AD7820CQ - 8-Bit 1.36 us ADC | Analog Devices
部品番号: AD7820CQ ✗ 生産終了AD7820CQ 概要
An ADC converts a continuously varying analog voltage into a numeric value for processing by a microcontroller, computer, or control system. The AD7820 belongs to the converter hierarchy of analog-to-digital converters, data-converter ICs, and mixed-signal semiconductors. Its 8-bit resolution represents an analog input with 256 possible digital codes, making it suitable for monitoring, control, instrumentation, and measurement tasks where a compact digital interface is more important than high resolution.
The AD7820 uses a half-flash architecture containing 31 comparators, a most-significant 4-bit ADC, and a least-significant 4-bit ADC. This arrangement supports microprocessor-compatible operation while providing a conversion time of 1.36 µs. A single +5 V supply simplifies system power design, and the 0 V to +5 V analog input range allows the converter to operate directly across a common unipolar signal range.
Because the converter resolves 8 bits, its theoretical ideal quantization interval is approximately 19.53 mV across the full 5 V range. Actual circuit performance also depends on reference accuracy, input-source impedance, acquisition time, converter noise, grounding, and PCB layout. Designers should treat the nominal input range as the converter function and verify gain, offset, monotonicity, and timing characteristics in the completed analog system rather than assuming ideal converter behavior.
Typical uses include digital voltmeters, process-control instrumentation, industrial sensor interfaces, laboratory measurement equipment, and embedded control systems. The device can follow an analog front-end that converts a sensor or control variable into a voltage between ground and the positive supply. It is also appropriate where a microprocessor must acquire a moderate-resolution measurement at a substantially faster rate than conventional successive-approximation converters.
For reliable implementation, connect the converter to a clean analog supply and use short, well-controlled analog input traces. Place input and reference decoupling capacitors close to their associated pins, maintain a low-impedance analog return path, and isolate switching nodes and digital clocks from the input node. Confirm acquisition timing against the source impedance, and check the complete reference and input network for settling before the converter starts a conversion.
This product page organizes the AD7820CQ conversion architecture, package information, sourcing options, design considerations, and verified alternatives. It also identifies where application-specific details must be established from the manufacturer datasheet, helping engineers move from component selection to a defensible circuit-design decision.
ドロップイン代替品: AD7820CQ — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: AD7820CQ (同一形状・フットプリント) — 相違点: Conversion Time, Package, Supply Voltage.
この製品に利用可能なドロップイン代替品はありません。
代替品をリクエストAD7820CQ 最大定格&電気的特性
| Converter Type | Half-flash successive-approximation ADC |
| 分解能 | 8 bit |
| Number of Input Channels | 1 channel |
| Conversion Time | 1.36 µs |
| Analog Input Range | 0 V to +5 V |
| 電源電圧 | Single +5 V |
| Architecture | 31 comparators with MSB and LSB 4-bit ADC sections |
| Microprocessor Interface | Microprocessor-compatible |
| パッケージ | 20-lead ceramic DIP |
| 実装タイプ | Through-hole |
AD7820CQ 20-lead ceramic dip ピン配置ガイド
AD7820CQ (20-lead ceramic dip パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: AD7820CQ.
詳細は データシート をご参照ください。
主な用途
AD7820CQ の用途: 6 件s: Digital Panel Meter, Industrial Sensor Interface, Process Control Loop, Laboratory Voltage Measurement, Embedded Control System, Automatic Test Equipment.
Digital Panel Meter
The AD7820CQ suits a basic digital panel meter that displays a coarse measurement from a 0 V to +5 V sensor signal. Its 8-bit output provides 256 digital levels across the full input range, while the 1.36 µs conversion time allows rapid acquisition of a changing input. Place the converter behind a scaled and buffered sensor-conditioning stage, and use a stable reference and local supply bypassing to limit measurement error.
おすすめ
Industrial Sensor Interface
The AD7820CQ can convert a conditioned industrial sensor output when 8-bit resolution is sufficient. Its single +5 V supply and 0 V to +5 V input range align with common 0–5 V process signals, and the 1.36 µs conversion time supports responsive monitoring. Protect the analog path from switching noise, verify acquisition settling against the transducer or transmitter output impedance, and isolate ground currents from the converter reference.
おすすめ
Process Control Loop
AD7820CQ can provide a fast measurement in a basic process-control loop when 8-bit quantization meets the actuator-resolution requirement. The 1.36 µs conversion time allows frequent updates, and the unipolar 0 V to +5 V input simplifies interfacing with standard control signals. The loop designer must account for sensor lag, filter delay, acquisition time, and output-code step size to avoid instability or oscillation.
おすすめ
Laboratory Voltage Measurement
The AD7820CQ is applicable to simple laboratory voltage measurement when 8-bit resolution and 1.36 µs conversion speed are sufficient. Its analog input spans 0 V to +5 V, allowing a conditioned probe signal to be digitized without a bipolar converter. For repeatable readings, use a low-noise reference, short shielded input routing, a stable source impedance, and averaging appropriate for the required measurement uncertainty.
おすすめ
Embedded Control System
The AD7820CQ can serve as the analog acquisition element in an embedded controller that monitors a 0–5 V control or status signal. Its microprocessor-compatible architecture supports rapid transfer of an 8-bit result into digital control logic, while its compact, straightforward interface reduces firmware and analog-conversion complexity. Firmware should define scaling, filtering, fault detection, and conversion sequencing, and the hardware should preserve a clean analog return path.
おすすめ
Automatic Test Equipment
AD7820CQ can act as a fast coarse measurement channel in automatic test equipment that evaluates a 0 V to +5 V output level. Its 1.36 µs conversion time supports high sample throughput, and the 8-bit result is useful for pass/fail categorization or coarse calibration. For accurate production limits, characterize offset and gain error, add external reference conditioning if required, and avoid using the converter for a threshold tighter than its calibrated uncertainty.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: AD7820CQ — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 |
|---|---|
| Package | 20-lead ceramic DIP |
| Brand | Analog Devices |
| Resolution | 8 bit |
| Conversion Time | 1.36 µs |
| Analog Input Range | 0 V to +5 V |
| Supply Voltage | Single +5 V |
| Input Channels | 1 channel |
| Conversion Architecture | Half-flash with 31 comparators and two 4-bit ADC sections |
| Digital Interface | Microprocessor-compatible |
| Mounting Type | Through-hole |
主な差別化要因
- Fast half-flash conversion (vs No verified drop-in alternative)
- Simple unipolar signal interface (vs No verified drop-in alternative)
- Distinct ceramic-DIP implementation (vs No verified drop-in alternative)
設計ノート
Route the analog input and reference paths away from digital clocks and switching-node copper. Place supply and reference decoupling components close to the corresponding AD7820CQ pins, use a continuous ground plane where practical, and minimize input-loop area. Keep the converter and sensitive analog components physically separated from relays, high-current switches, and digital output-return paths.
Do not assume that an 8-bit converter can resolve a 5 V signal more accurately than its noise, offset, gain error, and reference error permit. The ideal code interval is approximately 19.53 mV, so a measurement requiring much finer resolution should use a higher-resolution ADC. Calibrate offset and gain if the application depends on absolute accuracy, and specify the tolerance of the external reference network.
Verify that the analog source can charge the sampling network and settle within the acquisition interval defined by the manufacturer timing diagram. A long cable, high sensor impedance, or slow amplifier may require a larger sampling capacitor or a lower-impedance buffer. Use the exact control timing from the datasheet and allow additional margin for temperature and supply variation.
コンプライアンス情報
No specific RoHS, REACH, lead-free, halogen-free, or conflict-minerals declaration was identified for the exact AD7820CQ ordering code. AEC-Q100 is not applicable because this is an analog converter rather than an automotive-qualified device.