AD7714AR-5 - 24-Bit Sigma-Delta ADC | Analog Devices
部品番号: AD7714AR-5 ✓ 生産中AD7714AR-5 概要
A sigma-delta ADC is a voltage-regulating measurement category of data-converter IC that uses oversampling, noise shaping, and digital filtering to provide high resolution for slow-changing signals. The AD7714 belongs to the analog-to-digital converter, signal-conditioning ADC, and data-converter IC hierarchy, making it suitable for industrial measurement, sensor instrumentation, and smart microcontroller or DSP-based systems. Its low 500 uA power consumption is especially useful in low-power measurement designs.
The AD7714AR-5 uses sigma-delta conversion to achieve up to 24-bit resolution for low-frequency signals. The integrated signal-conditioning front end reduces the need for separate instrumentation amplifiers in many transducer measurement circuits. Its selectable analog input arrangement supports flexible channel allocation, while the differential reference input helps establish the conversion scale for ratiometric and precision measurements.
The AD7714 is intended for applications requiring high-resolution conversion rather than high-speed sampling. It can process signals from sensors and transducers in industrial process-control equipment, test and measurement systems, medical instrumentation, and microcontroller-based data-acquisition modules. The device is also suitable for weighing systems and other applications where the measured variable changes relatively slowly.
For PCB implementation, follow the manufacturer pin description and recommended application-circuit layout when assigning analog inputs, reference connections, supplies, and serial interface signals. Pay particular attention to reference and analog-input noise, grounding, and the relationship between filtering, output data rate, and signal bandwidth. The 24-SOIC package is surface mount and can be used in compact measurement equipment.
This product page combines the AD7714AR-5 device identity, verified product specifications, package information, practical application guidance, and candidate replacement analysis. The alternatives listed are limited to parts identified in the manufacturer and cross-reference material; engineers should confirm pin-level compatibility, reference requirements, channel configuration, timing, and qualification before releasing a substitute into production.
ドロップイン代替品: AD7714AR-5 — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: AD7714AR-5 (同一形状・フットプリント) — 相違点: Reference Input, Package, Part Number, Supply Voltage, Resolution.
AD7714ARZ-5
✅ ドロップイン📋 参考代替品(カタログ未掲載)
AD7712AR-REEL7
✅ ドロップイン価格はお問い合わせください
データシートを見る →AD7711AAR
✅ ドロップイン価格はお問い合わせください
データシートを見る →AD7711AR-REEL7
✅ ドロップイン📋 参考代替品(カタログ未掲載)
AD7714AR-5REEL
✅ ドロップイン📋 参考代替品(カタログ未掲載)
AD7714AR-5 最大定格&電気的特性
| Converter Type | 24-bit sigma-delta ADC |
| 分解能 | 24 bit |
| Analog Input Channels | 3 differential or 5 pseudo-differential inputs |
| Reference Input | Differential reference input |
| 電源電圧 | 3 V or 5 V single supply |
| Power Consumption | 500 uA |
| Process Technology | CMOS |
| Conversion Method | Sigma-delta |
| Output Format | Serial digital word |
| Input Signal Level | Low-level transducer signals |
| Application Class | Low-frequency measurement |
| パッケージ | 24-lead SOIC |
| 実装タイプ | Surface mount |
AD7714AR-5 24-lead soic ピン配置ガイド
AD7714AR-5 (24-lead soic パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: AD7714AR-5.
詳細は データシート をご参照ください。
主な用途
AD7714AR-5 の用途: 6 件s: Industrial Process Measurement, Load Cell and Weighing Systems, Medical and Diagnostic Instrumentation, Portable Environmental Sensors, Data Acquisition and Test Equipment, Smart Microcontroller Sensor Hubs.
Industrial Process Measurement
The AD7714AR-5 is appropriate for industrial process-control modules that monitor slowly changing signals from pressure, temperature, level, or flow transducers. Its 24-bit sigma-delta conversion provides high numerical resolution for low-level sensor outputs, while three differential inputs can be configured as five pseudo-differential channels. The 500 uA CMOS power specification helps limit consumption in distributed monitoring nodes, and the single 3 V or 5 V supply simplifies interface design. Use the manufacturer application circuit to establish filtering, reference routing, and grounding around the analog inputs.
おすすめ
Load Cell and Weighing Systems
The AD7714AR-5 can serve as the central converter in a load-cell weighing circuit because it accepts low-level differential signals and provides a 24-bit digital result for downstream processing. The differential analog inputs help reject common-mode noise when the transducer wiring is balanced and the PCB is laid out carefully. A 3 V or 5 V system architecture is convenient for compact bench scales and industrial indicators. The design must account for excitation noise, reference stability, digital-filter settling time, and the conversion-rate-versus-resolution tradeoff specified by the manufacturer.
おすすめ
Medical and Diagnostic Instrumentation
The AD7714AR-5 fits low-frequency medical instrumentation where a sensor produces a small differential voltage and the controller requires a high-resolution measurement word. Its integrated analog front end can reduce the external conditioning chain, while the 500 uA CMOS operating current supports portable and battery-oriented designs. Differential input selection and a differential reference help preserve measurement integrity in systems with long sensor cables. For patient-connected equipment, complete electrical-safety, isolation, leakage-current, and application-specific qualification work must be performed independently of the ADC datasheet.
おすすめ
Portable Environmental Sensors
The AD7714AR-5 is useful in portable temperature, humidity, gas, and environmental sensing nodes where the sensor signal changes slowly and battery consumption matters. The 24-bit resolution can preserve small changes in the transducer output, while the 500 uA CMOS specification supports low-power operation. Three differential inputs, or five pseudo-differential channels when appropriate, allow several sensor inputs to share a conversion device. The system designer should select the digital filter and output rate for the required response time, and maintain clean reference and analog-input routing to avoid degrading the available resolution.
おすすめ
Data Acquisition and Test Equipment
The AD7714AR-5 is appropriate for laboratory and field data-acquisition equipment that measures slow, low-level analog channels rather than high-frequency waveforms. Its serial digital output integrates with microcontrollers or DSPs, and its configurable differential or pseudo-differential input organization supports multiplexed measurement boards. The device is particularly useful when 24-bit resolution matters more than sampling speed. A robust implementation should include a stable reference, protection appropriate to the measured signal, calibration records, and firmware that accounts for settling time after digital-filter changes.
おすすめ
Smart Microcontroller Sensor Hubs
The AD7714AR-5 can serve as a precision sensor hub in a microcontroller-based system that gathers slow-changing measurements from analog transducers. The MCU can configure the ADC, read the serial result, and perform calibration or threshold decisions without requiring a separate high-speed converter. A single 3 V or 5 V supply aligns with many embedded platforms, and the 500 uA CMOS specification helps conserve power. Digital-interface timing, reset behavior, and settling after filter or gain changes should be implemented according to the manufacturer timing characteristics.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: AD7714AR-5 — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | AD7714ARZ-5 | AD7712AR-REEL7 | AD7711AAR |
|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 24-lead SOIC | 24-lead SOIC | 24-lead SOIC | 24-lead SOIC |
| Converter Type | Sigma-delta ADC | Sigma-delta ADC | Sigma-delta ADC | Sigma-delta ADC |
| Application Focus | Low-frequency measurement | Low-frequency measurement | Low-frequency measurement | Low-frequency measurement |
主な差別化要因
- Broader documented input configuration (vs AD7714ARZ-5)
- Single 3 V or 5 V operating flexibility (vs AD7714ARZ-5)
- Low-power CMOS signal conditioning (vs AD7711AAR)
- Multi-channel transducer measurement (vs AD7712AR-REEL7)
設計ノート
Use the manufacturer recommended layout as the starting point for analog inputs, differential reference connections, supply bypass capacitors, and the serial interface. Keep analog and digital return currents separated where possible, place input and reference components close to the device, and avoid routing sensitive analog nets beneath digital clock or serial-data paths. Differential routing should use closely spaced, symmetrical traces where the board geometry permits.
Treat the reference network as part of the measurement accuracy budget. Use a low-noise reference with adequate decoupling, keep the reference route short, and verify that the selected reference remains within the input and output common-mode limits of the AD7714AR-5. Any external reference buffer or filtering components should preserve startup settling and should be checked against the required conversion timing.
Do not select the conversion rate and digital filter independently of the signal bandwidth. A faster output rate generally shortens the filter settling time but reduces the usable in-band resolution, while a slower rate improves rejection of out-of-band noise. Configure channel changes and gain changes so that the controller waits for valid, settled data before using the result.
Power the device from a clean single 3 V or 5 V rail and place the manufacturer-recommended bypass capacitance close to the supply pins. Verify supply ripple, startup sequencing, and logic-level compatibility with the controlling microcontroller or DSP. The 500 uA figure describes the ADC device specification, not total board consumption, so include interface, reference, regulator, and sensor loads in the final power budget.
A replacement part must be checked at pin-function level rather than only by package name. Confirm analog-channel mapping, pseudo-differential configuration, reference polarity, supply limits, conversion timing, serial data format, and calibration behavior. The AD7714AR-5REEL has the same electrical ordering code but differs in reel-packaging format, while AD7711 and AD7712 candidates may change the measurement architecture.
コンプライアンス情報
The reviewed product and distributor snippets do not provide a complete exact-part compliance statement for RoHS, REACH, AEC-Q100, lead-free status, halogen-free status, or conflict minerals. Confirm these attributes using Analog Devices' current compliance documentation for the exact orderable MPN.