DS2450S+ vs DS2450S 比較

詳細な並列比較: DS2450S+ メーカー: Analog Devices および DS2450S メーカー: Analog Devices。主要仕様、電気的特性、パッケージ、ライフサイクルステータス、価格、在庫状況を比較して、設計要件に最適な部品を判断してください。

Analog Devices
DS2450S+ DS2450S+ - 16-Bit 1-Wire Quad ADC | Analog Devices

DS2450S+ - 16-Bit 1-Wire Quad ADC | Analog Devices

DS2450S+ Obsolete

仕様比較

パラメータ DS2450S+ DS2450S
ブランド Analog Devices Analog Devices
カテゴリ ADC/DAC ADC/DAC
ライフサイクル状態 Obsolete NRND
分解能 16 bit 16 bit
Number of Input Channels 4 —
Architecture Successive Approximation (SAR) —
Digital Interface 1-Wire (Dallas Semiconductor proprietary, single-wire bi-directional) —
Supply Voltage (VCC) 2.8 V to 5.25 V [DATA_NEEDED: confirm in datasheet electrical characteristics] —
入力電圧範囲 0 to 5.12 V / 0 to 2.56 V / ±5.12 V / ±2.56 V (software-selectable) 0 V to 2.56 V or 0 V to 5.12 V (user-programmable per channel)
Conversion Time (per conversion, 12-bit) 80 µs typical + 160 µs overhead per channel —
Conversion Time (4 channels × 16-bit) 4 × 16 × 80 µs + 4 × 160 µs ≈ 5.8 ms [DATA_NEEDED: confirm exact value in datasheet] —
On-chip Reference Internal bandgap [DATA_NEEDED: VREF value] —
ROM ID 64-bit unique factory-lasered serial number —
Per-channel Configuration Voltage range, resolution, offset/gain calibration, alarm thresholds —
Conditional Search Per-channel over/under threshold flags supported Yes (per-channel alarm flag participation)
動作温度 -40 °C to +85 °C (industrial grade) -40C to +85C (industrial)
パッケージ 8-pin SOIC (S) 8-pin SOIC (SO-8)
実装タイプ Surface Mount —
RoHS ステータス Compliant [DATA_NEEDED: confirm from manufacturer page] [DATA_NEEDED: RoHS compliance]
Number of Channels — 4 input / 1 ADC (4-to-1 mux)
ADC Architecture — Successive Approximation (SAR)
Programmable Resolution — 1 to 16 bits per channel
Communication Interface — Dallas 1-Wire (single-wire, parasitic-power capable)
電源電圧 — 5 V single supply (parasitic or external VCC)
Active Power Consumption — 2.5 mW (typical)
Idle Power Consumption — 25 µW (typical)
Unique Serial Number — 64-bit 1-Wire ROM ID (per device)
On-chip Memory — SRAM for per-channel range/resolution/alarm settings
Power-on Reset Flag — Yes (master detects need to restore settings)

データシート&リソース