AD7712ANZ - 24-Bit Sigma-Delta ADC | Analog Devices
部品番号: AD7712ANZ ✓ 生産中AD7712ANZ 概要
A sigma-delta ADC is a type of analog-to-digital converter that uses continuous-time oversampling, digital filtering, and noise shaping to produce high-resolution results at relatively low conversion rates. Within the ADC hierarchy, the AD7712 is a precision signal-conditioning ADC with integrated programmable gain and digital calibration functions. Its architecture is suited to sensors whose useful bandwidth is low but whose amplitude accuracy must be high.
The AD7712ANZ provides 24-bit resolution, differential input capability, programmable gain, selectable analog input channels, and software-configurable signal polarity and conversion settings. According to the manufacturer product page, input-channel selection, gain settings, and polarity can be configured through the bidirectional serial interface. One distributor listing identifies a maximum conversion rate of 1.028 kSPS, while another product listing states 19.5 kSPS; these figures may represent different operating modes or characterization conditions and should be checked against the required output-data-rate configuration in the datasheet.
The device uses a sigma-delta conversion technique designed to achieve up to 24 bits of no-missing-code performance. Its analog input section supports low-level signals from transducers, while the reference and input arrangement supports system calibration. The serial digital interface allows connection to microcontrollers and other embedded processors. Industrial temperature operation makes the converter suitable for measurement equipment that must operate beyond typical commercial-room conditions.
Typical uses include precision pressure and temperature measurement, industrial process monitoring, weighing systems, bridge-sensor instrumentation, laboratory data acquisition, and low-frequency sensor acquisition. The AD7712 is especially appropriate when the measured signal changes slowly, resolution and input conditioning matter more than high sample throughput, and a through-hole industrial package is acceptable.
Design carefully around the analog and digital supply rails, reference voltage, input common-mode range, filtering configuration, and digital interface timing. Use the manufacturer pin-description table when assigning PCB signals and preserve the recommended grounding and decoupling arrangement. Because the converter can accept both direct low-level signals and amplified signals, the input network must be selected for the actual transducer output rather than configured by nominal resolution alone.
ドロップイン代替品: AD7712ANZ — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: AD7712ANZ (同一形状・フットプリント) — 相違点: Mounting Type, Resolution, Package, Converter Type, Digital Interface.
AD7712AN
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →AD7712ARZ
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →AD7712BNZ
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
AD7712AYZ
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
AD7712ANZ 最大定格&電気的特性
| Converter Type | 24-bit sigma-delta ADC |
| 分解能 | 24 bits |
| Analog Input Channels | 2 channels |
| Conversion Channel Count | 1 differential input |
| Maximum Conversion Rate | 1.028 kSPS |
| Advertised Maximum Rate | 19.5 kSPS |
| Input Configuration | Differential, low-level or high-level input |
| Analog Supply Voltage | 4.75 V to 10.5 V |
| Digital Interface | Bidirectional serial interface |
| Integrated Signal Conditioning | Programmable gain and software-configurable polarity |
| No-Missing-Code Performance | Up to 24 bits |
| 動作温度 | -40°C to +85°C |
| Temperature Grade | Industrial |
| パッケージ | 24-pin PDIP |
| 実装タイプ | Through-hole |
| Package Width | 0.300 inch, 7.62 mm |
AD7712ANZ 0.300 inch, 7.62 mm ピン配置ガイド
AD7712ANZ (0.300 inch, 7.62 mm パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: AD7712ANZ.
詳細は データシート をご参照ください。
主な用途
AD7712ANZ の用途: 6 件s: Industrial Pressure Measurement, Temperature Measurement Systems, Bridge-Based Weighing Systems, Laboratory Data Acquisition, Process-Control Monitoring, Embedded Sensor Acquisition.
Industrial Pressure Measurement
The AD7712ANZ fits industrial pressure transmitters that produce small differential signals and require high-resolution digital readings. Its 24-bit sigma-delta conversion, programmable gain, and differential input stage support low-level transducer measurements while reducing quantization uncertainty. In a transmitter front end, the converter can digitize the bridge or pressure-sensor output for transmission to a controller. The 1.028 kSPS listed maximum rate is suitable for slowly changing pressure signals. Designers should verify common-mode range, reference stability, digital filtering, and calibration behavior against the pressure-sensor excitation and mechanical bandwidth.
おすすめ
Temperature Measurement Systems
The AD7712ANZ is appropriate for precision temperature monitoring using resistive, thermocouple-like, or other slow-changing low-level signals. Its differential input, programmable gain, and up to 24-bit no-missing-code performance provide useful resolution beyond ordinary general-purpose converters. The device can serve as the acquisition stage in a temperature transmitter or laboratory recorder. Its -40°C to +85°C industrial rating supports equipment deployed outside controlled rooms, although measurement accuracy also depends on sensor stability, cold-junction compensation where applicable, reference quality, and periodic calibration.
おすすめ
Bridge-Based Weighing Systems
The AD7712ANZ is suited to electronic weighing platforms that use a load-cell bridge and require resolution beyond a conventional 12-bit or 16-bit ADC. Differential input and programmable gain help condition the small millivolt-level bridge signal, while 24-bit conversion preserves fine resolution after scaling. In a weighing controller, the converter can sample the bridge during controlled excitation and transfer each result through its serial interface. Design effort should center on bridge excitation stability, common-mode compatibility, input protection, filtering, offset-and-gain calibration, and mechanical vibration rejection.
おすすめ
Laboratory Data Acquisition
The AD7712ANZ can serve as the precision conversion element in laboratory instruments that measure low-frequency analog quantities with substantial dynamic-range requirements. Its 24-bit resolution, selectable gain, and differential input reduce the complexity of a discrete front end, while the bidirectional serial interface simplifies communication with a microcontroller-based control system. The conversion architecture is most appropriate for temperature, pressure, force, and slowly varying laboratory signals. Instrument designers should select filter bandwidth and output-data rate carefully, isolate analog and digital return paths, and account for reference drift during long measurement cycles.
おすすめ
Process-Control Monitoring
The AD7712ANZ is useful for monitoring slow process variables where accurate trend information matters more than high-frequency sampling. A transmitter can apply the converter to a low-level differential sensor output and provide the digitized value to a PLC or embedded controller. Two analog input channels permit software-controlled channel selection, while programmable gain allows one converter to serve sensors with different signal levels. The 24-pin PDIP package supports repairable and through-hole industrial assemblies. System integration requires electrical isolation or protection as appropriate, surge handling, calibration procedures, and control-loop bandwidth matched to the selected converter data rate.
おすすめ
Embedded Sensor Acquisition
The AD7712ANZ fits embedded systems that acquire slow sensor signals and need more precision than an internal microcontroller ADC commonly delivers. The converter provides configurable channel selection, gain, and polarity through a bidirectional serial port, allowing firmware to configure the measurement path and retrieve results. It is particularly useful in instrumentation built around bridge sensors, resistive sensors, or precision transducers. Firmware must establish the correct gain, filter, and calibration state before each reading. The PCB should provide local decoupling, controlled reference routing, adequate analog grounding, and separation between serial-interface return current and sensitive input traces.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: AD7712ANZ — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | AD7712AN | AD7712ARZ | AD7712BNZ | AD7712AYZ |
|---|---|---|---|---|---|
| Package | 24-pin PDIP | 24-pin PDIP | 24-pin PDIP | 24-pin PDIP | 24-pin PDIP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Resolution | 24 bits | 24 bits | 24 bits | 24 bits | 24 bits |
| Converter Architecture | Sigma-delta | Sigma-delta | Sigma-delta | Sigma-delta | Sigma-delta |
| Analog Input Channels | 2 channels | 2 channels | 2 channels | 2 channels | 2 channels |
| Conversion Channels | 1 differential input | 1 differential input | 1 differential input | 1 differential input | 1 differential input |
| Digital Interface | Bidirectional serial interface | Bidirectional serial interface | Bidirectional serial interface | Bidirectional serial interface | Bidirectional serial interface |
主な差別化要因
- High-resolution sigma-delta conversion with integrated gain (vs AD7712AN)
- Two selectable analog input channels (vs AD7731BNZ)
- Direct low-level differential transducer measurement (vs AD7793BRUZ)
設計ノート
Route the differential input and reference connections as short, matched traces away from digital-interface switching current. Use the Analog Devices AD7712 datasheet pin-description and layout guidance when assigning the 24-pin PDIP footprint. Keep the analog and digital return paths controlled, avoid routing serial signals beneath sensitive input nodes, and provide local bypass capacitance at the supply pins to minimize supply-to-input coupling.
Select the digital filter bandwidth and output-data-rate mode according to the physical bandwidth of the sensor. A narrow filter improves rejection of noise but increases the time required to settle after an input or gain change. For bridge and resistive sensors, verify excitation settling before sampling and leave sufficient settling time after each gain or channel change. This prevents transient settling from being interpreted as a valid measurement.
Do not configure the AD7712ANZ solely by its 24-bit resolution. Check the input common-mode range, maximum differential input span, programmed gain, reference voltage, and supply limits against the transducer output. The converter accepts direct low-level signals and higher-level signals, so incorrect gain or span selection can cause saturation, clipping, or inaccurate system calibration even though the serial interface continues operating normally.
Treat analog and digital supplies as separate design domains even when they share a source. Place bypass capacitors close to the supply pins, maintain the manufacturer-recommended voltage tolerance at each IC pin, and prevent digital-interface return current from flowing through the analog reference or input ground path. A stable reference is essential because supply and reference errors can appear as gain or offset errors in the converted result.
コンプライアンス情報
The industrial temperature grade is documented, but no RoHS, REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification declaration was identified in the cited product information.