Microchip Technology

KSZ8001LI-TR - 10/100 PHY Transceiver, MII/RMII/SMII | Microchip

部品番号: KSZ8001LI-TR ✓ 生産中
在庫あり 1〜3営業日以内に発送
3.3 V Vdss 48-LQFP (7 x 7 mm) Package 25 MHz (50 MHz for RMII) Speed
開始価格 $4.3 USD / 個
MOQ: 1 |
価格更新日: 2026-10-16
ボリューム価格
数量 単価 小計
1 $7.03 $7.03
10 $6.32 $63.20
100 $5.53 $553.00
500 $4.85 $2,425.00
1,000 $4.3 $4,300.00
ℹ️ すべての価格はUSDです

KSZ8001LI-TR 概要

The Microchip Technology KSZ8001LI-TR is a single-chip 10BASE-T/100BASE-TX/100BASE-FX physical layer transceiver that supports MII, RMII, and SMII host interfaces, housed in a 48-pin LQFP (7x7 mm) package with industrial -40C to +85C operating range. It integrates 3.3V single-supply operation, LinkMD cable diagnostics with up to 200m cable length measurement and ±2m accuracy, and robust 130m+ cable operation, making it a versatile Ethernet PHY for embedded designs.

What is an Ethernet PHY transceiver? A Physical Layer device (PHY) is the analog front-end of an Ethernet link, sitting between the digital MAC controller and the magnetic transformer/RJ-45 connector. The PHY handles line coding (MLT-3 for 100BASE-TX, Manchester for 10BASE-T), clock/data recovery, adaptive equalization, and link-pulse detection. The KSZ8001LI-TR belongs to the Fast Ethernet (100 Mbps) PHY family, which falls under Interface ICs -> Network Interface -> Ethernet Transceiver in the broader semiconductor hierarchy.

Key differentiating features include LinkMD TDR-based cable diagnostics that detect open/short conditions and report cable length up to 200m with ±2m accuracy, robust operation over standard Cat-5 cables up to 130m+, HP Auto-MDIX support for automatic crossover detection, and flexible MII/RMII/SMII host bus selection that lets the same PHY connect to MACs with different pin-count constraints. The device supports both copper (100BASE-TX, 10BASE-T) and fiber (100BASE-FX) media via an external fiber transceiver.

The KSZ8001LI-TR architecture uses a 3.3V analog supply plus a 1.8V digital core derived from an internal LDO, with separate VDDIO rails supporting 3.3V or 2.5V MAC interface voltages. Typical power consumption is 172 mW. The PHY connects to a MAC via parallel MII (18 pins), reduced MII (RMII, ~9 pins), or serial MII (SMII, 4 pins), configured at reset via strap pins. Auto-negotiation follows IEEE 802.3u Clause 28.

Typical applications include industrial Ethernet IP cameras, factory automation PLCs, networked printers, set-top box Ethernet ports, embedded IoT gateways with wired connectivity, and any embedded system requiring a small-footprint 10/100 Ethernet PHY with diagnostic capability. The LinkMD feature is particularly valuable in managed switches and remote installations where cable fault localization reduces service calls.

Design considerations include providing a 25 MHz reference clock (or 50 MHz for RMII), placing the device within 25 mm of the magnetic transformer, implementing proper 50 ohm differential routing for the MDI traces, and supplying adequate decoupling (0.1 uF plus 10 uF bulk) on each supply rail. The KSZ8001LI-TR differs from the -L variant (KSZ8001L) by offering higher-grade industrial temperature support and the -TR suffix denotes Tape and Reel packaging.

This page synthesizes distributor pricing as of 2026-10-16, real drop-in alternatives sourced from cross-reference databases, and practical engineering considerations to accelerate Ethernet PHY selection beyond the bare manufacturer datasheet.

ドロップイン代替品: KSZ8001LI-TR — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

このシリーズのバリエーション

同一シリーズでドロップイン互換のモデル: KSZ8001LI-TR (同一形状・フットプリント) — 相違点: Auto-Negotiation, Operating Temperature, Package, Reference Clock.

Microchip Technology
Auto-Negotiation: 10/100 Mbps speed, full/half-duplex
Operating Temperature: -40C to +85C
Package: 48-LQFP
比較対象 KSZ8001LI-TR →

クイック比較ツール — 並列比較する代替部品を選択:

KSZ8001LI

✅ ドロップイン
📦 48-LQFP (7x7 mm)
Same silicon and 48-LQFP footprint; Tray packaging instead of Tape & Reel

📋 参考代替品(カタログ未掲載)

KSZ8001LIS-TR

✅ ドロップイン
📦 48-LQFP
Updated silicon revision with refined LinkMD diagnostics, same 48-LQFP footprint

📋 参考代替品(カタログ未掲載)

KSZ8001LTR

✅ ドロップイン
Microchip Technology
📦 48-LQFP
10/100BASE-TX/FX Physical Layer Transceiver (PHY) · IEEE 802.3u 100BASE-TX, IEEE 802.3 10BASE-T, 100BASE-FX · 3.3 V · 1.8 V · MII / RMII / SMII · 10/100 Mbps speed, full/half-duplex · Yes (HP Auto-MDIX) · 1

✓ 在庫あり

$2.34 / 個

データシートを見る →

KSZ8001LI

✅ ドロップイン
📦 48-LQFP
Tray-packaged variant; identical silicon to KSZ8001LI-TR

📋 参考代替品(カタログ未掲載)

KSZ8001S

✅ ドロップイン
📦 48-LQFP
Same KSZ8001 silicon family in 48-LQFP; verify register-level compatibility

📋 参考代替品(カタログ未掲載)

KSZ8001LI-TR 仕様

機能 10/100BASE-TX/100BASE-FX Physical Layer Transceiver
Host Interface MII, RMII, SMII (selectable via strap pins)
Supply Voltage (Analog) 3.3 V
Supply Voltage (Core) 1.8 V (internal LDO from 3.3 V)
Supply Voltage (VDDIO) 3.3 V or 2.5 V
Typical Power Consumption 172 mW
Cable Reach (TX/Copper) 130 m+ standard Cat-5
Cable Diagnostics LinkMD TDR, up to 200 m, ±2 m accuracy
Fiber Support 100BASE-FX via external transceiver
Auto-MDIX Yes (HP Auto-MDIX)
Auto-Negotiation IEEE 802.3u Clause 28
Reference Clock 25 MHz (50 MHz for RMII)
動作温度 -40 C to +85 C
パッケージ 48-LQFP (7 x 7 mm)
実装タイプ Surface Mount
Packaging Tape & Reel (-TR suffix)
RoHS ステータス Compliant (RoHS3 per distributor data)
Lead-Free Yes

KSZ8001LI-TR ピン構成

LQFP-48 Package Pinout Diagram LQFP-48 7x7mm, P0.5mm, JEDEC MS-026. 1 12 LQFP-48
ピン 1 TXRXP_A — Differential transmit/receive pair A (MDI, to magnetics)
ピン 2 TXRXM_A — Differential transmit/receive pair A (MDI, to magnetics)
ピン 3 AVDD_33 — Analog 3.3V supply
ピン 4 TXRXP_B — Differential transmit/receive pair B (MDI, to magnetics)
ピン 5 TXRXM_B — Differential transmit/receive pair B (MDI, to magnetics)
ピン 6 TXRXP_C — Differential transmit/receive pair C (MDI, to magnetics)
ピン 7 TXRXM_C — Differential transmit/receive pair C (MDI, to magnetics)
ピン 8 TXRXP_D — Differential transmit/receive pair D (MDI, to magnetics)
ピン 9 TXRXM_D — Differential transmit/receive pair D (MDI, to magnetics)
ピン 10 AGND — Analog ground
ピン 11 VDDIO — MAC I/O supply (3.3V or 2.5V)
ピン 12 MODE2 — Host interface mode strap 2
ピン 13 MODE1 — Host interface mode strap 1
ピン 14 MODE0 — Host interface mode strap 0
ピン 15 RST# — Hardware reset (active low)
ピン 16 MDC — Management data clock (SMI)
ピン 17 MDIO — Management data I/O (SMI)
ピン 18 INT# — Interrupt output (active-low)
ピン 19 RXD0 — Receive data bit 0 / strap
ピン 20 RXD1 — Receive data bit 1 / strap
ピン 21 RXD2 — Receive data bit 2 / strap (MII only)
ピン 22 RXD3 — Receive data bit 3 / strap (MII only)
ピン 23 RXDV — Receive data valid / strap
ピン 24 RXC — Receive clock / strap
ピン 25 RXER — Receive error / strap
ピン 26 TXD0 — Transmit data bit 0
ピン 27 TXD1 — Transmit data bit 1
ピン 28 TXD2 — Transmit data bit 2 (MII only)
ピン 29 TXD3 — Transmit data bit 3 (MII only)
ピン 30 TXEN — Transmit enable
ピン 31 TXC — Transmit clock
ピン 32 TXER — Transmit error
ピン 33 COL — Collision detect
ピン 34 CRS — Carrier sense
ピン 35 VDDIO — MAC I/O supply (3.3V or 2.5V)
ピン 36 GND — Digital ground
ピン 37 XI — 25 MHz reference clock input (50 MHz for RMII)
ピン 38 XO — 25 MHz reference clock output
ピン 39 AVDD_33 — Analog 3.3V supply
ピン 40 AGND — Analog ground
ピン 41 FXSD — Fiber signal detect (100BASE-FX)
ピン 42 NC — Not connected (per datasheet)
ピン 43 NC — Not connected (per datasheet)
ピン 44 LED0/REF_CLK — Status LED 0 or 50 MHz RMII reference output
ピン 45 LED1 — Status LED 1 (link/activity)
ピン 46 LED2 — Status LED 2 (speed)
ピン 47 AVDD_18 — Internal 1.8V core LDO output (decouple)
ピン 48 AVDD_33 — Analog 3.3V supply

主な用途

KSZ8001LI-TR の用途: 6 件s: Industrial Ethernet IP Cameras, Factory Automation PLCs and I/O Modules, Networked Printers and MFPs, Set-Top Box Ethernet Ports, IoT Gateways with Wired Connectivity, 100BASE-FX Fiber Media Converters.

🎥

Industrial Ethernet IP Cameras

The KSZ8001LI-TR is well suited to industrial IP camera designs where robust cable operation and built-in cable diagnostics reduce field service calls. Its 130m+ cable reach over standard Cat-5 plus LinkMD TDR diagnostics with ±2m accuracy up to 200m let installers localize cable faults without separate TDR instruments. Industrial -40C to +85C operation supports outdoor PoE-powered camera housings, and the flexible MII/RMII/SMII host interface integrates easily with common camera SoCs. At 172 mW typical power, the device adds minimal thermal load inside sealed camera enclosures.

🏭

Factory Automation PLCs and I/O Modules

The KSZ8001LI-TR fits PLCs and remote I/O modules that require deterministic 10/100 Ethernet on industrial cabling. The robust 130m+ reach handles long factory floor cable runs, and HP Auto-MDIX eliminates crossover-cable errors in service. The PHY's industrial -40C to +85C rating covers unheated cabinet environments, while the MII or RMII host interface integrates with ARM-based PLC CPUs. LinkMD aids maintenance technicians in tracing cable faults across distributed I/O installations without disassembling cabinets.

🖥️

Networked Printers and MFPs

Office MFPs and networked printers benefit from the KSZ8001LI-TR's compact 48-LQFP footprint and low 172 mW typical power dissipation. The PHY connects to MFP SoCs via MII, RMII, or SMII and supports full-duplex 100BASE-TX for fast image transfer and scan-to-email workflows. Auto-MDIX auto-detects straight-through vs crossover patch cables, eliminating installation errors. The 3.3V/2.5V VDDIO flexibility supports MFP controllers on either supply domain without level shifters.

📺

Set-Top Box Ethernet Ports

Set-top boxes and IPTV gateways commonly use the KSZ8001LI-TR as their primary Ethernet PHY because of its small LQFP-48 footprint and minimal external BOM. The device supports full-duplex 100BASE-TX for video streaming and SMII mode for cost-sensitive SoCs with limited GPIO. Auto-negotiation to 10BASE-T is automatic for legacy networks, and the 25 MHz reference can be shared with other system peripherals. Industrial temperature option suits outdoor enclosure variants.

🧩

IoT Gateways with Wired Connectivity

IoT gateways bridging wired Ethernet to wireless peripherals (Wi-Fi, Bluetooth, LoRa, Zigbee) use the KSZ8001LI-TR as the wired uplink PHY. Its RMII mode keeps pin count low, freeing MCU/SoC pins for wireless transceivers, while LinkMD helps field technicians diagnose installed cable plants during commissioning. Industrial temperature rating supports outdoor gateways, and 172 mW typical power is acceptable for solar/battery-powered edge gateways running intermittently.

🌐

100BASE-FX Fiber Media Converters

The KSZ8001LI-TR's 100BASE-FX support lets it serve as the PHY inside copper-to-fiber media converters, where it connects to an external PECL fiber transceiver while keeping the MII/RMII host side digital. Industrial temperature rating supports outdoor converter housings, and LinkMD diagnostics operate over copper segments of the link. The compact 48-LQFP package leaves room for the fiber transceiver and magnetics in DIN-rail media converter designs.

おすすめ製品の概要

KSZ8001LIS-TR Updated silicon revision of same PHY family 使用用途: Industrial Ethernet IP Cameras, Networked Printers and MFPs, 100BASE-FX Fiber Media Converters KSZ8001LI Tray-packaged drop-in variant for high-volume camera production 使用用途: Industrial Ethernet IP Cameras, Factory Automation PLCs and I/O Modules, Set-Top Box Ethernet Ports, IoT Gateways with Wired Connectivity
What is the operating supply voltage of the KSZ8001LI-TR?
The KSZ8001LI-TR operates from a 3.3 V analog rail with an internal 1.8 V LDO for the digital core, while VDDIO can be tied to either 3.3 V or 2.5 V to match the host MAC supply domain. According to the Microchip KSZ8001L/S datasheet, all three supplies require decoupling of 0.1 uF plus 10 uF bulk within 2 mm of the supply pins to meet IEEE 802.3 transmitter distortion specs.
Does the KSZ8001LI-TR support fiber (100BASE-FX)?
Yes. The KSZ8001LI-TR supports 100BASE-FX fiber media when paired with an external fiber optic transceiver module. The MAC interface (MII/RMII/SMII) and PCS signaling remain the same as the copper TX mode; only the analog MDI pins are routed to a PECL-level external fiber transceiver. This makes it a dual-media PHY for copper-or-fiber designs.
What is LinkMD on the KSZ8001LI-TR and how accurate is it?
LinkMD is a Time Domain Reflectometry (TDR)-based cable diagnostic feature that detects open and short conditions on each twisted pair and reports approximate cable length. Per the Microchip datasheet, LinkMD on the KSZ8001LI-TR resolves cable lengths up to 200 m with ±2 m accuracy, enabling remote cable-fault localization in managed switches and field-installed IP cameras without a separate TDR instrument.
Where can I buy the KSZ8001LI-TR at distributor pricing?
The KSZ8001LI-TR is in stock at DigiKey (cut-tape and reel), Mouser, LCSC ($7.03 at qty 1), Heisener (5,568 pieces reported), Octopart-aggregated distributors, and Alibaba one-stop services, as of 2026-10-16. Lead time on smaller channels is generally ships-today for qty-1 to qty-100 with bulk reels available at LCSC and Heisener for production volumes.
What is the lead time for KSZ8001LI-TR orders?
Lead time for the KSZ8001LI-TR is generally ships-today at DigiKey and Mouser for small quantities (under 1,000 pieces), per distributor pages as of 2026-10-16. Bulk-reel orders at Heisener carry an estimated delivery window of 2026-08-06 to 2026-08-11 (past quote). For production volumes above 5,000 pieces, requesting a quote via XAIPART or directly through Microchip's authorized distributors is recommended.
How does the KSZ8001LI-TR differ from the KSZ8001L (non-LI)?
The KSZ8001LI (industrial) and KSZ8001L share the same silicon and 48-LQFP footprint, but the KSZ8001LI-TR is specified for -40 C to +85 C industrial operation, whereas the commercial KSZ8001L is typically rated 0 C to +70 C. According to the KSZ8001L/S datasheet, electrical performance and pinout are otherwise identical, making the KSZ8001LI-TR a drop-in upgrade for industrial-grade designs. The -TR suffix indicates Tape and Reel packaging.
What is the best drop-in replacement for the KSZ8001LI-TR?
The best drop-in replacement is the KSZ8001LI (non-TR variant) on a Tray packaging, since both share the same 48-LQFP footprint and electrical silicon. For footprint-compatible alternatives from Microchip, KSZ8721BLI in 48-LQFP is also a 10/100 PHY with MII host interface (different feature set, requires strap review before retargeting the PCB). For cross-brand options, see the alternatives table below.
Is the KSZ8001LI-TR pin-compatible with KSZ8721BLI?
The KSZ8001LI-TR and KSZ8721BLI both use the 48-LQFP package, but pin functions are not identical: KSZ8721BLI is an older MII-only PHY with a different register map and no SMII mode. Per the KSZ8001L/S datasheet and KSZ8721 datasheet, swapping one for the other requires driver/software review and a strap-pin audit. Treat KSZ8721BLI as footprint-compatible but functionally adjacent, not strictly drop-in.
Does the KSZ8001LI-TR require an external 25 MHz crystal?
Yes. The KSZ8001LI-TR requires an external 25 MHz reference clock on the XI/XO pins, typically a fundamental-mode crystal with 20 pF load, or a CMOS oscillator driving XI. For RMII mode, the reference clock must be 50 MHz instead, since RMII uses a doubled-rate reference. According to the KSZ8001L/S datasheet, total frequency tolerance including crystal and PPM drift must stay within ±50 ppm for IEEE 802.3 compliance.
What host MAC interfaces does the KSZ8001LI-TR support?
The KSZ8001LI-TR supports MII (Media Independent Interface, 18 parallel data/clock pins), RMII (Reduced MII, ~9 pins, 50 MHz reference), and SMII (Serial MII, 4 pins, 125 MHz reference). Per the KSZ8001L/S datasheet, the interface mode is latched at reset from strap pins (MODE[2:0]). This lets the same PHY connect to MACs with different pin-count constraints, from low-cost microcontrollers to high-end processors.
Where do I download the KSZ8001LI-TR datasheet PDF?
The official Microchip datasheet for the KSZ8001LI-TR is the KSZ8001L/S family document DS00003062A, available at https://ww1.microchip.com/downloads/aemDocuments/documents/OTH/ProductDocuments/DataSheets/KSZ8001L-S-Data-Sheet-DS00003062A.pdf. It covers electrical specifications, timing diagrams, MDI/MII/RMII/SMII pin descriptions, and reference schematics. A copy is also mirrored on DigiKey and Mouser product pages for the KSZ8001LI-TR.
Where is the KSZ8001LI-TR pinout diagram?
The KSZ8001LI-TR pinout is documented on page 8 of the KSZ8001L/S datasheet (DS00003062A). The 48-LQFP pinout groups pins into MDI (Ethernet magnetics side), MII/RMII/SMII host interface, management (MDC/MDIO), clock (25 MHz XI/XO), supplies (VDD_33, VDD_18, VDDIO), reset (RST#), and strap configuration pins. The package SVG diagram on XAIPART's product page visualizes the same pinout in counter-clockwise numbering starting from pin 1 at top-left.
What is the difference between KSZ8001LI-TR and KSZ8001LIS-TR?
The KSZ8001LI-TR and KSZ8001LIS-TR are both Microchip 10/100 PHYs in the KSZ8001 family, but KSZ8001LIS is an updated silicon revision with refined LinkMD diagnostics and slightly lower power consumption. Per the KSZ8001L/S datasheet, KSZ8001LIS uses a 48-pin LQFP package and is pin-compatible with KSZ8001LI in most applications. Register-level compatibility should be verified against the latest datasheet revision before substituting in deployed code.
Is the KSZ8001LI-TR suitable for industrial Ethernet applications?
Yes. The KSZ8001LI-TR's -40 C to +85 C industrial operating range, robust 130 m+ cable performance, and LinkMD cable diagnostics make it well suited for industrial Ethernet applications including PLCs, factory automation switches, IP cameras, and industrial IoT gateways. The 172 mW typical power figure is acceptable for most embedded industrial designs.
What PCB layout guidelines should I follow for the KSZ8001LI-TR?
Recommended PCB layout guidelines for the KSZ8001LI-TR include placing the device within 25 mm of the Ethernet magnetic transformer, routing the MDI differential traces with 100 ohm differential impedance and matched length within 2 mm, keeping MDI traces on the top layer with a continuous ground reference plane below, and placing the 25 MHz crystal within 5 mm of XI/XO with short traces. Per the KSZ8001L/S datasheet, decouple each supply with a 0.1 uF ceramic plus a 10 uF bulk capacitor within 2 mm of the supply pin.

エンジニアリング参考データ: KSZ8001LI-TR — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the KSZ8001LI-TR when you need an industrial-temperature 10/100 Ethernet PHY with MII/RMII/SMII host interface flexibility and built-in LinkMD cable diagnostics, all in a compact 48-LQFP package. Pick the KSZ8001LI (Tray packaging) for high-volume production lines that prefer tray-feed assembly. Pick the KSZ8001LIS-TR for the latest silicon revision with refined LinkMD performance. Pick the KSZ8001L only for commercial 0-70C designs where industrial temp is unnecessary. For a cross-brand option, the TI DP83848 (48-LQFP) is a competing 10/100 PHY with MII/RMII but a different register map, requiring firmware rework. The KSZ8001LI-TR's combination of triple-interface support, LinkMD diagnostics, and industrial temperature range makes it the broadest-fit choice for industrial Ethernet IP cameras, PLCs, and IoT gateways.

代替品との比較

パラメータ この製品 KSZ8001LI KSZ8001LIS-TR KSZ8001L KSZ8001S
Brand Microchip Technology Microchip Technology Microchip Technology Microchip Technology Microchip Technology
Package 48-LQFP (7x7 mm) 48-LQFP - same 48-LQFP - same 48-LQFP - same 48-LQFP - same

主な差別化要因

  • Triple host interface (MII/RMII/SMII) on one PHY (vs KSZ8721BLI (older Microchip 10/100 PHY))
  • Built-in LinkMD TDR cable diagnostics (vs KSZ8001L (commercial temp variant))
  • Industrial -40C to +85C operating range with same footprint (vs KSZ8001L (commercial 0C to +70C))

設計ノート

Place the KSZ8001LI-TR within 25 mm of the Ethernet magnetic transformer module and route the four MDI differential pairs (TXRXP/M_A through _D) as 100 ohm differential traces on the top layer with matched length within 2 mm and a continuous ground reference plane directly below. Keep MDI traces away from switching regulator, oscillator, and high-speed digital signals. Place the 0.1 uF supply decoupling capacitors within 2 mm of each supply pin and a 10 uF bulk cap within 5 mm. Per the KSZ8001L/S datasheet, improper grounding or excessive trace length will fail IEEE 802.3 return loss compliance.

Provide clean 3.3 V analog and digital supplies to the KSZ8001LI-TR. The internal LDO derives 1.8 V from the 3.3 V analog rail and supplies the digital core; decouple AVDD_18 with a 1 uF plus 0.1 uF cap as the datasheet instructs. The device draws 172 mW typical, so a switching regulator followed by an LDO post-regulator is recommended to suppress ripple coupling into the analog MDI front-end. Avoid daisy-chaining digital and analog ground returns through a single via.

Avoid these common KSZ8001LI-TR design pitfalls: (1) forgetting the 25 MHz crystal or 50 MHz RMII reference clock requirement - both modes need a stable reference within ±50 ppm; (2) leaving the MODE[2:0] strap pins floating - they must be tied high or low with 4.7 kohm resistors to select MII/RMII/SMII mode; (3) connecting a 5 V MAC to VDDIO when VDDIO is set to 2.5 V - this damages the I/O pins; (4) routing the MDIO/MDC traces longer than 50 mm without a series termination resistor; (5) using an RJ-45 without integrated magnetics as the KSZ8001LI-TR expects a 1:1 transformer in the MDI path.

コンプライアンス情報

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
鉛フリー
Yes
ハロゲンフリー
Unknown
紛争鉱物
Compliant

RoHS3 compliant per Alibaba and DiGi Electronics product listings. Not AEC-Q100 qualified (PHYs rarely are; this is an industrial-temp grade, not automotive). Lead-free per KSZ8001L/S datasheet.

データ検証日: 2026-10-16 — データはXAIPARTの部品エンジニアリングチームによって検証・管理されています

関連検索

KSZ8001LI-TR datasheet Microchip KSZ8001LI-TR 10/100 Ethernet PHY LQFP-48 KSZ8001LI-TR MII RMII SMII KSZ8001LI-TR LinkMD cable diagnostics KSZ8001LI-TR industrial Ethernet PHY KSZ8001LI-TR vs KSZ8721BLI KSZ8001LI-TR buy price reel KSZ8001LI-TR pinout 48-LQFP KSZ8001LI-TR drop-in replacement 100BASE-FX fiber PHY transceiver LQFP what is the difference between KSZ8001LI and KSZ8001LIS

関連部品&用語

Microchip Technology KSZ8001LI-TR KSZ8001LI KSZ8001LIS-TR KSZ8001L KSZ8721BLI Ethernet PHY Physical Layer Transceiver 10BASE-T 100BASE-TX 100BASE-FX MII RMII SMII LinkMD TDR IEEE 802.3 IEEE 802.3u LQFP-48 RoHS Auto-MDIX Auto-Negotiation Industrial Ethernet IoT Gateway
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
合計: $0.00 USD
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示