Analog Devices

ICL7106IP - 3.5-Digit LCD A/D Converter | Analog Devices

部品番号: ICL7106IP ✓ 生産中
在庫あり 1〜3営業日以内に発送
40-pin PDIP Package Integrated clock Speed
開始価格 $8.4958 USD / 個
MOQ: 1 |
価格更新日: 2026-10-23
ボリューム価格
数量 単価 小計
1 $8.4958 $8.50
10 $8.4958 $84.96
100 $8.4958 $849.58
500 $8.4958 $4,247.90
1,000 $8.4958 $8,495.80
ℹ️ すべての価格はUSDです

ICL7106IP 概要

The Analog Devices ICL7106IP is a low-power, 3.5-digit successive-approximation A/D converter with integrated seven-segment decoders, LCD display drivers, reference, and clock circuitry in a 40-pin PDIP package. The converter is designed for liquid-crystal displays and uses dual-slope conversion to provide stable measurements in instrument and industrial environments.

An A/D converter is an analog-to-digital converter that transforms a continuously varying voltage or current-derived signal into a numeric representation. The ICL7106 belongs to the display-oriented A/D converter hierarchy, combining measurement conversion, display decoding, display drive, reference voltage, and timing functions in one device. Its integrated LCD backplane drive is intended to reduce the external circuitry required for panel instruments.

Key features of the ICL7106 include 3.5-digit resolution, seven-segment display decoding, LCD display-driver capability, an integrated reference, an integrated clock, true differential input and reference support, and dual-slope conversion. The device family is designed to reject interference signals common in industrial environments, while ratiometric measurement support is useful for ohms and bridge-transducer applications.

The ICL7106 uses dual-slope conversion rather than a high-speed successive-approximation architecture. This approach integrates an input over a fixed measurement interval and compares the resulting charge with a reference-derived ramp. The architecture is well suited to panel meters, digital scales, temperature indicators, and other systems where measurement rate is less important than stable displayed readings and straightforward system integration.

Typical applications include digital panel meters, resistance measurement instruments, bridge-sensor instrumentation, industrial process displays, laboratory meters, weighing systems, and portable measurement equipment. The LCD-focused ICL7106 is generally preferable to LED-display converter variants when the design uses a multiplexed liquid-crystal panel.

Designers should follow the manufacturer datasheet for the exact pin assignments, reference connections, clock requirements, display timing, and input common-mode limits. The 40-pin PDIP footprint also requires sufficient board space, careful decoupling, and routing that separates sensitive analog input and reference paths from display-drive and digital timing nodes.

This page consolidates manufacturer information, distributor availability, pricing context, package identification, and design guidance for engineers evaluating the ICL7106IP in new or replacement LCD instrument designs.

ドロップイン代替品: ICL7106IP — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

クイック比較ツール — 並列比較する代替部品を選択:

ICL7106IP

✅ ドロップイン
Analog Devices
📦 40-pin PDIP
3.5-digit LCD A/D converter · Dual-slope conversion · Multiplexed liquid-crystal display · Integrated seven-segment decoder · Integrated LCD driver with backplane drive · Integrated reference · Integrated clock · True differential input

✓ 在庫あり

$8.4958 / 個

データシートを見る →

ICL7106

✅ ドロップイン
📦 40-pin PDIP
Same ICL7106 family identity, but package suffix and manufacturer-specific order details must be verified; no quantified electrical difference supplied

📋 参考代替品(カタログ未掲載)

ICL7107

✅ ドロップイン
📦 [DATA_NEEDED: package]
LED-display version rather than LCD-display version; display-drive function differs, so replacement suitability is unverified

📋 参考代替品(カタログ未掲載)

ICL7106IP

✅ ドロップイン
Analog Devices
📦 40-pin PDIP
3.5-digit LCD A/D converter · Dual-slope conversion · Multiplexed liquid-crystal display · Integrated seven-segment decoder · Integrated LCD driver with backplane drive · Integrated reference · Integrated clock · True differential input

✓ 在庫あり

$8.4958 / 個

データシートを見る →

ICL7106

✅ ドロップイン
📦 [DATA_NEEDED: package]
Family-level MPN, but exact package suffix and pin compatibility are not established by the supplied data

📋 参考代替品(カタログ未掲載)

ICL7106IP 最大定格&電気的特性

Converter Type 3.5-digit LCD A/D converter
Conversion Architecture Dual-slope conversion
Display Interface Multiplexed liquid-crystal display
Display Decoder Integrated seven-segment decoder
Display Driver Integrated LCD driver with backplane drive
Reference Integrated reference
Clock Integrated clock
Input True differential input
Reference Input True differential reference
分解能 3.5 digits
Power Class Low power
パッケージ 40-pin PDIP
実装タイプ Through-hole

ICL7106IP 40-pin pdip ピン配置ガイド

ICL7106IP (40-pin pdip パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。

ICL7106IP の 40-pin pdip パッケージピン配置図

詳細なピン配置データはありません: ICL7106IP.

詳細は データシート をご参照ください。

主な用途

ICL7106IP の用途: 6 件s: Digital Panel Meter, Resistance Measurement Instrument, Bridge Transducer Readout, Industrial Process Display, Temperature Indicator, Portable Measurement Equipment.

📺

Digital Panel Meter

The ICL7106IP fits digital panel meters that require a stable 3.5-digit numeric readout from an analog sensor signal. Its integrated seven-segment decoder, LCD driver, reference, and clock reduce the number of separate display-support components. The dual-slope conversion method is useful when the meter prioritizes repeatable displayed readings over high sampling rate. In a typical instrument, the sensor signal enters the differential input, while the reference and input filtering networks are arranged according to the manufacturer datasheet. LCD segment and backplane wiring must match the selected panel and verified pinout.

🔧

Resistance Measurement Instrument

ICL7106IP can support resistance-measurement instruments when the measurement is arranged with suitable excitation and ratiometric signal conditioning. The device provides true differential input and reference capability, which is useful when the measured resistance is referenced to a controlled supply or bridge arrangement. The external resistor network, input protection, reference accuracy, and calibration method determine the final resistance range and error. Because the verified data does not specify exact input limits or conversion timing, the circuit must be checked against the current manufacturer datasheet before component selection is finalized.

📟

Bridge Transducer Readout

The ICL7106IP is appropriate for a simple bridge-sensor readout when the transducer output is converted into a differential analog signal and the display range is designed around the bridge excitation. The true differential input and reference functions support ratiometric measurement, allowing the converter to compare the bridge signal against its own reference rather than depending on an unrelated absolute source. Practical designs still require excitation regulation, input filtering, common-mode verification, and calibration. The supplied data identifies bridge and ratiometric measurement use cases but does not provide a specific bridge range or accuracy table.

🏭

Industrial Process Display

ICL7106IP can be used as the measurement and display core in a compact industrial process indicator. Its LCD-focused architecture, integrated clock, and dual-slope conversion suit slower measurements where display readability and periodic-interference rejection are more important than high-speed sampling. The analog front end should include protection appropriate to the process signal, while the reference and input traces should be kept away from display and clock nodes. Final qualification requires verified operating voltage, temperature, noise, and environmental specifications from the manufacturer datasheet.

🌡️

Temperature Indicator

ICL7106IP can present a temperature-derived voltage on a 3.5-digit LCD panel when a suitable sensor front end and linearization network are used. The converter's integrated reference and display functions simplify a dedicated temperature-display instrument, while dual-slope conversion is compatible with slow thermal measurements. The sensor's excitation, transfer curve, cold-junction compensation if applicable, and display scaling determine the achievable range and resolution. Use the manufacturer input and reference guidance to set the analog network and verify calibration across the intended temperature span.

📱

Portable Measurement Equipment

ICL7106IP is suitable for portable, battery-powered measurement equipment where a low-power LCD readout is preferred over an LED display. The integrated clock, reference, decoder, and LCD drivers can reduce board area in a handheld meter, while the 3.5-digit format matches common panel-meter ranges. Battery operation still requires careful review of supply voltage, quiescent consumption, input protection, and display contrast. The verified data does not provide current consumption or operating-voltage values, so those parameters must be taken from the current manufacturer datasheet before final battery sizing.

おすすめ製品の概要

ICL7106 Same A/D converter family 使用用途: Digital Panel Meter, Resistance Measurement Instrument, Bridge Transducer Readout, Industrial Process Display, Temperature Indicator, Portable Measurement Equipment MAX338ETE+ Maxim Integrated 使用用途: Digital Panel Meter NE5532D Texas Instruments 使用用途: Resistance Measurement Instrument LM358D Texas Instruments 使用用途: Bridge Transducer Readout MAX232D Texas Instruments 使用用途: Industrial Process Display LM324D Signal-conditioning amplifier candidate 使用用途: Temperature Indicator MAX3232CD Texas Instruments 使用用途: Portable Measurement Equipment
What is the ICL7106IP?
The ICL7106IP is a low-power, 3.5-digit analog-to-digital converter with integrated seven-segment decoding, LCD display drivers, a reference, and a clock. According to the Analog Devices ICL7106 product information, it is designed for liquid-crystal display interfaces and uses dual-slope conversion. The ICL7106IP is packaged as a 40-pin PDIP.
What display does the ICL7106IP drive?
The ICL7106IP is designed to interface with multiplexed liquid-crystal displays and includes LCD backplane drive. It is not the LED-display version commonly associated with the ICL7107 family. The display, seven-segment connections, backplane arrangement, and timing must therefore be checked against the manufacturer pinout and datasheet.
Where can I download the ICL7106 datasheet PDF?
The official ICL7106 product page is https://www.analog.com/en/products/icl7106.html, where Analog Devices provides product documentation and data-sheet access. A manufacturer-hosted PDF is preferable for design work because third-party copies may reflect older revisions. Confirm the package and ordering code against the 40-pin PDIP ICL7106IP before release.
Where can I find the ICL7106IP pinout?
The ICL7106IP pinout should be obtained from the Analog Devices or Maxim ICL7106 manufacturer datasheet, because display-drive and analog timing assignments are package-specific. The ICL7106IP is identified as a 40-pin PDIP in distributor results. Use the 40-pin PDIP schematic symbol and verify every LCD, reference, input, clock, and supply connection before layout.
What is the conversion technology used by the ICL7106IP?
The ICL7106IP uses dual-slope conversion. Dual-slope converters integrate the input over a defined period and compare the result with a reference-derived ramp. This architecture is suited to stable panel-meter readings and industrial measurement systems where measurement rate is modest and rejection of periodic interference is useful.
Is the ICL7106IP still active?
The Analog Devices product page identifies the ICL7106 as production and describes it as a production 3.5-digit A/D converter family. The exact ICL7106IP lifecycle and inventory status can change, so confirm current availability with the manufacturer or an authorized distributor before committing a production schedule. Current distributor results include ICL7106IP listings.
What is the price of ICL7106IP?
The supplied distributor listing shows ICL7106IP pricing from $8.4958 as of 2026-10-23. Price can vary by quantity, stock, distributor, and whether the component is new or sourced through a marketplace. Use the distributor checkout and manufacturer authorized channels for a current quotation rather than relying on the historical listing price alone.
Is ICL7106IP in stock?
ICL7106IP is shown as in stock by the supplied LCSC result as of the verification date, and DigiKey Marketplace also provides an ordering listing. Stock is distributor-specific and may change rapidly. Treat the listing as a lead indicator, not a guaranteed allocation, and request a confirmed stock quotation for production quantities.
What is the lead time for ICL7106IP?
A specific ICL7106IP lead time is not provided in the verified data, so the exact delivery timing must be confirmed with the selected distributor as of 2026-10-23. The LCSC result advertises an in-stock component from $8.4958, while other listings may represent marketplace or specialty inventory. For scheduled production, obtain a written lead time and traceability information.
Can ICL7106IP measure resistance or bridge sensors?
Yes, the ICL7106IP is suitable for measurement systems using ratiometric techniques, including resistance and bridge-transducer designs. The Analog Devices product information specifically identifies true differential input and reference support as useful for ratiometric measurements. The external excitation, input filtering, reference accuracy, calibration, and display count range still need to be designed for the selected sensor.
Can an ICL7106 be used in an LED-display instrument?
An ICL7106 is specifically optimized for LCD instruments, so it is not automatically the correct choice for an LED display. The related ICL7107 family is identified in the verified product information as the version intended to directly drive instrument-size LED displays. If your existing board uses LED drive connections, verify pin compatibility and timing before considering a replacement.
What are the key specifications of ICL7106IP that engineers should know?
The key ICL7106IP specifications are 3.5-digit resolution, dual-slope conversion, true differential input and reference, integrated seven-segment decoding, integrated reference and clock, multiplexed LCD backplane drive, and a 40-pin PDIP package. The Analog Devices product page also emphasizes low power and interference rejection. Exact voltage, timing, accuracy, and temperature limits must be taken from the current manufacturer datasheet.
What is the best drop-in replacement for ICL7106IP?
No verified same-package drop-in replacement is identified in the supplied cross-reference data. The ICL7106IP is a 40-pin PDIP LCD A/D converter, and changing to an LED-display or different package device can alter pin functions, timing, and external circuitry. Treat any replacement as a redesign until the manufacturer pinout and electrical requirements have been compared explicitly.
Is ICL7106IP suitable for industrial panel meters?
ICL7106IP is suitable for many industrial panel-meter designs because its dual-slope architecture, differential input, differential reference, integrated LCD drive, and integrated clock support instrument-panel measurement. The provided data does not include operating-voltage, temperature, accuracy, or EMC limits, so those specifications must be verified in the manufacturer datasheet before claiming suitability for a particular industrial environment.
How should the ICL7106IP be connected to an LCD?
Connect the ICL7106IP to the multiplexed LCD according to the manufacturer pinout, segment outputs, backplane outputs, reference network, input network, clock network, and supply wiring. Do not infer LCD compatibility from the generic ICL7106 name alone. Check the display's segment count, backplane count, drive levels, and timing against the datasheet before fabrication.

エンジニアリング参考データ: ICL7106IP — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the ICL7106IP when the target instrument requires a 3.5-digit LCD panel display and benefits from an integrated reference, clock, seven-segment decoder, and LCD driver. Its dual-slope architecture is well suited to panel meters, resistance instruments, bridge readouts, and other relatively slow measurement systems. Do not choose the ICL7107 family unless the existing design specifically uses LED displays, because the display interface differs. No verified same-package substitute was established in the supplied data, so treat any replacement as a redesign until the exact pinout, electrical limits, package, display timing, and calibration behavior are checked. For new compact designs, also verify current supply requirements, operating temperature, accuracy, and lifecycle status against the current manufacturer datasheet.

代替品との比較

パラメータ この製品 ICL7106IP ICL7106 ICL7107
Device Function 3.5-digit LCD A/D converter 3.5-digit LCD A/D converter ICL7106 family converter LED-display A/D converter
Brand Analog Devices Analog Devices Renesas Renesas
Display Type Liquid-crystal display LCD LCD LED
Resolution 3.5 digits 3.5 digits 3.5 digits 3.5 digits
Integrated Functions Seven-segment decoder, LCD driver, reference, clock Seven-segment decoder, LCD driver, reference, clock Seven-segment decoder, LCD driver, reference, clock Seven-segment decoder, LED driver, reference, clock

主な差別化要因

  • LCD-specific display architecture (vs ICL7107)
  • Integrated display-support functions (vs Discrete ADC and display-driver implementation)
  • Differential measurement support (vs Single-ended panel-meter architecture)

設計ノート

Route the true differential input, reference, and analog ground paths as a compact signal chain. Keep these nets away from LCD segment outputs, clock nodes, and switching or high-current supply paths. Use the manufacturer reference layout and component placement as the starting point; the verified data does not provide a complete PCB layout, so exact trace widths and grounding topology require the current datasheet and application guidance.

Do not substitute an LED-display ICL7107 for an ICL7106 LCD design without auditing every display connection. The verified family information distinguishes the LCD version from the LED version, and the display drivers have different external load requirements. Also confirm that the 40-pin PDIP footprint, LCD backplane arrangement, reference wiring, and clock components match the selected board before approving a replacement.

Design the supply and decoupling network around the exact manufacturer operating-voltage and current limits, which are not included in the verified data. Place required bypass capacitors close to the supply pins and preserve the datasheet's recommended component values. Because the ICL7106 includes analog conversion, reference, clock, and display-drive functions, inadequate bypassing can affect measurement stability and display behavior.

For ratiometric resistance or bridge measurements, keep the reference and input networks matched and terminate them consistently. Input filtering should reject switching and display-related interference without degrading the intended measurement bandwidth. Validate common-mode limits, source impedance, and conversion timing with the actual sensor and display; these values must be obtained from the manufacturer datasheet rather than estimated.

コンプライアンス情報

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
鉛フリー
Unknown
ハロゲンフリー
Unknown
紛争鉱物
Unknown

Compliance information was not explicitly provided in the verified web data. AEC-Q100 is treated as not applicable because no automotive qualification is stated for ICL7106IP; this should not be interpreted as an automotive certification.

データ検証日: 2026-10-23 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

ICL7106IP ICL7106IP datasheet Analog Devices ICL7106IP ICL7106IP 40-pin PDIP 3.5 digit LCD A/D converter ICL7106IP dual-slope converter ICL7106IP panel meter ICL7106IP resistance measurement ICL7106IP bridge transducer ICL7106IP vs ICL7107 ICL7106IP replacement buy ICL7106IP price ICL7106IP pinout ICL7106IP LCD display ICL7106IP low power instrument

関連部品&用語

Analog Devices ICL7106IP ICL7106 ICL7107 Renesas Maxim Integrated analog-to-digital converter A/D converter 3.5-digit A/D converter dual-slope conversion LCD liquid-crystal display seven-segment decoder LCD display driver integrated reference integrated clock true differential input true differential reference ratiometric measurement bridge transducer resistance measurement digital panel meter 40-pin PDIP through-hole package LCSC DigiKey Marketplace
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
合計: $0.00 USD
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示