KSZ8001LI-TR - 10/100 PHY Transceiver, MII/RMII/SMII | Microchip
部品番号: KSZ8001LI-TR ✓ 生産中| 数量 | 単価 | 小計 |
|---|---|---|
| 1 | $7.03 | $7.03 |
| 10 | $6.32 | $63.20 |
| 100 | $5.53 | $553.00 |
| 500 | $4.85 | $2,425.00 |
| 1,000 | $4.3 | $4,300.00 |
KSZ8001LI-TR 概要
What is an Ethernet PHY transceiver? A Physical Layer device (PHY) is the analog front-end of an Ethernet link, sitting between the digital MAC controller and the magnetic transformer/RJ-45 connector. The PHY handles line coding (MLT-3 for 100BASE-TX, Manchester for 10BASE-T), clock/data recovery, adaptive equalization, and link-pulse detection. The KSZ8001LI-TR belongs to the Fast Ethernet (100 Mbps) PHY family, which falls under Interface ICs -> Network Interface -> Ethernet Transceiver in the broader semiconductor hierarchy.
Key differentiating features include LinkMD TDR-based cable diagnostics that detect open/short conditions and report cable length up to 200m with ±2m accuracy, robust operation over standard Cat-5 cables up to 130m+, HP Auto-MDIX support for automatic crossover detection, and flexible MII/RMII/SMII host bus selection that lets the same PHY connect to MACs with different pin-count constraints. The device supports both copper (100BASE-TX, 10BASE-T) and fiber (100BASE-FX) media via an external fiber transceiver.
The KSZ8001LI-TR architecture uses a 3.3V analog supply plus a 1.8V digital core derived from an internal LDO, with separate VDDIO rails supporting 3.3V or 2.5V MAC interface voltages. Typical power consumption is 172 mW. The PHY connects to a MAC via parallel MII (18 pins), reduced MII (RMII, ~9 pins), or serial MII (SMII, 4 pins), configured at reset via strap pins. Auto-negotiation follows IEEE 802.3u Clause 28.
Typical applications include industrial Ethernet IP cameras, factory automation PLCs, networked printers, set-top box Ethernet ports, embedded IoT gateways with wired connectivity, and any embedded system requiring a small-footprint 10/100 Ethernet PHY with diagnostic capability. The LinkMD feature is particularly valuable in managed switches and remote installations where cable fault localization reduces service calls.
Design considerations include providing a 25 MHz reference clock (or 50 MHz for RMII), placing the device within 25 mm of the magnetic transformer, implementing proper 50 ohm differential routing for the MDI traces, and supplying adequate decoupling (0.1 uF plus 10 uF bulk) on each supply rail. The KSZ8001LI-TR differs from the -L variant (KSZ8001L) by offering higher-grade industrial temperature support and the -TR suffix denotes Tape and Reel packaging.
This page synthesizes distributor pricing as of 2026-10-16, real drop-in alternatives sourced from cross-reference databases, and practical engineering considerations to accelerate Ethernet PHY selection beyond the bare manufacturer datasheet.
ドロップイン代替品: KSZ8001LI-TR — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: KSZ8001LI-TR (同一形状・フットプリント) — 相違点: Auto-Negotiation, Operating Temperature, Package, Reference Clock.
クイック比較ツール — 並列比較する代替部品を選択:
KSZ8001LI
✅ ドロップイン📋 参考代替品(カタログ未掲載)
KSZ8001LIS-TR
✅ ドロップイン📋 参考代替品(カタログ未掲載)
KSZ8001LTR
✅ ドロップイン✓ 在庫あり
$2.34 / 個
データシートを見る →KSZ8001LI
✅ ドロップイン📋 参考代替品(カタログ未掲載)
KSZ8001S
✅ ドロップイン📋 参考代替品(カタログ未掲載)
KSZ8001LI-TR 仕様
| 機能 | 10/100BASE-TX/100BASE-FX Physical Layer Transceiver |
| Host Interface | MII, RMII, SMII (selectable via strap pins) |
| Supply Voltage (Analog) | 3.3 V |
| Supply Voltage (Core) | 1.8 V (internal LDO from 3.3 V) |
| Supply Voltage (VDDIO) | 3.3 V or 2.5 V |
| Typical Power Consumption | 172 mW |
| Cable Reach (TX/Copper) | 130 m+ standard Cat-5 |
| Cable Diagnostics | LinkMD TDR, up to 200 m, ±2 m accuracy |
| Fiber Support | 100BASE-FX via external transceiver |
| Auto-MDIX | Yes (HP Auto-MDIX) |
| Auto-Negotiation | IEEE 802.3u Clause 28 |
| Reference Clock | 25 MHz (50 MHz for RMII) |
| 動作温度 | -40 C to +85 C |
| パッケージ | 48-LQFP (7 x 7 mm) |
| 実装タイプ | Surface Mount |
| Packaging | Tape & Reel (-TR suffix) |
| RoHS ステータス | Compliant (RoHS3 per distributor data) |
| Lead-Free | Yes |
KSZ8001LI-TR ピン構成
| ピン 1 | TXRXP_A — Differential transmit/receive pair A (MDI, to magnetics) |
| ピン 2 | TXRXM_A — Differential transmit/receive pair A (MDI, to magnetics) |
| ピン 3 | AVDD_33 — Analog 3.3V supply |
| ピン 4 | TXRXP_B — Differential transmit/receive pair B (MDI, to magnetics) |
| ピン 5 | TXRXM_B — Differential transmit/receive pair B (MDI, to magnetics) |
| ピン 6 | TXRXP_C — Differential transmit/receive pair C (MDI, to magnetics) |
| ピン 7 | TXRXM_C — Differential transmit/receive pair C (MDI, to magnetics) |
| ピン 8 | TXRXP_D — Differential transmit/receive pair D (MDI, to magnetics) |
| ピン 9 | TXRXM_D — Differential transmit/receive pair D (MDI, to magnetics) |
| ピン 10 | AGND — Analog ground |
| ピン 11 | VDDIO — MAC I/O supply (3.3V or 2.5V) |
| ピン 12 | MODE2 — Host interface mode strap 2 |
| ピン 13 | MODE1 — Host interface mode strap 1 |
| ピン 14 | MODE0 — Host interface mode strap 0 |
| ピン 15 | RST# — Hardware reset (active low) |
| ピン 16 | MDC — Management data clock (SMI) |
| ピン 17 | MDIO — Management data I/O (SMI) |
| ピン 18 | INT# — Interrupt output (active-low) |
| ピン 19 | RXD0 — Receive data bit 0 / strap |
| ピン 20 | RXD1 — Receive data bit 1 / strap |
| ピン 21 | RXD2 — Receive data bit 2 / strap (MII only) |
| ピン 22 | RXD3 — Receive data bit 3 / strap (MII only) |
| ピン 23 | RXDV — Receive data valid / strap |
| ピン 24 | RXC — Receive clock / strap |
| ピン 25 | RXER — Receive error / strap |
| ピン 26 | TXD0 — Transmit data bit 0 |
| ピン 27 | TXD1 — Transmit data bit 1 |
| ピン 28 | TXD2 — Transmit data bit 2 (MII only) |
| ピン 29 | TXD3 — Transmit data bit 3 (MII only) |
| ピン 30 | TXEN — Transmit enable |
| ピン 31 | TXC — Transmit clock |
| ピン 32 | TXER — Transmit error |
| ピン 33 | COL — Collision detect |
| ピン 34 | CRS — Carrier sense |
| ピン 35 | VDDIO — MAC I/O supply (3.3V or 2.5V) |
| ピン 36 | GND — Digital ground |
| ピン 37 | XI — 25 MHz reference clock input (50 MHz for RMII) |
| ピン 38 | XO — 25 MHz reference clock output |
| ピン 39 | AVDD_33 — Analog 3.3V supply |
| ピン 40 | AGND — Analog ground |
| ピン 41 | FXSD — Fiber signal detect (100BASE-FX) |
| ピン 42 | NC — Not connected (per datasheet) |
| ピン 43 | NC — Not connected (per datasheet) |
| ピン 44 | LED0/REF_CLK — Status LED 0 or 50 MHz RMII reference output |
| ピン 45 | LED1 — Status LED 1 (link/activity) |
| ピン 46 | LED2 — Status LED 2 (speed) |
| ピン 47 | AVDD_18 — Internal 1.8V core LDO output (decouple) |
| ピン 48 | AVDD_33 — Analog 3.3V supply |
主な用途
KSZ8001LI-TR の用途: 6 件s: Industrial Ethernet IP Cameras, Factory Automation PLCs and I/O Modules, Networked Printers and MFPs, Set-Top Box Ethernet Ports, IoT Gateways with Wired Connectivity, 100BASE-FX Fiber Media Converters.
Industrial Ethernet IP Cameras
The KSZ8001LI-TR is well suited to industrial IP camera designs where robust cable operation and built-in cable diagnostics reduce field service calls. Its 130m+ cable reach over standard Cat-5 plus LinkMD TDR diagnostics with ±2m accuracy up to 200m let installers localize cable faults without separate TDR instruments. Industrial -40C to +85C operation supports outdoor PoE-powered camera housings, and the flexible MII/RMII/SMII host interface integrates easily with common camera SoCs. At 172 mW typical power, the device adds minimal thermal load inside sealed camera enclosures.
おすすめ
Factory Automation PLCs and I/O Modules
The KSZ8001LI-TR fits PLCs and remote I/O modules that require deterministic 10/100 Ethernet on industrial cabling. The robust 130m+ reach handles long factory floor cable runs, and HP Auto-MDIX eliminates crossover-cable errors in service. The PHY's industrial -40C to +85C rating covers unheated cabinet environments, while the MII or RMII host interface integrates with ARM-based PLC CPUs. LinkMD aids maintenance technicians in tracing cable faults across distributed I/O installations without disassembling cabinets.
おすすめ
Networked Printers and MFPs
Office MFPs and networked printers benefit from the KSZ8001LI-TR's compact 48-LQFP footprint and low 172 mW typical power dissipation. The PHY connects to MFP SoCs via MII, RMII, or SMII and supports full-duplex 100BASE-TX for fast image transfer and scan-to-email workflows. Auto-MDIX auto-detects straight-through vs crossover patch cables, eliminating installation errors. The 3.3V/2.5V VDDIO flexibility supports MFP controllers on either supply domain without level shifters.
おすすめ
Set-Top Box Ethernet Ports
Set-top boxes and IPTV gateways commonly use the KSZ8001LI-TR as their primary Ethernet PHY because of its small LQFP-48 footprint and minimal external BOM. The device supports full-duplex 100BASE-TX for video streaming and SMII mode for cost-sensitive SoCs with limited GPIO. Auto-negotiation to 10BASE-T is automatic for legacy networks, and the 25 MHz reference can be shared with other system peripherals. Industrial temperature option suits outdoor enclosure variants.
おすすめ
IoT Gateways with Wired Connectivity
IoT gateways bridging wired Ethernet to wireless peripherals (Wi-Fi, Bluetooth, LoRa, Zigbee) use the KSZ8001LI-TR as the wired uplink PHY. Its RMII mode keeps pin count low, freeing MCU/SoC pins for wireless transceivers, while LinkMD helps field technicians diagnose installed cable plants during commissioning. Industrial temperature rating supports outdoor gateways, and 172 mW typical power is acceptable for solar/battery-powered edge gateways running intermittently.
おすすめ
100BASE-FX Fiber Media Converters
The KSZ8001LI-TR's 100BASE-FX support lets it serve as the PHY inside copper-to-fiber media converters, where it connects to an external PECL fiber transceiver while keeping the MII/RMII host side digital. Industrial temperature rating supports outdoor converter housings, and LinkMD diagnostics operate over copper segments of the link. The compact 48-LQFP package leaves room for the fiber transceiver and magnetics in DIN-rail media converter designs.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: KSZ8001LI-TR — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | KSZ8001LI | KSZ8001LIS-TR | KSZ8001L | KSZ8001S |
|---|---|---|---|---|---|
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Package | 48-LQFP (7x7 mm) | 48-LQFP - same | 48-LQFP - same | 48-LQFP - same | 48-LQFP - same |
主な差別化要因
- Triple host interface (MII/RMII/SMII) on one PHY (vs KSZ8721BLI (older Microchip 10/100 PHY))
- Built-in LinkMD TDR cable diagnostics (vs KSZ8001L (commercial temp variant))
- Industrial -40C to +85C operating range with same footprint (vs KSZ8001L (commercial 0C to +70C))
設計ノート
Place the KSZ8001LI-TR within 25 mm of the Ethernet magnetic transformer module and route the four MDI differential pairs (TXRXP/M_A through _D) as 100 ohm differential traces on the top layer with matched length within 2 mm and a continuous ground reference plane directly below. Keep MDI traces away from switching regulator, oscillator, and high-speed digital signals. Place the 0.1 uF supply decoupling capacitors within 2 mm of each supply pin and a 10 uF bulk cap within 5 mm. Per the KSZ8001L/S datasheet, improper grounding or excessive trace length will fail IEEE 802.3 return loss compliance.
Provide clean 3.3 V analog and digital supplies to the KSZ8001LI-TR. The internal LDO derives 1.8 V from the 3.3 V analog rail and supplies the digital core; decouple AVDD_18 with a 1 uF plus 0.1 uF cap as the datasheet instructs. The device draws 172 mW typical, so a switching regulator followed by an LDO post-regulator is recommended to suppress ripple coupling into the analog MDI front-end. Avoid daisy-chaining digital and analog ground returns through a single via.
Avoid these common KSZ8001LI-TR design pitfalls: (1) forgetting the 25 MHz crystal or 50 MHz RMII reference clock requirement - both modes need a stable reference within ±50 ppm; (2) leaving the MODE[2:0] strap pins floating - they must be tied high or low with 4.7 kohm resistors to select MII/RMII/SMII mode; (3) connecting a 5 V MAC to VDDIO when VDDIO is set to 2.5 V - this damages the I/O pins; (4) routing the MDIO/MDC traces longer than 50 mm without a series termination resistor; (5) using an RJ-45 without integrated magnetics as the KSZ8001LI-TR expects a 1:1 transformer in the MDI path.
コンプライアンス情報
RoHS3 compliant per Alibaba and DiGi Electronics product listings. Not AEC-Q100 qualified (PHYs rarely are; this is an industrial-temp grade, not automotive). Lead-free per KSZ8001L/S datasheet.