AD7716BS - 22-Bit Quad-Channel Sigma-Delta ADC | Analog Devices
部品番号: AD7716BS ✓ 生産中AD7716BS 概要
A sigma-delta ADC is a signal-processing IC category that converts an analog input by using a modulator and digital filtering to shape quantization noise. The AD7716 belongs to the broader ADC and data-converter hierarchy, where it occupies the precision low-bandwidth position rather than the high-speed sampling or waveform-capture market. It is intended for sensors and instrumentation signals that require high resolution, programmable filtering, and relatively low update rates.
The AD7716BS provides 22-bit resolution, with no missed codes guaranteed to 21 bits at a cutoff frequency of 146 Hz. Its usable dynamic range is 111 dB with a 36.5 Hz input bandwidth, and integral nonlinearity is specified at 0.003%. The on-chip low-pass filter has a programmable cutoff beginning at 36.5 Hz, allowing the bandwidth and output-data rate to be balanced for each measurement channel. The interface uses five serial lines and supports two's-complement coding for straightforward connection to DSPs and microcomputers.
Its four-channel architecture makes the converter suitable for multichannel measurement systems in which synchronized or sequential analog-front-end outputs must be digitized. The programmable digital filter is especially useful for suppressing high-frequency noise after the sensor signal has been conditioned, while the 22-bit resolution preserves fine amplitude detail in slow-changing process, laboratory, and industrial measurements. The 584 Hz maximum bandwidth provides additional design flexibility when faster settling is more important than maximum in-band noise rejection.
Typical uses include pressure and temperature monitoring, weighing systems, process-control instrumentation, laboratory measurement equipment, and industrial data-acquisition modules. The AD7716BS is particularly appropriate when several low-frequency analog inputs share a precision converter and the host processor can communicate through a serial interface. For installations requiring different gain ranges, the analog front end should present compatible bipolar or unipolar signals to the converter inputs.
Design the surrounding circuit around the selected digital-filter cutoff and conversion rate. Allow adequate settling time for the filter, apply suitable input protection and reference conditioning, and keep sensitive analog traces short and separated from digital outputs. Because a low-pass filter improves rejection of out-of-band noise, selecting the narrowest acceptable bandwidth can improve usable resolution and reduce the required software filtering burden.
ドロップイン代替品: AD7716BS — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
AD7716BSZ
✅ ドロップイン📋 参考代替品(カタログ未掲載)
AD7716BS 最大定格&電気的特性
| 分解能 | 22 bits |
| Number of Analog Input Channels | 4 channels |
| Maximum Input Bandwidth | 584 Hz |
| Maximum Conversion Rate | 570 ksps |
| Usable Dynamic Range | 111 dB at 36.5 Hz input bandwidth |
| Guaranteed No-Missed-Code Resolution | 21 bits at 146 Hz cutoff frequency |
| Differential Linearity | ±1 LSB or less |
| Integral Nonlinearity | 0.003% |
| Digital Filter Cutoff Frequency | Programmable from 36.5 Hz to 584 Hz |
| Digital Filter Response | Linear phase |
| Maximum External Clock Frequency | 8 MHz |
| Maximum Data Update Rate | 2232 Hz at maximum filter cutoff |
| Serial Interface | 5-wire serial interface |
| Data Format | Two's complement |
| パッケージ | 44-terminal square QFP, 10 mm × 10 mm |
| Temperature Grade | Industrial grade |
AD7716BS 44-terminal square qfp, 10 mm × 10 mm ピン配置ガイド
AD7716BS (44-terminal square qfp, 10 mm × 10 mm パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: AD7716BS.
詳細は データシート をご参照ください。
主な用途
AD7716BS の用途: 6 件s: Industrial Pressure Monitoring, RTD Temperature Measurement, Laboratory Weighing Systems, Process-Control Instrumentation, Portable Environmental Sensors, Precision Data-Acquisition Modules.
Industrial Pressure Monitoring
The AD7716BS fits four-channel pressure-monitoring systems because it combines 22-bit conversion resolution with programmable filter bandwidths from 36.5 Hz to 584 Hz. Place the converter behind a low-noise bridge or instrumentation amplifier, and select a cutoff that rejects pump, relay, and motor noise without delaying pressure updates excessively. Its 111 dB usable dynamic range at 36.5 Hz provides additional signal headroom for detecting small pressure changes. Because the four channels share one precision conversion block, a compact multi-point system can reduce component count, though the host must perform channel sequencing and convert each result using the appropriate calibration coefficients.
おすすめ
RTD Temperature Measurement
The AD7716BS is appropriate for multichannel RTD or thermocouple instrumentation after a suitable low-noise amplifier provides a compatible analog input voltage. The 22-bit resolution can preserve fine temperature increments when the selected filter bandwidth is matched to the thermal response. Filtering at 36.5 Hz offers a strong noise-rejection option for slow temperature changes, while settings approaching 584 Hz shorten the acquisition cycle for faster-changing measurements. The five-wire serial interface connects conveniently to a microcontroller or DSP, allowing the host to apply resistance lookup, cold-junction compensation, or linearization without burdening the analog front end.
おすすめ
Laboratory Weighing Systems
The AD7716BS supports laboratory weighing and force-measurement designs that prioritize resolution over high sample rate. Its 22-bit resolution, ±1 LSB or less differential linearity, and programmable digital filter can capture small changes from load-cell amplifiers while rejecting vibration-related out-of-band noise. A narrow filter setting improves usable noise performance, but it also increases settling time, so the mechanical measurement bandwidth and software averaging strategy should be considered together. The converter's four channels can support one load cell plus auxiliary temperature, reference, or status measurements when those signals fit the same input and conversion configuration.
おすすめ
Process-Control Instrumentation
AD7716BS is well suited to slow process variables such as level, concentration, pH, and flow when the transmitter outputs an analog voltage compatible with its input range. The programmable low-pass filter can suppress switching noise from pumps and variable-speed drives, while bandwidth settings up to 584 Hz provide flexibility for faster loop updates. Four inputs reduce the number of separate converters in a multi-variable controller. Designers should confirm the analog input range, reference accuracy, settling behavior, and isolation requirements at the transmitter interface, since those parameters determine whether the converter can be connected directly or needs additional conditioning.
おすすめ
Portable Environmental Sensors
The AD7716BS can support compact environmental-monitoring instruments that combine several slow-moving sensor channels with a low-power digital filtering stage. Four inputs allow temperature, humidity, gas, and light signals to be measured when suitable analog front ends provide compatible voltage ranges. The converter's serial interface reduces parallel wiring, and its digital filter can suppress noise without demanding extensive host-side processing. For a portable design, power consumption and startup behavior must be evaluated with the selected supply architecture and filter settings, since the datasheet's primary performance positioning is precision rather than minimum energy per conversion.
おすすめ
Precision Data-Acquisition Modules
AD7716BS is appropriate for modular laboratory and field data-acquisition units requiring several high-resolution channels. Its 584 Hz maximum bandwidth supports measurements beyond the 36.5 Hz minimum filter setting, while the 22-bit conversion resolution preserves fine detail in slow analog waveforms. The five-wire serial interface connects cleanly to embedded processors, and the on-chip digital filter reduces high-frequency content before transfer. A successful design must account for the selected filter's settling time, reference stability, analog-front-end noise, and ground isolation. The same filtering benefits apply to vibration envelopes and other slowly varying diagnostics derived from sensor signals.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: AD7716BS — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | AD7716BSZ |
|---|---|---|
| Package | 44-terminal square QFP, 10 mm × 10 mm | 44-terminal square QFP, 10 mm × 10 mm |
| Brand | Analog Devices | Analog Devices |
| Resolution | 22 bits | 22 bits |
| Number of Input Channels | 4 channels | 4 channels |
| Maximum Input Bandwidth | 584 Hz | 584 Hz |
| Maximum Conversion Rate | 570 ksps | 570 ksps |
| Programmable Filter Cutoff | 36.5 Hz to 584 Hz | 36.5 Hz to 584 Hz |
| Usable Dynamic Range | 111 dB at 36.5 Hz input bandwidth | 111 dB at 36.5 Hz input bandwidth |
| Differential Linearity | ±1 LSB or less | ±1 LSB or less |
| Serial Interface | 5-wire serial interface with two's-complement data | 5-wire serial interface with two's-complement data |
主な差別化要因
- Four-channel precision conversion in one device (vs AD7716BSZ)
- Wide programmable filter range (vs AD7716BSZ)
- Designed for precision, low-bandwidth acquisition (vs AD7716BSZ)
設計ノート
Treat the reference and analog inputs as high-impedance precision signals. Place the reference bypass capacitor and input-network components close to the device, use a low-noise reference, and route analog traces away from serial clock and data lines. If the source impedance is high, verify that settling occurs within the acquisition interval selected through the digital-filter and conversion-rate settings. Reference and input filtering should be designed for the desired noise bandwidth rather than copied indiscriminately from a high-speed application.
Follow the supply sequencing and decoupling recommendations in the manufacturer datasheet, including the required value and placement of local bypass capacitors. Check supply-voltage tolerance across temperature and confirm that the analog reference remains within its specified range during startup. Because the converter is intended for precision measurement rather than minimum-power operation, do not estimate current consumption without the actual clock, filter, and channel-conversion schedule used by the finished instrument.
Use the exact 44-terminal square-QFP land pattern and verify pin 1 orientation against the Analog Devices package drawing. Provide adequate solderable land length and consistent paste printing for the fine-pitch gull-wing leads. Keep the exposed routing and copper beneath the device electrically compatible with the package's thermal and electrical requirements. A generic 44-pin QFP footprint should not be used without checking body dimensions, lead span, pitch, and lead geometry.
Do not select the fastest available filter setting by default. The 584 Hz maximum bandwidth reduces settling time but admits more out-of-band noise, while the 36.5 Hz setting improves usable dynamic range at the cost of response time. Configure the digital filter for the physical bandwidth of the measured signal, allow sufficient settling before interpreting each result, and avoid double filtering that can introduce unexpected delay or distort transient behavior.
コンプライアンス情報
The AD7716BS family is associated with an industrial-grade ordering option. Exact environmental and compliance declarations for the selected package and ordering code should be confirmed with Analog Devices.