AD7880BN - 12-Bit 66 kHz SAR ADC | Analog Devices
部品番号: AD7880BN ✓ 生産中AD7880BN 概要
A successive-approximation ADC, or SAR ADC, converts an analog input into a digital code by progressively comparing the sampled voltage with a reference-derived ladder. The AD7880 combines this conversion principle with an on-chip track-and-hold amplifier, multiple-input range circuitry, versatile interface logic, and a power-save feature. This places it within the hierarchy of data-converter ICs, analog-to-digital converters, and signal-chain semiconductors.
Key features include a 12-bit resolution, two analog input channels, 66 kHz throughput, and an on-chip track-and-hold amplifier. The converter uses 25 mW of typical power during normal operation and as little as 2 mW in power-save mode. Signal-to-noise ratio is specified at 70 dB, while the fast data-access time of 57 ns supports efficient connection to digital control circuitry.
The internal resistor network allows the AD7880BN to accept unipolar and bipolar input signals. Its 3 µs track-and-hold period is followed by a 12 µs successive-approximation conversion, allowing a new conversion result to be produced at a maximum throughput of 66 kHz. These characteristics make the device appropriate for moderate-speed industrial measurement, process control, instrumentation, and embedded data-acquisition systems.
Typical uses include digitizing pressure, temperature, position, and analog sensor signals; monitoring industrial process variables; and feeding control loops in factory automation equipment. The two-input architecture also permits sequential measurement of two related signals when converter throughput and channel-switching requirements fit the system timing budget.
For layout, keep analog input and reference routing away from fast digital clock and bus traces, and use the manufacturer datasheet pin-description and layout guidance when assigning tracks. Because the AD7880BN uses a single +5 V supply, supply decoupling and analog grounding remain important for achieving predictable conversion performance and signal-to-noise ratio.
This page combines the manufacturer’s converter specifications with practical application guidance, sourcing information, and a direct comparison against the Pb-free AD7880BNZ option. It is intended to help engineers identify the correct package variant, verify interface timing, and plan a replacement without changing the board footprint.
ドロップイン代替品: AD7880BN — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
AD7880BNZ
✅ ドロップイン📋 参考代替品(カタログ未掲載)
AD7880BN 最大定格&電気的特性
| 分解能 | 12 bit |
| Architecture | Successive-approximation ADC |
| Input Channels | 2 analog inputs |
| Throughput Rate | 66 kHz |
| Conversion Time | 12 µs |
| Track-and-Hold Acquisition Time | 3 µs |
| 電源電圧 | Single +5 V |
| Signal-to-Noise Ratio | 70 dB |
| Power-Save Mode Power | 2 mW typical |
| Normal Operating Power | 25 mW typical |
| Data Access Time | 57 ns |
| Input Signal Capability | Unipolar and bipolar inputs |
| Integrated Conversion Features | 3 µs track-and-hold amplifier and 12-bit successive-approximation ADC |
| Interface Features | Versatile interface logic |
| Power Management | Power-save feature |
| パッケージ | 24-lead plastic DIP |
| 実装タイプ | Through-hole |
AD7880BN 24-lead plastic dip ピン配置ガイド
AD7880BN (24-lead plastic dip パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: AD7880BN.
詳細は データシート をご参照ください。
主な用途
AD7880BN の用途: 6 件s: Industrial Process Monitoring, Temperature and Pressure Acquisition, Factory Automation Control, Test and Measurement Instrumentation, Position and Motion Feedback, Embedded Data Acquisition.
Industrial Process Monitoring
The AD7880BN fits industrial process monitoring because its 66 kHz throughput, 12 µs conversion time, and 70 dB signal-to-noise ratio provide useful performance for pressure, level, and flow signals. Two analog inputs allow the controller to measure two related process variables sequentially. The unipolar and bipolar input capability simplifies conditioning for sensors with different output conventions. Use the 3 µs acquisition window to allow the external input network to settle before each conversion.
おすすめ
Temperature and Pressure Acquisition
The AD7880BN is appropriate for temperature and pressure acquisition systems requiring rapid sequential sampling of two analog channels. Its 12-bit resolution and 66 kHz maximum throughput support responsive measurement of conditioned bridge, RTD, or transducer outputs. The single +5 V operation simplifies system power architecture, while 2 mW power-save operation reduces consumption during measurement gaps. The analog front end should limit bandwidth and provide a stable reference to preserve measurement repeatability.
おすすめ
Factory Automation Control
The AD7880BN can serve as the acquisition stage in factory automation controllers that monitor position, actuator feedback, or analog process nodes. A 12 µs conversion time permits timely control-loop updates, and the 57 ns data-access time supports rapid transfer of the 12-bit result. The two-input arrangement is useful for comparing a sensed value with a reference or feedback channel. Keep digital control signals away from sensitive analog traces to prevent coupling into the measurement channel.
おすすめ
Test and Measurement Instrumentation
The AD7880BN is well suited to compact test and measurement equipment that digitizes two moderate-bandwidth channels without requiring a high-power converter. Its 12-bit resolution, 70 dB SNR, and 66 kHz throughput cover general-purpose voltage measurement, calibration, and signal monitoring functions. The power-save mode helps reduce consumption in portable instruments between readings. Reference-layout and analog-ground practices remain important because reference instability directly affects the converted code.
おすすめ
Position and Motion Feedback
The AD7880BN can digitize position or motion feedback produced by analog sensors where 12-bit resolution and a 66 kHz sample rate meet the control-loop requirement. Two inputs allow the system to monitor a position signal and a complementary feedback signal sequentially. The 3 µs track-and-hold time is suitable for sampling settled outputs from suitable sensor drivers. Signal-conditioning bandwidth should be selected so the sensor output remains stable during acquisition.
おすすめ
Embedded Data Acquisition
The AD7880BN provides a compact acquisition path for embedded systems that need to capture two analog channels at moderate speed. The single +5 V supply, 25 mW normal operating power, and 2 mW power-save power simplify integration with embedded control hardware. Its 57 ns data-access time allows the converter output to be captured efficiently by an external controller or microcontroller interface. Designers should include the manufacturer’s recommended decoupling and provide a clean reference implementation.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: AD7880BN — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | AD7880BNZ |
|---|---|---|
| Package | 24-PDIP | 24-PDIP |
| Brand | Analog Devices | Analog Devices |
| Resolution | 12 bit | 12 bit |
| Architecture | Successive-approximation ADC | LC²MOS successive-approximation ADC |
| Input Channels | 2 analog inputs | 2 analog inputs |
| Throughput Rate | 66 kHz | 66 kHz |
| Conversion Time | 12 µs | 12 µs |
| Supply Voltage | Single +5 V | Single +5 V |
| Signal-to-Noise Ratio | 70 dB | 70 dB |
| Data Access Time | 57 ns | 57 ns |
| Power-Save Mode | 2 mW typical | 2 mW typical |
| Package Material Option | Original AD7880BN designation | Pb-free designation |
主な差別化要因
- Combines two analog inputs with moderate-speed 12-bit conversion (vs AD7880BNZ)
- Single +5 V operation supports simplified analog power architecture (vs AD7880BNZ)
- Low-power acquisition with selectable operating behavior (vs AD7880BNZ)
設計ノート
Route the two analog inputs and reference connection away from output clock, control, and digital interface traces. Keep the analog and digital return paths separated as far as the board geometry permits, and join them at a controlled ground point near the converter. A compact input path reduces susceptibility to capacitive coupling and helps the source settle during the AD7880BN’s 3 µs acquisition interval.
Follow the manufacturer’s +5 V decoupling configuration and place the recommended capacitors immediately beside the supply and ground pins. Pay particular attention to dynamic current flow during each 12 µs conversion rather than evaluating only average converter power. Stable local supply voltage reduces code variation that could otherwise appear as measurement error or reference-dependent gain error.
Do not treat the 66 kHz figure as a guaranteed system sample rate without checking acquisition, conversion, multiplexing, and data-transfer timing. When switching between the two inputs, allow the source impedance and external filter to settle before starting conversion. Also verify unipolar versus bipolar input limits in the electrical-characteristics table before scaling the analog front end.
Power-save mode reduces typical consumption from 25 mW to 2 mW but may interrupt continuous conversion sequencing. Firmware and acquisition control should explicitly account for wake-up and settling behavior before interpreting a new result. If the application needs uninterrupted sampling, keep the converter in normal operating mode and validate latency through the complete measurement chain.
コンプライアンス情報
The AD7880BNZ is explicitly identified as a Pb-free option, but the AD7880BN package lead-free status and broader environmental declarations are not established. AEC-Q100 qualification is not applicable to this industrial converter.