1336F-BRF75-AA-EN - 7.5 HP 460V AC Drive | Allen-Bradley
部品番号: 1336F-BRF75-AA-EN ✗ 生産終了| 数量 | 単価 | 小計 |
|---|---|---|
| 1 | $0 | $0.00 |
| 10 | $0 | $0.00 |
| 100 | $0 | $0.00 |
| 500 | $0 | $0.00 |
| 1,000 | $0 | $0.00 |
1336F-BRF75-AA-EN 概要
An adjustable-frequency AC drive, commonly called a variable-frequency drive or VFD, is a power-management device that varies motor output frequency and voltage to control motor speed, torque, and process behavior. It sits between the industrial power supply and the motor, using power electronics and control firmware to manage startup, stopping, acceleration, deceleration, protection, and communication commands. The 1336 PLUS II family provides a common control interface and maintenance approach across a broad drive range.
For this catalog number, the verified specifications identify 7.5 hp constant-torque capability, 380–480 V AC input, 513–620 V DC input, and NEMA Type 1 enclosure. Search results also describe the unit as an Allen-Bradley 1336 PLUS II adjustable-frequency drive. The available data does not establish every electrical, environmental, communication, or mechanical parameter, so those fields should be confirmed against the applicable Rockwell literature before procurement or installation.
Typical uses include pumps, fans, compressors, conveyors, mixers, and other three-phase motor loads in industrial plants. The drive can be selected where speed regulation is needed instead of fixed-speed operation. Configuration details, terminal assignments, and diagnostics should be taken from the manufacturer documentation rather than inferred from an aftermarket listing.
A critical procurement check is the complete catalog number. Rockwell drives are configured systems rather than simple interchangeable semiconductors, and the enclosure, language, control options, voltage class, and power rating must all be verified. The verified sources include a 1336 PLUS II technical document and user manual.
This page consolidates verified source excerpts, application guidance, and replacement-screening limits. It does not substitute for the manufacturer technical data, installation instructions, or a site-specific motor and protection study.
ドロップイン代替品: 1336F-BRF75-AA-EN — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
クイック比較ツール — 並列比較する代替部品を選択:
この製品に利用可能なドロップイン代替品はありません。
代替品をリクエスト1336F-BRF75-AA-EN 最大定格&電気的特性
| Product Type | Adjustable-frequency AC drive |
| Product Series | 1336 PLUS II |
| Rated Power | 7.5 hp constant torque; 10 hp variable torque |
| Input Voltage | 380–480 V AC |
| DC Input Voltage | 513–620 V DC |
| Input Phase | Three-phase |
| Enclosure | NEMA Type 1 |
| Enclosure Protection | IP20 |
| Language | English |
| Motor Control Method | Adjustable frequency |
| Nominal Motor Power | 5.5 kW |
| AEC-Q100 Qualification | not_applicable |
1336F-BRF75-AA-EN standard ピン配置ガイド
1336F-BRF75-AA-EN (standard パッケージ) のピン配置。 このパワーデバイスは、ゲート、ドレイン、ソース端子を備えています。非極性パッケージの場合、正確なピン1の向きとフットプリントの詳細については、メーカーのデータシートを参照してください。主な用途には、電源設計、モータ駆動、負荷スイッチングがあります。
詳細なピン配置データはありません: 1336F-BRF75-AA-EN.
詳細は データシート をご参照ください。
主な用途
1336F-BRF75-AA-EN の用途: 6 件s: Industrial Pump Control, Fan and HVAC Speed Regulation, Conveyor and Material Handling, Compressor and Pumping Equipment, Mixer and Agitator Drives, Legacy Motor-Control Retrofit.
Industrial Pump Control
The 1336F-BRF75-AA-EN is suitable for a properly engineered three-phase pump application where adjustable speed is useful for flow or pressure control. Its verified 7.5 hp constant-torque class, 380–480 V AC input, and NEMA Type 1 enclosure support use in an industrial control panel, but the motor nameplate, pump starting current, minimum frequency, and process torque must be checked. Configure acceleration and deceleration to limit mechanical shock and water hammer. Confirm that the selected motor and drive are sized together rather than relying only on horsepower.
おすすめ
Fan and HVAC Speed Regulation
The drive can regulate a compatible three-phase fan motor for industrial ventilation, process airflow, or HVAC equipment when variable speed is required. The 380–480 V AC input class and adjustable-frequency architecture allow the motor speed to be matched to airflow demand, potentially avoiding unnecessary energy use compared with fixed-speed operation. Verify motor current, fan starting torque, minimum stable speed, enclosure requirements, and the permitted ambient conditions before installation. A drive catalog rating does not by itself establish safe operation at every output frequency.
おすすめ
Conveyor and Material Handling
The 1336F-BRF75-AA-EN can be considered for conveyor drives requiring controlled startup, speed adjustment, and motor protection in an industrial handling line. The verified 7.5 hp constant-torque rating provides a defined catalog basis for sizing review, while the 380–480 V AC input supports common three-phase industrial systems. Actual suitability depends on conveyor inertia, starting torque, belt loading, regenerative behavior, duty cycle, and the motor's rated current. Commissioning should include controlled acceleration and emergency-stop validation.
おすすめ
Compressor and Pumping Equipment
The drive may be used with a compatible compressor or pumping load where adjustable motor speed supports process matching and controlled loading. The 1336 PLUS II platform's adjustable-frequency operation is more relevant than a fixed-voltage starter when the process requires gradual acceleration, load modulation, or reduced mechanical shock. Verify compressor torque demand, current at low speed, acceleration time, motor cooling, voltage class, and protection settings. Do not use the 7.5 hp rating without checking the compressor manufacturer's minimum-speed and torque requirements.
おすすめ
Mixer and Agitator Drives
The 1336F-BRF75-AA-EN is relevant to mixer or agitator systems that need adjustable speed for batch control, blending, or process matching. The drive's 7.5 hp constant-torque class should be checked against the mixer's starting torque, inertia, duty cycle, and motor current rather than treated as a universal rating. A NEMA Type 1 enclosure indicates suitability for an indoor industrial environment, but the verified data does not specify the complete environmental limits. Confirm motor insulation, cable length, grounding, and control parameters during commissioning.
おすすめ
Legacy Motor-Control Retrofit
The 1336F-BRF75-AA-EN can be evaluated for a retrofit that replaces older adjustable motor-control equipment while retaining a Rockwell-oriented control architecture. A retrofit is only appropriate when the replacement has the required voltage, power, duty, enclosure, terminal, communications, and control-function compatibility. The verified data describes the unit as a 1336 PLUS II drive with English documentation, but it does not provide a complete cross-reference to every legacy installation. Perform a field audit and review the Rockwell user manual before reusing wiring or control assumptions.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: 1336F-BRF75-AA-EN — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 |
|---|---|
| Brand | Rockwell Automation / Allen-Bradley |
| Product Type | Adjustable-frequency AC drive |
| Power Rating | 5.5 kW; 7.5 hp constant torque; 10 hp variable torque |
| Input Voltage | 380–480 V AC three-phase; 513–620 V DC |
| Enclosure | NEMA Type 1; IP20 |
| Language | English |
| Series | 1336 PLUS II |
| Package | Industrial drive enclosure; exact mechanical package not supplied |
| Motor Control | Adjustable frequency |
| Price | Current numeric price not supplied |
主な差別化要因
- Defined 7.5 hp constant-torque catalog rating (vs 1336F-AQF75-AA-EN)
- NEMA Type 1/IP20 enclosure specification (vs 1336F-CWF75-AA-EN)
- Rockwell 1336 PLUS II documentation context (vs 1336F-BRF75-AA-EN-L5)
設計ノート
Before installation, verify that the plant supply matches the catalog input range of 380–480 V AC three-phase or 513–620 V DC. Confirm the disconnect, protective device, grounding conductor, motor voltage, and cable routing against the applicable 1336 PLUS II documentation. Do not treat the distributor's input-voltage listing as a substitute for checking the nameplate and local electrical code.
The verified data provides the NEMA Type 1/IP20 enclosure rating but does not provide ambient-temperature limits, duty-cycle details, or thermal-resistance values. Install the drive within its specified environmental limits and maintain the required clearance around the enclosure. For pump, fan, and compressor loads, verify motor cooling at low speed because reduced-speed operation can increase motor heat.
The most consequential procurement error is treating a similar Allen-Bradley catalog number as automatically interchangeable. Compare the complete catalog number, horsepower, voltage class, enclosure, control language, option modules, communications, terminal functions, and firmware requirements. The verified data does not establish a drop-in replacement, so wiring and programming must be reviewed before substitution.
Use the manufacturer's terminal drawings and user manual for control and power wiring. Keep signal wiring separate from high-current motor and power conductors, route control cables with appropriate separation, and verify grounding continuity. The verified data does not include a complete pinout or terminal map, so technicians should not infer TB1 or TB2 assignments from aftermarket listings.
Commissioning should begin with the motor disconnected where permitted and proceed through displayed faults, parameter review, input-side checks, and controlled no-load operation before connecting the process load. Set acceleration, deceleration, minimum frequency, maximum frequency, current limits, and motor data from the actual motor and driven-machine requirements. Record the final configuration for maintenance and replacement records.
コンプライアンス情報
The supplied web results identify the product as an industrial Allen-Bradley/Rockwell Automation AC drive but do not provide verified RoHS, REACH, lead-free, halogen-free, or conflict-minerals statements. AEC-Q100 is not applicable to this industrial drive category.