ICL7117RCPL - 3.5-Digit Display Driver ADC | Harris Corporation
部品番号: ICL7117RCPL ✓ 生産中ICL7117RCPL 概要
An A-to-D converter is an analog-to-digital converter, commonly abbreviated ADC. It samples a continuously varying voltage and converts it into a numerical value that can be processed, displayed, thresholded, or recorded. Within the broader semiconductor hierarchy, the ICL7117RCPL belongs to the ADC/DAC class of interface and data-conversion integrated circuits. Its integrated display-driver function reduces the number of external connections required in a conventional three-digit panel-meter design.
The key documented attributes include a 3.5-digit display format, one conversion channel, a 40-DIP package measuring 0.600 inches or 15.24 mm across the row of pins, and a commercial operating-temperature range of 0°C to 70°C. The through-hole construction supports conventional insertion into printed circuit boards, panel-meter boards, educational instruments, and industrial measurement equipment. The product is listed as active in the commercial catalog information available for this ordering code.
The ICL7117 architecture combines an analog input stage, conversion logic, and digital display outputs in a single package. This integration is useful when a compact meter must present a numerical measurement without a separate microcontroller performing every display multiplex function. Because it is a dedicated display-driver ADC rather than a general-purpose programmable converter, its fixed three-digit output simplifies panel-meter implementation compared with a microcontroller-based solution.
Typical uses include digital panel meters, laboratory readouts, temperature-measurement instruments, process-monitoring displays, and industrial automation equipment. The three-digit display format is suitable for measurements requiring one or two whole digits plus a fractional digit, while the 40-pin through-hole package is appropriate for larger instruments where long DIP leads simplify hand assembly and serviceability. The device can also be used as the measurement front end in educational laboratory equipment where a stable digital display is required.
PCB design should account for the analog input path, bypass requirements, reference connections, and display outputs defined by the manufacturer pin-description table. Keep sensitive analog traces away from display-output routes, provide the prescribed input and reference filtering, and reserve each of the 40 physical pin positions when creating or reviewing a footprint. The 40-DIP outline and pin numbering must be checked against the manufacturer documentation before assembly.
This product page combines the documented ordering information, package and environmental characteristics, comparison fields, and application guidance into an engineering-focused reference. It also distinguishes the verified display-driver function from broader ADC categories, helping designers evaluate fit, board compatibility, sourcing requirements, and the need for additional conversion or display circuitry before integrating the ICL7117RCPL.
ドロップイン代替品: ICL7117RCPL — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: ICL7117RCPL (同一形状・フットプリント) — 相違点: Temperature Grade.
ICL7117CPM
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
ICL7117CPZ
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
ICL7117CPMZ
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
ICL7117CS
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
ICL7117CPL+
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →ICL7117RCPL 最大定格&電気的特性
| Product Type | 3.5-digit display driver ADC |
| カテゴリ | ADCs/DACs - Special Purpose |
| Number of Channels | 1 channel |
| Display Format | 3.5 digits |
| 動作温度範囲 | 0°C to 70°C |
| Temperature Grade | Commercial |
| 実装スタイル | Through hole |
| パッケージ | 40-DIP |
| Package Width | 0.600 inch / 15.24 mm |
| Number of Terminals | 40 terminals |
| Package Shape | Rectangular |
| ライフサイクル状態 | Active |
| Automotive Qualification | Not applicable |
ICL7117RCPL rectangular ピン配置ガイド
ICL7117RCPL (rectangular パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: ICL7117RCPL.
詳細は データシート をご参照ください。
主な用途
ICL7117RCPL の用途: 6 件s: Digital Panel Meters, Temperature Measurement Instruments, Industrial Process Monitoring, Laboratory Measurement Readouts, Educational Electronics Instruments, Sensor Readout Modules.
Digital Panel Meters
The ICL7117RCPL fits standalone panel meters because it combines a one-channel analog-to-digital conversion function with a fixed 3.5-digit display interface. It can present a scaled measurement without requiring the controlling microcontroller to multiplex three seven-segment digits. The 40-DIP through-hole package is convenient for instrument boards assembled with conventional leaded components. Designers should define the sensor range, establish the reference voltage, and add filtering so the displayed value remains stable under normal operating conditions.
おすすめ
Temperature Measurement Instruments
The ICL7117RCPL can form the numerical display section of a temperature-measurement instrument when a conditioned analog voltage represents the measured temperature. Its 3.5-digit format naturally supports one or two whole digits and one fractional digit, while the single conversion channel suits a focused panel display. The commercial 0°C to 70°C device rating must remain compatible with the intended ambient environment. A stable reference and appropriate sensor-conditioning network are essential for repeatable readings.
おすすめ
Industrial Process Monitoring
The ICL7117RCPL is suitable for compact process-monitoring equipment that needs a local numerical indication rather than a communications-rich measurement platform. The integrated display-driver architecture reduces the connection count between the measurement circuit and a three-digit seven-segment display. Its through-hole 40-DIP construction supports serviceable industrial instrument boards. The circuit should include defined grounding, reference bypassing, input filtering, and suitable display drive components, with recalibration scheduled around the accuracy of the complete analog signal chain.
おすすめ
Laboratory Measurement Readouts
The ICL7117RCPL is useful in laboratory instruments where a measured voltage must be converted into an immediately readable three-digit result. The fixed 3.5-digit output supports straightforward bench equipment such as simple voltage meters, counters, and educational measurement units. Compared with a general-purpose MCU, the dedicated converter can reduce display-control firmware while retaining a recognizable through-hole construction. Calibration should account for the full input path, reference accuracy, display readability, and the temperature range of the finished instrument.
おすすめ
Educational Electronics Instruments
The ICL7117RCPL is well suited to educational meters because it demonstrates analog conversion and seven-segment display control in one package. Students can use the three-digit output to observe sensor voltage, gain, filtering, and reference behavior on a readable display. The 40-DIP footprint is easier to inspect and service on a through-hole training board than a dense surface-mount package. The experiment should still include proper decoupling and input protection so that incorrect wiring or an overvoltage condition does not damage the device.
おすすめ
Sensor Readout Modules
The ICL7117RCPL can provide the readout function in a small sensor interface module that converts a conditioned analog sensor output into a three-digit display. This arrangement is appropriate for pressure, position, level, or other slow-changing measurements where local visualization is more useful than high-rate data acquisition. The one-channel architecture makes the application straightforward, but the chosen sensor must remain within the converter's input and reference limits. Filtering, calibration, and display persistence should be tuned to the expected rate and noise of the sensor.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: ICL7117RCPL — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | ICL7117CPM | ICL7117CPZ | ICL7117CPMZ | ICL7117CS | ICL7117CP |
|---|---|---|---|---|---|---|
| Package | 40-DIP | 40-DIP | 40-DIP | 40-DIP | 40-DIP | 40-DIP |
| Brand | Harris Corporation | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated |
| Product Type | 3.5-digit display driver ADC | 3.5-digit display driver ADC | 3.5-digit display driver ADC | 3.5-digit display driver ADC | 3.5-digit display driver ADC | 3.5-digit display driver ADC |
| Number of Channels | 1 channel | 1 channel | 1 channel | 1 channel | 1 channel | 1 channel |
| Display Format | 3.5 digits | 3.5 digits | 3.5 digits | 3.5 digits | 3.5 digits | 3.5 digits |
| Mounting Style | Through hole | Through hole | Through hole | Through hole | Through hole | Through hole |
| Number of Terminals | 40 terminals | 40 terminals | 40 terminals | 40 terminals | 40 terminals | 40 terminals |
| ADC Resolution | 3.5-digit display resolution | 3.5-digit display resolution | 3.5-digit display resolution | 3.5-digit display resolution | 3.5-digit display resolution | 3.5-digit display resolution |
主な差別化要因
- Integrated three-digit display interface (vs ICL7117CPM)
- Single-package measurement and display function (vs ICL7117CPZ)
- Commercial through-hole package (vs ICL7117CPMZ)
設計ノート
Treat the analog input and reference paths as sensitive nets. Route them away from display outputs and switching nodes, use the bypass and filtering network shown in the manufacturer application circuit, and connect the analog and digital return paths according to the datasheet grounding diagram. The 40-DIP footprint must accommodate all 40 physical terminals, and signal assignments should be verified directly against the manufacturer pin-description table before PCB release.
Do not select an ICL7117-family suffix solely from its package drawing. The suffix may identify package material, temperature grade, qualification, or commercial ordering conditions that affect the approved operating envelope. For a drop-in decision, compare supply limits, conversion behavior, reference requirements, display outputs, and every terminal function. Also account for seven-segment display current and polarity rather than treating the display outputs as unrestricted logic outputs.
Stability of the displayed measurement depends on the complete analog chain, not only the converter. Provide adequate filtering for sensor noise, maintain a stable reference, use suitable input grounding, and observe the prescribed capacitor types and placement. If the source impedance is high, account for settling time in the conversion cycle. For long PCB routes or noisy industrial environments, shield or guard the input according to the manufacturer’s recommended layout.