INA166UA/2K5 - 2000-Gain Low-Noise INA | Texas Instruments
部品番号: INA166UA/2K5 ✓ 生産中INA166UA/2K5 概要
An instrumentation amplifier is a precision analog signal-conditioning IC used to amplify small differential voltages embedded in larger common-mode signals. Its internal architecture provides accurate differential gain, high input impedance, and good common-mode rejection. The INA166 belongs to the instrumentation-amplifier hierarchy within amplifier ICs and analog signal-chain components, where it is used to condition sensor, microphone, and low-voltage measurement signals.
The principal feature of the INA166UA/2K5 is its internally set gain of 2000. This allows millivolt-level inputs to be amplified into a range more suitable for measurement, conversion, or observation by downstream circuitry. Its low-noise and low-distortion characteristics make it useful when signal integrity must be preserved through the amplification stage. The 450 kHz bandwidth and 15 V/us slew rate support accurate response to signal components well above the audio band.
The INA166 uses current-feedback circuitry to achieve wide bandwidth and strong dynamic response over its gain range. This is particularly valuable in applications requiring a high closed-loop gain while retaining useful signal bandwidth. The single-channel SOIC-14 implementation simplifies design around a compact 14-pin footprint, while the fixed-gain configuration removes the need for an external gain-setting resistor network.
Typical uses include low-level microphone or hydrophone amplification, bridge-sensor signal conditioning, precision measurement instrumentation, and analog front ends for data-acquisition systems. The part can also serve low-amplitude differential signals when the source impedance and common-mode range are compatible with the input stage. Its wide bandwidth makes it more appropriate for waveform and instrumentation applications than for ultra-low-frequency-only signal chains.
Design the input and output paths for the high gain of 2000. Check source impedance, input common-mode voltage, output swing, and the bandwidth required by the source. A differential filter and shielded signal path can help control high-frequency noise, while short, symmetric routing reduces conversion of common-mode interference into differential error.
This page combines the manufacturer specifications, ordering information, comparison data, and practical design guidance for the INA166UA/2K5. It also identifies order-code alternatives and explains where a redesign is required when another instrumentation amplifier uses different gain settings or a different pin arrangement.
ドロップイン代替品: INA166UA/2K5 — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: INA166UA/2K5 (同一形状・フットプリント) — 相違点: Package, Amplifier Type, Gain, Operating Temperature, Slew Rate.
INA166UA
✅ ドロップイン価格はお問い合わせください
データシートを見る →INA166UAG4
✅ ドロップイン📋 参考代替品(カタログ未掲載)
INA166UA/2K5G4
✅ ドロップイン📋 参考代替品(カタログ未掲載)
INA166UA/2K5 最大定格&電気的特性
| Amplifier Type | Instrumentation amplifier |
| Number of Channels | 1 channel |
| Gain | 2000 V/V |
| Gain Configuration | Internally fixed |
| Bandwidth | 450 kHz |
| Slew Rate | 15 V/us |
| 電源電圧 | +/-18 V |
| パッケージ | 14-pin SOIC |
| 実装タイプ | Surface mount |
| 動作温度 | -55 °C to +125 °C |
| Reel Quantity | 2500 devices per reel |
INA166UA/2K5 ピン構成
| ピン 1 | NC — Not connected |
| ピン 2 | NC — Not connected |
| ピン 3 | +IN — Noninverting input |
| ピン 4 | -IN — Inverting input |
| ピン 5 | V- — Negative supply voltage |
| ピン 6 | REF — Reference voltage input |
| ピン 7 | V+ — Positive supply voltage |
| ピン 8 | OUT — Amplified output |
| ピン 9 | NC — Not connected |
| ピン 10 | NC — Not connected |
| ピン 11 | NC — Not connected |
| ピン 12 | NC — Not connected |
| ピン 13 | NC — Not connected |
| ピン 14 | NC — Not connected |
主な用途
INA166UA/2K5 の用途: 6 件s: Bridge-Sensor Signal Conditioning, Low-Level Microphone Preamplifier, Precision Analog Measurement Front End, Data-Acquisition Front End, Industrial Control and Monitoring, Compact Instrumentation Module.
Bridge-Sensor Signal Conditioning
The INA166UA/2K5 fits bridge-sensor front ends that produce small differential voltages on top of a larger common-mode level. Its fixed gain of 2000 V/V amplifies the bridge imbalance without requiring external gain-setting resistors, while the instrumentation-amplifier architecture supports accurate differential measurement. The 450 kHz bandwidth is suitable for dynamic measurements that extend beyond a static Wheatstone bridge. Check sensor excitation, output swing, input common-mode range, source impedance, and the 2000 V/V gain before committing the circuit. Route the two input traces symmetrically and place filtering close to the device so that cable pickup and parasitic capacitance do not degrade the measured signal.
おすすめ
Low-Level Microphone Preamplifier
The INA166UA/2K5 is appropriate for low-level microphone or hydrophone preamplification when the source output can tolerate the 2000 V/V gain. Its low-noise, low-distortion design preserves small signal components, and its 450 kHz bandwidth is substantially above the audio range. The fixed gain removes gain-setting resistors and makes the circuit appropriate when the microphone output level is known and stable. Confirm that the transducer impedance, polarity, common-mode voltage, and output swing meet the INA166 operating requirements. Use short shielded input routing and controlled grounding to prevent cable noise and ground-potential differences from dominating the amplified result.
おすすめ
Precision Analog Measurement Front End
The INA166UA/2K5 can serve as the first amplification stage in a precision analog measurement system when sensor outputs are in the millivolt range. A gain of 2000 V/V raises those signals to a level that can be filtered and converted by a downstream ADC, while the 450 kHz bandwidth and 15 V/us slew rate support responsive signal reproduction. The single-channel SOIC-14 package makes it practical for compact multi-channel analog boards. Verify the complete signal chain against common-mode limits, output swing, offset, noise, and settling requirements. Reference-ground and return-path design are particularly important because any coupled disturbance is amplified by the same high gain that improves small-signal sensitivity.
おすすめ
Data-Acquisition Front End
The INA166UA/2K5 is useful in data-acquisition equipment that must amplify low-amplitude differential channels before sampling. Its fixed 2000 V/V gain provides consistent channel scaling without external gain networks, while the 450 kHz bandwidth allows the amplifier to cover many measurement-band signals. The 15 V/us slew rate helps preserve the shape of larger waveform components after amplification. Engineer the input path for the source impedance and required common-mode range, and confirm that the output remains within the supply-driven swing at the selected gain. For multiplexed systems, allow sufficient settling time between channel changes so stored charge and filtering do not introduce acquisition errors.
おすすめ
Industrial Control and Monitoring
The INA166UA/2K5 supports industrial monitoring functions that detect small voltage changes in noisy environments, provided the installation protects the input path from excessive common-mode voltage and ground offsets. The instrumentation-amplifier configuration is intended to extract differential information, and its 450 kHz bandwidth permits response to changing process or machine signals. The internal gain of 2000 V/V makes it especially useful for small sensor outputs, but it also increases sensitivity to leakage and high-frequency pickup. Use an isolated or protected analog front end where required, maintain a low-impedance reference return, and validate common-mode and transient conditions before deploying the amplifier in control loops.
おすすめ
Compact Instrumentation Module
The INA166UA/2K5 is suitable for a compact instrumentation module requiring one fixed-gain differential input channel in a 14-pin SOIC footprint. Its internally set gain of 2000 V/V simplifies calibration by eliminating an external gain-set network, while the compact package supports higher board density than larger instrumentation-amplifier packages. The 450 kHz bandwidth and 15 V/us slew rate provide useful headroom above slow sensor bandwidth. Pay close attention to thermal conditions, bypass-capacitor placement, and leakage around high-impedance inputs. For multichannel modules, duplicate the analog topology consistently and keep sensitive input nodes away from switching nodes, clock lines, and digital return currents.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: INA166UA/2K5 — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | INA166UA | INA166UAG4 | INA166UA/2K5G4 |
|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 14-pin SOIC | 14-pin SOIC | 14-pin SOIC | 14-pin SOIC |
| Amplifier Type | Single-channel instrumentation amplifier | Single-channel instrumentation amplifier | Single-channel instrumentation amplifier | Single-channel instrumentation amplifier |
| Gain | 2000 V/V | 2000 V/V | 2000 V/V | 2000 V/V |
| Bandwidth | 450 kHz | 450 kHz | 450 kHz | 450 kHz |
| Slew Rate | 15 V/us | 15 V/us | 15 V/us | 15 V/us |
| Maximum Supply Voltage | +/-18 V | +/-18 V | +/-18 V | +/-18 V |
| Special Feature | Low-noise, low-distortion, fixed-gain instrumentation amplifier | Low-noise, low-distortion, fixed-gain instrumentation amplifier | Low-noise, low-distortion, fixed-gain instrumentation amplifier | Low-noise, low-distortion, fixed-gain instrumentation amplifier |
主な差別化要因
- Fixed high gain simplifies the signal path (vs INA166UA)
- Electrical parity with a direct order-code alternative (vs INA166UAG4)
- Reel-oriented ordering for production assembly (vs INA166UA/2K5G4)
設計ノート
Route the differential input traces as a compact, approximately symmetrical pair and connect the two inputs close to the IC. At 2000 V/V gain, parasitic capacitance, unequal routing, and leakage into the input nodes can reduce stability or disturb the differential signal. Keep the reference and output routing away from high-current switching paths, and use a continuous ground plane beneath the analog section.
Check the common-mode voltage at the inputs against the electrical characteristics before applying the full 2000 V/V gain. The amplified output must also remain within the available supply-dependent swing. A signal that is valid at the input can clip at the output when its differential amplitude is large, and an incorrect reference connection can also exceed the output range. Validate both conditions with the intended supply configuration.
Place bypass capacitors close to the supply pins and use a quiet analog return for the input reference. If the source is capable of driving the input network, terminate or filter it according to the required measurement bandwidth. Do not assume that a large number of capacitors improves the result: excessive input capacitance can alter phase margin, particularly where cable or sensor capacitance is unavoidable.
Decouple each supply rail locally and establish the reference to the analog ground without introducing return-current paths through the sensitive input traces. Because the device has fixed gain of 2000 V/V, supply ripple and ground disturbance appear at the output with substantial amplification. Use the manufacturer supply recommendations and evaluate the populated PCB for both normal operation and worst-case startup behavior.
コンプライアンス情報
The available manufacturer and distributor material does not state a definitive RoHS, REACH, lead-free, halogen-free, or conflict-minerals status for this order code. AEC-Q100 qualification is not applicable to the listed commercial instrumentation-amplifier configuration.