AD7856KR - 14-Bit 285 kSPS 8-Channel ADC | Analog Devices
部品番号: AD7856KR ✓ 生産中AD7856KR 概要
An ADC converts an analog voltage into a digital numerical value. The AD7856 belongs to the SAR ADC family, within the broader analog-to-digital converter and signal-processing IC hierarchy. Its eight-channel architecture reduces the number of external analog switches and separate converter circuits required in industrial control, instrumentation, data acquisition, and embedded measurement systems.
The device operates from one 5 V supply and provides 285 kSPS throughput. Normal-operation power dissipation is typically 60 mW, while power-down operation reduces consumption to 5.1 mW at a 10 kSPS throughput rate. Power-down options help minimize energy use when continuous conversion is unnecessary. The 24-lead SOIC package is available in a compact surface-mount form for equipment requiring multiple channels and moderate sampling speed.
The AD7856 powers up with defined default conditions and can initially operate as a read-only ADC. Its self-calibration and system-calibration functions support consistent measurements across operating time and temperature. These features are particularly useful when the converter must preserve accuracy in industrial systems exposed to supply variation, temperature changes, and repetitive analog input measurements.
Typical uses include process-control instrumentation, sensor-interface systems, industrial data acquisition, medical monitoring equipment, and embedded control platforms. The eight-channel input arrangement is useful when multiple sensors or potentiometer-derived voltages must be digitized by one converter. For battery-operated or intermittently sampled systems, the power-down modes can reduce average energy consumption when conversion is enabled only on demand.
PCB design should keep analog inputs and reference connections short, place input and reference bypass capacitors close to their associated pins, and route digital interface signals away from sensitive analog traces. Because the AD7856 is a SAR ADC, sampling and conversion occur in successive stages, so input settling time and acquisition timing should be checked against the required source impedance and conversion cycle.
This page combines manufacturer specifications, package and interface guidance, calibrated operation considerations, and a structured comparison with pin-compatible Analog Devices family options. It is intended to help engineers evaluate the AD7856KR for multichannel measurement systems while accounting for throughput, power consumption, calibration behavior, and board-layout constraints.
ドロップイン代替品: AD7856KR — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: AD7856KR (同一形状・フットプリント) — 相違点: Calibration, Package, Supply Voltage.
AD7856ARZ-REEL7
✅ ドロップイン価格はお問い合わせください
データシートを見る →AD7856BRZ
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
AD7856CRZ
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
AD7856KRZ
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
AD7856ARZ-REEL7
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →AD7856BR
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
AD7856KR 最大定格&電気的特性
| Converter Type | Successive-approximation ADC |
| 分解能 | 14 bit |
| Throughput Rate | 285 kSPS |
| 電源電圧 | 5 V |
| Number of Analog Inputs | 8 single-ended or 4 pseudo-differential |
| Normal Operation Power Dissipation | 60 mW typical |
| Power-Down Power Dissipation | 5.1 mW typical at 10 kSPS throughput |
| Construction | CMOS |
| Calibration | Self-calibration and system calibration |
| Power-Up Default | Read-only ADC operation |
| パッケージ | 24-lead SOIC, 0.3 inch wide |
| 実装タイプ | Surface mount |
| Analog Input Type | Single-ended or pseudo-differential |
| Sampling Rate at Power-Down Example | 10 kSPS |
AD7856KR 24-lead soic, 0.3 inch wide ピン配置ガイド
AD7856KR (24-lead soic, 0.3 inch wide パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: AD7856KR.
詳細は データシート をご参照ください。
主な用途
AD7856KR の用途: 6 件s: Industrial Process Monitoring, Multichannel Data Acquisition, Medical Signal Conditioning, Portable Measurement Instruments, Automatic Test Equipment, Embedded Control and Sensor Hubs.
Industrial Process Monitoring
The AD7856KR fits industrial process-monitoring systems that must scan several analog sensors with one converter. Its eight single-ended inputs reduce the number of separate ADC channels and external switching stages, while the 285 kSPS throughput provides rapid updates across the input bank. The 5 V supply simplifies integration with commonly used industrial control logic. Self-calibration and system-calibration options help the converter maintain measurement consistency over time and temperature. For pressure, temperature, or position sensing, confirm that each source settles within the acquisition interval and that the reference voltage remains within its permitted operating range.
おすすめ
Multichannel Data Acquisition
The AD7856KR is appropriate for compact multichannel data-acquisition systems requiring 14-bit resolution at a moderate sampling rate. Eight single-ended inputs can monitor transducers, potentiometers, or divided voltage sources, and the 285 kSPS maximum throughput supports rapid scans when the source impedances permit short acquisition times. The converter can also operate in pseudo-differential mode when paired analog signals are required. Its self-calibration and system-calibration functions add value in instrumentation where offset and gain stability over time and temperature are important. The 24-lead SOIC package keeps the converter footprint manageable, although careful layout remains essential for analog-noise isolation.
おすすめ
Medical Signal Conditioning
The AD7856KR can support multichannel medical monitoring front ends when the selected analog signals fit its single-ended input range and 285 kSPS conversion capability. Eight channels allow several biosensors or conditioned physiological signals to share one converter, reducing component count in compact equipment. The 14-bit result provides a defined numerical resolution for signal-conditioning stages that perform amplification and filtering before digitization. Calibration options support stable operation as patient-monitoring equipment experiences temperature changes and long duty cycles. Medical designs must also satisfy their own input-protection, isolation, leakage, safety, and qualification requirements, which are outside the basic converter specification.
おすすめ
Portable Measurement Instruments
The AD7856KR suits portable measurement instruments that need several analog inputs but do not require continuous maximum-rate conversion. Its power-down mode reduces typical dissipation to 5.1 mW at a 10 kSPS throughput rate, compared with 60 mW during normal operation, helping designers control energy consumption in intermittently active equipment. The single 5 V supply also simplifies battery-regulated power architecture when paired with suitable regulation. The converter is used in a duty-cycled sequence: wake or enable conversion, acquire the required channels, process the data, and return to a low-power state. Actual battery life also depends on regulator losses, interface activity, and the selected sampling rate.
おすすめ
Automatic Test Equipment
The AD7856KR can serve in automatic test equipment that measures multiple low- or moderate-bandwidth analog nodes and requires deterministic sampling. Its 285 kSPS throughput allows measurements to be grouped into scans rather than performed with one converter per channel, and the eight-input configuration simplifies rack and fixture wiring. Calibration functions are useful in systems that repeat measurements over long production campaigns and changing temperatures. The digital control interface supports coordinated acquisition and data transfer to test electronics. Designers should evaluate input bandwidth, settling after channel switching, clock jitter where applicable, and grounding because fixture-level errors may dominate the converter's 14-bit resolution.
おすすめ
Embedded Control and Sensor Hubs
The AD7856KR works in embedded control systems that aggregate several analog sensor inputs before processing them digitally. Eight single-ended channels can represent pressure, position, light, or resistive sensor outputs, while 285 kSPS throughput is suitable for moderate-rate supervisory measurements rather than high-bandwidth waveform capture. The 14-bit converter provides more numerical range than an 8-bit or 12-bit ADC and can improve control-loop resolution when front-end noise is controlled. The 5 V operating supply and 24-lead SOIC package support conventional industrial controller boards. Firmware should account for startup defaults, calibration sequencing, power-down intervals, and the acquisition timing associated with multiplexed input changes.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: AD7856KR — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | AD7856ARZ | AD7856BRZ | AD7856CRZ | AD7856KRZ | AD7856AR | AD7856BR |
|---|---|---|---|---|---|---|---|
| Package | 24-lead SOIC | 24-lead SOIC | 24-lead SOIC | 24-lead SOIC | 24-lead SOIC | 24-lead SOIC | 24-lead SOIC |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Resolution | 14 bit | 14 bit | 14 bit | 14 bit | 14 bit | 14 bit | 14 bit |
| Throughput Rate | 285 kSPS | 285 kSPS | 285 kSPS | 285 kSPS | 285 kSPS | 285 kSPS | 285 kSPS |
| Supply Voltage | 5 V single supply | 5 V single supply | 5 V single supply | 5 V single supply | 5 V single supply | 5 V single supply | 5 V single supply |
| Input Configuration | 8 single-ended or 4 pseudo-differential | 8 single-ended or 4 pseudo-differential | 8 single-ended or 4 pseudo-differential | 8 single-ended or 4 pseudo-differential | 8 single-ended or 4 pseudo-differential | 8 single-ended or 4 pseudo-differential | 8 single-ended or 4 pseudo-differential |
| Normal Operation Power Dissipation | 60 mW typical | 60 mW typical | 60 mW typical | 60 mW typical | 60 mW typical | 60 mW typical | 60 mW typical |
| Power-Down Power Dissipation | 5.1 mW typical at 10 kSPS | 5.1 mW typical at 10 kSPS | 5.1 mW typical at 10 kSPS | 5.1 mW typical at 10 kSPS | 5.1 mW typical at 10 kSPS | 5.1 mW typical at 10 kSPS | 5.1 mW typical at 10 kSPS |
| Calibration Features | Self-calibration and system calibration | Self-calibration and system calibration | Self-calibration and system calibration | Self-calibration and system calibration | Self-calibration and system calibration | Self-calibration and system calibration | Self-calibration and system calibration |
| Ordering and Temperature Grade | K ordering suffix | A and Z suffix ordering | B and Z suffix ordering | C and Z suffix ordering | K and Z suffix ordering | A suffix ordering | B suffix ordering |
主な差別化要因
- Eight-channel conversion without changing the core sampling rate (vs AD7856ARZ)
- Single-supply operation reduces power-tree complexity (vs AD7856BRZ)
- Integrated calibration for long-term measurement consistency (vs AD7856CRZ)
- Eight-channel SOIC integration preserves board area (vs AD7856KRZ)
設計ノート
Route the eight analog inputs as short, quiet traces and place their input-network components close to the corresponding pins. Keep the digital clock, data, and control traces away from the analog input and reference paths. A solid ground plane, careful partitioning between analog and digital sections, and a quiet reference return path are important because 14-bit resolution leaves little margin for conversion error caused by input coupling or ground noise.
Place the 5 V supply bypass capacitor immediately across the device's supply pins and connect it to the quiet analog ground reference. Follow the manufacturer datasheet for the recommended capacitor values and layout. Avoid routing supply current through the analog-input or reference-return paths. Because normal-operation dissipation is typically 60 mW, the SOIC package can operate near local thermal equilibrium in ordinary ambient conditions, but airflow and copper area still influence junction temperature.
Do not treat the 285 kSPS headline rate as the rate available for every source without checking acquisition time. Multiplexed inputs must settle after switching, and high source impedance can require longer acquisition or a lower sampling rate. Use the manufacturer timing diagrams to establish read/convert boundaries, allow the analog path to settle, and verify the interface timing before selecting a high system clock.
Preserve the integrity of the reference signal because conversion accuracy depends directly on reference stability and noise. Place reference-decoupling components according to the manufacturer recommendations, avoid sharing high-current return paths with the reference, and verify reference settling after power-up. Calibrate using the established system sequence; self-calibration and system-calibration improve consistency but do not correct an unstable or incorrectly connected reference network.
For duty-cycled designs, define the converter's power state in firmware before analog signals are sampled. The AD7856 supports power-down operation, with typical dissipation of 5.1 mW at 10 kSPS, compared with 60 mW during normal operation. Avoid unnecessary wake-ups, but also allow startup and calibration time before the first valid measurement. Account for regulator quiescent current when calculating total portable-system energy use.
コンプライアンス情報
Compliance status requires confirmation from the manufacturer's current product documentation and ordering information.