MAX1154AEUE+T vs MAX116CAX 比較
詳細な並列比較: MAX1154AEUE+T メーカー: Maxim Integrated および MAX116CAX メーカー: Maxim Integrated。主要仕様、電気的特性、パッケージ、ライフサイクルステータス、価格、在庫状況を比較して、設計要件に最適な部品を判断してください。
Maxim Integrated
MAX1154AEUE+T - 10-Ch 10-Bit System Monitor ADC | Maxim Integrated
MAX1154AEUE+T ✓ 生産中仕様比較
| パラメータ | MAX1154AEUE+T | MAX116CAX |
|---|---|---|
| ブランド | Maxim Integrated | Maxim Integrated |
| カテゴリ | ADC/DAC | ADC/DAC |
| ライフサイクル状態 | 有効 | NRND |
| 在庫状況 | In Stock | In Stock |
| 単価(USD) | $4.45 | $10.80 |
| 機能 | 10-bit system-monitor ADC with internal temperature sensor and VDD monitor | — |
| Number of Channels | 10 (8 external analog + 2 internal: temperature, VDD) | 2 x 4 (eight single-ended) |
| 分解能 | 10 bit | 12 bit |
| サンプリングレート | 94 ksps (auto mode, single channel) | — |
| Analog Supply Voltage | 2.7 V to 5.25 V | — |
| Analog Input Range | 0 V to VREF (single-ended) | — |
| Internal Reference Voltage | 2.5 V (typ) | — |
| 電源電流 | 1.7 mA at 3 V (94 ksps, single channel); 190 uA at 2 ksps; < 8 uA at 50 sps (AutoShutdown) | — |
| Operating Power | 5 mW at 3 V / 94 ksps | — |
| Digital Interface | SPI / QSPI / MICROWIRE-compatible serial | — |
| ALERT Output | Yes (out-of-threshold interrupt) | — |
| 動作温度範囲 | -40 C to +85 C | — |
| パッケージ | 16-pin TSSOP, 4.4 mm body width, 1.1 mm height, surface mount | 36-pin SSOP (CAX) |
| 実装タイプ | Surface Mount | — |
| ADC Architecture | SAR (successive approximation) | — |
| AutoShutdown | Yes | — |
| RoHS ステータス | Compliant | [DATA_NEEDED: RoHS compliance status] |
| Sampling Architecture | — | Simultaneous-sampling SAR with 4 T/H amplifiers |
| Conversion Time per Channel | — | 2 us |
| Throughput (1 channel active) | — | 390 ksps |
| Throughput (2 channels active) | — | 218 ksps |
| Throughput (3 channels active) | — | 152 ksps |
| Throughput (4 channels active) | — | 116 ksps |
| Analog Input Type | — | Single-ended, 2x 4-channel multiplexed banks |
| Terminal Form | — | Gull wing |
| Package Shape | — | Rectangular |
| Temperature Grade | — | Industrial |
| 動作温度 | — | [DATA_NEEDED: operating temperature range] |
| 電源電圧 | — | [DATA_NEEDED: AVDD/DVDD nominal and range] |
| Architecture | — | Successive Approximation Register (SAR) |