AD7579KP - 10-Bit Dual-Input SAR ADC | Analog Devices
部品番号: AD7579KP ✗ 生産終了AD7579KP 概要
An analog-to-digital converter is an interface IC that converts continuous voltage signals into digital codes for processing by a microcontroller, DSP, PLC, or host computer. Within the signal-chain hierarchy, an ADC sits between sensors and digital control logic. The AD7579 belongs to the successive-approximation ADC class, which repeatedly compares the input voltage with an internal reference and successively determines each output bit. Compared with flash ADCs, this architecture is well suited to compact, cost-sensitive designs that do not require extremely high conversion rates.
The AD7579KP provides 10-bit resolution, two analog inputs, and one SAR conversion channel. Its documented input ranges include 0 to +2.5 V, 0 to +5 V, and a bipolar 2.5 V range, while operation from a single +5 V supply simplifies system power planning. The converter uses LC2MOS circuitry and a commercial temperature grade. These characteristics make it appropriate for industrial process measurement, transducer interfaces, panel instrumentation, and embedded control systems requiring repeatable digital measurement from low-voltage analog sources.
The device's +5 V analog supply requirement and selectable input ranges allow one converter design to serve multiple sensor and signal-conditioning arrangements. A 10-bit code provides 1,024 distinct digital levels, making channel resolution a key design consideration when defining the least significant bit for the selected input range. The two analog inputs also permit multiplexed measurements when the application supports sequential sampling and the source impedance remains suitable for the SAR input network.
Typical uses include PLC analog-input modules, temperature and pressure transmitter interfaces, battery-operated industrial instruments, data loggers, and embedded factory-control equipment. For a transmitter with a 0 to +5 V output, the AD7579KP can map the signal directly into its corresponding input range. For a bipolar sensor, the bipolar 2.5 V option reduces the need to translate the signal into a unipolar domain before conversion.
Design the analog input path to minimize switching noise and sampling-charge errors. Keep the input driver close to the converter, use a suitable reference and supply-decoupling network, and verify acquisition time against the source impedance. The PLCC package also requires attention to through-hole footprint accuracy and soldering assembly because the package does not provide the compact thermal and layout advantages of a leadless surface-mount ADC.
This page combines the AD7579KP's confirmed resolution, channel, conversion architecture, input-range, supply, and package characteristics with practical guidance for analog front ends, acquisition circuits, PCB implementation, and drop-in replacement assessment. The comparison and design notes highlight where footprint, sampling behavior, and operating requirements must be checked before assigning a substitute.
ドロップイン代替品: AD7579KP — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
この製品に利用可能なドロップイン代替品はありません。
代替品をリクエストAD7579KP 最大定格&電気的特性
| 分解能 | 10 bit |
| Analog Input Channels | 2 inputs |
| Conversion Architecture | 1-channel successive approximation (SAR) |
| 電源電圧 | +5 V |
| Unipolar Input Range 1 | 0 V to +2.5 V |
| Unipolar Input Range 2 | 0 V to +5 V |
| Bipolar Input Range | ±2.5 V |
| Input Type | Unipolar or bipolar |
| Process Technology | LC2MOS |
| パッケージ | 28-pin PLCC |
| Package Dimensions | 11.51 mm × 11.51 mm |
| Package Code | QCCJ |
| Package Shape | Square |
| Terminal Form | J-bend |
| Temperature Grade | Commercial |
AD7579KP square ピン配置ガイド
AD7579KP (square パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: AD7579KP.
詳細は データシート をご参照ください。
主な用途
AD7579KP の用途: 6 件s: PLC Analog Input Module, Industrial Pressure Transmitter Interface, Embedded Data Acquisition System, Process Control Monitor, Battery-Powered Field Instrument, Laboratory Measurement Front End.
PLC Analog Input Module
The AD7579KP is suitable for a PLC or industrial controller that must digitize low-level process signals. Its two analog inputs support sequential measurement of two sensors, while the selectable 0 V to +2.5 V and 0 V to +5 V ranges accommodate different transmitter outputs. The 10-bit converter provides 1,024 codes per conversion, which is useful when the required control resolution is moderate rather than precision laboratory-grade. Place input conditioning, protection, and reference-decoupling components near the 28-pin PLCC, and verify that each source can charge the internal sampling capacitor during the available acquisition interval. Because the PLCC is a through-hole package, the board layout must also preserve mechanical clearance and solder-joint reliability.
おすすめ
Industrial Pressure Transmitter Interface
The AD7579KP can digitize the output of a pressure or temperature transmitter that operates within the converter's supported input range. A 4-20 mA transmitter commonly produces a scaled 0 V to +5 V signal after termination and signal conditioning, allowing the AD7579KP's 0 V to +5 V range to minimize analog conversion stages. The 10-bit result may be sufficient for supervisory control and status indication, although calibration and sensor accuracy can limit overall system precision. For industrial deployment, include input overvoltage and surge protection ahead of the converter, maintain a stable reference, and route analog returns away from switching nodes. Verify the acquisition interval against the output impedance of the transmitter and the input-filter network.
おすすめ
Embedded Data Acquisition System
The AD7579KP fits embedded data-acquisition boards that need to capture two analog channels through a simple 10-bit SAR interface. It can monitor temperature, level, or position feedback in machinery while a microcontroller reads each conversion result over the device's digital interface. The single +5 V supply supports integration with legacy control logic, and the 0 V to +2.5 V range is useful for low-energy sensor front ends. Designers should budget adequate acquisition time, keep the source impedance within the converter's requirements, and isolate the analog input path from digital switching activity. The 28-pin PLCC footprint is particularly useful when maintaining an existing through-hole industrial controller; new compact products should additionally assess whether a smaller leadless ADC would simplify routing and assembly.
おすすめ
Process Control Monitor
The AD7579KP can serve as the measurement front end in a process-control monitor that watches one or two slowly changing analog variables. Its successive-approximation architecture is appropriate for temperature, pressure, flow, and level monitoring where high-frequency waveform fidelity is not the primary requirement. Select the input range that maximizes use of the converter's 10-bit code space, then define software scaling around the calibrated sensor limits. Because the PLCC package and +5 V supply arrangement are established catalog characteristics, the converter can be attractive for maintenance-oriented legacy equipment. The PCB should still provide local decoupling, a quiet reference distribution path, protective components, and adequate separation between analog inputs and digital control traces.
おすすめ
Battery-Powered Field Instrument
The AD7579KP can support a field instrument that measures two low-voltage analog channels from a +5 V system rail. The 0 V to +2.5 V input range can match battery-scaled sensor outputs and reduce the need for a larger signal swing, while 10-bit resolution is often appropriate for field-service displays, threshold alarms, and simple data logging. Power budgeting should include the converter's supply current and the dissipation of any input or reference network. The selected input range also determines the useful code increment, so sensor noise and reference stability must be compared with the resolution needed by the application. In a portable enclosure, protect the connector and analog front end from moisture and electrostatic discharge without adding excessive leakage to the sensor source.
おすすめ
Laboratory Measurement Front End
The AD7579KP can be used in a laboratory measurement front end when 10-bit resolution, dual analog inputs, and +5 V operation align with the instrument architecture. It is appropriate for teaching systems, status monitors, and compact instrumentation rather than high-accuracy laboratory analysis. A ±2.5 V input supports centered signals without first shifting them to a unipolar range, while the 0 V to +5 V mode simplifies direct connection to certain sensors. To obtain repeatable results, provide a stable reference, appropriate input filtering, and a low-impedance driver. Calibrate gain and offset after installation, and compare the converter's 10-bit code width with the required measurement uncertainty. For new precision instruments, a higher-resolution converter may reduce calibration and noise complexity.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: AD7579KP — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 |
|---|---|
| Package | 28-pin PLCC (QCCJ) |
| Brand | Analog Devices |
| Resolution | 10 bit |
| Analog Inputs | 2 inputs |
| Conversion Architecture | 1-channel successive approximation (SAR) |
| Supply Voltage | +5 V |
| Input Ranges | 0 V to +2.5 V, 0 V to +5 V, and ±2.5 V |
| Temperature Grade | Commercial |
主な差別化要因
- Dual-input 10-bit SAR conversion in an established PLCC footprint (vs AD7580)
- Single +5 V operation with flexible input ranges (vs AD7579ARZ)
- Commercial-grade legacy industrial positioning (vs AD7580)
設計ノート
Design the analog front end around the SAR acquisition interval. Place the input filter and protection network close to the AD7579KP, and verify that the driving circuit can charge the converter's sampling network during the allowed acquisition time. High source impedance increases settling error and can make the first conversion after channel selection differ from subsequent results. Ground analog input returns directly to the converter's quiet analog ground and keep switching-regulator paths away from the input pins.
Use a clean +5 V supply and local bypass capacitors at the converter's supply pins. Keep the analog and digital grounding strategy consistent with the manufacturer application guidance so the reference and input signals are not corrupted by digital return current. Check the converter's settling behavior before startup conversions are used for control decisions. If the input range can be switched, allow the source and filter to settle before treating the first result as a valid measurement.
Treat the 28-pin PLCC footprint as a through-hole mechanical and soldering interface. Match pin numbering and body size against the manufacturer drawing, allow adequate clearance for the J-bend leads, and verify the board's thermal and vibration requirements. Do not assume that a functionally similar PLCC converter is pin-compatible. For a replacement, compare every pin, the exposed analog references, interface timing, supply sequencing, and acquisition characteristics before releasing the PCB change.
Do not calculate system accuracy from the 10-bit resolution alone. Include reference-voltage error, converter nonlinearity, input noise, sensor error, and calibration uncertainty in the measurement budget. The 0 V to +5 V range provides a smaller code increment than the 0 V to +2.5 V range, so the selected range should match the signal to avoid sacrificing useful resolution. Also verify that bipolar operation has the correct reference and input arrangement required by the AD7579 documentation.
コンプライアンス情報
The AD7579KP is a commercial-grade data-conversion IC. No specific RoHS, REACH, lead-free, halogen-free, or conflict-minerals declaration was confirmed for this exact package suffix.