, because Hammerspace's own estimate places each sled near the limit of its two 400GbE connections.S1 Engineering teams should validate pNFS behavior, protocol overhead, and fabric loss before treating the stated rack-level rate as application throughput.S1

Market impact

Selling a complete system gives buyers a simpler procurement path than assembling storage software, controllers, and support separately.S1 Because the schedule has already slipped, alternate sourcing remains relevant for teams that cannot wait through qualification and delivery risk.S1

Action

Request a quote that specifies drive models, mirroring layout, rack depth, power budget, and expected delivery interval rather than relying on tray-level headline figures.S1 If quoted Hammerspace OFP lead time exceeds 26 weeks by Q2 2027, qualify a second implementation for the same GPU-cluster workload before the next BOM review.XAIPART analysis

XAIPART Forecast

XAIPART expects Hammerspace OFP customer lead times to remain above 26 weeks by Q2 2027 if production deliveries slip beyond the first half of 2027.XAIPART analysis

If published or quoted OFP lead times fall below 26 weeks by Q2 2027, that forecast is wrong; the measure is the customer delivery interval in weeks.XAIPART analysis

Facts are as reported by the cited sources. The design-in, sourcing and forward-looking statements above are XAIPART's analysis, not the sources' claims. Delivery timing and performance remain uncertain because this is a single-source report, pricing was not disclosed, and independent benchmark results are unavailable.

Corrections: none at publication. This brief will be updated with a timestamp if the source corrects its report.

Dated developments, extracted from this page's timeline (curated milestones = hollow markers).
Timeline of dated developmentsDated entries: 2025-01-01 initiative began - Hammerspace sta…; 2025-10-01 2025 - Hammerspace said production…; 2026-11-19 - Hammerspace announced the Data S….2025-01-01initiative began - Hammerspace sta…2025-10-012025 - Hammerspace said production…2026-11-19- Hammerspace announced the Data S…

代替品とライフサイクル

登録済みの代替品 — カタログ範囲であり、市場ランキングではありません
部品関係ライフサイクル根拠
— 登録済みの代替品はありません データ不足 — 前身ラベルを表示するには match_type が必要です

「前身」および「代替」のラベルは、記録された一致タイプ、ライフサイクルステータス、またはソーステキストに基づく場合にのみ付与されます。一致が記録されていない場合、ラベルは表示されません。当社の掲載情報は市場の基準ではありません。

影響を受ける部品

カタログに一致するものはありません。 この記事は、現在XAIPARTに掲載されているどの部品にも該当しません。一致を推測することはなく、プレースホルダーのリストも表示しません。

次元別のコスト圧力

Source: FRED · Generated · reference output z and composite are algorithm outputs, not a fetch snapshot

Cost pressure by dimension — composite stateDiverging bars for three dimensions around a zero midpoint. Input Cost has no reading; Supply Demand z 0.0276, neutral; Fx Energy z -0.0087, neutral. Composite index 0.1, band neutral.0Input costno readingSupply/demandz +0.0276 · neutral48 dFX & energyz −0.0087 · neutral5 dcomposite +0.1 · neutral−100 · −40 · −15 · 0 · +15 · +40 · +100
Underlying values — copyable for verification.
DimensionFRED series IDUnitLagAs of
Input costPCOPPUSDM, PALUMUSDM, PNICKUSDMUSD/mt52 d
Supply/demandPCU334413334413, IPG3344Sindex(1982=100) / index(2017=100)48 d
FX & energyDEXCHUS, DCOILBRENTEU, DHHNGSPrate / USD/bbl / USD/MMBtu5 d

No free authoritative interface for: gold · silver · rare earth · polysilicon · lithium carbonate · market share — listed rather than approximated.

この記事の制作方法

プロセス証跡 — 取得、ソースの妥当性、モデル、ゲート
このブリーフの監査証跡
Source fetched StorageReview SSD/NVMe/存储评测与行业新闻 · www.storagereview.com · 23,676 chars · fetch status success
Source sanity (S1) ok — passed before any model call (no s1_ block recorded)
Model / prompt MiniMax-M3.1-Flash · prompt Blog Agent - News Summary (v3.0.2-news) · 17,272 tokens · 21.8s · run completed
Gate verdict pass · 6/6 applicable checks passed · spec v2.9 · C10 ratio 0.005215 · C10 rounds 0
Time contract 4 <time datetime> values in this brief — 0 violations (+08:00 or date-only)

上記のすべての行はパイプラインによって生成されており、手作業で書かれたものではありません。

編集スコア

決定論的ゲートの結果 — 純粋なPHPで、判定にモデルは関与していません
ゲートスコアの内訳 6 件の該当チェックのうち、 6項目合格: 100 %. No hold items or mandatory failures. Gate spec: v2.9 (S0 + S1 + C1–C20) · Source affinity (C20): 0.9. 該当するチェックに合格 6 / 6 = 100% · 判定: pass No hold items or mandatory failures Gate spec: v2.9 (S0 + S1 + C1–C20) · Source affinity (C20): 0.9 公開の可否はゲートが決定します。独立監査スコアは助言にすぎません。
誤りを見つけましたか? 誤りをお知らせください — 訂正は原文と併せて公開され、記録されます。記事を無断で編集することはありません。

コメント

最初のコメントを投稿しましょう。

情報源

  1. Hammerspace Data System Launches With OFP, a 1U DPU Flash Tray Rated at 390GB/s and Up to 9.83PB — https://www.storagereview.com/news/hammerspace-data-system-open-flash-platform-ofp-dpu-flash-xsight-e1 · rss · 参照日

事実はS1/S2とマークされ、リンクされた出典まで追跡できます。ラベル付けされた箇所は 分析 はXAIPART独自の推論であり、報道された事実とは分けて維持されています。出典リンクは実際に参照され、次の指定は行いません: nofollow — 帰属表示は意図的なものです。